Room Humidity/Temp Sensor

Similar documents
Duct Humidity/Temp Sensor

Outside Air Humidity & Temperature Sensor

Duct Temperature Sensors

Web-Enabled Thermostat IP-MT-101

Potential Applications

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

HIH-5030/5031 Series Low Voltage Humidity Sensors

PT9420 (Extended Range)

HIH-4602 A & C Series.

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

HIH-4030/31 Series Humidity Sensors

HIH-4602-L Series Humidity Sensors

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

HIH-4000 Series Humidity Sensors

HIH-4010/4020/4021 Series Humidity Sensors

Model 5190-F Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information


User s Guide. Shop online at. Made in China. Two-wire Display and Control Unit

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Warranty Registration

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

SEC Signature Process Gas Analyzer

HM1520LF Relative Humidity Module

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

M7100 Pressure Transducer

SKORPION Process Air Heater

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

TL-105 COLUMN HEATER

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

LVCN-302 Set-Up Manual for Sump Model

Ultrasonic Reflective Sensor

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

NT DUAL CHANNEL DISPLAY. User Guide

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

HM1500LF Relative Humidity Module

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Remote Sensor Module: EB-RSM-01

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

NTC THERMISTOR SENSOR PERFORMANCE

Incutrol/2 Regulator

FSS-SMT Series. Low Profile Force Sensor

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Installation, Operation, and Maintenance Manual

Force Sensors Line Guide

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Sensors in Ventilators

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

PM-200 Power Module Operating Instructions

Toroidal Conductivity Transmitters Series APT4000 Specifications

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

OPERATION MANUAL MODEL & ACCELEROMETER

MEAS CAL ALARM WASH CONF APT4000 TC

SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC Siargo Ltd. ISO 9001 ISO OHSAS 18001

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Selecting the right humidity sensor for your application

OPERATING INSTRUCTIONS

User s Guide. FLSW Series ROTAMETER WITH ALARM. Shop online at omega.com. For latest product manuals:

Model OEM-2 INSTRUCTIONS FOR USE

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Blade Series Heat Exchanger Operation and Installation

Linear Current Sensors

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Duct Mount. Installation Instructions

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

M3050 Detector Operator s Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

SEC Millenium Carbon Dioxide Gas Detector

Transcription:

Room Humidity/Temp Sensor Model HU-225-EU (Not Available in North America) RoHS Ultra fast response cross-linked bulk polymer...capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from condensation, fog, salt air, pollutants and other contaminants Wide 12-40 VDC/12-35 VAC unregulated supply voltage (humidity only) Two temperature compensated humidity output versions, 4-20 ma 2-wire or field selectable 0-5 VDC/0-10 VDC NIST traceable ±2% RH or ±3% RH calibration accuracy and ±0.2 C thermistor interchangeability or ±0.1% RTD accuracy The HU-225-EU is an extremely fast, stable and accurate humidity/temperature transducer designed for harsh environments. The polymer capacitance sensor is protected with an eptfe (expanded Teflon) filter media. The Teflon protected cross-linked capacitive humidity sensor is not affected by prolonged exposure to condensing humidity, harsh environments, contaminants, fog or other extreme environmental conditions. Each unit is individually calibrated in an environmental test chamber to meet or exceed NIST traceable ±2% or ±3% accuracies. The HU-225-EU is temperature compensated for -35 C to 55 C operation with negligible error. The HU- 225-EU Humidity/Temp Transducer has an aesthetically-appealing ABS enclosure, which may be flush-mounted or fits a standard back plate. Field selectable outputs, fully temperature compensated NIST traceable accuracy, non-interacting zero and span adjustments, short circuit and reverse polarity protected output, and a liberal five year warranty are some of the features which make the HU-225-EU the industry s highest performance, most reliable humidity/temp sensor. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

