Twin Screw Compounding Extruder

Similar documents
Dryer Controller M720

Oven Control System Operation - Ver 2.8

Rigid Sheet Extrusion Line Rigid Sheet Extrusion Line Feature :

User Manual. Dryer Controller M720

Solving Venting Problems on Twin-Screw Compounding Extruders

Extrusion Profile Resin or Color Change: Performance Tips

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

LA type soldering iron controller

INSTRUCTIONS FOR THD-U SERIES HOT AIR MATERIAL DRYERS

Installer Manual KNX Touchscreen Thermostat

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Bench-Top Vacuum Oven with 28 segments programmable controller

Platinum Touch/Rotem One Touch

Extrusion Blow Molding Resin or Color Change: Performance Tips

Laboratory Twin-Screw Kneader Modular design easy to use versatile in application

Don't just purge Ultra Purge! (TM) Technical Data Sheet. Ultra Purge Ready-to-use purging compound with Ultra-X technology

Filabot EX6 Extruder. Operation Manual. CAUTION! Read Carefully. Filabot Vermont, USA, Earth

SmarTemp Control fx 2.0

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

RANDCASTLE S Taskmaster

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

RD-500V RD-500SV ESD SMT REWORK SYSTEM

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

Injection Molding Cold Runner/Conventional Resin or Color Change: Performance Tips

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

Injection Molding Hot Runner Systems Resin or Color Change Mold Closed: Performance Tips

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Digital Marine Exhaust Temperature Alarm

Intelligent cascading kit

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Ozonated Water System

VENCO - STANDARD PUGMILL ( NON DE-AIR )

Control Application. Supplement - ACVMax

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Halton SAFE / 7.14 user guide and installation instructions

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

TV2 Room Pressure Monitor Quick Start Guide

TC515 and TC600 Installation Manual. a Winters company

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Operational Overview and Controls Guide

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

F4 Process Controller Installation and Operation Guide

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

prestige Control Application Supplement - ACVMax

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Section N. Application Information. Thermal Manufacturing Solutions. Extrusion N-1. Injection Moulding N-2 N-3. Other N-4

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

Fluid Cooler Fan and Pump control panel

T6580 FAN COIL CONTROLLER

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

Electronic Pellet Burner Controller NPBC-V3-1

PONY 2/4 User Guide 2017

4000 1/4 DIN /16 DIN /8 DIN

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

FCR 05, FCR 07. Power factor correction controller. User and service manual

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

TIREE FAN COIL CONTROLLER - T6580

GENERAL SAFETY NOTES Know your equipment Carefully read the instruction manual. Learn the use and limitations of the equipment.

RES-210 (-211, -220, -221) / RES-420

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

RETROFIT CONTROLLER. Retrofit Energy Controller Any Make PIU/ PMS/ IPMS

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

2-wire Passive Intelligent Loop (LED) Display Meter

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

ECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)

Operation Manual (Version 1.5.1)

RD-500V RD-500SV ESD SMT REWORK SYSTEM

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Safety & Installation Instructions

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

FCD-wire Contents. List of Figures

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Far-infrared method Pre-Heater

Added password for IP setup page : Password must be in IP format!

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Instruction Manual (Supplementary) Open Type Inverter

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

HOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

Instructions for the fan motor control system, SILVER C

Transcription:

Twin Screw Compounding Extruder User's Manual BA-11, BA-19 1. Introduction 2. Safety Precaution 3. Specification 4. Settings Bautek http://www.bautek.co.kr

1. Introduction 1. Bautek Twin Compounding Extruder BA-11, BA-19 is the machinery which produces new material by compounding different types of base resin. 2. Bautek Twin Compounding Extruder is suitable for test & experiment high molecular materials such as Nano, PE, PP, PC and even metalized powder. 3. Please be careful to use electricity. This machine needs 200V 3PH electricity. 4. Please kindly notice that this machinery casues high heat which is dangerous, study operation manual before operation to prevent safety accident.

2. Safety Precaution This manual contains the safety method to use this machinery, please study carefully. 1. Use right electricity. 2. Machinery should be away at least 20cm away from the wall. 3. Be careful about the heat during the operation. 4. Fix the machine not to shake before operation. 5. Be careful not to input contamination material into the Barrel. 6. Don t open the Screw Motor Cover unnecessarily. 7. Don t open the Front Cover unnecessarily. 8. If problem happens, please contact us. 220V 3PH Connector <Switch Box> Power SW, Motor SW, Heater SW Feeder Motor Power Cable Emergency Switch

3. Specification Technical Data Extruder <Modular Design> BA-19 BA-11 Barrel Diameter(mm) 19mm 11mm Temperature Control Electrically Heated / Optionally Water Cooled Motor Power(KW) 2Kw(3HP), 2000rpm 400W(1/2HP), 3000rpm Screw Speed(rpm) 0-600 Mounting Barrel Length : Diameter Bench Top L/D=40, Co-Rotating Intermeshing Barrel Heating Power(KW) 6Kw Dimension Length(mm) 1520 860 Width(mm) 500 400 Height(mm) 1700 1400 Weight(kg) 270 Voltage/Power 220V,1/3HP,60Hz, 6.5KVA 3KVA Extrusion Pressure(Max) 100Bar(1500psi) Maximum Operating Temperature 400 Typical Output(kg/hr) 5-25

