EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD

Specifications Minimum Typical Maximum Unit

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-TC Thermocouple Data Logger with USB Interface

ELMTEC. Kattreppeln Königslutter / /

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

EL-OEM-3 OEM Packaged Voltage Data Logger


EasyLog Data Logger Series

EasyLog Data Logger Series

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

EL-OEM-3 OEM Packaged Voltage Data Logger

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Data Logging Solutions

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Introduction. OM-THA2

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

USB DATA LOGGER FOR TEMPERATURE AND RH HM9000

DataSheet. Thermocouple Logger

DataSheet. Thermocouple Logger

HOBO U14 Data Logger User Manual

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

portable gas analyser

Temperature & Humidity Monitoring For Museums & Heritage Product Guide.

Visit us at testo 835 Infrared and contact thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER MANUAL USB Multi-Function Datalogger Model RHT35

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Microtherm Heat Stress WBGT

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Sirius Technologies, Inc.

ALTAIR 5X Multigas Detector Product Specification

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Precision Temperature Humidity Meter DTH184DL User s Manual

LogTag TICT - is0 Tag

Temperature/Humidity Monitor. User s Manual

portable gas analyser

data logger DL200H DL200D DL200L

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

EASYLOG Temperature Label Series

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Precision Temperature Humidity Meter DTH184DL User s Manual

Tinytag Ultra Data Logger Manual

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Follett Performance Plus

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Refrigerator/Freezer Thermometer

Operating Instructions and Maintenance Manual

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Pocket CO2 Monitor & Data Logger SAN-0001

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

iminiplus PDF User Guide Version 2.0

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Instructions for use

Refrigerator/Freezer Thermometer

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Microprocessor Digital Thermometer

Batt-Safe Battery String Monitoring System

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

User Manual. Dryer Controller M720

Thermohygrometer with Single Type K Input and Superheat Function

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

Analog Room Pressure Monitor RPC Series

KM300 Carbon Monoxide Detection System Installation Manual

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Specification for On-Line UPS Battery Monitoring and Data Management System

PROTÉGÉ ZM SINGLE GAS MONITOR

USER MANUAL Digital CO Monitor Model CO30

Water Tank Level Monitor

MicroRay IR-100 NEW. Inspection MicroRay IR-100

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

IntelliPack : 800 Series

User Manual. Non-contact Infrared Thermometer.

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Gas Controller Module GC-06

Transcription:

High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EL-USB-2-LCD+ BAT 3V6 1/2AA FEATURES Higher accuracy sensor when compared to the EL-USB-2-LCD measurement range measurement range Dew point indication via Windows control software USB interface for set-up and data download User-programmable alarm thresholds for %RH & T Status indication via red and green LEDs High contrast LCD, with two and a half digit temperature and humidity display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium battery and Windows control software Environmental protection to IP67 This standalone data logger measures and stores up to 16,379 relative humidity and 16,379 temperature readings over and measurement ranges. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC s USB port and using the supplied software. Relative humidity, temperature and dew point (the temperature at which water vapour present in the air begins to condense) data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 1 year. The data logger is protected against moisture to IP67 when the protective cap is correctly fitted. Specifications Minimum Typical Maximum Unit Measurement range 0 100 %RH Repeatability (short term) ±0.1 %RH Relative Humidity Accuracy (overall error) ±2.0* ±4 %RH Internal resolution 0.5 %RH Long term stability 0.5 %RH/yr Measurement range -35 (-31) +80 (+176) C ( F) Temperature Repeatability ±0.1 (±0.2) C ( F) Accuracy (overall error) ±0.3 (±0.6) ±1.5 (±3) C ( F) Internal resolution 0.5 (1) C ( F) Dew Point Accuracy (overall error) ±1.1 (±2)** C ( F) Logging rate every 10s every 12hr - Operating temperature range*** -35 (-31) +80 (+176) C ( F) 1/2AA 3.6V Lithium Battery Life 1 Year * This specifies the overall error in the logged readings for relative humidity measurements between 10 and 90%RH. ** This specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100%RH at 25 C. *** At temperatures below -20 C (-4 F) the LCD will exhibit slower response times of approximately 10 seconds. Depending on sample rate, ambient temperature and use of LCD. Specifications liable to change without prior warning Issue 6 07/2012 S.L Applies to EL-USB-2-LCD+ Page 1 of 5

