Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Similar documents
YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

The right trap for the right application.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Economical and simplified solutions that offer quality and optimum steam trap service.

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

THERMOSTATIC STEAM TRAPS

Yarway Narvik Steam Desuperheater Series 4300 TempLow

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Wide range of steam traps that provide consistent performance in less than perfect conditions.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

THE THERMOSTATIC STEAM TRAP

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Removal of Non-condensable Gases and Air Is Critical In A Steam System

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Hoffman Specialty General Catalog

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

LIQUIDATOR 450 SERIES

Liquid Drainers LIQUID DRAINERS

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Flo-Rite-Temp Instantaneous Steam/Water Heater

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Pump & Trap Combinations

Flo-Rite-Temp Instantaneous Steam/Water Heater

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Silhouette. Feedwater Heater. Boiler Feedwater

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Bringing Energy Down to Earth

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Series 1140 and 1141 Temperature Regulators

LIQUIDATOR UMT-TD Series Thermodynamic

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

THERMODYNAMIC STEAM TRAP

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

CD-33/CD-33S Controlled Disc Steam Traps

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

HEAT EXCHANGER FORMULAS & EXAMPLE

KEEP YOUR TRAP SHUT OR GET THE CONDENSATE OUT

THERMODYNAMIC STEAM TRAPS

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

How to Trap: Process Air Heaters

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

TEMPERATURE CONTROLLERS

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

Hydrocarbon & Chemical Processing Solutions

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SECTION METERS AND GAGES FOR PLUMBING PIPING

STEAM TRAPS

How to Trap: Trap Selection and Safety Factors

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

13-1. Temperature Regulator

STEAM CONSERVATION GUIDELINES

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

SECTION METERS AND GAGES FOR HVAC PIPING

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Steam Trap Selection

Niles Steel Tank Hot Water Generator Installation and Operation Manual

PIP PNE00004 Steam Trap Guidelines

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

How to Trap: Steam Tracer Lines

Thermostatic Radiator Valves (Caleffi)

A M E M B E R O F T H E K E N D A L L G R O U P

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

Chapter 2.3: Steam System

THERMODYNAMIC STEAM TRAPS

STEAM AND TRAP FUNDAMENTALS

Commercial Semi-Instantaneous Water Heaters

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

Top performance when the going gets tough

Steam System Best Practices Document No. 11

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Desuperheaters

MFP14 Automatic pumps for condensate and other industrial fluids

UNIFIED FACILITIES GUIDE SPECIFICATIONS

WATER HAMMER something that never should occur in a steam system

Operation & Maintenance Manual

How to Trap: Rotating Dryers Requiring Syphon Drainage

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Inverted Bucket Steam Traps

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

PL Series Premier Indoor Plenum Coils

MFP14 Automatic pumps. for condensate and other industrial fluids

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Transcription:

A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure assisted fail-open design Hardened stainless steel valve and seat Withstands superheat Efficient air and noncondensible removal Shuts tight on steam Compact and lightweight General applications Ideally suited for use on tubes, coils or heat exchangers, tanks or vats for heating liquids in either batch or continuous operation. technical data Size range: NPS ½, ¾ & 1 (DN 15, 20 & 25) Temperature: Up to 650 F [343 C] Pressure: Up to 600psi [41bar] Materials: Chrome moly steel, 416 Stainless steel End connections: NPT, socket weld, flanged valves.emerson.com 2017 Emerson. All Rights Reserved. VCTDS-03386-EN 16/09

Autoclave Steam Auxillary air vent Shell and tube heater Steam Hot process fluid out Cool process fluid in Trap Trap Full size pipe Guidelines for Typical Process Applications Depending on the application, a process steam trap will probably have to handle heavy startup loads, often followed by smaller running loads. The trap s function is to drain the process equipment and thus ensure that effective heat transfer is achieved (through latent heat). A few guidelines for optimum results include: Provide an adequate size process connection from equipment. Locate trap below the equipment (water runs downhill). Use good piping practice to ensure that clean condensate is presented to the trap. Include air vents and vacuum breakers as necessary for effective equipment operation. Why choose a thermostatic steam trap? Thermostatic traps react to changes in temperature and therefore discriminate very well between steam and cooler noncondensible gases. They can rapidly purge air from a system, especially on cold startups. These traps can be installed in various positions to match piping. Most commonly, actuation is by means of a bellowslike capsule filled with a vaporizing liquid. Thermostatic traps respond more slowly to changing conditions due to the heat energy of the condensate inside the trap which is slow to dissipate, thus causing some time delay. Insulating thermostatic traps aggravate this situation. To improve responsiveness, these traps should be mounted at the end of a cooling leg in an area where air can circulate freely and a distance from the collection pocket to match condensate load. Profile of a process application: Gravity drainage, shell and tube heat exchanger Tubes, coils or jackets are used with heat exchangers, tanks or vats for heating liquids in either batch or continuous operation, typical of shell and tube heaters. Equipment is generally protected from the weather and typically features a single coil. Heavy startup loads, followed by smaller running loads are to be expected, but without the extreme swings of weather-exposed equipment. Adequate air venting is most important as the equipment is often run on daily or weekly schedules. Tendency is for total shut-down of equipment following completion of run or batch. Lack of proper venting can cause condensate to be drawn back into the heat exchanger coils. Air in a heating system significantly reduces its efficiency. Air is a very poor conductor of heat and air filming on pipes and heat exchanger tubes reduces the heat transfer rate through their metal walls. Also, steam mixed with air contains fewer BTUs at a given pressure than steam alone. It is the function of a steam trap to aid in venting air from a steam system, but auxiliary thermostatic air vents are often required. Open to cooler air and closed to hotter steam, they greatly speed up the air purging process. When frequent startups and shutdowns are the rule, rapid air purging is a significant factor. Thermostatic traps are often favored for their good air handling characteristics on startup. 2