Electricity Line Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 <19mm> <11mm> 3PH AC 200 ~ 230V, Single PH 230V R S T 19mm 1 3 6 9 2 4 7 10 5 8 11 11mm 1 3 6 12 2 4 7 13 Specification 19mm Screw Motor Feeder Motor Servo Motor Mitsubishi HC-SFS 202 Simens 1LA7063-4AB11 N. Generate(KW) 2.0 0.21, 4P 3PH N. Torque(N.m) 9.55 Max. Torque(N.m) 28.5 1.45 N. Electric Current(A) 11 0.58 Max. Electric Current(A) 33 Specification 11mm Screw Motor Servo Motor Mitsubish HC-KFS 43 Feeder Motor Sumitomo RNYM 009-17-150 N. Generate(KW) 400 90, 4P, 3 상 N. Torque(N.m) 1.3 53.9 Max. Torque(N.m) 3.8 N. Electric Current(A) 2.3 0.57 Max. Electric Current(A) 6.9

4. Settings Operation Procedure 1. Electric Plug In. 2. Electric Power On. 3. Heater Switch On. 4. Motor Switch On 5. Setting the condition in the touch panel.

Settings touch panel 1. Operation Setup Main Setting window 1.1 Main Menu 1) Temperature / Barrel temperature setting 2) Normal / Screw Motor, Feeder Motor s Speed and Torque setting 3) Manual / Barrel Heater switch checking 1.2 System Operation Status 1) Display Barrel Pressure 2) In case of <RESET>, please check the machinery 1.3 Screw Motor Velocity, Torque 1) Display Velocity, Torque in Screw Motor 2) Setting Potentiometer 3) Setting Motor

1.4 Feeder Velocity 1) Display Velocity in Feeder Motor 2) After Screw Motor is <ON>, setting Feeder Motor 3) Feeder Velocity, setting in <Normal> condition 1.5 Zone Temperature Display Barrel s temperature To set the temperature, use <Temperature> at main menu SV : Setting Value PV : Pointing Value 1.6 Valve Operating Setting Valve Operating 1.7 Stuff Temperature Display the temperature inside of Barrel 1.8 Alarm Message Bar Display the machinery status. If this message displayed as above, refer to <5. Alarm Message> to solve problem.

2. Temperature Settings Display the Barrel s Setting Temperature. (Main Menu) To set the Barrel s temperature, click <TEMPERATURE> in main menu. Password will be displayed. Input Password (1234), and click. ** To change Password, use Password in <NORMAL> menu. <TEMPERATURE SETUP> window will open. 2.1Temperature Setup Windows Setting the temperature in each zone of Barrel. <TEMPERATURE SETUP> window 2.2 Temperature Setup 2.2.1 SV(Setting Value) setting Click SV value, setting the temperature from Header to Zone #1 - Zone #7. Click the SV value in each zone After click, the value will be change to 0 (default value). After default, input the number and <ENT>. 2.2.2 PV(Pointing Value) displays the present temperature in each zone of Barrel.

** 주의 ** ** To protect machinery ** After temperature setting, machine will start after reaching 80% of setting temperature. No need to setting 2.2.3 <COOL> This is to control temperature by using <COOL> value. If <PV> value over <SV> value, <Cooling Valve> will automatically operates to the <COOL> value not to over <SV> value. 2.2.4 COOLING VALVE <COOLING VALVE> is an option. Heater inside of Barrel can t keep the temperature sometimes. <Cooling Valve> controls the temperature to <SV> value. If <PV> value over <COOL> value, automatically changes to <COOL> value. <COOLING VALVE> ON. This function works when <COOL> value is under the <PV> value. After <PV> value reaches <COOL> value, automatically <OFF> <COOLING VALVE> OFF 2.2.5 AUTO TUNING SETTING By setting this function, we can reach faster to SV value. Click <AT> button for 5~6 seconds. Color will change to Red from Blue. <AT> Function ON P; Proportional Band, I; Integral Time, D; Derivative Time 2.2.6 Finish Setting Close windows.

2. Normal Setup Setting FEEDER, SCREW MOTOR Speed & Torque s SV, MAX value. SCREW TORQUE 1ST Warning, 2nd Stop, Check Delay, Barrel Pressure Alarm, Password etc. 2.1 Feeder Motor Velocity Settings Setting Feede s RPM SV : Setting Value max : Maximum Velocity of Feeder Motor 2.1.1 Feeder Motor Speed Click <SV> Value, then change <0> Input the No. and <ENT> Setting Motor RPM Click <max> value, then change <0> Input the No. and <ENT> ** Feeder Motor runs in Screw Motor Power <ON> ** max : Don t change the basic setting.

