WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

Similar documents
KOCH Curtain Coaters

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Type N RotoClone. Hydrostatic Precipitator. Better Air is Our Business

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

Direct Fired Heater Model AD Specification

FT900BD FLIGHT-TYPE DISHWASHER

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Magnaflux-Zyglo Modular FPI Inspection System

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

hinged tops or hinged doors.

FAS-300 Central Dust Collection Systems

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

NESCO LIMITED PAINTING SYSTEM DIVISION SHOT BLASTING PRETREATMEN PAINT BOOTH ABOUT US: PAINT BOOTH

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Division 11 - Equipment

XPert Balance and Bulk Powder Enclosures

KIC Air Curtains. Technical Guide

C SERIES s r o t c e l l o C t s u D e n o l c y C

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Closed Circuit Cooling Towers

WCD-1. Evaporative Cooling Modules. WCD Series. Alton. Keeps You. Cool

TIO THE LEADER SPRAY BOOTH APPLICATIONS

Clean. Easy. COMPLIANT.

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Selecting the Correct Fan

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

MCB SERIES. cross ventilation cartridge dust collector

AUTOMATIC FIRE SUPPRESSION SYSTEMS

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

MCB SERIES. cross ventilation cartridge dust collector

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

AUTO REFINISH PRODUCT CATALOG GLOBALFINISHING.COM

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Complete Solution for Painting & Baking

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

CARTER DAY CARTER DAY AUDU & 12/32/50 DRYER DIMENSIONS 12 SERIES DRYERS MICRO DRYER 50 SERIES DRYERS 32 SERIES DRYERS

INSTALLATION AND OPERATIONS MANUAL

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Direct Gas-Fired Make-Up Air

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

container glass table ware glass decoration speciality glass float glass pattern glass Float- and Display Glass Annealing Lehr

August 2016 Volume 23, Number 8. Specifiying WOOD DRYING OVENS. By Mike Grande, Wisconsin Oven. Follow us on:

Innovation in air purification unmatched air quality

GLOBAL FINISHING SOLUTIONS

Modular Supply Make-Up Air Unit

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Linear Floor Heaters

FT900 FLIGHT-TYPE DISHWASHER

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Figure 1-1 Furnace Front Elevation

Spray Painting and Coating

SECTION AIR COILS

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

CLe-series Dishwashers

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

Design Specifications for Panda 900A Car Spray Booth

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

ROTARY DRYER CONSTRUCTION

Gas-Fired Unit Heaters Commercial & Industrial

SPRAY PAINT BOOTHS & OVENS

Twin City Fan & Blower

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Double Skin Casing Air Handling Units

Submittal Data Performance Data Electrical Data

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

DALAMATIC DUST COLLECTORS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Our Purifier systems

Indirect Gas-Fired Make-Up Air

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

MSYS 4490 AC Systems


FT1000 FLIGHT-TYPE DISHWASHER

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Efficient, Long Lasting Evaporative Condensers

GLOBAL FINISHING SOLUTIONS AUTO REFINISH. Product Catalog. The World Leader in Paint Booth Technology.

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

FT900S FLIGHT-TYPE DISHWASHER

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Contents INDEX. TDM Series Indirect Fired Heaters

Precision Containment for All Applications

Double Skin Air Handling Units

Air Make-Up Units. Product Line Overview & Capabilities

FT900S FLIGHT-TYPE DISHWASHER

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Transcription:

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE Highest Quality Finish and Environmentally Safe The Spray Systems Water wash Spray Booth provides an extremely efficient means for removing paint particles from the exhausted air by using water as a filtration medium. Water wash booths are utilized for high volume paint usage. In addition, water wash booths handle a larger variety of paints as compared to dry filter booths, with a wider range of viscosities and drying speeds. Water wash booths are favored by all health, fire and building codes. Flexible and Adaptable Spray Systems water wash booths are designed for many finishing applications. We offer both pump and pumpless versions in open face, enclosed, and conveyorized models. Adapting front filter doors, air make-up systems, sludge de-watering, and special spray booth controls are just a few ways that we can engineer a custom booth for you. Appearance and Durability Your water wash booth will have a quality appearance with our durable premium grade G-90 galvanized steel. The collection pan is fabricated using heavy gauge galvanized steel with continuous welded construction. PACKAGE Features & Benefits CNC and CAD Technology panels are manufactured of premium 8 gauge G-90 galvanized steel, and are precisionpunched on six inch centers, allowing for easy nut and bolt assembly, and exploded view assembly drawings supplied Quiet typically operates at low dba noise levels, below OSHA limits High Efficiency tri voltage, TEFC, motors that match the high efficiency performance of the exhaust fan ing high efficiency lighting fixtures designed for mounting outside booth, industrial rated, four-tube (T-8) fluorescent fixtures with dust-tight seals and are UL/ETL listed UL Listed all electrical components and latching devices are UL/ETL listed Essential Accessories all necessary caulking, nuts, bolts, and hardware for proper booth installation East Grand Ave., Pomona, CA 97 909..9 800.7.9 Fax: 909..7

