Maintenance and Troubleshooting of Oil Diffusion Pumps

Similar documents
AGILENT DIFFUSION PUMPS. 2-3 Features and Benefits 4-5 Typical Applications 6-29 Pump Models 30 Fluids 31 Baffles Technical Notes

AGILENT ION PUMP 200 The first ion pump with maximum pumping speed at low pressure

Varian, Inc. Vacuum Technologies. Diffusion Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models Fluids

Varian, Inc. Vacuum Technologies. Diffusion Pumps. Feature and Benefits Typical Applications Pump Models

VHS-10 & VHS-400 Diffusion Pumps

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

AGILENT VS SERIES LEAK DETECTORS

INLET PRESSURE - TORR

Water Distiller Service Manual

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

Vacuum Pumping process for Large Camera Dewars supplied by PixelVision of Oregon

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581

2016 Ideal Vacuum (505) V 1.1

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Desiccant Breathers: A Front Line Defense in the War on Contamination

Scientific vapor pumps

Refrigerant Recovery Machine. Model No Operating Manual

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

Oil burners fuel unit with solenoid valve

Operating Instructions incl. Manufacturer's Declaration. Diffusion pump. with optional baffle DIF 501 BP BE (0003) 1

High Throughput Diffusion Pumps

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS: 2567B-01, 2567B-50, 2567C-02, 2567C-50

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

KINNEY OIL MIST ELIMINATORS

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

COOLVAC

Econo Heater. Waste Oil Fired Heater. Installation, operation and service instructions EH v Manual. Manufactured by

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Custom Products Gallery

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 630 BP BE (9803) 1

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 320 BP BE (9906) 1

Heat up ramp rate 100 degrees C per minute - empty chamber.

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

V-Series. Oil Lubricated Rotary Vane Vacuum Pumps

User s Information Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Varian Vacuum Technologies 121 Hartwell Avenue Lexington, MA (781) (800) 8-VARIAN. HS-32 Diffusion Pump. Instruction Manual

USER S INFORMATION MANUAL

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

Elite. User s Information Manual. Elite and Elite VWH* All Models

Oil burners fuel unit with solenoid valve

AXPR Wall Mounted Axial Panel Fans

OWNER S MANUAL FOR DUOSEAL VACUUM PUMPS MODELS: 1400, 1405, 1402, 1376, 1397, 1374, 1399, 1380, 1392

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

ULTRA LOW TEMPERATURE FREEZER. User Manual

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Diocese of Cleveland Facilities Services Corporation

Specification Sheet. Equipment Model: BVAC-1200 Vacuum Furnace. Type. Chamber. Maximum Temperature 1250 C. Hot Zone

Light oil burners. One stage operation

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS 2585B-01, 2585B-50, 2585B-55 & 2585Z-50

Columbia Boiler Company

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

442 Chapter 16. Figure 16-5 Gas leak detection

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

ACT Cartridge Dust Collector

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Preventative Maintenance Tables

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Room Air Conditioner Service and Parts Manual

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

Manual Physical Vapour Deposition System

Vacuum Booster for Distillation Process

Universal fuel unit for oil burners

451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

BASIC BOILERS NAME :- DATE :-

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Handling Petroleum Products & Static Ignition Hazards Introduction

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 / 2032 / 2042 / 2034 / 2044 / 2037 / 2047

FIREYE C9707A ALL FUEL SCANNER

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Patriot. Automatic Pool Vacuum Cleaner. Patent No. 5,794,293. Owner's Guide. Model *Recommended for 3/4 HP and above

LONGONI ENGINEERING SRL

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019

Module 7: Air Supply System

CPF PRODUCT DESCRIPTION

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

In-Line Air Separators

OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

STEAM STERILIZER SERIE S1000 (RBE)

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

OWNER S MANUAL FOR WOB L PISTON VACUUM PUMP MODELS: 2561B B C C C C-25

Refrigerant Recovery Unit, Model RRU134

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

COOLING SYSTEM. Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... DESCRIPTION...

