Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Similar documents
Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

CARLO GAVAZZI Automation Components. CA30CAN/CAF - Capacitive Sensors

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

M5200 Industrial Pressure Transducer

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

The New Generation of Intelligent

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Ultrasonic Proximity Sensor

U5300 Industrial Pressure Transducer

M7100 Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Technical Data. General specifications. Rated operating distance s n 5 mm

U5700 Submersible Liquid Level Pressure Transducer

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

REA 105 Arc Protection Module. Operator s Manual

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

INSTRUCTION MANUAL (ATEX / IECEx)

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Technical Data. Dimensions

Ordering Key. Dielectric strength

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

D5100 Industrial Differential Pressure Transducer

Soft Starter Centrifugal Pump Soft Starter Series

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

CAPACITIVE SENSORS. Reliable detection of objects and fi ll levels.

M5800 Pressure Transducer with Rotatable Display

Quick Start Manual July pointek CLS100

Reliable Detection of Transparent Objects

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Inductive slot sensor

D5100 Industrial Differential Pressure Transducer

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Technical Data. Dimensions

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Retro-reflective Sensing range: 0mm to 2000mm

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Technical Data. Dimensions

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

5.0. Photoelectric Sensors. Technical Reference. Introduction

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

4 & 8-POINT ANNUNCIATORS Instruction Manual

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

for relative humidity and temperature

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

LC2200 Level Controller Installation and Maintenance Instructions

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Technical Data. Dimensions

Vacuum suction nozzle OVEM-...-1P/1N

Class 1 laser beam sensor safe for your eyes

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Class 1 laser beam sensor safe for your eyes

SOCH AUTOMATION AND POWER SOLUTION

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

E3M-V. Mark Sensor. Applications

M5800 Pressure Transducer with Rotatable Display

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Ultrasonic Proximity Sensor

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Audible warning devices for external alarm

Temperature measurement with current output and PNP/NPN transistor switching output output 2 reprogrammable as switching output TS-400-LI2UPN8X-H1141

Class 1 laser beam sensor safe for your eyes

Fisher LCP100 Local Control Panel

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

PHOTOELECTRIC AMPLIFIER SERIES

CYLINDRICAL Inductive Proximity Sensors

Operation and use. Functions and characteristics

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

for relative humidity and temperature

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

Air. Pressure. Motion. nnnnnnnn

QFM21... Duct sensors. Symaro. for relative humidity and temperature

UNIVERSAL COMPACT SENSORS

InductIve SenSorS 2018

Rules for Intruder Alarm Systems

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

SensaGuard TM Integrated Latch Installation Instructions

S15 SERIES. Ceramics. Beverage & Bottling

Transcription:

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF... 4 TH Generation TRIPLESHIELD TM Adjustable sensing distance: 2-10 mm Flush or 3- mm Non-flush Protection: short-circuit, transients and reverse polarity Dust and humidity compensation Dust or Temperature alarm output Rated operational voltage: 10-40 VDC Output: DC, NPN or PNP Standard Output: NO and NC indications for Power-supply, Target and Stability IP67, IP68, IP69K, Nema 1, 2, 4, 4X, 5, 6, 6P, 12 Cable and M12 connector versions available Product Description The CA18CA.. capacitive proximity switches feature an improved 4 TH Generation TRIPLESHIELD TM technology. Furthermore, these sensors feature increased immunity to electromagnetic interference (EMI), especially to frequency drives. Not only does 4 TH Generation TRIPLESHIELD TM feature an increased EMI, but it also increases the immunity to humidity and dust. The implementation of stability indication eases the setup procedure as both Stable ON and Stable OFF positions are indicated by the green and yellow s. The sensing distance is increased by 25 % allowing room for additional stable detection. The Dust Alarm function gives an early warning that the sensing surroundings have to be cleaned. The Temperature alarm function raises an alarm if the sensing surface goes beyond 60 degree Celcius. The sensor housing is featuring IP69K as well as approval by ECOLAB for cleaningand disinfection agents. Ordering Key Capacitive proximity switch Housing diameter (mm) Housing material Housing length Detection principle Rated operating dist. (mm) Output type Output configuration Connection type CA18CAN12NAM1 Type Selection Housing Sensor Output Output Connection Rated operating Ordering no. Ordering no. Ordering no. diameter type type function distance (S n) Standard Dust alarm Temperature alarm M 18 Flush NPN NO+NC Cable 0-8 mm CA18CAF08NA M 18 Flush NPN NO+NC M12 Plug 0-8 mm CA18CAF08NAM1 M 18 Flush PNP NO+NC Cable 0-8 mm CA18CAF08PA M 18 Flush PNP NO+NC M12 Plug 0-8 mm CA18CAF08PAM1 M 18 Flush PNP NO Cable 0-8 mm CA18CAF08PODU CA18CAF08POTA M 18 Flush PNP NC Cable 0-8 mm CA18CAF08PCDU CA18CAF08PCTA M 18 Non-Flush NPN NO+NC Cable 0-12 mm CA18CAN12NA M 18 Non-Flush NPN NO+NC M12 Plug 0-12 mm CA18CAN12NAM1 M 18 Non-Flush PNP NO+NC Cable 0-12 mm CA18CAN12PA M 18 Non-Flush PNP NO+NC M12 Plug 0-12 mm CA18CAN12PAM1 M 18 Non-Flush PNP NO Cable 0-12 mm CA18CAN12PODU CA18CAN12POTA M 18 Non-Flush PNP NC Cable 0-12 mm CA18CAN12PCDU CA18CAN12PCTA Specifications EN 60947-5-2 Rated operating distance (S n) Non-flush mounted sensor Flush mounted sensor 0-12 mm (factory setting 12 mm), (ref. target 36x36 mm ST37, 1 mm thick, grounded) 0-8 mm (factory setting 8 mm - non-flush mounted) (ref. target 24x24 mm ST37, 1 mm thick, grounded) Sensitivity control Electrical adjustment Mechanical adjustment Adjustable distance Flush types Non-flush types Effective operating dist. (S r) Adjustable by potentiometer 11 turns 16 turns 2 to 10 mm 3 to mm 0.9 x S n S r 1.1 x S n Specifications are subject to change without notice (22.11.2017) 1