Pilot Operated Traps As the name implies, these traps are actuated by a thermostatic pilot valve which drives the main valve. The pilot, which is bellows actuated, is in essence a working mechanism similar to that used in bellows traps. Therefore the operating characteristics of pilot operated traps are basically the same as those of the pilot. Pilot operated traps are process traps that offer a dual capacity range. Small condensate loads are handled by the pilot and when the load exceeds its capacity, the main valve opens. An additional advantage of these traps is that they are relatively small in size and light-weight, yet can handle large quantities of condensate. They are a practical alternative to large heavy mechanical traps. Yarway pilot operated traps offer the following advantages: Simple construction Small size and weight Easy to maintain as installed Excellent air handling capability Energy efficient Bellows Technology Yarway offers two bellows technology products for process applications utilizing the FTE (Filled Thermal Element): Series 151 Dual Range Steam Trap Series AV-5 Thermostatic Air Vent With the Series 151 trap, the FTE acts as the pilot. This means that by opening or closing its internal valve as the condensate temperature changes the pilot determines whether the main valve is open or closed. If the condensate load is very low, then the total flow is passed through the pilot only. With the AV-5 Air Vent, the FTE thermostatic bellows opens and closes in response to temperature changes. Steam is prevented from discharging through the vent and only air and subcooled noncondensible or cool condensate can therefore be discharged. All Yarway bellows traps deliver consistent features such as: Three-year warranty Pressure assisted fail-open design Hardened stainless steel valve and seat Withstands superheat Efficient air and noncondensible removal Shuts tight on steam Compact and lightweight How it Works When condensate reaches a Series 151 trap, the FTE opens a pilot valve to allow limited flow. The main valve stays closed until the condensate load exceeds the capacity of the pilot valve; then the pilot valve opens the main valve, and both discharge at full capacity. At startup, both the pilot valve and the main valve are open for high-capacity discharge of air and condensate. And in normal operation, the pilot valve may drain condensate continuously, closing only in the absence of condensate. Direction of flow FTE filled thermal element Main valve Pilot valve 3

Series 151 Dual Range Process Traps (or High Capacity Air Vent) How to Size Required trap flow rate = Maximum expected condensate load (lb/hr) x Safety load factor. A safety load factor of 2-4 is usually recommended. Then select a trap from the flow rate chart. Do not size trap based on end connections. How to Order The Series 151 Dual Range Steam Trap is designed for use on both batch and continuous applications such as batch stills, autoclaves, reboilers, storage tanks, shell and tube heat exchangers and tank coils. The Dual Range Steam Traps are capable of handling high startup and running loads, and provide maximum air venting capability. There are two body styles and two internals available, the 151 angle and 151 in-line. There is a standard capacity internal and an H high capacity internal available. Both internals are interchangeable in both bodies. Applicable Codes and Standards Pressure ratings per ASME/FCI-69-1. Performance testing per ASME PTC-39-1. End connections per ASME B1.20.1 for threaded ends, per ASME B16.11 for socketwelding ends. Typical specification Traps shall be Dual Range type with a combination of welded stainless steel FTE thermostatic pilot valve and fluid-dynamic main valve. Construction shall be forged steel body and stainless steel bonnet with factory calibrated, stainless steel internals, self-adjusting for all pressures to 300 psi [21 bar]. Specify angle or in-line body. Ordering Specify trap size and series. Threaded end connections (socketwelded optional). Repair kits are interchangeable and are supplied as sets of matched parts (seat, seat gasket, screen and preassembled cage assembly). Pressure and Temperature Ratings (All pressures are gage) ASME Class 300 Max. Design Temp.: 750 F [400 C] Operating Pressure: 1-300 psi [0.07-21 bar] Max. Operating Temp.: 500 F [260 C] Condensate Capacity Near Steam Temperature (for steam trap sizing) 20,000 Trap inlet pressure, bar 0.1 0.5 1 5 10 10,000 All SN traps to 200 psi only 5,000 Steam trap flow rate, lb/hr 5,000 4,000 3,000 2,000 1,000 500 400 300 200 151-H High Capacity Pilot and Main Valve Flows 151 Standard Capacity Pilot - All Series 1,000 500 100 Steam Steam Trap trap Flow flow Rate, rate, kg/hr 50 100 1 2 4 6 10 20 40 60 100 200 300 Trap inlet pressure, psi NOTE: 151-H High Capacity Trap - use 1" pipe, valves and fittings. 4