-Type Water Wash Features Removable front water curtain Open impeller water pump with TEFC direct drive motor Includes pump base for easy mounting Operation Advantages And Benefits Clean Booth The elimilator s paint collecting surfaces are water-scrubbed. stack, fan and components stay cleaner longer because of the high efficiency of the washer High Efficiency Paint-latent exhaust air is washed and then scrubbed four times while traveling through the eliminator wash section, while paint particles are trapped in the collection pan. The PVC manifold-deflector plate assembly disperses water evenly to maintain an unbroken water curtain, and can be easily removed without special tools for maintenance Minimal Floor Space The short depth of the eliminator section maximizes your shop s floor space Easy Maintenance Circulating water forms a continuous, constantly flushed system which has no sediment accumulation and dead-ends; pump water pressure and flow are quickly adjustable; an automatic water level control supplies make-up water to compensate for evaporation losses Removable front water curtain permits easy skimming of coagulated paint particles from collection pan Clog-free water circulating system; intake pipe is above the pan floor to assure a sediment-free supply of water. System is self-flushing The water wash requires chemical treatment. This causes the paint particles to coagulate and allows convenient skimming when cleaning the collection pan. Spray Systems recommends that you consult a reputable chemical supplier for the proper compound to suit the material being sprayed Hinged water curtain to allow easy access to the rear of the collecting pan Door located just below the fan for easy maintenance Slotted water intake pipe to ensure sediment-free water Sludge de-watering Spray Systems recommends that you use a centrifuge-type sludge de-watering device to remove paint particles from the collection panel. Contact your Spray Systems Advisor for more information Spray Systems building your booth the right way for all the right reasons

Washer Eliminator Section The washer eliminator section features an upper and lower wash chamber with a large capacity collection pan. The paint particles are scrubbed from the air first by a continuous curtain of moving water, and second, by the air flow changing direction rapidly. This action allows centrifugal force to fling the solid particles out of the air stream and down to the collection pan. These two scrubbing actions virtually free the air of any air born particles before reaching the exhaust stack. Our eliminator section uses a unique spray manifold design which does not require spray nozzles. This design of the manifold reduces clogging and is easier to clean and maintain. In addition, the eliminator section uses a non-clogging impeller-type recirculation pump with a U coupling direct drive motor. Upper Eliminator Wash Section The majority of the paint particles are separated from the exhaust air in the upper centrifugal wash chamber. This separation is accomplished by imposed centrifugal force on the paint particles as the air abruptly changes direction of flow while simultaneously being forced to pass through a powerful water spray manifold. Lower Eliminator Wash Section In the lower wash chamber, the exhaust air must pass through an unbroken curtain of water. Water scrubbing and centrifugal force combine to remove the remaining paint particles before the air passes to the exhaust chamber. The Spray Systems washer is designed to keep heavy moisture from traveling through the exhaust plenum and ductwork. Spray Systems building your booth the right way for all the right reasons

Type Water Wash Booths PVC return pipe with valve Quiet fans- typically operates at low dba noise levels. Rated for.0 static pressure. Tubeaxial, belt-driven, with non-sparking blade General Purpose s ETL Approved, -Tube, T-8 PVC piping with valves 0'-" O H H W '-0" D FOR PUMP O W CLEARANCE FRONT VIEW O D SIDE VIEW Open impeller water pump with TEFC direct drive motor 8 High Standard -Type Water Wash Booth s (00 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @.0 S.P. GPM WP-8 WP-887 WP-087 WP-87 WP-87 WP-87 WP-887 WP-087-0 7-9 -0 7-7 -9 7-9 - 7-9 7 - -0 7-9 7 - -0 7-9 7 - -0 7-9 7-8 -0 7-9 7-0 -0 7-9 7 - - 0-7 0-7 -0 0-7 -9 9-0 0-7 -9-0 0-7 -9-0 0-7 -9 7-0 -7-9 9-0 -7-9 -0 0-7 -9. 000 00 8000 900 00 800 00 000 0 0 00 0 0 80 0 00 7. 7. 7. 0 0 00 0 97 9 00 9 7 800 Spray Systems building your booth the right way for all the right reasons

