Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

Similar documents
4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Temperature Controllers

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Nov 08 PRODUCT SPECIFICATION SHEET

UDC100 Universal Digital Controller Specifications

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Process & TeMPerATUre UniversAl input DigiTAl MeTers

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Software Version 2.01 LEVEL MONITOR MODEL 220

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

UDC 700 Universal Digital Controllers and Indicator Specifications

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

02/11/2015

F4 Process Controller Installation and Operation Guide

Model Q45P/R. ph/orp Monitor...

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Series Temperature Controller Instruction Sheet

SHIMADEN DIGITAL INDICATORS

Specification , July 2015

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Model 1062 Environment Monitor

02/11/2015

Model Q45P/R. ph/orp Monitor...

HPLC Column Ovens and Temperature Controllers

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Complete packages with Software and Controller

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD

DT968C C.T. BATH CONTROLLER

SX65 and SX75. Electronic process controllers

Advanced Test Equipment Rentals ATEC (2832)

JENCO ELECTRONICS, LTD.

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

3500/61E & 3500/67E Temperature Monitor

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

FAHM Co. Temperature Transmitter PTT74 Series

Low Temperature Zirconia Oxygen Analyzer

Operating Instructions tico Temperature Indicator

Instruction Manual Model A

Temperature Solutions Line Card

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

APPLICATION DATA SHEET

Dissolved Oxygen Analyzers

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Alarm Modules Section E

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

APPLICATION DATA SHEET

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

/8 DIN Level Indicator

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Analog Input Module IC670ALG630

INSTRUCTION MANUAL T-154. DOSSENA s.n.c. Via Federico Barbarossa s/n Cavenago di Adda tel Fax:

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

LC1350 Level Controller

Electronic Temperature Controller 70304,

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Datasheet: K-22 LO Sensor

ELEKTRON ELEKTROLABORATORIJSKE - VISOKOTEMPERATURNE PEĆI. The view from the back of the oven

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Sitron s CF Line of Flow Switch Monitors

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Mark 25 Ultrapure Water Conductivity Analyzer

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Table of Contents SECTION PAGE

BlueSpin Magnetic Hotplate Stirrer

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Liquid Helium Level Instruments

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

RTD TEMPERATURE SENSING SYSTEM

Series Multipoint Recorder. Features. The future in Data Recording Technology is available today

eed quality electronic design USER s MANUAL

The A-series Eletta Flow Monitor with local indication and analog output

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Temperature Data Logging

Alpha Engineering Company

INSTRUCTION MANUAL T-935-FO ANALOGUE. TECSYSTEM S.r.l. TECSYSTEM S.r.l. protection relays. 12 protection relays

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

Clamp-on ultrasonic flow and energy meters for liquids

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL

Transcription:

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-V MSI-16-H Model Wise Description: Sr. No Model Description (XX = No. of channel ) 7.2 MSI-16C-XX 7.3 MSI-16A-XX Microprocessor based 16 channel Temperature / Process Scanner with common high / low alarm relays. (XX = 04,08,12,16 points) Microprocessor based 16 channel Temperature / Process Scanner with common high / low alarm relay along with per channel high / low alarm LED indication and transistor drivers for external relays. (XX = 04,08,12,16 points) Size in Horizontal &Vertical (w x h x d) mm H-(192 x 96 x 200) V-(96 x 192 x 200) H-(192 x 96 x 200) V-(96 x 192 x 200) Description: Libratherm offers Microprocessor based Temperature / Process Scanner Model MSI-16-H and MSI-16-V, which is most suitable for continuous and accurate monitoring of temperature or process values at maximum 16 different locations in the same or different system. Additional useful features of common and individual high or low alarms make these scanners versatile for control and alarm applications. MSI-16 accepts thermocouples or RTD (Pt-100) sensors, as inputs. The temperature is indicated within the accuracy of ± 1 o C or ± 0.1 o C of the specified input range, in spite of non-linear behavior of the standard thermocouple and RTD (Pt-100) sensors. The Linearized indication is achieved by software linearization technique. The models are available for 4, 8, 12, 16, 20,24, 28 and 32 channels. 1

The standard features include SCAN/HOLD, and SKIP the unwanted Channel facility and manual increment of the channel number using front panel membrane keyboard. Other than input from temperature sensors MSI-16 series also accepts (4-20) ma or (0-5) or (0-10) Volt signals from process transmitters for pressure, flow, ph, ORP, level etc... Features: Available in standard ½ DIN sizes. Highly accurate and sturdy in operation. Elegant looks and Very easy to operate. High quality membrane keypad Facility of common and individual high/low alarms. Application: Heat treatment, Large funnel Furnace / Oven Temperatures at various locations Transformer oil temperature Power plant Food processing ovens Plastic / Packaging industry Environmental chambers, Cold Storage and Chilling plants Laboratory equipment.etc. Technical Specifications: Design Microprocessor based( 8 bit) with 12 bit ADC No. Of channels 4, 8, 12 or 16. Input Refer input and range selection table as given below. (each channel can be of same or different input type as per user s requirement) Accuracy Resolution Display Open Sensor/Input Indication Display Scan Rate Sampling Rate Skip/Hold Facility Key board Common Relay Outputs Individual Alarm Better than ± 0.1 o C, ± 1 o C / 0.1 or 1 UOM - Software Linearized. (Subject to specified input and range). 0.1 o C, 1 o C, 0.1 or 1 UOM (As per users requirement) 4 digits each 0.5" 7-segment red LED to display process and Alarm Set values. 2 digit 0.5" 7 segment red LED for channel number Display shows Flt-1 or Flt-2 and all outputs will be turned low. 1 to 99 sec (programmable through front panel keyboard) 125mS (All 16 channels will be scanned in 2 seconds). Available through key board in configuration mode 8 x 1 membrane keypad for data entry 2 nos. potential free change over contact (1 each for high and low output but common for all the channels) 2 per channel i.e. 32 open collector outputs to drive external relay cards. 2

