RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Similar documents
RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Energy Division

MXSU - Selection table 3-core Kits / X-section

Terminations. Energy Division. Return to Contents

Section 8: Switchgear Connections (Straight & Elbows)

Heat-Shrinkable Termination System for Cables up to 36 kv

BISG II. Bus Insulator Squirrel Guard. This new and improved isolation guard prevents animal-caused outages in electrical substation equipment.

Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

Energy Division. CSJR / CSJH Cold shrinkable straight joints for polymeric insulated cables up to 36 kv

Section 4: Medium Voltage Terminations - up to 42kV.

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

PolyGarde Metal-Oxide Surge Arresters

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing

Section 7: Cable Glands & Duct Seals.

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

Energy Division. Raychem Insulation Enhancement Systems

Connecting the World of Power ENERGY DIVISION

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Reliable solutions for electrified railway systems

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

.025 Connector Series

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

RF one-step BNC/TNC connectors for coaxial cable termination

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

Section 4: Medium Voltage Terminations - up to 42kV

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

GMA Panels with double busbar

RAYCHEM MEDIUM VOLTAGE

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Evolution of stress control systems in medium voltage cable accessories

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Raychem Link Boxes. Cable Services Limited. Powering the UK

Section 5: Medium Voltage Joints - up to 42kV

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

HVS S 15kV Class

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

ENERGY PRODUCTS DIVISION. Enhancing the Reliability of Cable Networks. Cable Accessories for upto 245 kv

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

Energy Division. Raychem Raysulate Insulation Enhancement Systems

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

I N D I V I D U A L SWITCH G E A R

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

SION Vacuum Circuit-Breakers

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

Raychem Raysulate Insulation Enhancement Systems

Qualification Test Report 1/Jul/2005 Rev. A

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Energy Division. Accessories for the Installation of Low Voltage & Medium Voltage heat-shrinkable products for the Electrical Power Industry

TE Connectivity's AMP NETCONNECT Cable Management

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

Frost Protection Thermostat

Installation Procedure for D-200 series Shielded Cable Splice Kits with MiniSeal Crimp Primary Splices

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Contents. General information typical products summary 3. Low-voltage tubings 21. Cable end sealing kits, endcaps, and breakouts 35 1

Jun08 Rev C

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

Semiconductor Solutions. Your global source for industrial automation, control, and power distribution products and services

SolderSleeve Insulated Electrical Termination Devices

Mar11 Rev B

COMPANY PROFILE Electrical & Instrumentation Contractor

energy.te.com ONE CLEAR SOLUTION FOR BOTH ROUGH ENVIRONMENTS AND TOUGH SPECS.

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

3-way switching valve

Always ahead of the game with the Klauke product range for utility companies

HVS S Splice Series

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

SECTION ELECTRICAL IDENTIFICATION

Jun08 Rev A

You work hard on your panel. we work hard in your panel. PRODUCTS FOR

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

TRANS ATLANTIC TRADING ENTERPRISE INC.

WILDLIFE AND ASSET PROTECTION

Terminal lugs for LV power cables with aluminum conductors

Remote alarm indicator and test combination MK2430

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Jan05 Rev A EC

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

TECHNOLOGY WEDGE PRESSURE HV JUICE PAGES 2 & 3. Pop-N-Work Pop-Up Tents PAGE 5. June/July This Issue.

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

/Oct/2014 Rev B

TraceTek Leak Detection

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Transportation. Distribution

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

Dräger VVP 1000 System Components

SPECIFICATION NPS - 210/6 FOR SF6 INSULATED SWITCHGEAR FOR SYSTEM RATED VOLTAGE UP TO 24 kv

Transcription:

R RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv The increasing popularity of gas insulated switchgear called for the development of an appropriate connection to the bushing. Raychem has developed two systems for this purpose. The RICS insulating adapter (630 A) is compatible with all Raychem terminations and can thus be used to connect any type of cable, irrespective of whether it is paper or plastic insulated or has one or three cores. Simplified installation The compact design of the adapters and their clear cut profiles simplify installation. The electrical connection with the aid of a stud renders additional fastening systems unnecessary. Reliability Raychem has several decades of experience in the field of hermetically insulated termination systems for medium voltage applications. The adapters are water tight and guarantee uninterrupted operation, even under extreme environmental conditions with severe pollution. Tests The adapters conform to IEC 540, VDE 0278 and ANSI IEEE 386 specifications, as well as to the Raychem specification PPS 3013. The test requirements and results are summarized in Raychem Test Report PPR 1106, which is available on request. Different cables... New materials and new production methods have changed the face of medium voltage cables completely over the years, resulting in increased com-plexity. Paper and plastic insulated cables with one or three cores, round or sector shape, and many different types of shielding, water blocking systems, as well as varying insulation thickness can be found in today's networks....need different terminations... Catering for a wide range of cables with as few fittings as possible, while optimising the products for specific applications and maximising their reliability, was the logical consequence....or Raychem flexibility. Heat-shrink technology makes it possible to use a single size of fittings for a large number of cable cross sections and types. This universal technology not only reduces the requirement for jointer training but also the installation time, at the same time increasing the reliability, irrespectice of the type of cable used in the network.

RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv The insulated adapter termination system provides perfect sealing, electrical insulation and an electrical connection between Raychem terminations and SF 6 -insulated switchgear up to 24 kv. Its lead-in insulator (630 A) conforms to DIN 47636 and ANSI IEEE 386. The cable box of the switchgear must be provided with suitable protection against electric shock. The insulating adapter is compatible with all Raychem terminations. Details of the terminations can be found in the cable accessories catalogue. T-adapter with or without surge arrester Design Thick walled insulator made of high quality elastomer with sealing face over the termination, bushing cone and plug. The electrical connection is made with a terminal stud and the cable lug of the termination. Two cable connection is possible. A special plug which allows cable testing without disconnecting the adapter is also offered. The design of the adapter for connecting the surge arrester is basically identical. The elastomer insulator has an additional lead-in duct for the surge arrester. Details of the surge arresters can be found in the brochure EPP 0533. Scope of supply (for three phases) Insulator, plug, terminal stud, small accessories and installation instructions. Straight adapter Design A thick walled, heat-shrinkable insulating sleeve provides a hermetic seal over the cone of the bushing and the termination. The adapter area is smoothed with a meltable filler strip. Scope of supply (for three phases) Heat-shrinkable insulating sleeving, filler strip, small accessories and installation instructions. Terminal stud and lug must be enclosed. T-adapter fitted with testing plug T-adapter for perpendicular connection of the termination to SF 6 -insulated switchgear Straight adapter for vertical connection of the termination to SF6-insulated switchgear T-adapter for perpendicular connection of termination and surge arrester to SF6-insulated switchgear

Merlin Gerin RM6+ Siemens 8DJ10 Calor Emag Z L4 Driescher Minex C Felten & Guilleaume GA AEG FBA GEC Alsthom T&D BTL Driescher Minex D ABB CTC

Wedge technology products Electrical connectors Cable accessories Overhead conductor hardware Asset protection Surge arresters Insulators Fittings Associated toolings All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no cirumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for this product is set forth in our standard terms and conditions of sale. AMP, DULMISON, ELCON, ELO TOUCHSYSTEMS, HTS, M/ACOM, MADISON, NETCONNECT, RAYCHEM, SIMEL are trademarks of Tyco International Ltd. Members of the Tyco Electronics Corporation: Raychem EPP 0532 3/00 Tyco Electronics Raychem GmbH Energy Division Haidgraben 6 85521 Ottobrunn/Munich Germany Tel. (089) 6089-0 Fax (089) 609 63 45 Tyco Electronics Corporation Energy Division 8000 Purfoy Road Fuquay-Varina, NC 27526-9349, USA Tel. (800) 327-6996 Fax (800) 527-8350 Tyco Electronics Corporation Energy Division c/o AMP Singapore Pte Ltd No. 26 Ang Mo Kio Industrial Park 2 Singapore 569507 Tel. 65-4836012 Fax 65-4836031 www.tycoelectronics.com