0 High Standard -Type Water Wash Booth s (00 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @.0 S.P. GPM WP-807 WP-007 WP-07 WP-07 WP-07 WP-807 WP-007 7-9 -9 7-9 - 9-9 7 - -0 9-9 7 - -0 9-9 7 - -0 9-9 7-8 -0 9-9 7-0 -0 9-9 7-7 - 0-7 -9 9-0 -7-9 -0 0-7 -9-0 0-7 -9 7-0 -7-9 9-0 -7-9 -0 0-7 -9 8000 0000 000 000 000 8000 0000 0 00 0 0 80 0 00 7. 7. 7. 0 0 77 0 80 7 7 700 800 High Standard -Type Water Wash Booth s (00 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @.0 S.P. GPM WP-87 WP-07 WP-7 WP-7 WP-7 WP-87 WP-07 7 - -9 7-9 - -9 7 - -0-9 7 - -0-9 7 - -0-9 7-8 -0-9 7-0 -0-9 7-8 - - -9 0 - - -9-0 - -9-0 - -9 7 - - -9 9 - - -9-0 - -9 7. 7. 900 000 00 800 900 00 000 0 00 0 0 80 0 00 7. 7. 7. 0 0 7 80 780 7 97 800 900 Options / Accessories Access Doors Air Make-up Units Air Solenoid Valves Control Panels Constant Velocity Controls Energy savings stand-by/idle mode Stack Components Front Filter Doors Heaters / Infrared ing Magnahelic Gauges Observation Windows Pressurized Air Supply Plenums Centrifuge Stainless Steel Wash Chamber Spray Systems building your booth the right way for all the right reasons

-Type Conveyorized Water Wash Booths PVC return pipe with valve Quiet fans- typically operates at low dba noise levels. Rated for.0 static pressure. Tubeaxial, belt-driven, with non-sparking blade General Purpose s ETL Approved, -Tube, T-8 Conveyor opening custom designed to accommodate part specifications PVC piping with valves 0'-" O H H W '-0" D O W FRONT VIEW FOR PUMP CLEARANCE O D SIDE VIEW Open impeller water pump with TEFC direct drive motor 8 High -Type Conveyorized Water Wash Booth s (0 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @.0 S.P. GPM WP-8-C WP-887-C WP-087-C WP-87-C WP-87-C WP-87-C WP-887-C WP-087-C -0 7-9 -0 7-7 -9 7-9 - 7-9 7 - -0 7-9 7 - -0 7-9 7 - -0 7-9 7-8 -0 7-9 7-0 -0 7-9 7 - - 0-7 0-7 -0 0-7 -9 9-0 0-7 -9-0 0-7 -9-0 0-7 -9 7-0 -7-9 9-0 -7-9 -0 0-7 -9. 800 7700 900 00 800 00 700 900 0 0 00 0 0 80 0 00 7. 7. 7. 0 0 00 0 97 9 00 9 7 800 Spray Systems building your booth the right way for all the right reasons

0 High -Type Conveyorized Water Wash Booth s (0 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) GPM @.0 S.P. WP-807-C WP-007-C WP-07-C WP-07-C WP-07-C WP-807-C WP-007-C 7-9 -9 7-9 - 9-9 7 - -0 9-9 7 - -0 9-9 7 - -0 9-9 7-8 -0 9-9 7-0 -0 9-9 7-7 - 0-7 -9 9-0 -7-9 -0 0-7 -9-0 0-7 -9 7-0 -7-9 9-0 -7-9 -0 0-7 -9 7. 7. 900 000 00 800 900 00 000 0 00 0 0 80 0 00 7. 7. 7. 0 0 77 0 80 7 7 700 800 High -Type Conveyorized Water Wash Booth s (0 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @.0 S.P. GPM WP-87-C WP-07-C WP-7-C WP-7-C WP-7-C WP-87-C WP-07-C 7 - -9 7-9 - -9 7 - -0-9 7 - -0-9 7 - -0-9 7-8 -0-9 7-0 -0-9 7-8 - - -9 0 - - -9-0 - -9-0 - -9 7 - - -9 9 - - -9-0 - -9 7. 7. 0 00 00 700 0000 000 000 8800 0 00 0 0 80 0 00 7. 7. 7. 0 0 7 80 780 7 97 800 900 Options / Accessories Access Doors Air Make-up Units Air Solenoid Valves Control Panels Constant Velocity Controls Energy savings stand-by/idle mode Stack Components Front Filter Doors Heaters / Infrared ing Magnahelic Gauges Observation Windows Pressurized Air Supply Plenums Centrifuge Stainless Steel Wash Chamber Spray Systems building your booth the right way for all the right reasons 7

