Predator Controller Hardware Family

Application Data Part Numbers: 33ZCVVTZC-01, 33ZCBC-01, 33ZCVAVTRM, 33ZCFANTRM

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

I/O ZONE 560/583 USERS GUIDE

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

T7984 A,B,C Electronic Modulating Control Thermostats

VCM-X Controller Technical Guide

Accuracy by Design Products for the HVAC Professional

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Power and Energy Management Solutions

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

CP CP

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Semi flush-mount room thermostat

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Cable Actuated Sensor Industrial User Scalable VDC Output

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

Flush-mounted room thermostat

T6984F,G Electronic Floating Control Thermostats

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

HVAC Controls Upgrades: Requirement Details ( )

Temperature Controllers

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Schneider Electric Erie T155 Series

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac

ET10 Series Stand-alone LCD Fan Coil Thermostat

Digital Precise Air Control - DPAC

ETAF Series VDC Fan output LCD Fan Coil Thermostat

VCM-X Modular E-BUS Controller Technical Guide

AHU Air Handling Unit Fundamentals. j.ilangumaran

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Product Data. Features/Benefits. AirManager Control. 33AM Comfort System

SEQUENCE OF OPERATIONS

Reference Guide for Microprocessor Controller

T6984 A,D,E Electronic Floating Control Thermostats

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Control Sequence Number

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Multi-Path RTU-TYPE 2

Wall-mounted room thermostat with LCD

Danfoss gas detection units

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

features Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3

Installation Guide. DXUV Universal Air Control - Single Zone VAV Controller

Mammoth Water Source Heat Pumps

15900 HVAC INSTRUMENTATION AND CONTROLS

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Cable Actuated Sensor Industrial User Scalable 4 20mA

The ultimate fresh air solution.

HVAC Controls Upgrades: Requirement Details ( )

Installation Guide. DXU3 & DXU4 Universal Air Control - Single Zone. Self-Contained Interoperable Controller Model UCP-1

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

CLEANROOM MONITOR CR3A Network - Installation Instructions

Feature Summary. I. System

ELECTRONIC HUMIDISTAT: H270

Danfoss gas detection units

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Reference Guide for Microprocessor Controller

Networkable Fan Coil Controller Specification and Installation Instructions

TER Active Room Temperature Sensor (Controller),

N M AirControl AHU. Control manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Introduction. What is a VVT Zone controller?

Model Smart Digital Humidistat

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Verasys System Operation Overview Technical Bulletin

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

EC3-X33 Stand-alone Superheat Controller Technical Data

Document # R01

Powers Controls Low Temperature Detection Thermostat

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

POWERS CONTROLS Pneumatic Thermostat Covers

McQuay Microtech III BACnet MS/TP Application 4181 Point Map

HLR 1000E Technical Specifications

Transcription:

Predator Controller Hardware Family Figure1: Predator Controller Only. Figure 2: Predator VAV Actuator. The LONMARK certified configurable Predator Controller provides direct digital control of a variety of mechanical equipment ranging from zone level control of VAV/CV, Heat Pump, Unit Ventilator, and Fan Coil Units to air distribution units to mechanical plants to spare point pick up of miscellaneous zone equipment. The Predator Controller is designed to reside on a LONWORKS network, providing seamless interaction with all LONMARK products. The Predator Controller offers cost-effective flexibility that provides various input/output configurations; each designed to meet the individual equipment application requirements. Features Conforms to and is certified to the LONMARK interoperability guidelines, enabling information sharing with other LONMARK products. LONMARK-compliant with space comfort functional profile number 8505 for zone level control and the Discharge Air Controller Functional Profile 8610 for air distribution control. Field-selectable parameters allow entry and updating of setpoint and control parameters via the TALON Interface. Two packaged designs to meet unique market needs, consisting of: o Predator Controller Only two-piece series, consisting of a plenum-rated NEMA 1 Enclosure Cover with Embedded Controller Board and a separate Wiring Base, protects electronic parts from potential damage during installation. o Integral shaft-mount of the one-piece Predator VAV Actuator further reduces installation and setup time. Variety of platform configurations for application flexibility. Advanced PID control minimizes offset and maintains tighter setpoint control. Return to service from power failure without operator intervention. Document No. 588-203 June 2009

