mith Mills Mills 00A OIL OR GAS CAST IRON BOILER/BURNER Smith CAST IRON 00A-
- Gas I=B=R Ratings: Gross Output 7,19 to 1, FRONT VIEW WITH INDUS COMB BURNER SIDE VIEW WITH INDUS COMB BURNER SIDE VIEW - WATER EXTENDED YOKE POWER FLAME - IC BURNER - REAR ACCESS FRONT VIEW WATER TRIM - POWER FLAME BURNER I=B=R RATINGS, BURNER CAPACITIES, DRAFT and CHIMNEY DATA BOILER MODEL NUMBER (Note 1) Boiler Horsepower I = B= R Gross Output () Sq Ft NET I=B=R RATINGS Steam (Note ) Water (Note ) I=B=R Input GPH (Note ) Gas I=B=R Combustion Efficiency (%) Gas Draft Requirements (Inches, WC) Over Fire Draft Loss Total Natural Draft Chimney Size Height (Feet) Induced Draft Fan Capacity CFM (Auburn Axial & Auburn) (Note ) 00A- -1 00A- -1 00A- -17 00A- -18 19 77 719 787 80 98 71 7 78 98 8 11 8 71 8 7 80 8 9 7 89 980 7 11 8 8 81 80 819 817 81 81 1 17 19 7 9 0 x 0 0 x 0 x 0 x 1 7 80 80 00 00A- -19 00A- -0 00A- -1 00A- - 99 1 7 990 8 11 1190 0 8 8 791 817 87 0 81 90 9 8 80 8 9 11 181 1 19 89 88 87 8 81 81 81 811 7 0 7 0 x x x x 77 8 88 9 800 0 80 00A- - 00A- - 00A- - 79 17 118 1 1 081 017 08 80 11 11 8 11 1888 178 177 8 8 8 811 810 810 7 0 7 0 x x x 99 1 180 80 80 (Note 1) Important Ordering Information ( ) Insert "S" for Steam, "W" for Water Example: 00A-S-1 is a 1- section 00A boiler for steam (Note ) Net I=B=R Steam ratings shown are based on piping and pickup allowance of 188 (Note ) Net I=B=R Water Ratings shown are based on an allowance of 11 (Note ) Heavy oil having heat content of,000 BTU/Gal (Note ) Induced draft fan requirements are based on 0 CFM per gallon of oil, inches WC overfire draft and 00 F flue gas temperature and chimney height capable of offsetting friction of fan discharge connections For other conditions, consult your Smith representative
MILLS 00A - CAST IRON BOILER/BURNER UNIT The Ideal System for Schools, Institutions and Commercial Buildings STEAM TRIM OPERATING PRESSURE CONTROL AUXILIARY FLUE GAS VENT FOR GAS FIRED BOILERS MODULATING PRESS CONTROL PRESSURE GAUGE HIGH LIMIT PRESS CONTROL SIPHON 00A WATER DRUM BOILER WATER LINE FRONT VIEW STEAM 17RLS PUMP CONTROL AND LOW LEVEL C/O 00 WCG 1/8" LOW WATER CUT-OFF TOP º DISCHARGE - CLOCKWISE ROTATION View from back of boiler (Opposite hand from view above for counter clockwise rotation) 00A STEAM DRUM SIDE VIEW - AUBURN AXIAL FAN - STEAM WITH POWER FLAME INTERMEDIATE SECTIONS REAR VIEW - AUBURN AXIAL FAN STEAM REAR VIEW - NATURAL DRAFT WATER REAR VIEW AUBURN FAN SIDE VIEW AUBURN FAN Designed and tested according to the ASME boiler and pressure vessel code, Section IV for maximum allowable work pressure Steam 1 lbs, Water, Standard 0 PSI; HT, 80 PSI DIMENSIONS - MILLS 00A Auburn Axial Fan to Fit Smokehood Induced Draft Fan Catalog Number (Note ) C-7 C-0 C- C- Auburn Fan and Smokehood to Fit Boiler 0C -1 1 / 0C -1 1 / 0C00-0C00 - Induced Draft Chimney, Inside Dimensions Metal Flue Pipe or Smooth Lined Masonry Round ( ID ) Rectangular Min Opt Min Opt 7 8 9 0 x 0 x x x x 8 x 0 x x Heating Surface (Sq Ft) 11 99 118 Furnace Volume (Cu Ft) (Note ) 117 1 1 1 Water Content (Gallons) Steam 18 71 Water 0 9 99 79 Overall length Natural Draft A (Note 7) 