Outputs LED Indication Size (WxHxD) Panel Cutout Alarms Can be configured for LL, HH, LH, HL) L Low and H High. 32 LED's in the front indicating status of each alarm output 192 x 96 x 200 mm ( MSI-16-H) or 96 x 192 x 200 mm. (MSI-16-V) 186 x 92 mm., or 92 x 186 mm + 0.5 mm Supply 230VAC / 110 VAC ± 10% (10VA), 50/60Hz or 24VDC @ 500mA Enclosure Metallic with ABS bezel and polycarbonate front fascia Note : Specifications are subject to change without notice due to continuous upgradation. For requirement of only 8 channel, we recommend our model MSI-804 Input and Range Selection Table: Code Input Range A1 NA Subject to input A2 J type : Fe/Con thermocouple 0 to 760 o C A3 K type : Cr/Al thermocouple 0 to 1372 o C A4 R type : Pt/PtRh13% thermocouple 0 to 1768 o C A5 S type : Pt/PtRh10% - thermocouple 0 to 1768 o C A6 B type : Pt30%Rh/Pt6%Rh thermocouple 200 to 1820 o C A7 T type : Cu/Con thermocouple 0 to 350 o C A8 E type : NiCr/CuNi thermocouple 0 to 900 o C A9 C type : W5%Re/W26%Re thermocouple 0 to 2300 o C A10 D type : W3%Re/W25%Re thermocouple 0 to 2300 o C A11 G type : W/W26%Re thermocouple 0 to 2000 o C A12 N type : Ni-Cr-Si/Ni-Si-Mg 0 to 1300 o C A13 Pt-100 (Alpha = 0.00385) DIN 43760 0.0 to 400.0 o C A14 Pt-100 (Alpha = 0.00385) DIN 43760-150.0 to 200.0 o C A15 Pt-100 (Alpha = 0.00385) DIN 43760 0 to 400 o C A16 4-20mA 0 to 3500 unit A17 4-20mA -1500 to +2000 unit A18 0-10VDC 0 to 3500 unit A19 0-10VDC -1500 to +2000 unit 3

Ordering Information: Model MSI-16C MSI-16A No. of channels 04 08 12 16 C Common HI / LO Alarms A - With individual HI / LO Alarms Examples: A- Channel Input (Use above table) CH-1- (Select from A2 to A19) CH-2- (Select from A2 to A19) CH-3- (Select from A2 to A19) CH-4- (Select from A2 to A19) CH-5- (Select from A2 to A19) CH-6- (Select from A2 to A19) CH-7- (Select from A2 to A19) CH-8- (Select from A2 to A19) CH-9- (Select from A2 to A19) CH-10- (Select from A2 to A19) CH-11- (Select from A2 to A19) CH-12- (Select from A2 to A19) CH-13- (Select from A2 to A19) CH-14- (Select from A2 to A19) CH-15- (Select from A2 to A19) CH-16- (Select from A2 to A19) B- Supply C- Size (W x H x D) mm. B1-(230 VAC) B2-(110 VAC) B3-(24 VDC) C1-(192 x 96 x 200) C2-(96 x 192 x 200) Model No. of channel A- Channel Input B- Supply C- Size MSI-16C 04 CH-1- (A3) CH-2- (A3) CH-3- (A3) CH-4- (A3) MSI-16A 08 CH-1- (A2) CH-2- (A2) CH-3- (A2) CH-4- (A2) CH-5- (A15) CH-6- (A15) CH-7- (A15) CH-8- (A15) MSI-16C 12 CH-1- (A3) CH-2- (A3) CH-3- (A3) CH-4- (A5) CH-5- (A5) CH-6- (A5) CH-7- (A13) CH-8- (A13) CH-9- (A13) CH-10- (A13) CH-11- (A16) CH-12-(A16) B1-(230 VAC) C1-(192 x 96 x 200) B2-(110 VAC) C2-(96 x 192 x 200) B3-(24 VDC) C1-(192 x 96 x 200) 4

Example Ordering Code Description 1 MSI-16C-04-CH-1-(A3)-B1-C1 CH-2-(A3) CH-3-(A3) CH-4-(A3) 2 MSI-16A-08-CH-1-(A2)-B2-C2 CH-2-(A2) CH-3-(A2) CH-4-(A2) CH-5-(A15) CH-6-(A15) CH-7-(A15) CH-8-(A15) 3 MSI-16C-12-CH-1-(A3)-B3-C1 CH-2-(A3) CH-3-(A3) CH-4-(A5) CH-5-(A5) CH-6-(A5) CH-7-(A13) CH-8-(A13) CH-9-(A13) CH-10-(A13) CH-11-(A16) CH-12-(A16) 4 channel scanners with common high and low alarm outputs, with all channels calibrated for K type thermocouple, working on 230VAC and horizontal model. 8 channel scanner with individuals high and low alarm outputs, with 1 st 4 channel calibrated for J type thermocouple and next 4 channel calibrated for RTD ( 0 to 400 o C), working on 110VAC and vertical model. 12 channel scanner with common high and low alarm outputs, with 1 st 3 channel calibrated for K type thermocouple, next 3 for S type thermocouple, next 4 channel for calibrated for RTD ( 0.0 to 400.0 ⁰C ) and last channel for 4-20mA (0 to 3500 counts) working on 24VDC and horizontal model. 5