Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

Similar documents
Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Florida Building Code 2010

NFPA 72 Code Changes vs 2013

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Changes in NFPA

Bold items are particular to the City of Euless

Questions/Comments for Richard Roux from Webinar on 7/11/13

Frequently Asked Questions

INSPECTION AND TESTING FORM

The 2013 National Fire Alarm and Signaling Code

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

2018 NICET Code Transition Changes

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

1.3 REFERENCE STANDARDS

Great Lakes Building Systems, Inc.

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

NFPA Changes

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

Circulation Report for SIG-TMS Comments Document # 72

FIRE & LIFE SAFTEY STANDARD

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

Fire Alarm System Inspection and Testing Report

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

SECTION 915 CARBON MONOXIDE DETECTION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

MNEC NFPA 72 WHITE PAPER

Proposed Changes to NFPA

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Residential Care Facilities Requirements

Unified Fire Authority - Fire Prevention Bureau

HIGH-RISE RETROFIT ORDINANCES - NO and NO

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Agency for Health Care Administration

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

Fire Alarm System Fundamentals


Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

AGENDA NFPA TECHNICAL COMMITTEE ON NOTIFICATION APPLIANCES. Report on Comments Meeting, October 13-14, Richmond Marriott, Richmond, VA

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Date Issued: December 14, 2017 Revision: 2.1

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

Recent Revisions and Proposed Key Changes to Fire Code

APPENDIX H (DESIGN SUBMISSION CRITERIA)

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

THE BASICS OF FIRE ALARM PLAN REVIEW

NY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

Functional Challenges of Integrating Mass Notification and Fire Alarm Systems

Fire Alarm and Life Safety System Inspection Certificate

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Fire Prevention Coffee Break Training. February 2017

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

2019 COURSE CATALOG (rev )

NFPA 101 SAF-RES PUBLIC COMMENTS

SECTION : FIRE ALARM & DETECTION SYSTEMS

Case Study Media Contact Beth Welch, or

El Reno Fire Department Fire Alarm Plan Review Worksheet

Overview of Fire Alarm Provisions Based on the 2012 IBC, IFC and NFPA 72, 2013 Edition

Large Family Daycare Guideline

Home Fires Are Common, Deadly and Preventable

Combining Old and New Systems in Existing Buildings and Other Retrofit Tales. By Paul Jewett CFAA Technician Number 11

Full Service Central Station Fire Alarm Listing Evaluation

DEALING WITH FIRE SAFETY

Residential Based Care Facility Guidelines

For additional information regarding R-3.1 residential care facilities please contact (951)

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

Melrose Fire Department

THE GENERAL ASSEMBLY OF PENNSYLVANIA SENATE BILL

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Report on First Revisions with Statement June 2014 NFPA 101

Transcription:

NFPA 720 2015 Summary Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment TM, 7Oct14 CODE: Title, Standard, not Code Consistent with recent trend at NFPA, this document emphasized that the enforcement comes through adoption by State or local government and the Authority Having Jurisdiction (AHJ). When writing a specification for a fire alarm which includes CO detectors, include the statement, Carbon Monoxide detectors, equipment and notification devices shall strictly follow NFPA 720-2015. CODE: Preface, Large parts extracted from NFPA 72-2013, Fire Alarm and Emergency Signaling Code NFPA 72 explicitly excludes carbon monoxide detectors and referencesnfpa-72. When the text of NFPA-720 is not clear, it may be explained by the corresponding section in the NFPA-72, especially the NFPA-72 Handbook. CODE: 1.2.1, Purpose of this Standard is to warn occupants of the presence of carbon monoxide in time to escape. The first common use of CO detectors was to turn on fans where auto exhaust fumes are intermittently present. Arguably, that function closely matches the alarm function and Life-Safety considerations (dual power sources, supervised wiring) are appropriate for fan control also. Use professional judgment in the application of Life Safety systems. CODE: 1.4, Equivalency - no Standard limitation on using equivalent or superior devices. This is CYA talk. NFPA has been sued by smoke-and-mirrors salesmen and wants to avoid future problems. Be very careful in accepting new technology which appears too good to be true. CODE: 1.4.1, Equivalency - Submit documentation to AHJ for acceptance. In all cases, not just equivalency, the AHJ makes the final decision. At the end of the day, the measure of project success is getting a Building Permit, then an Occupancy Permit. Coordination with the AHJ is recommended. CODE: 3.2.1, Approved means accepted by the AHJ. CODE: 3.2.3, 4, Labeled and Listed mean documentation satisfactory to the AHJ. For many years, designers assumed that listed meant UL listed. The lawsuits, mentioned previously, caused NFPA to become very circumspect in this section.