198 /8 0 /8 /8 7 /8 Power Flame C C C C Electricity Required Horsepower (KW) 7 1 / 7 1 / IC () ** D S D S D S D 1S 7 1 / 7 1 / 7 1 / 1 Electricity Required Horsepower (KW) Compressor Aux Heater Furnace Lgth (In) Foundation Lgth (In) Tapping Size Water Supply Drum Tapping Location Steam Supply Drum Tapping Location Auburn Fan Dimensions B C 1 A B C D E F L B C L J L M EE S T W 8 91 91 9 1 / 1 / 1 / 1 / 0 1 / 1 / 8 1 / 8 1 / 0 1 / 1 / 8 1 / 8 1 / 1 / 71 1 / 77 1 / 80 1 / 71 1 / 80 1 / 8 1 / 9 1 / 80 1 / 89 1 / 9 1 / 1 1 / 89 1 / 9 1 / 1 1 / 7 1 / 7 / 7 / 7 / 7 / 7 7 / 7 / 7 / / / 9 / 11 / 1 1 / 9 /8 8 0 1 / 9 1 / 0 Induced Draft Fan (HP) (Note 7) Auburn Axial / / 1 1 1 / Auburn 1 1 / 1 1 / C-00 C-00 C-00 C-00 0C00 - C00 - C00 - C00 - C00 - C00 - C00-7 7 8 8 9 9 1 x x x 8 x 8 x 0 x 0 x 8 x 8 x 8 x 8 x 8 x 8 x 0 x 0 181 19 17 9 18 19 118 11 1 179 18 199 0 119 1 77 0 1 7 8 778 817 87 8 9 1,01 /8 1 7 9 71 C C -B 1 1 1 1 0 D 1S D 1S D 1S D 17S D 17S D 17S D 17S 1 1 1 0 0 0 0 9 11 11 17 1 19 1 11 11 17 1 19 1 11 1 / 1 / 0 1 / 1 / 1 / 8 1 / 7 1 / 1 / 1 / 0 1 / 1 / 7 1 / 78 1 / 8 1 / 7 1 / 7 1 / 80 1 / 8 1 / 9 1 / 98 1 / 1 / 8 1 / 91 1 / 1 / 1 / 9 1 / 11 1 / 11 1 / 98 1 / 1 / 9 1 / 11 1 / 11 1 / 17 1 / 1 1 / 7 1 / 11 1 / 118 1 / 1 1 / 1 / 1 1 / 1 1 / 11 1 / 119 1 / 1 1 / 11 1 / 17 1 / 1 1 / 19 1 / 7 / 9 / 9 / 9 / 81 / 81 / 81 / 7 / 87 / 87 / 87 / 99 / 99 / 99 / 11 / 17 / 1 / 19 / 1 7 / 8 1 / 11 / 17 / /8 0 1 / / / 1 1 / 1 1 / (Note ) Furnace volume based on use of Smith combustion chamber The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc (Note 7) For exact dimensions of burner, natural draft or induced draft combination chosen consult Smith Cast Iron Boilers (Note 8) Pumping: Industrial Combustion: All model D burners require an oil transfer pump for oil supply A transfer pump is not furnished as standard equipment (Note 9) Fractional horsepower motors are for operation with 11/0V, 0-Hz current at constant speed Other voltages and variable speed options are available on special order (Note ) 1/ HP Metering Pump on all oil units (Note) Dimensions are approximate and should not be used to roughin equipment ** s: DL = # ; DM = # ; DE = # ; Add G for Gas For further details and information regarding burners, refer to 00A Installation & Operating Instructions
STANDARD EQUIPMENT All Boiler- Units Insulated metal jacket Shutter dampers Pre-cast combustion chamber with insulation Steel channel ventilating base, " high Flexible return yoke Bronze body, lever-operated, ball-type drain valves for return drums Cleaning tools Natural draft Steam Boilers " steam pressure gauge ASME side-outlet safety valve set at 1 psi M/M 17RLS water column type pump control and low water cut-off with precut ferrous pipe and fittings Manual reset high-pressure limit control Operating pressure control Modulating pressure control Water Boilers Pressure-altitude gauge ASME relief valve set at 0 psi M/M # low water cut-off with precut ferrous pipe and fittings 1/ diam dial thermometer with remote bulb Dip tube and air removal fittings and manual vent valve Manual reset temperature limit control Operating temperature control