The HU-225-EU incorporates a cross-linked bulk polymer capacitive humidity sensor and precision NTC thermistor,platinum or balco RTD temperature sensor. Both temperature and humidity sensors are immune to most contaminants and at the same time provide a stable, repeatable, accurate humidity and temperature measurement with negligible hysteresis. The HU-225-EU utilizes sophisticated integrated circuits to provide a high level, fully conditioned, and temperature compensated humidity output. The temperature sensors are available with more than 16 different industry standard resistance to temperature curves offering compatibility to most if not all control systems. All thermistor sensors offer ±0.2 C interchangeability /accuracy. All thermistors strictly conform to industry standard R/T curves. The platinum RTD s are available with 100 ohm or 1,000 ohm DIN 43760 standards with ±0.12% accuracy at 0 C. All temperature sensors have more than 3.0 mw/ C heat dissipation constant. On VDC output units (humidity only), two additional field selectable options are available; dual outputs 0-5 or 0-10 VDC, and dual unregulated supply voltages 12-35 VAC or 12-40 VDC. By merely moving a dip switch, one can select the desired output for the specific application. As far as supply voltage is concerned, the unit automatically configures for AC or DC, and no field selection is necessary. Another feature is that the output is fully protected from short circuit to ground or if the supply voltage is applied by mistake to the output. Past experience demonstrates that field related wiring problems do occur. Instead of denying this fact, this protection circuit is designed in to ensure trouble-free start-up. The VDC output unit is also designed to handle low impedance circuits. In fact, the unit can drive up to 1K ohm minimum. In this way, multiple controllers, indicators, or other devices can be paralleled to the output without performance degradation. The ma output units (humidity only) function over a wide unregulated supply voltage range: 12-40 VDC without any affect on calibration or performance. The unit has reverse polarity protection built in. As a result, it is next to impossible to damage the unit by wiring incorrectly. By using sophisticated low dropout voltage regulators and CMOS integrated circuits, the ma output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 250 ohms. At 40 VDC, the unit is capable of handling up to a 1500 ohm load. In this way, the output loop can be tied in series to multiple controllers, indicators, and other devices without degrading the performance. The humidity sensor is protected by an eptfe (expanded Teflon) filter media that incorporates a proprietary process of expanding or stretching an ultra thin Teflon sheet during the manufacturing process to create less than 1.0 micron (0.000039 inch) pores or holes. The hydrophobic and oleophobic characteristics of Teflon force moisture, condensation and other contaminants to form a bubble larger than the pore size, and the surface tension of the Teflon stops the water or other contaminants from passing through the filter media, thereby protecting the sensing element. However, air with absorbed moisture can easily penetrate the filter media. NIST traceable humidity standards are utilized to calibrate and certify the HU-225-EU. Calibration data on each unit is archived digitally for SPC and QC purposes. All automated calibration systems are networked, and data is available online to numerous individuals at the same time. In this way, extremely high standards of quality and calibration integrity are maintained. The HU-225-EU wall mount enclosure may be flush mounted on any flat surface or fits a standard back plate. Louvers are provided on the top and bottom of the enclosure to ensure ample air flow for fast response. The enclosure also has additional features for ease of installation, including unpluggable terminal block, easily-accessible zero and span trimmers, and conveniently-located dip switches for field selection. 2

HUMIDITY TRANSDUCER SPECIFICATIONS: THERMISTOR SENSOR SPECIFICATIONS: Accuracy*: ± 2% / ±3% RH Interchangeability: ± 0.2 C Range: 0-100% RH Heat Dissipation: 3.0 mw/ C Hysteresis: ± 1% Supply Voltage: 12-40 VDC 12-35 VAC (VDC output units only) R/T Characteristics: Refer to TI.700-11 (See Temperature Sensor section) Operating Temp Range: -35 C to 55 C Compensated Temp Range: -35 C to 55 C Load Impedance: 1.5K ohms max. at 40 VDC (ma output units) 1K ohms min. (VDC output units) * Includes non-linearity and non-repeatability GENERAL SPECIFICATIONS: Environmental: 10-90%RH Non-Condensing Enclosure: White ABS Plastic Termination: Unpluggable screw terminal block Wire Size: 12 Ga maximum PLATINUM RTD SENSOR SPECIFICATIONS: Accuracy: 0.12% at 0 C Resistance: 100 or 1,000 ohm at 0 C Standard: DIN 43760 Heat Dissipation: 3.0 mw/ C R/T Characteristics: Refer to TI.700-11 (See Temperature Sensor section) Operating Temp Range: -35 C to 55 C ORDERING INFORMATION: HU-225-EU- Weight: 0.5lbs (.25kg) CONFORMANCE & TESTING RoHS Compliant EMC Testing: BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 Accuracy Output Temperature Sensor ±2% ±3% ma (4-20 ma 2-wire) VDC (0-5 VDC/0-10 VDC field selectable) Example: (Humidity Only) HU-225-EU-3-VDC: Humidity Transducer, ±3%RH accuracy with 0-5VDC/0-10 VDC output. (Humidity/Temp Combined) HU-225-EU-2-mA-3: Humidity/Temperature Transducer, ±2%RH accuracy with 4-20 ma output and 1,000-ohm Platinum RTD. For Resistance vs. Temperature Tables, please refer to TI.700-11. 1 100 ohm Platinum RTD 2 1,000 ohm Nickel RTD (5000 PPM) 3 1,000 ohm Platinum RTD 4 1,000 ohm Nickel RTD (6000 PPM) 5 1,000 ohm Balco RTD 7 10,000 ohm NTC thermistor (Type III) 8 10,000 ohm NTC thermistor (Carel) 10 3,000 ohm NTC thermistor 12 10,000 ohm NTC thermistor (Type II) 13 5,000 ohm NTC thermistor 14 1,035 ohm Silicon PTC 15 100,000 ohm NTC thermistor 16 10,000 ohm NTC thermistor (Eliwell) 17 20,000 ohm NTC thermistor 18 2,252 ohm NTC thermistor 21 1,800 ohm NTC thermistor CAUTION: Do not use in explosive/hazardous environment or with flammable/combustible media. 3

2.35" (60.00) 1.67" (42.50) 3.35" (85.00) 1.67" (42.50) 3.35" (85.00) 1.024" (26.00) (mm) 4

MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876