E S F I P D G DB A(1) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Similar documents
AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

E XEIPI IO E KATA TA H

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

FH052EAMT FH070EAMT E S F I P D G R DB A(2) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH RUSSIAN E HNIKA

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO MANUEL D INSTALLATION INSTALLATIONS-HANDBUCH

OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG π Ã

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

Function Controller MCM-A100

E S F I P D G R A DB A(3) E HNIKA RUSSIAN

Wireless Remote Controller

UH175GCM UH175GZM. Ventiltype Klimaanlage (Kühlen und Wärmen) KÏÈÌ ÙÈÛÙÈÎfi T appleô AÂÚ ÁˆÁÔ (æ ÍË Î È ÚÌ ÓÛË )

Air Conditioner. user installation & manual manual. imagine the possibilities

Safety Precautions WARNING INSTALLING THE UNIT POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

Outdoor unit MH18AP1(P2)X MH19AP1(P2)X MH24AP1(P2)X MH26AP1(P2)X

Type ACH1800E ACH2400E CH18ZA CH24ZA CH18CA CH24CA

Air Conditioner. installation manual. imagine the possibilities

INSTALLATION MANUAL. System Air Conditioner (Cooling and Heating) Cassette Type Series CH070CAV1 CH105CAV CH140CAV DB A(1) ENGLISH ESPAÑOL

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

INVERTER SPLIT - TYPE

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

Installation Instructions

Split-type Room Air Conditioner (Cool) Aire acondicionado doméstico sistema Split (Refrigeración) Climatiseur de type Séparé (Refroidissement)

Air conditgioner. conditioner. User Installation manual/installation manual ARHVSD. future reference.

INSTALLATION MANUAL. R-410A Split Series. Models. Installation manual R-410A Split series. Installationsanleitung Split-Baureihe R-410A

Installation Instructions

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Installation Instructions

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E. Model name: Slim Duct Type.

42PHW / 42PHQ 42PHQ...K

ROOM AIR CONDITIONER INSTALLATION MANUAL

[FLARE CONNECTION TYPE] ATTENTION

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. R410A Split Series

1. BEFORE INSTALLATION

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

INSTALLATION MANUAL. R410A Split Series. Models FVXS25FV1B FVXS35FV1B FVXS50FV1B. Installation manual R410A Split series

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Choosing the installation site. Installation. 07 Choosing the installation site

Installation Instructions

Installation Instructions

Window-Type Air Conditioner

Installation Instructions

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

INSTALLATION MANUAL. R410A Split Series. Models ATX20J2V1B ATX25J2V1B ATX35J2V1B. Installation manual R410A Split series

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXN50KV1B FTXN60KV1B. R410A Split Series

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Split-type Air-Conditioner

AIR CONDITIONER (MULTI-SPLIT TYPE)

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

INSTALLATION MANUAL. R410A Split Series

Installation manual for room air conditioner

1. BEFORE INSTALLATION

Split-type Air-Conditioner

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

Installation Instructions

Split-type Air-Conditioner

Installation Instructions

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

Air conditioner. Installation manual AC777KN4DCH

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. R410A Split Series

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

SPLIT-TYPE ROOM AIR CONDITIONER

GDDEM10 DEHUMIDIFIER

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

R410A SPLIT SERIES DC INVERTER

MAX INSTALLATION MANUAL AQN09VFUAGM AQN12VFUAGM AQN18VFUAGM AQN24VFUAGM AQN36VFUAGM

SUPER MODULAR MULTI SYSTEM AIR CONDITIONER

INSTALLATION. Glass Panel Doors (select models) CAUTION

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

AIR CONDITIONER BRANCH BOX INSTALLATION MANUAL. For authorized service personnel only. [UTP-PY03A] [UTP-PY02A] PART NO.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. Installation manual Manuel d installation Manual de instalación

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

Dishwasher. Installation manual DW60M9990AP

Transcription:

INSTALLATION MANUAL MANUAL DE LA INSTALACIÓN MANUEL D INSTALLATION MANUALE INSTALLAZIONE MANUAL DE INSTALAÇÃO INSTALLATIONSHANDBUCH E XEIPI IO E KATA TA H Indoor unit MH023FWEA MH026FWEA MH035FWEA MH052FWEA ENGLISH ESPAÑOL FRANÇAIS PORTUGUÊS E HNIKA DEUTSCH ITALIANO Free Joint Multi Air Conditioner (Cool and Heat) Acondicionador de aire libre del empalme multi (Refrigeración y Calefacción) Climatiseur Free Joint Multi (Refroidissement et Chauffage) Aria condizionata Free Joint Multi (Raffreddamento e Riscaldamento) Free Joint Multi ar condicionado (Refrigeração e Aquecimento) Free Joint Multi Klimaanlage (Kühlen und Wärmen) ÔÏÏ appleïfi ÏÈÌ ÙÈÛÙÈÎfi ªË ÓËÌ Ï ıâúë ŒÓˆÛË (æ ÍË - ÚÌ ÓÛË ) E S F I P D G DB98-24189A(1)

Safety Precautions You should take the following safety precautions when using your air conditioner. WARNING If you don t follow the safety precautions, you may get the risk of an electric shock, injury or death. The manufacturer or qualified service personnel must install this air conditioner. Unplug the electric power before repairing, installing or cleaning. INSTALLING THE AIR CONDITIONER The unit should not be installed by the user. Ask the dealer or authorized company to install the units except room air conditioners for the U.S.A and Canada area. If the unit is installed improperly, water leakage, electric shock or fire may result. Mount with the lowest moving parts at least 2.5m above the floor or grade level. (If applicable) The manufacturer does not assume responsibility for accidents or injury caused by an incorrectly installed air conditioner. If you are unsure about installation, contact an installation specialist. When installing the built-in type air conditioner, keep all electrical cables such as the power cable and the connection cord in pipe, ducts, cable channels e.t.c to protect them against liquids, outside impacts and so on. POWER SUPPLY AND CIRCUIT BREAKER If the power cord of this air conditioner is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The unit must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit breaker. An all pole disconnection from the power supply must be incorporated in the fixed wiring with a contact opening of >3mm. Do not use an extension cord with this product. If the unit is equipped with a power supply cord and a plug, the plug must be accessible after installation. The air conditioner must be installed in accordance with national wiring regulations and safety regulations wherever applicable. E-2

ENGLISH Contents PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner... 4 Air Conditioner and Accessories... 7 INSTALLING THE AIR CONDITIONER Fixing the Installation Plate... 8 Purging the Indoor Unit... 8 Connecting the Assembly Cable... 9 Assigning Address to Indoor Unit... 10 Additional Functions... 10 Installing and Connecting the Drain Hose of the Indoor Unit... 11 Changing Direction of the Drain Hose... 11 Installing and Connecting the Assembly Pipe of the Indoor Unit... 12 Cutting or Extending the Pipe... 13 COMPLETING THE INSTALLATION Fixing the Indoor Unit in Place... 14 Wiring wired Remote Controller(Optional)... 15 Final Checks and Trial Operation... 16 Providing Information for User... 16 Troubleshooting... 17 E-3

PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: Combustible gases Saline air Machine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions, first consult your dealer. Indoor Unit There must be no obstacles near the air inlet and outlet. Install the indoor unit on a surface that can support its weight. Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the recommended length of 7.5 metres to be respected. Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance. Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite. Make sure that the water dripping from the drain hose runs away correctly and safely. You have just purchased a Free Joint Multi air conditioner and it has been installed by your installation specialist. This device must be installed according to the national electrical rules. Max input power & current is measured according to IEC standard and input power & current is measured according to ISO standard. CAUTION More than 2 indoor units should be installed when you use Free Joint Multi air conditioner. E-4

PREPARING THE INSTALLATION ENGLISH MH040FXEA2/MH052FXEA2 The split type, 1-way cassette, slim duct type indoor units can be installed together. Piping outside diameter Indoor unit 023/026/035 Outdoor unit MH040FXEA2 MH052FXEA2 Power supply Ø, V, Hz 1, 220-240, 50 Unit 023/026/035 Outside diameter Liquid 1/4 Gas 3/8 MH052FWEA indoor unit cannot be connected to the MH040FXEA2 and MH052FXEA2 outdoor units. MH040FXEA2 outdoor unit cannot be connected to the following indoor unit combination. 026 + 035 / 035 + 035 200 mm or more 100 mm or more 160 mm or more (h) (H) 600 mm minimum 300 mm minimum 300 mm minimum A B 600 mm minimum Main power switch Piping length and the height Dimension Composition 1 Room max length 20 m A, B 2 Room total max length 40 m A+ B Max height between indoor unit & outdoor unit 15 m (H) Max height between indoor units 7.5 m (h) E-5

PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner (Continued) MH068FXEA4 / MH080FXEA4 The split type, 1-way cassette, duct type indoor units can be installed together. Indoor unit 023/026/035/052 Outdoor unit MH068FXEA4 MH080FXEA4 Power supply Ø, V, Hz 1, 220-240, 50 Piping outside diameter Outside diameter Unit 023/026/035 052 Liquid 1/4 1/4 Gas 3/8 1/2 200 mm or more 100 mm or more 160 mm or more (h) (H) 600 mm minimum 300 mm minimum 300 mm minimum A B C D 600 mm minimum Main power switch Piping length and the height Dimension Composition 1 Room max length 25 m A, B, C, D 2 Room total max length 30 m A+ B 3 Room total max length 45 m A + B + C 4 Room total max length 70 m A + B + C + D Max height between indoor unit & outdoor unit 15 m (H) Max height between indoor units 7.5 m (h) E-6

PREPARING THE INSTALLATION Air Conditioner and Accessories ENGLISH The following accessories are supplied with the air conditioner. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control Wired remote Controller cables (1) Batteries for Remote Control (1) Owner s Instruction Installation Manual The following connection accessories may be supplied, depending on the option. If they are not supplied, it is recommended that you collect them together before starting to install the air conditioner. Assembly Piping, Ø6.35mm (1) Assembly Piping, Ø9.52mm (1) ( 023/026/035 ) Assembly Piping, Ø12.70mm (1) ( 052 ) PE T3 Foam Tube Insulation(1) Vinyl Tape (1) Drain Plug (1) Rubber Leg (4) Pipe Clamps A (3) Pipe Clamps B (3) Cement nail (6) M4 x 16 Tapped Drain Hose, Putty 100g (1) Screws (6) length 2m (1) If these accessories are supplied, they are located in the accessory box. E-7

INSTALLING THE AIR CONDITIONER Fixing the Installation Plate Before fixing the installation plate to the wall or window frame, you must determine the position of the 65-mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected from the: Right Left Underside (right) Rear (right or left) Pipe hole (Ø65mm) 023/026/035 (Unit : mm) Installation plate 30mm 1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards. 2 If you fix the indoor unit to a... Follow step(s)... Wall 3. Window frame 4 to 6. 3 Fix the installation plate to the wall giving attention to the weight of the indoor unit. 97 156 14 If you mount the plate on the concrete wall with anchor bolts, the anchor bolts must not be projected by more than 20mm. 052 (Unit : mm) 190 134 26 4 Determine the positions of the wooden uprights to be attached to the window frame. 5 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit. 6 Attach the installation plate to the wooden uprights using tapping screws as seen in the picture. Purging the Indoor Unit On delivery, there may be inert gas inside the indoor unit. You should purge the gas from the indoor unit before connecting the assembly pipe. Unscrew the caps at the end of each pipe. Result: All inert gas exhausts from the indoor unit. To prevent dirt or foreign substance from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the pipes. E-8

INSTALLING THE AIR CONDITIONER Connecting the Assembly Cable ENGLISH The indoor unit is powered from the outdoor unit via the assembly cable. 1 Extend the assembly cable if necessary. 2 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit. 3 Remove the screw securing the connector cover. 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable such as figure. Each wire is labelled with the corresponding terminal number. Indoor unit 1(L) 2(N) F1 F2 5 Pass the other end of the cable through the 65 mm hole in the wall. 6 Replace the connector cover, carefully tightening the screw. 7 Close the front grille. 8 For further details on how to plug the other end of the assembly cable into the outdoor unit, refer to installation manual of the outdoor unit. Outdoor unit 1 2 E 1 2 E Earth terminal Earth terminal F1 F2 F1 F2 1(L) 2(N) F1 F2 E-9