Require UL-listing in your specification if you think that provides higher quality and reliability. CODE: 3.3.1, Definition of Acoustically Distinguishable Space (ADS) NFPA is moving towards field testing of intelligibility on voice notification systems. This is a camel s nose in the tent. Watch this area closely. It is expected that there will be future requirement, but it is near-impossible today, even though intelligibility meters are being marketed. CODE: 3.3.6, Definition of Carbon Monoxide Detector Be careful here. NFPA defines control unit, control function interface device and warning equipment separately. Use the term Carbon Monoxide Detector System in your specification to include all the necessary pieces-and-parts. CODE: 3.3.23, Signal - Alarm, Supervisory, Trouble These are the same concepts as used in fire alarm smoke and heat detectors. For fire alarms, we count on contractors and suppliers with decades of experience and continuing relationships with the AHJ. It is possible to get former garage door salesmen selling CO systems. Keep the boilerplate in the specification regarding Alarm, Supervisory and Trouble Signals. Look for these features in the submittals. CODE: 4.3.2, Manufacturer s instructions This standard requires that manufacturer s application and installation instructions be followed. Get a copy of the manufacturer s application and installation instructions as part of the submittal. CODE: 4.4.2, Installer qualifications. This standard requires that the installer (or his supervisor) be experienced and certified or factory-trained. Require submission of installer name and qualifications in the submittal. CODE: 4.5.3.2, Two independent and reliable power supplies I haven t taken apart my Home Depot residential CO monitor, but I am guessing it does NOT contain a backup battery. This section applies to both commercial and residential units. List this in your specification; check for it in the submittal. CODE: 4.5.5.2, Branch circuit requirements

Dedicated circuit; marked as CO supply; accessible only to qualified personnel; (not required to be painted red, but still a good idea) CODE: 4.5.6.1.1, Backup power starts in 10-sec and lasts 4-hr Fire alarm backup power is much more stringent Find out if occupants are expected to evacuate in the event of a power failure. If NOT, then make sure that PRIMARY power is on the generator and SECONDARY power is available if the generator fails. CODE: 4.5.10.6, 12-hour generator fuel supply on hand When I specify a generator, I call for fuel for 60%load for 3-days. The 12-hour requirement would not affect me. Since old diesel fuel goes toxic and requires handling as a hazardous material, the 12-hour requirement may be meaningful in a well-thought-out design. CODE: 4.6, Distinctive Signals for Alarm, Supervisory and Trouble, common to fire alarm OK Be careful. Common audible is OK. Separate visual, with big tags, are required. Check the boiler plate in your specifications for compliance. CODE: 4.7.3.6, deactivated alarm shall maintain audible trouble notification This is also in the current fire alarm code. Check the boiler plate in your specifications for compliance. CODE: 4.8.5, deactivated supervisory notification shall automatically restart after 24-hours This is also in the current fire alarm code. Check the boiler plate in your specifications for compliance. CODE: 4.11, Detector performance and limitations 85 110% supply voltage; 32 120F temp, manufacturer s published limits That 32F minimum is a problem for unheated parking garages. System Sensor sells a combined fire / CO detector rated 32 100F, 15 90% RH. Gamewell, same. Notifier, same. http://www.cpsc.gov//global/research-and-statistics/technical-reports/home/carbon- Monoxide/COAlarmConformanceReportFY%202013ClearedTechReport.pdf 1 of 6 models tested passed all tests. Temp and humidity were the problems. Temp standard was 32 120F. Siemens FDOTC241 is rated down to 0F. CODE: 4.12.5, Zoning Required It is important to group the annunciation of detectors so that alarms correspond to evacuation zones. In a voice notification system, it is possible to be selective in sending people in one

location to one exit and others to a different exit. Standard fire alarm boilerplate requires zoning. Check your specification. CODE: 4.14, Monitoring Integrity. Carbon monoxide alarms must have supervised wiring and devices. Check standard spec boilerplate; do not accept residential units. CODE: 4.14.2, Completion Documents An 8-page forms is required. Normally, I don t check this because the wording is that the forms must be submitted to the AHJ and they are very careful with fire alarms. As carbon monoxide alarms are relatively new, the same standard of care may not be present. Include this in spec but also ask for an installation sticker on the outside of the cabinet. A later section says that all CO detectors must be replaced after 10-years. You need to know when to start counting. CODE: 5.2.3, Separate Systems CO alarm need not be integrated into fire alarm, but conflicting alarms are forbidden. Think very carefully before designing stand-alone systems. CODE: 5.3.3.1, Nonrequired carbon monoxide detection systems shall meet the requirements of this standard. There is no such thing as almost an NFPA CO alarm. Some Owners insist on adding a CO detector to a plant SCADA system or BAS system. They are not life-safety rated. CODE: 5.8.2.5.1, Signal transport equipment Routers and servers used in the carbon monoxide alarm system shall be listed for carbon monoxide alarm service Again, there is liability in attempting to roll your own carbon monoxide alarm system. CODE: 5.8.2.9, permitted silencing of alarm sounder if panel continues to indicate alarm Indication of false alarms is permitted so long as a reminder remains CODE: 5.8.3, Interconnection with Household Carbon Monoxide Alarms Building alarm can trip household alarm; Household alarm or trouble can be logged to building system. Household cannot trip building evacuation alarm.

