OSRAM 1/25/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Similar documents
1/24/01 SYLVANIA Process Heat THREADED INLINE HEATERS , , , , , ,

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Serpentine II & Serpentine VI Air Heaters

Hot Air Tool Air Heaters

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

SKORPION Process Air Heater

The best choice in hot air tools

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Bringing the Heat

Industrial Air Heater Product Guide

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

HotPoly Tote Tank / IBC Heaters (TTH Series)

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Flameless Electric Air Heaters: Heater Style Application & Selection Guide

Desiccant / Pump Dehumidification System. Model Operating Manual

Inline Heater for Solvent or Gas. Installation and Operation Manual

Installation, Operation and. Maintenance Instructions

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Horizontal Bottle Cooler Installation and Operation Manual

MaxLite LED High Bay Fixtures

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

Installation and Operations Manual

MODEL HBX-1 P/N 3G59332

Portion Bag Cheese Warmer

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

OPERATION MANUAL MODEL 8102 ACCELEROMETER

Condensate Pump. Installation and Safety Instructions CP-16 CP

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

User Guide AutoSealer 1001

(HSTAT Series) Instruction Manual

GAS MONITOR Model Model

SF180 Installation Instructions

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

USER S OPERATING AND INSTRUCTION MANUAL

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

RP, GP, XP Pro Series Installation Instructions

IN020 Rev F Page 1 of 8

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Please Read and Save These Instructions.

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

TORRID MARINE YACHT QUALITY Since Owner s Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

DBF 4XL Dryer Booster Fans

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

20 High Velocity Fan with 135 Tilt Head

CABINET INFRARED HEATER

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Macurco HD-11 Hydrogen Gas Detector

Instruction Manual. Part No Revised September 2004

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

TL-105 COLUMN HEATER

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Zeus Extreme Owner's Manual

Installation & Maintenance Instructions

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

GETZ MANUFACTURING PART # CYLINDER DRYER

Air Pump Up to 800 gallons

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4010/4020/4021 Series Humidity Sensors

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

MaxLite LED Vapor Tight Linear Fixture

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

CD6102 / CD6102 OC / CD6102-2

Model 9001, Alarm

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Frosty Factory of America, Inc.

Compressed Air Dryer

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

LEAVE THIS MANUAL WITH HOMEOWNER

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Model 9001, Alarm

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Ultrasonic Reflective Sensor

HS Series Installation & Operating Instructions RadonAway

Superdryer Dehumidifiers

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INSTALLATION AND OPERATING MANUAL

Transcription:

SERPENTINE II, VI HOT AIR TOOLS SERPENTINE II HOUSING 029763 SERPENTINE II ELEMENTS 029765, 029766, 029767, 060418 SERPENTINE VI HOUSING 057088 SERPENTINE VI ELEMENTS 040291, 040292, 061429, 056548 *Handle not available FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Description Compact and efficient process air/inert gas heater, capable of producing exit temperatures up to 1400 F (760 C) with standard elements, and up to 1500 F with the Two-Stage elements. The heater unit consists of two parts - a replaceable serpentine-coil electric heater element, which fits into a stainless steel triple-pass exchanger housing. This special housing uses the incoming air to cool the outer shell prior to passing through the heater element. This not only minimizes radiant heat losses but provides a cool outer shell, to minimize burn injury for operators who accidentally contact the heater. Two heater sizes are available; the Serpentine II (wattages from 2000 to 3600W) and the Serpentine VI (wattages from 5000 to 8000W). If operated correctly, element life will be greater than 5000 hours. Specifications SERPENTINE II ELEMENTS (used with housing 029763) PART NUMBER WATTS VOLTS AMPS PRESSURE (PSI) LENGTH A OD B 029765 2000 240 8.3 25 8.20 (208mm) 0.63 (16mm) 029766 2800 240 11.7 25 8.20 (208mm) 0.63 (16mm) 029767 3600 240 15 25 8.20 (208mm) 0.63 (16mm) 060418 3600 (two-stage) 240 15 25 8.20 (208mm) 0.63 (16mm) 131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 1