2.2 Screw Motor Settings Setting the Screw Motor Speed & Torque 2.2.1 Screw Motor Velocity Setting <SV> setting : Setting Motor speed Click <SV> value, then change 0 Input the No, and <ENT> <max> setting : Setting Motor highest speed Click <max> value, then change 0. Input the No. and <ENT> ** max : Don t change basic setting value. 2.2.2 Screw Motor Torque Settings <1st Warning> Setting Warning Message value when overload, and Torque value is over. If over this value, Running message will be changed to <1 st Warning> in main menu. Click <1st Warning> No. then change <0> Input the No. & <ENT> <2nd STOP> After 1 st Warning, if reach this value, machinery will stop operation. If over this value, Running message will be changed to <2 nd STOP> in main menu. Motor will get break & stopped. Click <2nd STOP> No., then change <0> Input No. then <ENT> <Check Delay> : If <Mode> is <Use>, Motor will be stopped cause of setting value.

Click <2nd STOP> No., then change <0> ** Notice ** Input No. and <ENT>. (UNIT : sec) You can input from (0,1). If input (0,1), it means (1)sec Click <USE/UNUSE> mode. In this status, Torque Alarm will be stopped Choose <Use>, then setting. 2.2.3 Pressure Alarm Barrel Pressure warning Cick <Pressure Alarm>, then changes <0> 2.2.4 Password Input the No. then <ENT> You can change the Password. Please don t forget the password. Click <Pressure Alarm>, then change <0> Input No. then <ENT>

3.Manual Setup 3.1 Check the Barrel Heater Power Switch 3.2 Check <Cooling Solenoid> Power Switch After ON, it will change to OFF after 5 seconds If you click in <ON>, automatically it changes to <OFF> after 5 seconds ** If not <OFF> after 5 seconds, it means <Cooling Valve> is working.

4. Screw Motor Operation 4.1 To control Screw Motor Velocity with Potentiometer Volume, You can use <Volume> button in Screw Window in main screen to control Motor Velocity by out Potentionmeter. Potentiometer Volume This function is used to control Screw Motor by using outside <Potentiometer Volume>, not by setting value in Touch Panel 1) After setting Screw Velocity in Normal Setup Menu, setting in Screw Window in main screen as below. Main Screen Screw/ Feeder Window 2) Screw Motor <ON> 3) To control Screw Motor Velocity by using <Potentiometer Volume>, the <Volume> button has to be on. <Potentiometer is in top-right side of the Touch Panel> <OFF> : By setting Nomal Setup value, Screw Motor works. Blue Color Button. <ON> : With Potentiomete, we can control speed. Red Color Button. 4.2 Operate with Normal Setup Setting Value By click <Volume> button in Screw Window to Blue button, Screw Motor operates in Normal Setup Condition. Blue Button Click

5. Alarm Message If <RESET> messages appears in Extruder, <Alarm> message will appear at the bottom line. <RESET> Message <Screw Motor Alarm> Message <Feeder Motor Alarm> Message <Pressure Alarm> Message <Screw Torque Alarm> Message <Emergency Alarm> Message <No Error> Message 5.1 Screw Motor Alarm If Alarm message appears, please click <RESET> button. Then <ERROR> message will disappear and start operation. ** In case <ERROR> message is not disappeared after <RESET>, please turn off Power SW, Heater SW, Motor SW and re-start. <No Error> message will appear in main screen.

5.2 Feeder Motor Alarm If this Alarm message appears, it means overload in Feeder Motor <RESET> will be appeared in main screen. 1) Motor will be stopped by break because of Feeder Overload. 2) After remove the cause, click <RESET> and <No Error> appears, 3) Click Feeder.<ON/OFF> in main screen and re-operate. ** Attention In Screw Motor <ON>, Operate Feeder Motor. In Screw Motor <OFF>, Feeder Motor doesn t work. After changing <Screw Motor Velocity> to [0], re-start. If don t change the value to <0>, it may cause damage to the screw. 5.3 Pressure Alarm This message means the pressure is over than setting value. 1) If the Bareel Pressure over than setting value in <Pressure Alarm> in Normal Setup Menu, all operations will be stopped to protect the machinery. 2) In Main screen <RESET>, warning message <Pressure Alarm>, 3) after removing the reason of over pressure, and click <RESET> and <No Error> message comes, 4) Re-operate ** Attention ** After input <Screw Motor Velocity> to [0], then re-operate. Otherwise, it may cause damange to screw. 5.4 Screw Torque Alarm If over Torque happens inside of Barrel Screw, all operation will be stopped. 1) If Screw Torque Value shows over than <2 nd STOP> which was set in <Screw Torque> in <Normal Setup> menu, 2) Main Screen <RESET>, warning message <Screw Torque Alarm> appears, and all operation will be stopped. 3) After removing the reason of overload, click <RESET> and <No Error> message appears, 4) Re-operate ** Attention ** After changing <Screw Motor Velocity> to [0], re-operate. Otherwise, It may damage the screw.

5.5 Emergency Alarm <Emergency Alarm> Message If <Emergency Alarm> appears as in the picture above, click the emergency switch and turn off all power. After removing the cause, turn right the emergency switch, everything will be back to normal. Click <RESET> button in main screen, and <No Error> message appears, Re-operate. Emergency Switch 5.6 No Error 1) If all the condition is normal, <Running> message will appear in screen. 2) <No Error> message will be showed.