INSTALLING THE AIR CONDITIONER Assigning Address to Indoor Unit Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. Cover PCB 1 2 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit. Remove the screw securing the cover PCB. 3 Remove the cover PCB. 4 The address of the indoor unit is assigned by adjusting MAIN(SW02). SW02 MAIN 5 6 The MAIN address is for communication between the indoor unit and the outdoor unit. Therefore, you must set it to operate the air conditioner properly. It is required to set the RMC address if you install the wired remote controller and/or the centralized controller. 7 If you install optional accessories such as the wired remote controller, centralized controller, etc. see an appropriate installation manual. 8 Refer to the outdoor unit installation manual for the details. Additional Functions K5 K6 K7 K8 Compensation for lost temperature in heating operation Reduces the difference between an actual room temperature and a sensed temperature by the air conditioner when heating. Switch No. Switch ON Switch OFF SW06 K5 2 C compensation 5 C compensation E-10

INSTALLING THE AIR CONDITIONER Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose for the indoor unit, you should check if condensate draining is adequate. When you pass the drain hose through the 65-mm hole drilled in the wall, check the following. ENGLISH 5 cm less Ditch The hose must NOT slant upwards. The end of the drain hose must NOT be placed under water. To install the drain hose, do the following. Do NOT bend the hose in different directions. Keep a clearance of at least 5cm between the end of the hose and the ground. Do NOT place the end of the drain hose in a hollow. 1 If necessary, connect the 2-meter extension drain hose to the drain hose. 2 If you use the extension drain hose, insulate the inside of the extension drain hose with a shield. 3 Fit the drain hose into 1 of 2 drain hose holes, and then fix the end of the drain hose with a clamp tightly. If you don t use the other drain hose hole, block it with a rubber stopper. 4 Pass the drain hose under the refrigerant pipe keeping the drain hose tight. 5 Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. Shield Drain hose Extension drain hose The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to installation manual of the outdoor unit for further details. Changing Direction of the Drain Hose You can select the direction of the drain hose depending on the place you want to install the indoor unit. 1 Detach the rubber cap with the flyer. 2 Detach the insulation(foam-pe). 3 Detach the drain hose by pulling it and turning to the left. 4 Insert the drain hose by fixing them into the groove of the drain hose and the outlet of the drain pan. 5 Insert the insulation(foam-pe) to prevent water leakage. 6 Stick the rubber cap with the screwdriver by turning it to the right until it fixes to the end of the groove. Insulation Screws hole Screw Drain hose Drain pan outlet Rubber cap E-11

INSTALLING THE AIR CONDITIONER Installing and Connecting the Assembly Pipe of the Indoor Unit There are 2 refrigerant pipes of different diameters: The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner. You must extend the pipe using the assembly pipe. (Optional) The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall: Right (A) Left (B) A B Underside (C) C Rear 1 Cut out the appropriate knock-out piece on the rear of the indoor unit unless you connect the pipe directly from the rear. 2 Smooth the cut edges. 3 Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench applying the following torque. Outer Diameter Torque (kgf cm) 6.35 mm 140~170 9.52 mm 250~280 12.70 mm 380~420 If you want to shorten or extend pipes, refer to page 13. 4 Cut off the remaining foam insulation. 5 If necessary, bend the pipe round along the bottom of the indoor unit. Then pull it out through the appropriate hole. The pipe should not be projected from the rear of the indoor unit. The bending radius should be more than 100mm. 6 Pass the pipe through the hole in the wall. 7 For further details on how to connect to the outdoor unit and purge the air, refer to installation manual of the outdoor unit. The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test; refer to installation manual of the outdoor unit. E-12

