Ecotoxicological assessment of nanoparticle-containing acrylic copolymer dispersions in fairy shrimp and zebrafish embryos

Similar documents
Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

SPECTRAL INSTRUMENTATION

Compact Raman spectrometer system for low frequency spectroscopy

Laser Diagnostics and Optical Measurement Techniques

RAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS

Temperature dependent Components within the Pyroelectric Detector

Towards CARS Endoscopy

Distributed Temperature Sensing

The FEL Facility Optical Diagnostics and FEL Characterization

Current Research Topics in Optical Sensors and Laser Diagnostics

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

RAMAN SPECTROSCOPY See more, faster than ever before

Microscopy from Carl Zeiss

Gas Temperature Measurements with High Temporal Resolution

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Remote Detection of Leaks in Gas Pipelines with an Airborne Raman Lidar. Strategic Insights, Volume VII, Issue 1 (February 2008)

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

Understanding total measurement uncertainty in power meters and detectors

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Guidance on Video Smoke Detection Technology (VSD)

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Picosecond anti-stokes generation in a photonic-crystal fiber for interferometric CARS microscopy

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

E11 Tests of trace gas concentration multicomponent. monitoring system

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

EXTENDING RAMAN INTO THE THz REGIME

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Autonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll

High Sensitivity Explosives Detection using Dual-Excitation- Wavelength Resonance-Raman Detector

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

WHAT IS LASER ULTRASONIC TESTING?

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Y003 Multi-offset Seismic Acquisition Using Optical Fiber Behind Tubing

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Dated 15-Dec-2000; J. Schilz, subject to change

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

On-chip optical detectors in Standard CMOS SOI

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

Hygrometry. The art or science of humidity observation

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Distributed Rayleigh scatter dynamic strain sensing above the scan rate with optical frequency domain reflectometry

An Introduction to Mass Spectrometry

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Laser Safety Products. Edition 20

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Exhibitor Listing S48 S11 S46 S22 S24 S32

Design of CO Concentration Detector Based on Infrared Absorption Method

ENHANCED VISION - INFRARED 1

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Pyroelectric Infrared Sensor PIR

Stimulated Raman Scattering Microscopy with a Robust Fibre Laser Source

Standard Operating Procedure Raman Microscope - Renishaw invia

The design of the human body infrared thermometer

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

Measurement of Light. Photosensors

CCD and CID solid-state detectors

An FT-NIR Primer. NR800-A-006

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

AEROSOL SPECTROMETERS

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

The Optical Scattering Calibration System at SNO+ IOP 2015

Remote Gamma Imaging of High Dose Environments

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

SOLUTION MINING RESEARCH INSTITUTE

Exercise 1: IR Transmission and Reception

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Compact Portable QEPAS Multi-gas Sensor

Fact File 66. Guide to Beam Smoke Detectors

Introduction to Fiber Optic Sensing

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

The IR FOCUS technology

Leakage detection using fiber optics distributed temperature monitoring

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

APPLICATION NOTE. 1. Introduction Application Considerations

Transcription:

Electronic Supplementary Material (ESI) for Environmental Science: Nano. This journal is The Royal Society of Chemistry 2017 Supplementary Information to: Ecotoxicological assessment of nanoparticle-containing acrylic copolymer dispersions in fairy shrimp and zebrafish embryos Table of contents 1 Introduction to Raman scattering microscopy as relevant for the specific study...1 2 Preliminary tests to optimise the preparation of fairy shrimp and zebrafish and microscopy settings...3 3 Semi-quantitative SRS to determine limit of detection...5 4 Quality control values for acute aquatic toxicity tests...6 5 Abbreviations to Supplementary Information...6 6 References to Supplementary information...6 1 Introduction to Raman scattering microscopy as relevant for the specific study Adapted from: Moger et al.; 1 Galloway et al.; 2 Alfonso-Garcia et al.; 3 Zhang et al. 4 Spontaneous Raman scattering (applied as pre-tests in the present study to select the most appropriate test materials) involves two beams (or photons, fields, or laser), an incident beam, called pump (or signal) beam, and a scattered beam, called Stokes (or idler) beam. Assuming that the molecule under investigation is initially in its ground state, the Raman scattered beam is of lower frequency than the incident beam. The energy difference between the two beams corresponds to the vibrational energy of the molecule, which is left in a vibrationally excited state after the light-matter interaction. In spontaneous Raman microscopy, the intensity of laser light scattered from a sample is measured as a function of the energy shift (Raman shift) with respect to the incident beam, in units of wavenumbers (cm -1 ). This energy shift is a result of interactions of the incident beam with Raman-active chemical bonds within the sample. The Raman spectrum consists of narrow peaks which correspond to particular chemical bonds, thereby forming a unique fingerprint of the particular sample. The intensity of the Raman scattered light is directly proportional to the number of vibrationally active chemical bonds, which often allows straightforward quantitative analyses. However, spontaneous Raman scattering provides only weak signals (and it further requires long acquisition times >100 seconds). Typical Raman cross-sections per molecule range from 10-25 to 10-30 cm 2, whereas typical cross-sections obtained, e.g. in fluorescence 1