less Type Water Wash Booths High static centrifugal exhaust fan Rated for.0 S.P. Belt driven, non-sparking blade General Purpose s UL/ETL Approved, -Tube, T-8 O H H W O W FRONT VIEW D O D SIDE VIEW The pumpless collection pan and back sections are fabricated from heavy and gauge galvanized steel. This feature allows our booths to resist corrosion, allowing your booth to last longer. The pumpless water wash booth uses a centrifugal high static exhaust blower, which combined with our unique baffle design creates extreme water turbulence. This turbulence causes the paint particles to be en trained in the water, which then is concentrated in the main sludge collecting area. The short depth of the eliminator section maximizes your shop s floor space. The water wash requires chemical treatment, which causes the paint particles to coagulate and sink to the bottom of the collecting pan for removal. Spray Systems recommends that you consult a reputable chemical supplier for the proper compound to suit the material being sprayed. 8 Spray Systems building your booth the right way for all the right reasons

8 High less-type Water Wash Booth s (00 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @ S.P. WNP-8 WNP-887 WNP-087 WNP-87 WNP-87 WNP-87 WNP-887 WNP-087-0 7-9 -0 7-7 -9 7-9 - 7-9 7 - -0 7-9 7 - -0 7-9 7 - -0 7-9 7-8 -0 7-9 7-0 -0 7-9 7 - - 8-9 -0 7-0 8 - - 9-0 8 - - -0 8 - -0-0 8 - - 7-8 - - 9-8 - - -0 9-0 - 8 7. 0 0 000 00 8000 900 00 800 00 000 00 0 97 9 00 9 7 800 0 High less-type Water Wash Booth s (00 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @ S.P. WNP-807 WNP-007 WNP-07 WNP-07 WNP-07 WNP-807 WNP-007 7-9 -9 7-9 - 9-9 7 - -0 9-9 7 - -0 9-9 7 - -0 9-9 7-8 -0 9-9 7-0 -0 9-9 7-7 - 0 - -0 9-0 - -0-0 0 - -0-0 0 - -0 7-0 - -0 9-0 - -0-0 0-9 -0 8 8 8 0 0 0 0 8000 0000 000 000 000 8000 0000 77 0 80 7 7 700 800 High less-type Water Wash Booth s (00 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @ S.P. WNP-87 WNP-07 WNP-7 WNP-7 WNP-7 WNP-87 WNP-07 7 - -9 7-9 - -9 7 - -0-9 7 - -0-9 7 - -0-9 7-8 -0-9 7-0 -0-9 7-8 - - - - - - - - - - - - 7 - - - 9 - - - - -9-8 8 0 0 0 0 0 0 900 000 00 800 900 00 000 7 80 780 7 97 800 900 Options / Accessories Access Doors Air Make-up Units Air Solenoid Valves Control Panels Constant Velocity Controls Energy savings stand-by/idle mode Stack Components Front Filter Doors Heaters / Infrared ing Magnahelic Gauges Observation Windows Pressurized Air Supply Plenums Centrifudge Stainless Steel Wash Chamber Spray Systems building your booth the right way for all the right reasons 9

Conveyorized less-type Water Wash Booth High static centrifugal exhaust fan Rated for.0 S.P. Belt driven, non-sparking blade General Purpose s UL/ETL Approved, -Tube, T-8 Conveyor opening custom designed to accommodate part specifications O H H W O W FRONT VIEW D O D SIDE VIEW 8 High less-type Conveyorized Water Wash Booth s (0 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @ S.P. WNP-8-C WNP-887-C WNP-087-C WNP-87-C WNP-87-C WNP-87-C WNP-887-C WNP-087-C -0 7-9 -0 7-7 -9 7-9 - 7-9 7 - -0 7-9 7 - -0 7-9 7 - -0 7-9 7-8 -0 7-9 7-0 -0 7-9 7 - - 8 - -0 7-0 8 - -0 9-0 8 - -0-0 8 - -0-0 8 - -0 7-8 - -0 9-8 - -0-0 9-0 -0 8 8 0 0 0 800 7700 900 00 00 00 700 900 00 0 97 9 00 9 7 800 0 Spray Systems building your booth the right way for all the right reasons