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Transcription:

Maintenance and Troubleshooting of Oil Diffusion Pumps Solution Note Agilent VHS-4 Diffusion Pump How Diffusion Pumps Work Operating Diffusion Pumps Diffusion Pump Maintenance Diffusion Pump Troubleshooting Guide Oil diffusion pumps are still a widely used type of high vacuum pump. This is because they are relatively inexpensive, highly reliable, and very durable. Yet oil diffusion pumps require careful maintenance in order to maintain a high level of performance and maintain the integrity of the vacuum chamber. This application note will explain practical steps that can be taken to ensure optimal performance of oil diffusion pumps in a production environment. How oil diffusion pumps work Diffusion pumps differ from conventional mechanical pumps in that they use a highspeed jet of fluid to direct gas molecules in the pump throat down to the bottom of the pump and out the exhaust, which is usually called the foreline. The high-speed jet is produced by boiling the fluid, such as silicone oil, and then directing the vapor through a series of vertically-stacked cone-shaped jet assemblies. Typically there are three jet stages of diminishing size with the largest at the bottom and the smallest at the top. The boiling oil moves upward through the jet assemblies and then is expelled in a downward direction at the top of each assembly. Exiting from the jets, the high-energy oil droplets travel downward in the periphery of the chamber at speeds up to 335 meters per second. The vapor jets entrain gas molecules and direct them towards the exhaust port, where they are pumped away by a roughing pump. The effect of removing molecules is to create high vacuum in the upper portion of the pump, which is connected to the vacuum chamber.

A roughing pump lowers the pressure inside the diffusion chamber to approximate 10-2 mbar or lower. This makes it possible for the diffusion pump to create a vacuum ranging from 10-3 to 10-9 mbar (10-1 to 10-7 Pa). Pumps and jet designs have evolved over the years and improved synthetic fluids have been developed, enabling the high levels of vacuum to be achieved with this pump technology. The pump external housing (or shell) is generally water-cooled to prevent thermal runaway. In all diffusion pumps, a small amount of backstreaming, movement of oil molecules into the vacuum chamber, occurs. In many applications, this is acceptable. In more critical applications, an optically-dense baffle is typically provided to deflect particles before they can reach the process stream. A trap is placed above the baffle and cooled to a low temperature to condense hydrocarbons and water vapor from the pump chamber. Due to the possibility backstreaming, diffusion pumps may not be suitable for use with the most sensitive analytical equipment. Operating diffusion pumps A large amount of energy is stored in an oil diffusion pump so careful attention must be paid to ensure safe operation. Oil diffusion pumps should never be used for roughing because exposure to atmospheric pressure levels can cause hot hydrocarbon fluids to ignite or explode. Air leaks into the system also present safety concerns for the same reason. Avoid contaminating the pumping fluid with foreign matter because it can change its viscosity and obstruct flow passages. Operation of the diffusion pump without circulating cooling water to the main body cooling coils is also dangerous, and will lead to unstable operation. Some more basic operating rules: Do not turn on the heater without fluid in the pump. This may damage the heaters and pump assembly. Do not air-release the pump while the boiler is hot. Most diffusion pump fluids break down under these conditions. Do not power the pump heaters unless cooling water is circulating. This can cause the pump and fluid to overheat, and will lead to unstable operation. Do not operate the pump without a foreline baffle. This may cause a greater than normal fluid loss. Diffusion pump maintenance It is recommended to keep logbooks for diffusion pumps to track maintenance history, and operational manuals to ensure maintenance is done per the manufacturer s recommendations. During maintenance activity, the surfaces inside the vacuum diffusion pump need to be kept very clean in order to avoid contaminating the vacuum chamber. Even a single fingerprint can outgas water vapor and other molecules. When a pump is disassembled for routine maintenance and cleaning, it should be purged with dry nitrogen just prior to use. When a diffusion pump is pumping at a slower than normal rate, look for outgassing of moisture on the surfaces of plastics or other volatile substances or a leak. Check the condition and level of the fluid when the pump is cold. Withdraw a sample through the drain and visually check the level of fluid through the sight glass. Use new o-ring gaskets when replacing fill and drain plugs. During maintenance intervals, if there is diffusion pump oil loss, log the amount. This loss of fluid can be caused by: Air leaking into the pump Inadequate water cooling Continuous operation in the overload inlet pressure range, also referred to as the knee of the curve. Failure to insert the foreline baffle in the pump assembly. The recommended frequency at which the diffusion pump fluid should be changed depends on the specific process. Slight discoloration of the fluid does not affect pump performance but material build-up can lead to inefficient heat transfer. For a dedicated manufacturing process, it is possible to establish 2