microscopy, range from 10-16 to 10-17 cm 2. In theory, the signal-to-noise ratio could be improved by increasing the intensity of the incident laser beam. However, in practise, this rapidly causes photo-thermal damage to biological samples. Coherent Raman scattering (CRS), i.e. Coherent anti-stokes Raman Scattering (CARS) or Stimulated Raman Scattering (SRS), uses visible or near-infrared excitation light. By contrast to spontaneous Raman scattering, in CRS techniques, two (or more) incident beams, instead of only one, drive the molecule, i.e. the pump beam (or signal beam) and the Stokes beam (or idler beam). These two beams are made to overlap perfectly in time and space before being directed into a microscope, with lenses focussing the beams onto the sample under investigation. This results in a non-linear dependence on the incident light, and coherent Raman signals are produced. Thereby, the detected Raman signal is sufficiently strong to obtain contrast from even relatively weak Raman-active molecular vibrations, that would not be detectable by spontaneous Raman scattering. Coherent anti-stokes Raman Scattering (CARS; applied in the present study to confirm the presence of nanoparticle-containing polymer dispersions in biological samples) derives its contrast from intrinsic molecular vibrations in a sample. The use of infrared excitation gives CARS an increased depth penetration over conventional optical microscopy, which removes the need for sample sectioning, and it further minimises sample damage. By simultaneously illuminating the sample with two excitation wavelengths with the frequency difference chosen to match the vibrational frequency of chemical bonds within the desired sample component, CARS generates a strong anti-stokes signal which is used as image contrast. This beam (signal) varies with the square of the number of Raman-active chemical bonds under investigation. Thereby, CARS is especially suited for the investigation of polymers with a high concentration of repeating chemical bonds. However, the CARS signal contains an inherent non-resonant background, which results in a distorted spectral profile as compared to the spontaneous Raman scattering spectrum. Anti-Stokes signal, anti-stokes Raman scattering: By contrast to Stokes Raman scattering, anti-stokes Raman scattering implies that the molecule loses energy to the emitted beam so that it has a higher energy than the incoming light. Stimulated Raman scattering (SRS; predominantly used method of the CRS part of the present study, applied to investigate the uptake and bioavailability of the nanoparticle-containing polymer dispersions): In SRS, the energy difference between the pump and Stokes fields is transferred to the molecule for vibrational excitation. This stimulated excitation leads to subtle changes in the excitation field. The SRS signal 2