0 High less-type Conveyorized Water Wash Booth s (0 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @ S.P. WNP-807-C WNP-007-C WNP-07-C WNP-07-C WNP-07-C WNP-807-C WNP-007-C 7-9 -9 7-9 - 9-9 7 - -0 9-9 7 - -0 9-9 7 - -0 9-9 7-8 -0 9-9 7-0 -0 9-9 7-7 - 0 - - 9-0 - - -0 0 - - -0 0 - - 7-0 - - 9-0 - - -0 0-9 - 8 0 0 0 0 7. 7. 900 000 00 800 900 00 000 77 0 80 7 7 700 800 High less-type Conveyorized Water Wash Booth s (0 FPM Average Face Velocity meeting minimum NFPA- Code Requirements) @ S.P. WNP-87-C WNP-07-C WNP-7-C WNP-7-C WNP-7-C WNP-87-C WNP-07-C 7 - -9 7-9 - -9 7 - -0-9 7 - -0-9 7 - -0-9 7-8 -0-9 7-0 -0-9 7-8 - - -0 - - - - - -0 - - -0 7 - - -0 9 - - -0 - -9-0 8 8 8 8 0 0 0 0 00 00 700 0000 000 000 8800 7 80 780 7 97 800 900 Options / Accessories Access Doors Air Make-up Units Air Solenoid Valves Control Panels Constant Velocity Controls Energy savings stand-by/idle mode Stack Components Front Filter Doors Heaters / Infrared ing Magnahelic Gauges Observation Windows Pressurized Air Supply Plenums Centrifudge Stainless Steel Wash Chamber Spray Systems building your booth the right way for all the right reasons

Where Custom Designs Are Standard Booth Designs Open Face Booths Enclosed Booths -Cross Draft -Down Draft -Side Down Draft -Semi-Down Draft -Spray Bake Booth Types Bench Booths Blasting Enclosures Booth Extensions Conveyorized Spray Booths Customized Duct Designs Dry Filter/Industrial Booths Dust Collectors Grinding Booths Powder Booths -Recovery type -Non-Recovery type Truck and Large Equipment Booths Water Wash Spray Booths -Centrifuge Sludge Systems - Type -less Type Additional Options Air Make-up Units Booth Extensions Electrical Control Panels Flash Tunnels Ovens -Drying Enclosures -Convection (gas or electric) -Infrared (catalytic and electric) Turnkey and Custom Systems VOC Abatement Systems An American Tradition of Excellence The Spray Systems Advantage Located in Pomona, California since 978, our,000 square foot facility houses state-of-the-art machinery operated by dedicated and highly skilled team members. With more than years of experience in the design, fabrication and installation of spray booths, we can deliver to you the custom products, precision engineering, and responsive service to ensure your complete satisfaction whatever your company size, finished product specifications, production rates, or coating needs. Enjoy Our Wide Selection And Flexible Design We feature more than 00 booth design options for a wide variety of uses, and specialize in custom designs for the most unique of applications. To ensure full integration, our spray booth design will take into account all of your specific finishing requirements, including filtration, lighting, temperature, humidity and air flow. Discover Precise, Custom Tailored Engineering Solutions All booths are custom designed using the latest version of AutoCAD to ensure precision and prevent against interference fit early detection in the design stage prevents costly field modifications for you. We feature easy-to-read and easy-to-follow isometric assembly drawings. Each panel and component part is identified with a computer-generated label that precisely matches the CAD-produced, exploded-view assembly drawing all making installation efficient and trouble-free. Receive Unparalleled Personal Attention Spray Systems is committed to providing you dedicated service and support that place a high value on accountability and quality control. That means walking you through every phase of the design and installation process and tailoring our manufacturing to your specific requirements. We want to ensure the on-going success of your spray booth training, service, and operations. For us, quality of service doesn t end with the installation. Call For A Free Consultation Discuss Your Spray Booth Needs With Your Spray Systems Advisor 800 7-9 East Grand Avenue Pomona, CA 97 Phone 909-9 Fax 909-7 www.spraysystems.com Spray Systems building your booth the right way for all the right reasons