CODE: 5.8.4.5, Mass notification speakers or emergency communications systems can be connected to the carbon monoxide alarm system, in accordance with NFPA 72 NFPA 72 permits non-supervised public address for alarms. I disagree strongly. CODE: 5.8.5.3.7, application limitations, 32 100F, 10 95% RH except for specifically designed units, and these do exist see 4.11 comment CODE: 5.8.5.3.9, Protection During Construction protection from dust required. Most detectors come with caps for protection during construction. Include in specification. CODE: 5.8.6.2, Notify building or zone only There is an exception for notifying only the zone. Read carefully. CODE: 5.8.6.3, Notification zones layout detection zones per evacuation plan CODE: 5.8.6.5.1, Carbon monoxide audible alarm - 100mS on, 100mS off, 100 ms on, 100mS off, 100 ms on, 100mS off,continue Fire alarm audible 500mS on, 500mS off, 500mS on, 500mS off, 500mS on, 500mS off, 1500mS off, continue (NFPA 72 18.4.2.1) CODE: 5.10, Off-Premises Signals Remote monitoring must include alarm, trouble and supervisory Include in specification CODE: 5.12, Low-Power Radio (Wireless) Systems Not covered here. I have had extremely bad experience with wireless systems - unexpected dead zones and unreliable operation. Apply at your own risk. CODE: 6.3.3.2, Visual notification devices must not be labeled, FIRE. Separate notification device and label for CARBON MONOXIDE. Covers, guards and substantial mounting recommended.

CODE: 6.4.8, Intelligibility, required but not verification. CODE: 6.4.5.5, Alarm sound level 10dB above ambient. NFPA 72 18.4.3.1, fire alarm sound level 15dB above ambient CODE: Table 6.5.5.4.1() Room Spacing for Wall-Mounted Visible Appliances Complex table. Seems to reduce to 40-ft c-c for typical 75cd strobe Same table in 72HB-2013 CODE: 6.5.5.5.5, Not more than 15-ft from end of corridor and not more than 100-ft c-c in corridor Same requirements in 72HB-2013 CODE: X.X.x.x.x.x,, Commercial / Industrial spacing for CO Detectors, 70-ft x 70-ft NFPA 720-2015 does not address commercial / industrial spacing of CO detectors. The reference in 4.11 says to follow manufacturer s published limit. Commercial CO detector published data says 5,000 sa-ft coverage per detector. Check manufacturer s application data for the design basis detector for your project. Prepare plan drawings which use this data. CODE: 6.5.5.4.2, Strobes shall be synchronized Unsynchronized strobes can initiate epileptic seizures. Come installers aren t careful. It is just a jumper lead between strobe driver (main panel) units. Same requirements in 72HB-2013. Please sync between fire alarm and CO alarm. CODE: 6.9.2.1, Private mode This is a special provision for occupancies where evacuation is difficult or impossible, as prisons and hospitals. It is legal to notify only the guards or nurses, but there are requirements in this section. CODE: 7.1, off-premises monitoring Off-premises monitoring is not required, but, if implemented, rules apply.

CODE: 8.7.2, Replace alarms when end-of-life signal activates or 10-years from date of manufacture. The standard does not limit this requirement to residential units. Note, date of manufacture, not date of installation. CODE: 8.8.1.1, Testing by qualified technician every 3 years This is limited to household carbon monoxide detection systems, but places a burden on residents, landlords and public housing administrators. CODE: 9.3.3, number of household CO detectors not stated The adopting or enforcing body makes this determination CODE: 9.4.1.1, CO alarms required outside each sleeping unit, on every occupiable level This does not relieve installers from complying with local or State requirements for more. Interconnecting so one detector trips all alarms is recommended. Required in 9.6.4. CODE: 9.4.2.2.1.1, Mild to Severe Hearing Loss, 520 Hz at 75dB There will be a discussion of which locations require this. More is safer. CODE: 9.4.2.2.1.2, Moderately Severe to Profound Hearing Loss This topic is recognized but not covered here. CODE: 9.6.2.1, 85 db minimum Chapter 9 is HOUSEHOLD, but household is not defined within NFPA 720. NFPA 72 Handbook defines household as one- and two-family dwellings and certain occupancies such as sleeping rooms or guest suites or hotels, and the dwelling units of apartment and condominium buildings. CODE: 9.5.3.1, Battery only Must be tested monthly and provide warning at end-of-life. CODE: 9.6.4, CO detectors must be interconnected to sound all alarms.

(end NFPA 720-2015 Summary)