EL-WIN-USB (CONTROL SOFTWARE) Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista &7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (allows unlimited logging periods by overwriting the oldest data when the memory is full) DISPLAY AND STATUS FUNCTIONS The EL-USB-2-LCD+ features a high contrast LCD and two bi-colour LEDs. The LCD shows logged temperature and humidity values using seven segment numbers, along with annunciators. The LCD can also show information regarding the logging status. Maximum logged value symbol Relative Humidity symbol Negative symbol Minimum logged value symbol Reading Temperature scale The LCD shows six different recorded readings, which can be cycled through using the built-in push button. The most recent logged value, maximum logged value and minimum logged value can be displayed separately for humidity and temperature. In addition, logging and alarm status is shown using two high intensity LEDs. Specifications liable to change without prior warning Issue 6 07/2012 S.L Applies to EL-USB-2-LCD+ Page 2 of 5

LCD INDICATION Display Logger Status Explanation Delayed Start This is shown when the logger is set to start at a specific data and time* Push to Start This is shown when the logger is setup for Push to start logging Logging Stopped This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds LED FLASHING MODES * If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. EL-USB-2-LCD+ features 2 bi-colour LEDs; one LED represents temperature measurement, the other represents RH. Each is clearly marked on the logger. To save power, the status indication alternates between the two channels every 10 seconds. First you will see the status of the temperature logging, and 10 seconds later you will see the status of the RH logging, and so on. RH% C ( F) RH% C ( F) 10 seconds later Green double flash The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green single flash The data logger is currently logging. No alarm on the channel. Red single flash The data logger is currently logging. Low alarm on the channel. Red double flash The data logger is currently logging. High alarm on the channel. Green triple flash The data logger is full and has stopped logging. No alarm on the channel. RH% Red/ Green LED C ( F) Red/ Green LED Red triple flash The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Dual Red flash (every 60 seconds) The data logger battery is running low as its voltage has dropped below 2.9V Specifications liable to change without prior warning Issue 6 07/2012 S.L Applies to EL-USB-2-LCD+ Page 3 of 5

DIMENSIONS All dimensions in mm (inches) 126.0 (4.9) 22.1 (0.87) 25.3 (1.04) MEASUREMENT ACCURACY RH (%RH) ± 10 ± 8 ± 6 ± 4 ± 2 ± 0 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%RH) T ( C) ± 3.0 ± 2.5 ± 2.0 ± 1.5 ± 1.0 ± 0.5 ± 0.0-40 -20 0 20 40 60 80 Temperature ( C) Maximal RH-accuracy at 25 C per sensor type BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-2-LCD+ does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery you are ordering is press fit and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-2-LCD+ from the PC. Note: Leaving the EL-USB-2-LCD+ plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Specifications liable to change without prior warning Issue 6 07/2012 S.L Applies to EL-USB-2-LCD+ Page 4 of 5

CAUTION Exposure of the internal sensor to chemical vapours such as those produced by some plastics and foamed materials may interfere with the internal sensor and cause inaccurate readings to be logged, therefore ensure that the logger is used in a ventilated area i.e. air exchange is allowed. Exposure to extreme conditions or chemical vapours will require the following reconditioning procedure to bring the internal sensor back to calibration state. 80 C (176 F) at < 5% RH for 36h (baking) followed by 20-30 C (70-90 F) at>74%rh for 48h (re-hydration) High levels of pollutants may cause permanent damage to the internal sensor. THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: Accuracy (overall error) Part No Function Range Readings Battery Battery Life* Typ. Max. EL-USB-1 Temperature ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) ±0.5ºC (±1ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG EL-USB-2 EL-USB-2+ EL-USB-2-LCD Temperature with rechargeable battery Temperature, humidity & dew point Increased accuracy temperature, humidity & dew point Temperature, humidity & dew point with LCD -20 to +60 C (-4 to +140 F) ±1ºC (±2ºF) 32,510 Lithium Ion ±0.5ºC (±1ºF) ±3%RH ±0.3ºC (±0.6ºF) ±2.0%RH ±0.5ºC (±1ºF) ±3.0%RH ±2ºC (±4ºF) ±6.0%RH ±1.5ºC (±3ºF) ±4.0%RH ±2ºC (±4ºF) ±6.0%RH 1 month (rechargeable) 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year Increased accuracy temperature, ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) EL-USB-2-LCD+ humidity & dew 16,379 3.6V ½AA 1 year point with LCD ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A ±3 secs/24 hrs 32,510 3.6V ½AA 1 year EL-USB-TC Thermocouple (J, K and T- type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months -200 to +1350ºC (-328 to +2462ºF) (K-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe -200 to +1190ºC (-328 to +2174ºF) (J-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months included -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) ±1ºC (±2ºF) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) *Depending on logging rate, ambient temperature, and use of alarm LED 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com ±1.5ºC (±3ºF) ±4.5%RH 7 days N/A N/A Specifications liable to change without prior warning Issue 6 07/2012 S.L Applies to EL-USB-2-LCD+ Page 5 of 5