appears at the same wavelengths as the excitation fields. It is manifested as a loss to the pump beam (stimulated Raman loss) or a gain to the Stokes beam (stimulated Raman gain). SRS requires the use of ultrafast lasers with high peak powers (thereby providing excellent signal-to-noise contrast) but low time-averaged powers at the sample (thereby preventing photo-thermal sample damage). SRS offers the benefit of the chemical selectivity of spontaneous Raman scattering without the problem of low sensitivity, combined with the benefits of confocal microscopy, such as 3D sectioning capabilities and sub-cellular resolution. While the enhanced sensitivity of SRS allows investigating materials that would not be detectable with spontaneous Raman scattering, the spectral profile obtained with SRS is identical to that of spontaneous Raman scattering. This enables straightforward comparisons between the two techniques. SRS is inherently a non-linear technique since the signal intensity of SRS does not scale linearly with the concentration of the test material under investigation. Nevertheless, SRS measurements allow semi-quantitative determination of test material concentrations, when signal intensities are compared between pixels and hyperspectral profiles are compared against positive controls. Hyperspectral imaging: information. Each pixel of an image is associated with a spectral 2 Preliminary tests to optimise the preparation of fairy shrimp and zebrafish and microscopy settings Transmitted light images were recorded from fairy shrimp, wild-type zebrafish embryos and Casper using an Olympus SZX16 microscope equipped with an Olympus XC10 camera (Olympus, UK). Glass coverslips were used to direct a portion of the transmitted light onto a FDS1010 Si photodiode (Thorlabs, UK) whose output was not demodulated. To optimise the technique of preparing fairy shrimp and zebrafish for CRS imaging, a fairy shrimp was placed in a droplet of water directly onto a glass coverslip. Clear transmitted light images (Figure SI-9; left) showed the shrimp moving within the droplet in an oscillating manner, leading to wobbly images at scan times of approx. 20 seconds per frame. Application of faster scan times of approx. 2 seconds per frame led to clear transmitted light images without motion artefacts (Figure SI-9 right). Since scan times of approx. 20 seconds per frame are necessary to obtain a good signal-to-noise ratio in the SRS images (and approx. 14 seconds per frame in the CARS images), animals were fixed in paraformaldehyde (Sigma-Aldrich) and mounted on their left sides between glass coverslips using low melting point agarose gel (Thermo Fisher Scientific, UK) prior to CRS imaging. 3

Setup of the combined SRS CARS microscopy A neodymium vanadate laser source (High-Q Picotrain, Austria) was used to provide a 1064 nm wavelength beam with a 6 ps pulse-width and a repetition rate of 76 MHz. This 1064 nm beam was used as Stokes beam. To generate the pump beam, a 1064 beam was frequency-doubled to 532 nm to pump the near-infrared light source, a Levante Optical Parametric Oscillator (Levante Emerald, APE, Germany). The 1064 nm Stokes beam was amplitude-modulated by an acoustic optical modulator (AOMO 3080-197 Crystal Technology) driven by an 80 MHz driver (AODR 1080AF-A1F0-1.0, Crystal Technology). The collinear Stokes and pump beams were directed into a confocal scan unit (FV300, Olympus, UK) and from there into a modified commercial inverted microscope (IX71, Olympus, UK). Depending on the degree of magnification required, an air-immersion objective lens (UPLSAPO 20x 0.75 NA, Olympus, UK) or a water-immersion objective lens (UPLSAPO 60x 1.2 NA, Olympus, UK) was used to focus the Stokes and pump beams onto the same spot on the sample. When the pump and Stokes beams were focussed onto the same spot on the sample and tuned such that their frequency difference matched a Raman-active molecular vibration in the sample, the amplitude modulation was transferred to the pump beam. For SRS microscopy, the pump beam was then directed onto a wide-area silicon photodiode detector (i.e. the stimulated Raman loss detector, applied reverse bias of 64 V; FDS1010; Thorlabs, UK), which was positioned at the back-aperture of the condensing lens. The output from the silicon photodiode was demodulated using a sophisticated lock-in amplifier (SRS 844; Stanford Research Systems, UK) that was set to pick out and amplify fluctuations in the pump beam occurring at the modulation frequency. The choice of modulation frequency is important, since the sought for stimulated Raman loss signal is so small that normal intensity fluctuations of the laser beam could drown it out. A high frequency of 1.7 MHz was chosen for modulation, since the laser fluctuations only occur at low frequencies. The lock-in amplifier s time constant (the time over which the input signal is integrated) was set to match the pixel dwell time (or voxel dwell time to reflect the three dimensions of the point of focus). Finally, the magnitude of the stimulated Raman loss signal output from the lock-in amplifier was fed into a computer for digital analysis. For simultaneous CARS microscopy, an air condenser (0.55 NA) collected and directed the transmitted light towards a band-pass filter (CARS 890/220 nm, Chroma Technology) to block the 1064 nm Stokes beam thereby generating the anti-stokes signal. CARS images were detected in the backwards epi-direction of the beam using a 750-nm long pass dichroic mirror (750dcxr 229; Chroma Technology) and two filters 4

