Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Similar documents
Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Cooling/Heat Pump Convertible Air Handlers

Modular Multi-position Air Handler

Cooling/Heat Pump Convertible Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Variable Speed Convertible Air Handler 5 Ton

Cooling/Heat Pump Convertible Air Handlers

Split System Cooling Product Data

Vertical Upflow Horizontal Left Air Handlers

Split System Cooling Product Data

Variable Speed Convertible Air Handler 4 Ton

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Variable Speed Convertible Air Handler 2 1/2 Ton

Split System Heat Pump Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Split System Cooling Product Data

Fan Powered and Bypass Humidifiers

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product & Performance Data

Modular Multi-position Air Handlers

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Cooling Product Data

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Modular Multi-position Air Handlers

Split System Cooling Product Data

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Heat Pump Product Data

36,000-62,000 BTUH Nominal Capacity

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Split System Cooling Product & Performance Data

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Appendix J Noise Appendix

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Split System Heat Pump Product & Performance Data

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Bosch BVA Series Air Handler

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Split System Heat Pump

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Hyperion TM Split Systems

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Product Data. Split System Cooling A. November 2013

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Product Data. Split System Heat Pump D-EN. February 2016

TECHNICAL SPECIFICATIONS

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Split System Cooling Product Data XB 1000

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Condensing Units & Air Handlers

Product Data. Split System Heat Pump A-EN. March 2016

Transcription:

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA Heat Pump / Cooling Coils for PUB. NO. 22-1903-2

Aluminum Heat Pump Coil Nomenclature 4 P X A B U 2 4 B S 3 H A A A Refrigerant Type 4 - R410A Product Family T - Premium (Heat Pump) N - Premium (Cooling and HP) P - Premium High Effy Dedicated Position Coils (Cooling and HP) C - Standard (Cooling only) F - Entry Level (Cooling only) Coil Design X - Direct Expansion Evaporator Coil Product Family C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5" Refrigerant Line Coupling / Airflow Configuration 0 = Brazed U = Upflow only, convertible to Horizontal Left D = Downflow only, convertible to Horizontal Right Nominal Capacity in 000's of BTU's Major Design Change Efficiency C - Standard S - High Efficiency Z - High Efficiency (TXV modulates to 50%) 3 - TXV - Non-Bleed Coil Circuitry H - Heat Pump C - Cooling Airflow Configuration A - Upflow U - Upflow / Downflow D - Downflow R - Horizontal Left/Right H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Service Digit - Not Orderable 2016 Trane All rights reserved

General Data PRODUCT SPECIFICATIONS [1] -- 4PXA - SPLIT SYSTEM HEAT PUMP / COOLING UNCASED UPFLOW COMFORT COILS 4PXAAU24BS3HAA 4PXABU24BS3HAA 4PXABU30BS3HAA 4PXACU30BS3HAA INDOOR COIL -- Type Rows / F.P.I. Face Area (sq.ft.) Tube Size (Internal check valve) Drain Conn. Size (in.) Duct Connections 2 / 20 3.0 2 / 20 3.0 3.5 3.5 REFRIGERANT CONNECTIONS Line Size -- Gas (in.) Line Size -- Liquid (in.) 3/4 3/4 3/4 3/4 DIMENSIONS (in.) Crated (H x W x D) Uncrated 21.35 x 17.5 x 26.5 14.7 x 13.3 x 21.1 21.35 x 20.5 x 26.5 14.5 x 16.3 x 21.1 21.35 x 20.5 x 26.5 15.8 x 16.3 x 21.1 21.35 x 24 x 26.5 15.8 x 19.8 x 21.1 WEIGHT (lbs) Shipping -- Net 28 / 20 30 / 22 34 / 26 36 / 28 4PXABU36BS3HAA 4PXACU36BS3HAA 4PXABU42BS3HAA 4PXACU42BS3HAA INDOOR COIL -- Type Rows / F.P.I. Face Area (sq.ft.) Tube Size (Internal check valve) Drain Conn. Size (in.) Duct Connections 3 / 12 5.0 3 / 12 5.0 5.5 5.5 REFRIGERANT CONNECTIONS Line Size -- Gas (in.) Line Size -- Liquid (in.) DIMENSIONS (in.) Crated (H x W x D) Uncrated 26.35 x 20.5 x 26.5 21.2 x 16.3 x 21.1 26.35 x 24 x 26.5 20.8 x 19.8 x 21.1 30.65 x 20.5 x 26.5 23.8 x 16.3 x 21.1 30.65 x 24 x 26.5 23.7 x 19.8 x 21.1 WEIGHT (lbs) Shipping -- Net 39 / 31 40 / 32 42 / 34 44 / 36 [1] These indoor coils are A.H.R.I. certified with various split system air conditioners and heat pumps (A.H.R.I. Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org 3