Series 151 Dual Range Process Traps (or High Capacity Air Vent) 7 2 3 8 1A D Hex E for disassembly A 7 3 8 6 4 D Hex 2 1B A E for disassembly 6 4 Flow direction Detail S B 5 B F G 5 C See Detail S See Detail S C Socketweld end connections Parts and materials Item Part Material 1A Body 151 angle Body 151S/SN angle ASME SA-105, Carbon steel ASME SA182 316L Stainless steel 1B Body 151 In-line ASME SA 182 F11, Cr. Mo. 0.15% Maximum Carbon 1B Body 151S/SN ASME SA182 316L Stainless steel In-line 2 Bonnet ASTM A-582 416 Stainless steel 3 1 Cage assembly Stainless steel 4 1 Seat Stainless steel 5 1 Gasket, seat Monel 6 1 Screen 18-8 Stainless steel 7 Nameplate 302 Stainless steel 8 1 Gasket, bonnet Monel Teflon coated NOTES: 1. Denotes available repair kit. Dimensions, in. (mm) Fig. No. Size NPS (DN) A B C D E F G Weight lb. (kg) 151 Angle ¾ (20) 1⅞ (48) 1⅞ (48) 1¾ (44) 2¼ (57) 3 (76) 1.070 (28) ½ (13) 4½ (2) 151 In-Line ¾ (20) 2⅝ (67) 1 3 /16 (30) 4 5 /16 (110) 2¼ (57) 4 (102) 1.070 (28) ½ (13) 4½ (2) 151 In-Line 1 (25) 2⅝ (67) 1 5 /16 (33) 4⅝ (118) 2¼ (57) 4 (102) 1.335 (34) ½ (13) 5 (2.3) 5

Series AV-5 Thermostatic Air Vent Applicable Codes and Standards Pressure ratings per ASME/FCI-69-1. Performance testing per ASME PTC-39.1. End connections per ASME B1.20.1 for threaded ends. How to Order The Yarway Series AV-5 Thermostatic air vent has been designed to remove air and noncondensible gases from steam systems which otherwise would reduce efficiency of heat transfer during startup of normal operation. The AV-5 uses the HP version of the Filled Thermal Element (FTE) as the actuating mechanism. Capacities Typical specifications The Air Vent shall be a thermostatic type with a Filled Thermal Element (FTE) actuator with opening action of plug in a downstream direction, away from the seat, to provide a pressure-assisted fail-open operation. The body and internals shall be of stainless steel. Ordering Specify Air Vent size 1/2", 3/4", Series AV-5. Pressure and temperature ratings (All pressures in gage) Shell: ASME Class 600 [PN100] B16.34 Max. Operating Pressure: 600 psi [41 bar] Max. Operating Temp.: 650 F [343 C] Max. Test Pressure: 800 psi [55 bar] Assuming that a minimum inlet pressure of 15 psig to atmosphere, the air handling capacity of the AV-5 is 1.25 actual cubic ft/ min. This capacity is regardless of pressure or temperature changes because sonic velocity has been reached. Typical Installation Conduct discharge to safe location Preferred Installation Generally more sensitve to presence of air Acceptable Alternative Vent may cycle on some condensate 6

Series AV-5 Thermostatic Air Vent 2 3 4 6 5 1 C Dia. Flow direction B Hex across flats A Parts and Materials Item Part Materials 1 Body ASTM A582 416 Stainless steel 2 Outlet fitting ASTM A582 416 Stainless steel 3 Valve plug AISI 17-4PH Stainless steel 4 Cage assembly AISI 304 Stainless steel 5 Screen AISI 304 Stainless steel 6 Filled thermal element Stainless steel Dimensions, in. (mm) Size in. (DN) A Dimensions, in.(mm) B ½ (15) 3 (76) 1¼ (32) 1¼ (32) ¾ (0.3) ¾ (20) 3 3 /16 (81) 1½ (38) 1⅜ (35) 1 (0.5) C Weight lb. (kg) 7