INSTALLING THE AIR CONDITIONER Cutting or Extending the Pipe ENGLISH 7.5 metres of piping is supplied with the air conditioner(optional). This length can if necessary be: Extended to a maximum length Shortened as required If more than 7.5 metres of piping is required: The assembly cable must also be extended Refrigerant must be added to the circuit by an approved installer; otherwise, the indoor unit may freeze 1 Make sure that you have the required tools available (pipe cutter, reamer, flaring tool and pipe holder). 2 If you wish to shorten the piping, cut it using a pipe cutter, taking care to ensure that the cut edge remains at a 90 angle with the side of the pipe, and referring to the illustrations below for examples of edges cut correctly and incorrectly. Oblique Rough Burr 90 O O x x x 3 To prevent any gas from leaking out, remove all burrs at the cut end of the pipe, using a reamer. 4 Slide a flare nut on to the pipe and modify the flare. Outer Diameter(D) Depth(A) 6.35 mm 1.3 mm 9.52 mm 1.8 mm 12.70 mm 2.0 mm 5 Check that the flaring is correct, referring to the illustrations below for examples of incorrect flaring. x x x x Inclined Damaged Surface Cracked Uneven Thickness 6 Align the pipes to be connected and tighten the flare nuts first manually and then with a torque wrench, applying the following torque. Outer Diameter Torque(kgf cm) 6.35 mm 140~170 9.52 mm 250~280 12.70 mm 380~420 7 For further details on how to connect up to the outdoor unit and purge the circuit, refer to installation manual of the outdoor unit. E-13

COMPLETING THE INSTALLATION Fixing the Indoor Unit in Place After checking for a gas leak in the system, you can insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. 1 To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit. 2 Wrap the refrigerant pipe and the drain hose in the rear of the indoor unit with the absorbent pad. Wind the pipe and hose three times to the end of the indoor unit with the absorbent pad. (20-mm interval) 3 Wind the pipe, assembly cable and drain hose with insulation tape. Installation plate 4 Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so as not to be projected from the rear of the indoor unit. 5 Hook the indoor unit on the installation plate and move the unit to the right and left until it secures in place. 6 Wrap the rest of the pipe with vinyl tape. 7 Attach the pipe to the wall using clamps (Optional). E-14

COMPLETING THE INSTALLATION Wiring Wired Remote Controller (Optional) ENGLISH Connect the power cable, which is connected with the outdoor unit and supplied by another source, making sure that the power cable terminal should not be changed. The F3 and F4 communication cable may be cross-connected, however, it is recommended that they are connected to the corresponding F3 and F4 terminal. Indoor unit PCB CN33 (Blue) CN32 (White) Accessory in the indoor unit case 1(L) 2(N) F1 F2 Indoor Unit Terminal Block Accessory in the remote controller F1(F3) F2(F4) V1 V2 Wired Remote Controller (Optional) K1 K2 K3 K4 Change DIP switch in the indoor unit PCB SW05 K1 : ON OFF E-15

COMPLETING THE INSTALLATION Final Checks and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. 1 Check the following. Strength of the installation site Tightness of pipe connection to detect a gas leak Electric wiring connections Heat-resistant insulation of the pipe Drainage Earth conductor connection Correct operation (follow the steps below) 2 Press the button and check the following. The indicator on the indoor unit lights on. The airflow blade opens and the fan gears up for operation. 3 Press any button and check the following. The appropriate indicator lights on and the air conditioner operates according to the selected mode or function. 4 Press the button and check the following. The airflow blades work properly. Providing Information for User After finishing the installation of the air conditioner, you should explain the following to the user. Refer to appropriate pages in the User s Manual. 1 How to start and stop the air conditioner 2 How to select the modes and functions 3 How to adjust the temperature and fan speed 4 How to adjust the airflow direction 5 How to set the timers 6 How to clean and replace the filters When you complete the installation successfully, hand over the User s Manual and this Installation Manual to the user for storage in a handy and safe place. E-16

COMPLETING THE INSTALLATION Troubleshooting The error indicated on the display panel of indoor unit ENGLISH Display Explanation Communication errors in the indoor unit Communication errors in the outdoor unit Indoor unit room temperature sensor error (Open/Short) Inlet pipe temperature sensor error in the indoor unit heat exchanger (Open/Short) Remark Outlet pipe temperature sensor error in the indoor unit heat exchanger (Open/Short) Indoor unit heat exchanger in temperature sensor detached Indoor unit heat exchanger out temperature sensor detached Indoor unit heat exchanger in & out temperature sensor detached Indoor fan motor malfunction More than 2 indoor units cool and heat simultaneously EEPROM error EEPROM option setting error Communication cable and power cable misconnected The number of indoor unit mismatched Compressor discharge sensor error (Open/Short) Outdoor unit error E-17

THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H Y KEYH KATA KEYA THKE A O : ELECTRONICS G-18 Printed in Korea