Specifications (cont.) EN 60947-5-2 Usable operating dist. (S u)* 0.85 x S r S u 1. x S r Repeat accuracy (R) 5% Hysteresis (H) 3-20% Rated operational volt. (U B) 10 to 40 VDC (ripple incl.) Ripple 10% Output function NPN or PNP Output switching function N.O. and N.C. Rated operational current (I e) (continuous) Capacitive load 100 nf No-load supply current (I o) 12 ma Voltage drop (U d) 2.0 VDC @ DC Minimum operational current (I m) 0.5 ma OFF state current (I r) 100 μa Protection Short-circuit, reverse polarity, transients Frequency of operating cycles (f) 50 Hz Response time OFF-ON (t on) 10 ms Response time ON-OFF (t off) 10 ms Power ON delay (t v) 200 ms Indication Target detected, yellow Power and detection stability, green Environment Installation category III (IEC 60664, 60664A; 60947-1) Degree of pollution 3 (IEC 60664, 60664A; 60947-1) Degree of protection IP 67, IP 68/60 min., IP69K** (IEC 60529; 60943-1) NEMA type 1, 2, 4, 4X, 5, 6, 6P, 12 Operating temperature -30 to +85 C ( -22 to +185 F) Max. temperature on sensing face 120 C (248 F) Storage temperature -40 to +85 C (-40 to +185 F) Rated insulation voltage 1 kvac (rms) IEC protection class III Tightening torque 2.6 Nm Connection Cable Plug (M1) PVC, Ø5.2 x 2 m, 4 x 0.34 mm 2 Oil proof, grey M12 x 1-4 pin Temperature alarm output 60ºC ± 5ºC Response time examples T A = 25 C 14 sec @ T EXC = 800 C 3 sec @ T EXC = 80 C TRIPLESHIELD TM Exceeding the norms for capacitive sensors Electrostatic discharge (EN61000-4-2) Contact discharge > 40 kv Air discharge > 40 kv Electrical fast transients/burst (EN 61000-4-4) ±4kV Surge (EN 61000-4-5) Power-supply > 2kV (with 500 Ω) Sensor output > 2kV (with 500 Ω) Wire conducted disturbances (EN 61000-4-6) > 20 Vrms Power-frequency magnetic fields (EN 61000-4-8) Continous > 60 A/m, 75.9 µ tesla Short-time > 600 A/m, 759 µ tesla Radiated RF electromagnetic fields (EN 61000-4-3) > 20 V/m Shock (IEC 60068-2-27) 30 G / 11ms, 3 pos, 3 neg per axis Rough handling shocks (IEC 60068-2-31) Vibration (IEC 60068-2-6) Housing material Body Cable gland Fingernuts Trimmershaft Weight Cable version Plug version Approvals CE-marking MTTF d 2 times from 1m 100 times from 0,5m 10 to 0 Hz, 1 mm / G PBT, grey, 30% glass reinforced PA12, black PA12, black Nylon 0 g 75 g culus (UL508), ECOLAB Yes 825 years @ 40 C (+104 F) * For Flush type sensor flush mounted in conductive material, the usable operating distance (Su) is 0.80 x S r S u 1.2 x S r for temperatures exceeding 0-60 C ( 32-140 F). ** The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications. The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning. The sensor is exposed to high pressure water from a spray nozzle that is fed with 80 C water at 8 000 10 000 KPa (80 100bar) and a flow rate of 14 6L/min. The nozzle is held 100 0 mm from the sensor at angles of 0, 30, 60 and 90 for 30s each. The test device sits on a turntable that rotates with a speed of 5 times per minute. The sensor must not suffer any damaging effects from the high pressure water in appearance and function. 90 60 30 0 2 Specifications are subject to change without notice (22.11.2017)