SERPENTINE VI ELEMENTS (Used with housing 057088) PART NUMBER WATTS VOLTS AMPS PRESSURE (PSI) LENGTH A OD B 040291 5000 240 20.8 25 10.88 (276mm) 1.25 (32mm) 040292 6000 240 25 25 10.88 (276mm) 1.25 (32mm) 061429 6000 240 25 25 10.88 (276mm) 1.25 (32mm) (two- stage) 056548 8000 240 33.3 25 10.88 (276mm) 1.25 (32mm) HOUSING ASSEMBLIES PART SERPENTINE A B C D E NUMBER TYPE 029763 SERP II 1.6 (40mm) 9.0 (229mm) 10.0 (254mm) 0.7 (18mm) 3 / 8 NPT 057088 SERP VI 2.1 (54mm) 11.9 (302mm) 12.9 (327mm) 1.4 (35mm) 3 / 4 NPT ELEMENT HOUSING 131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 2

Safety! SHOCK HAZARD Only qualified individuals should install this heater and related controls. Follow all applicable electrical codes and use proper wiring.! BURN/FIRE/EXPLOSION HAZARD Do not use with or near explosive or reactive gases. Avoid contact with the side, or exposure to the exit-end, during or soon after operation. DO NOT USE NEAR VOLATILE OR COMBUSTIBLE MATERIALS. Precautions! Use filtered air. Avoid grease, oil, or oil vapors, corrosive or reactive gases which will damage heater.! Operate at safe voltages as shown on the PERFORMANCE CURVES. Excess voltage will cause premature failure.! Always have sufficient airflow through the heater before applying power. Otherwise element will overheat very quickly, and burn out. NOTE: A thermocouple cannot detect temperatures if there is no flow turn on flow before applying power, even when a controller with a thermocouple is being used.! Use phase angle fired power controllers. On-off controllers may shorten heater life (or burnout element).! For closed-loop control, use exposed junction type K thermocouple within one inch of the heater exit.! For closed-loop control, use a temperature controller with a fast sampling period (500ms) and minimal overshoot. Installation " Securely mount the heater. " Connect the filtered air source to the heater. " If a thermocouple is used, ensure that it is located within one inch from the heater exit. Start-up " Reference the PERFORMANCE CURVES section for operational parameters before attempting to operate heater(s). " Turn on air supply and adjust to desired flow/pressure. " If using a closed loop system, turn on power to the temperature and power controller, then set the desired temperature on the temperature controller. If using an open loop system, increase power to the heater through the power controller until the desired temperature is attained. Performance Curves The attached performance curves show exit air temperatures at different airflows and voltages. Pressure readings (longer dashed lines) are measured at the inlet to the heater with no entrance or exit restrictions. Solid lines indicate safe, normal-life operating conditions. The shorter dash lines indicate marginal, shorter-life operating conditions leading to premature burnout. With a known flow (or pressure) at the heater entrance, follow the flow (or pressure) line across until it meets the desired temperature curve. Drop a line straight down to intersect the x-axis. This point, along the Heater volts true RMS axis, represents the voltage required to generate the desired exit air temperature at the chosen flow rate (inlet pressure). 131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 3

131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 4

131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 5

131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 6

131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 7

Warranty SYLVANIA warrants that all products to be delivered hereunder will be free from defects in material and workmanship at the time of delivery. SYLVANIA's obligation under this warranty shall be limited to (at its option) repairing, replacing, or granting a credit at the prices invoiced at the time of shipment for any of said products. This warranty shall not apply to any such products which shall have been repaired or altered, except by SYLVANIA, or which shall have been subjected. SYLVANIA shall be liable under this warranty only if (A) SYLVANIA receives notice of the alleged defect within sixty (60) days after the date of shipment; (B) the adjustment procedure hereinafter provided is followed, and (C) such products are, to SYLVANIA s satisfaction, determined to be defective. THE WARRANTY SET FORTH IN THE PRECEDING PARAGRAPH IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY. The information contained in this manual is based on data considered to be true and accurate. Reasonable precautions for accuracy has been taken in the preparation of this manual, however SYLVANIA assumes no responsibility for any omissions or errors, nor assumes any liability for damages that may result from the use of the product in accordance with the information contained in this manual. Please direct all warranty/repair requests or inquiries to the place of purchase, and provide the following information, in writing: (A) (B) (C) Order number under which products were shipped Model/Serial Number of product Reason for rejection PRODUCTS CAN NOT BE RETURNED TO SYLVANIA WITHOUT AUTHORIZATION. Replacement, repair, or credit for products found to be defective will be made by the place of purchase. All products found to be not defective will be returned to the Buyer; transportation charges collect or stored at Buyers expense. 131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072 8