General Data PRODUCT SPECIFICATIONS [1] -- 4PXA - SPLIT SYSTEM HEAT PUMP / COOLING UNCASED UPFLOW COMFORT COILS 4PXABU48BS3HAA 4PXACU48BS3HAA 4PXADU48BS3HAA INDOOR COIL -- Type Rows / F.P.I. Face Area (sq.ft.) Tube Size (Internal check valve) Drain Conn. Size (in.) Duct Connections 6.0 6.0 6.0 REFRIGERANT CONNECTIONS Line Size -- Gas (in.) Line Size -- Liquid (in.) DIMENSIONS (in.) Crated (H x W x D) Uncrated 30.65 x 20.5 x 26.5 25.3 x 16.3 x 21.1 30.65 x 24 x 26.5 24.9 x 19.8 x 21.1 30.65 x 27.5 x 26.5 24.5 x 23.3 x 21.1 WEIGHT (lbs) Shipping -- Net 44 / 36 46 / 38 47 / 39 INDOOR COIL -- Type Rows / F.P.I. Face Area (sq.ft.) Tube Size (Internal check valve) Drain Conn. Size (in.) Duct Connections REFRIGERANT CONNECTIONS Line Size -- Gas (in.) Line Size -- Liquid (in.) DIMENSIONS (in.) Crated (H x W x D) Uncrated 4PXACU60BS3HAA 3 / 16 7.0 34.45 x 24 x 26.5 29.2 x 19.8 x 21.1 4PXADU60BS3HAA 3 / 16 7.0 34.45 x 27.5 x 26.5 28.5 x 23.3 x 21.1 WEIGHT (lbs) Shipping -- Net 52 / 44 53 / 45 [1] These indoor coils are A.H.R.I. certified with various split system air conditioners and heat pumps (A.H.R.I. Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org 4

Performance Data PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW (SCFM) VS. PRESSURE DROP ACROSS WET COIL PRESSURE DROP (INCHES OF WATER COLUMN) MODEL 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4PXAAU24BS3HAA 340 430 510 585 650 715 775 4PXABU24BS3HAA 435 555 660 755 840 920 995 4PXABU30BS3HAA 525 665 790 900 1000 1095 1180 4PXABU36BS3HAA 655 825 970 1100 1220 1330 1435 4PXABU42BS3HAA 625 790 935 1065 1185 1295 1400 4PXABU48BS3HAA 640 815 965 1095 1220 1335 1445 4PXACU30BS3HAA 540 680 805 920 1020 1120 1210 4PXACU36BS3HAA 770 970 1145 1300 1440 1570 1696 4PXACU42BS3HAA 735 930 1105 1255 1400 1530 1655 4PXACU48BS3HAA 760 965 1140 1300 1445 1580 1710 4PXACU60BS3HAA 740 940 1120 1280 1425 1565 1695 4PXADU48BS3HAA 870 1100 1300 1485 1650 1805 1950 4PXADU60BS3HAA 835 1065 1265 1445 1615 1770 1915 5

Outline Drawing for 4PXAAU18BS3HAA, 4PXABU18BS3HAA, 4PXAAU24BS3HAA, 4PXABU24BS3HAA, 4PXABU36BS3HAA, 4PXACU36BS3HAA, 4PXABU42BS3HAA, 4PXACU42BS3HAA, 4PXABU48BS3HAA, 4PXACU48BS3HAA, 4PXADU48BS3HAA, 4PXACU60BS3HAA, and 4PXADU60BS3HAA. (All dimensions are in inches) From Dwg.D345419 Rev. B

Outline Drawing for 4PXABU30BS3HAA and 4PXACU30BS3HAA. (All dimensions are in inches) From Dwg.D345418 Rev. B

Trane 6200 Troup Highway Tyler, TX 75707 www.trane.com For more information contact your local dealer (distributor) Literature Order Number 22-1903-2 File Number 22-1903-2 Supersedes 22-1903-1 Date 03/16 Since Trane has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.