Adjustment Guide The environments in which capacitive sensors are installed can often be unstable as regards temperature, humidity, object distance and industrial (noise) interference. That is why Carlo Gavazzi offers as standard features in all TRIPLESHIELD TM capacitive sensors a user-friendly sensitivity adjustment instead of a fixed sensing range. Likewise, these sensors provide an extended sensing range to accommodate mechanically demanding areas and temperature stability to ensure high immunity to electromagnetic interference (EMI) and a minimum need for adjusting sensitivity, if the temperature varies. Note: The sensors are factory set (default) to nominal sensing range Sn.S n. Wiring Diagram NPN PNP Dust- or Temperature alarm on NC WH WH (DU/TA) PNP PNP Dust- or Temperature alarm on NO WH WH (DU/TA) Detection Diagram (mm) Sensor Y Flush Non-flush X Target Distance (inch) Distance (inch) -0,31-0,24-0,16-0,08 0 0,08 0,16 0,24 0,31 0,39 0,47 0,55-0,31-0,24-0,16-0,08 0 0,08 0,16 0,24 0,31 0,39 0,47 0,55 25 0,98 25 0,98 20 0,79 0,59 10 0,39 5 0,20 0 0,00-5 -0,20-10 -0,39 - -0,59-20 -0,79-25 -0,98-8 -6-4 -2 0 2 4 6 8 10 12 14 Sensor head (inch) (mm) 20 0,79 0,59 10 0,39 5 0,20 0 0,00-5 -0,20-10 -0,39 - -0,59-20 -0,79-25 -0,98-8 -6-4 -2 0 2 4 6 8 10 12 14 Sensor head (inch) Distance (mm) Distance (mm) Specifications are subject to change without notice (22.11.2017) 3

Detection Stability Indication Target influence Stable ON Output ON Output OFF Stable OFF Time Green ON Yellow ON Output NO Output NC Dust alarm NO >1 sec. >1 sec. >1 sec. >2 sec. Dust alarm NC >1 sec. >1 sec. >1 sec. >2 sec. Dimensions CA18CAF... 86 CA18CAF...M1 85 M18 x 1.0 x 55 M18 x 1.0 x 55 M12 x 1.0 CA18CAN... CA18CAN...M1 86 85 8 M18 x 1.0 x 47 8 M18 x 1.0 x 47 M12 x 1.0 Cable Plug The back of the sensor Sensitivity adjustment Yellow Green 3 2 1 Colour code 1 Brown 2 White 3 Blue 4 Black 4 4 Specifications are subject to change without notice (22.11.2017)

Installation Hints Capacitive sensors have a unique ability to detect almost any material in li quid or solid form. Capa ci tive sensors are able to detect metallic as well as non-metallic ob jects. How ever, their traditional use is for non-metallic materials such as: Plastics Industry Resins, regrinds or moulded products. Chemical Industry Cleansers, fertilizers, liquid soaps, corrosives and petrochemicals. Wood Industry Saw dust, paper products, door and window frames. Ceramics & Glass Industry Raw materials, clay or finish ed products, bottles. Packaging Industry Package inspection for level or contents, dry goods, fruits and vegetables, dairy products. Materials are detected due to their dielectric constant. The bigger the size of an object, the higher the density of material, the better or easier it is to detect the object. The nominal sensing distance for a capacitive sensor is referred to a grounded me tal plate (ST37). For additional information regarding dielectric ratings of materials please re fer to Technical Information. To avoid interference from inductive voltage/ current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables Relief of cable strain Protection of the sensing face Switch mounted on mobile carrier Not correct Correct The cable should not be pulled A proximity switch should not serve as a mechanical stop Any repetitive flexing of the cable should be avoided Delivery Contents Capacitive switch: CA18CAN/CAF... User manual 2 x M18 fingernuts Screwdriver Packaging: Cardboard box Accessories Connector type CONB14NF-... -series. Mounting Brackets AMB18-S.. (straight), AMB18-A.. (angled) Specifications are subject to change without notice (22.11.2017) 5