centred at 660 nm (660.0 IF 40D 230; Ealing Inc.) to separate the signal from the fundamental laser. To acquire hyperspectral images, the SRS lasers were tuned to match one specific Raman shift, an image was acquired, and then the lasers were tuned to match a different Raman shift, etc. Thereby, multiple images were acquired which probed across the respective relevant region of the Raman spectrum. The images were normalised to account for any variation in laser intensity, and each pixel s intensity was plotted as a function of Raman shift thereby producing a hyperspectral data set. The location of any pixels which exhibited signals of the test material was noted. After the desired series of frames had been taken, each frame was false-colour-coded following a rainbow lookup table. Once the coloured hyperspectral data stack was complete, the frames were merged into one single red-green-blue image, using the public domain image processing programme ImageJ developed by the USA National Institute of Health (http://imagej.nih.gov/ij/). Thereby, the composite hyperspectral images exhibit different colours depending on the spectral features of each individual pixel. Composite images for CARS were generated using the same software and techniques. Pre-tests to determine the laser power tolerance of the biological samples determined the optimal total laser power incident on the biological samples (i.e. the laser power at the focus) to be <20 mw. These power tolerance experiments involved gradually increasing the laser power and observing the sample for signs indicative of photo-thermal damage (such as blebbing of the sample). Each organism investigated has a different tolerance to laser intensity, due to its unique scattering and absorption properties. Hence, for each test species the power tolerance experiments were repeated to ensure consistency in sample integrity. 3 Semi-quantitative SRS to determine limit of detection The detected SRS signal is linearly proportional to the concentration of the molecular bonds being probed, and it further varies linearly with both the pump and Stokes laser beam powers. To determine the lowest detectable concentration of the test material with the setup of the present study (applying all parameters as selected for SRS imaging of the aquatic organisms), hyperspectral profiles across the CH stretch region from 2850 cm -1 to 3150 cm - 1 were generated from 110 nm-acp successively diluted in standardised dilution water. The detected signal was normalised relative to the water background, and the aromatic CH stretch peak height at 3055 cm -1 was measured in the CH stretch region. 5

The mass of polymer detected in a certain number of voxels in tissue was calculated based on the limit of detection (LoD) as follows: Mass detected = LoD [mg/l] * voxel volume [L] * number of voxels. The mass of a particle was calculated as follows: Mass particle = Pi /6 * density [g/cm 3 ] * diameter 3 [nm 3 ]. (A 100nm particle has a volume of 5.24 x 10-16 cm³. Assuming a polymer specific density of 1.2 g/cm³, the mass of a single particle is 6.3 x 10-16 g.) The number of particles present in a given sample was calculated as follows: Number of particles in the sample = mass detected / mass particle. If the latter quotient undercut 1, this implied that no integer particles, but rather styrenecontaining impurities of the ACP dispersions were detected. If, however, the quotient exceeded 1, one could not exclude that particles of the test material were detected. 4 Quality control values for acute aquatic toxicity tests Dissolved oxygen and ph values of the test material preparations Fully saturated standardised dilution water was assessed as having 100% dissolved oxygen (8.4 ppm), and its ph was 7.5. The readings of the exposed media were undertaken upon exposure of the D. rerio embryos to the test materials. Neither dissolved oxygen nor the ph value were significantly altered at either 1000 or 2500 mg/l (Table SI-2A and SI-2B). 5 Abbreviations to Supplementary Information CARS: Coherent anti-stokes Raman Scattering; CRS: Coherent Raman scattering; LoD: Limit of detection; SRS: Stimulated Raman Scattering. 6 References to Supplementary information 1. J Moger, BD Johnston, CR Tyler, Optics Express, 2008, 16, 3408-3419. 2. T Galloway, C Lewis, I Dolciotti, BD Johnston, J Moger, F Regoli, Env Pollution, 2010, 158, 1748-1755. 3. A Alfonso-García, R Mittal, ES Lee, EO Potma, J Biomed Opt, 2014, 19, 71407. 4. D Zhang, P Wang, MN Slipchenko, JX Cheng, Acc Chem Res, 2014, 47, 2282-2290. 6