color based standards to help provide guidance for fluid replacement. It s important to note that new fluid is subject to outgassing. This can cause periods of foreline pressure fluctuations. These will quickly resolve themselves as the fluid becomes fully degassed. If multiple processes are run on the same pump or vacuum chamber, there is the risk of cross-contamination of byproducts through the fluid. It may become necessary to change the fluid more often in this situation. After maintenance, the pumpdown characteristics of the system should be monitored. The best approach is to keep a log that compares the pumpdown curves after maintenance over time. This approach will help to provide an early warning of system leakage. When a leak is identified, the first step should be to check the following items: The integrity of the inlet and foreline connections The tightness of the drain and fill plugs The other compression fittings, such as those that connect the high-vacuum gauges Threaded connections, such as the foreline gauge. Also check the performance and accuracy of the vacuum gauges used in the system. In some cases, cooling coils may become obstructed due to solid deposit buildup. Check the flow meters used to measure the cooling water flow to ensure that water can flow freely through the coils and that the flow rate does not fall below the manufacturer s specifications. Heater elements may burn out from time to time and need to be replaced. As a preventive precaution, when the pump is cold, check that the heaters are bolted snugly to the boilerplate and that all heater terminal connections are fastened tightly inside the junction box. Also, check the total heater power input and load balance. The following other items should be checked on a regular basis: The position of the system valves should be checked before repositioning The level of the diffusion pump fluid Confirm that water is flowing through the cooling water lines. 3

Diffusion Pump Troubleshooting Guide Fault Probable Cause Corrective Action Poor system pressure Leaks in system, virtual or real Locate and repair High process gas load Measure gas load, eliminate cause System is dirty Clean system to reduce outgassing Poor ultimate pressure Contaminated pump fluid Examine and clean pump; replace fluid Low heat input Check voltage. Check for continuity, burned-out element, poor thermal contact Inadequate cooling water flow Check water pressure. Check tubing for obstructions and backpressure Cooling water is too cold Check temperature Cooling water flow is too high Adjust water flow High forepressure Check for leak in foreline, poor mechanical pump performance, breakdown of mechanical pump fluid Water in Quick Cool coil Check and remove cause Slow pumpdown Low heat input Check heaters Low fluid level Add fluid Malfunctioning pump assembly Check and repair or replace Improperly located jets Check and repair or replace Damaged jet system Check and repair or replace Inlet pressure surges Incorrect heater input Check and correct Fluid outgassing Condition fluid by operating the pump for a few hours Leak in system ahead of pump inlet Check and correct High chamber contamination of the pump fluid Pump will not start Forepressure too high Check for leak in foreline, poor mechanical pump performance, breakdown of pump fluid, and incorrect valve operation Prolonged operation in overload Adhere to operating procedures range Cutting over from the backing Cut over at a lower chamber pressure pump too early in the pump down cycle Improper system operation and air Adhere to operating procedures release procedures Safety circuits or protective devices Check utilities, flow devices switches, interlock. prevent contactor from staying Check thermostat operation closed 4

Conclusion Diffusion pumped vacuum systems often provide the most efficient and cost-effective environments for production processes. To secure these benefits, it is extremely important to follow the simple maintenance practices described here or as recommended by the pump manufacturer. A small investment in planned maintenance can yield a high return in the ongoing high-level performance of your production system. References Diffusion Pumps Performance and Operation, Hablanian, American Vacuum Society 1994. Hablanian, M. H., High Vacuum Technology, 2nd ed. New York: Marcel Dekker, 1997:207. Agilent Technologies Diffusion Pump Operational manual (699901140) For more information: North and South America Agilent Technologies 121 Hartwell Avenue Lexington MA 02421 USA Toll free: +1 800 882 7426 vpl-customerservice@agilent.com Europe and Other Countries Agilent Technologies Italia S.p.A. via F.lli Varian 5410040 Leini (Torino), Italy Toll free: 00 800 234 234 00 vpt.sales@agilent.com vpt-customerservice@agilent.com www.agilent.com/chem/vacuum 5