Modulating temperature control M/M # low water cut-off for HT boilers RELIEF VALVE DATA Sections 1-1 17-18 19 - - Sections 1 1-17 18-1 - - Vendor 00A SAFETY VALVES (STEAM) 90 90 90 90 90 Valve #1 1/ 1/ Valve # 1/ 1/ 00A SAFETY RELIEF VALVES (WATER) Vendor 70 70 70 70 70 Valve #1 1 1/ 1 1/ 1 1/ Valve # Valve # Valve # 1 1/ 1 1/ OPTIONAL EQUIPMENT All Boiler- Units Special tappings Lead-Lag control Controls with alarm switches FM, IRI or IRM approval Automatic fuel changeover control (gas/oil burners) Integral draft inducer Steam Boilers M/M #18 high water cut-off with alarm contacts 8 1/" compound gauge Cast iron water column M/M #1S- automatic water feeder and low water cut-off Water Boilers Boiler constructed and tested for 80 psi max water working pressure (HT) -inch tapping in front end of supply header for domestic hot water heater Optional Control Equipment Wall mounting panel in lieu of floor standing Full choice of Fireye or Honeywell electronic combustion and flame-failure controls Starter reset buttons in panel door Control transformer (when V, 1 phase, 0-Hz current is not available) Smoke density indicator with recorder and voltage regulator Flue gas temperature indicator Alarm bell and silencing button with alarm relays Assorted indicating lights, volt meter, micro-ampmeter, manual potentiometer, etc ELECTRICAL CHARACTERISTICS and Secondary Air Fan phase, 08 volt, 0 Hz; phase, 0 volt, 0 Hz; phase, 0 volt, 0 Hz Heater 1 phase, 0 volt, 0 Hz ID Fan 1 phase, 11/0 volt, 0 Hz; phase, 08/0/0 volt, 0 Hz
THESE FEATURES ASSURE TOP PERFORMANCE Scientifically Matched Boiler Unit Every detail of the 00A Boiler unit for oil and gas is the result of years of research and development The boiler, the burner, the draft system, the control system, and the combustion chamber are completely compatible The 00A offers a choice of four burners from top manufactures, each tailored for maximum efficiency and tested and listed by IBR Single source responsibility can be assured, whether your fuel choice be # thru # oil or gas Each unit is backed by factory service technicians from a factory service force formed in 190 A wide variety of control panel options, draft systems and ID fans can be tailored for most any need, no other cast iron boiler company can offer you all these features Header Type Construction Standard Electrical Characteristics s phase, 08 volt, 0 Hz; phase, 0 volt, 0 Hz; phase,0 volt, 0 Hz Control Circuit 1 phase, 11 volt, 0 Hz Heater (when used) 1 phase, 0 volt, 0 Hz Mills boilers are independent header type sectional boilers Each section is, in reality, an individual boiler connected to supply and return headers Should some accident, such as low water, cause a section to break, it may be disconnected in a few minutes time without interruption of service and may be replaced when convenient IC MODEL D # - #, Gas, or Combination POWERFLAME MODEL C #, Gas, or Combination In the interest of product improvement, Smith reserves the right to make changes without notice Smith CAST IRON Westcast, Inc 0 North Elm Street Westfield, MA 08 Tel: (1) -91 FAX (1) -799 wwwsmithboilercom Printed in USA