Applications The Predator Controllers can be configured to control a variety of equipment Predator Type Control Functionality VAV/CV Single Duct VAV/CV cooling only VAV/CV heating only VAV/CV with hot water reheat VAV/CV with electric reheat (up to three stages) VAV cooling/heating switchover VAV series or parallel fan-powered with hot water reheat VAV series or parallel fan-powered with electric reheat (up to three stages) VAV/CV Dual Duct Cold duct and hot duct Dual cold duct Dual hot duct Low Flow Single For Critical areas and maximum energy efficiency ideal control for 50-800 fpm Duct VAV/CV cooling only VAV/CV heating only VAV/CV with hot water reheat VAV/CV with electric reheat (up to three stages) VAV cooling/heating switchover VAV series or parallel fan-powered with hot water reheat VAV series or parallel fan-powered with electric reheat (up to three stages) Low Flow Dual Duct For Critical areas and maximum energy efficiency ideal control for 50-800 fpm Cold duct and hot duct Dual cold duct Dual hot duct VAV with Variable Speed Fan Control For VAV/CV zones that have an electrically commutated (ECM) fan motor that require automatic adjustment of terminal parallel or series fan speed to match current loading conditions Heat Pump Single-compressor heat pump without reversing valve Single-compressor heat pump, mixed air control without reversing valve Single-compressor heat pump with reversing valve Single-compressor heat pump with reversing valve and mixed air control Multi-stage compressor (1-3) heat pump, mixed air without reversing valve Multi-stage compressor (1-3) heat pump, mixed air control with reversing valve Unit Vent (ASHRAE Cycle II) Cooling and outside air damper Heating and outside air damper Shared cooling/heating coil and outside air damper (2-pipe) Cooling/heating coil and outside air damper (4-pipe) Cooling/heating coil and outside air damper with face/bypass damper (4- pipe) Shared cooling/heating coil, plus electric heat and outside air damper (2- pipe) Shared cooling/heating coil, electric heat and OA damper w/ face/bypass (2- pipe) One- or two-stage DX cooling with heating coil and outside air damper Unit Vent with For Heating/Water Source Cooling (H/C) Unit Ventilators that require humidification Dehumidification control, while meeting Demand Control Ventilation (DCV) standards Fan Coil Unit Fan coil cooling only Fan coil heating only Two-pipe fan coil unit shared cooling and heating Four-pipe fan coil unit cooling and heating Fan coil unit with 1 to 2 stages of DX cooling and electric heat Fan coil unit with 1 to 2 stages of DX cooling and hot water coil Page 2 of 13

Applications, Continued Predator Type Miscellaneous Equipment Four stage DX AHU VAV Air Handling Unit Three Zone Control Control Functionality The Four Loop Controller contains 4 internally cascaded PID loops and programming logic to perform control of a variety of equipment, such as: Hot water converters Simple heating and cooling plants Two VAV rooms IAQ routines Humidity control Three sensor input loops VFD control Fan tracking Heat recovery units Emergency generators Up to four stat to valves Up to four booster coils Miscellaneous input / output points For Single Zone Air Handling Unit with hot water heating, up to 4 stages of DX cooling and Exhaust Fan coordination with OA damper control For VAV Air Handling units with OA, RA and DA dampers Economizer cycle Demand Control Ventilation routines (DCV) Supply air temperature reset Fan speed Fan status Safeties For controlling Room Temperature Sensor to Valve, Multi-Zone AHUs, Multiple VAV Pressure Dependant zones, etc. with the following configurations: Two to three zones with heating OR cooling Two zones of heating AND cooling Two to three zones of heating OR cooling valve with fan Based upon availability of input and output capacity, perimeter heat, lighting, occupancy and outdoor air temperature sensors can be added to these Predator types. Hardware There are two types of Predator hardware: Predator Controller Only for application control of all types listed above Predator VAV Actuator for smaller point count VAV/CV units Predator Controller Only Hardware The unique design of the Predator Controller consists of two components: Enclosure Cover with Embedded Controller Board Wiring Base Predator Controller Only Enclosure Cover with Embedded Controller Board This design reduces threat of damage to the controller board during installation and reduces service time. The wiring connections are made to the wiring base, allowing this component to be installed early in the project cycle. Additionally, if the board needs repair, the controller board can be removed easily, without disrupting the wiring connections. To further enhance the protection of the controller board, it is embedded into the plenum-rated enclosure cover. Installation consists of snapping the enclosure cover onto the wiring base. Page 3 of 13

The Predator Controller Only Enclosure Cover with Embedded Controller Board is available in the following configurations: 6 Inputs, 8 Digital Outputs, 3 Analog Outputs, 1 Room Sensor, (1 DPS for VAV/CV only) The Controller Board communicates to all LONMARK devices via a Neuron -chip. The controllers are shipped with pre-loaded applications, reducing engineering start-up time. The control application is stored in Flash memory. Flash memory allows an application to be changed without removing the existing controller or memory chip. Predator Controller Only Wiring Bases The Full Point wiring base is designed to handle either Full Point 5IN/8DO/3AO controller or Reduced Point 4IN/6DO controller. This base provides the flexibility of interchanging a Reduced Point I/O-style controller with a Full Point I/O-style controller if needs change. Predator VAV Actuator Hardware The Predator VAV Actuator one-piece design combines the proven reliability of the Predator VAV controller functionality with Siemens OpenAir GDE (44 lb-in) direct-coupled, 24 Vac, Non-spring return, rotary electric actuator and Siemens OpenAir GLB (88 lb-in) direct-coupled, 24 Vac, Non-spring return, rotary electric actuator. By incorporating control of VAV applications directly into these compact actuator housings, installation costs can be reduced. Additionally, these Predator solutions continue to meet plenum rated job requirements. Embedded Controller Board The Embedded Controller has on-board termination support for 1 Input, 2 Digital Outputs, 1 Room Sensor, and 1 DPS. The Controller Board communicates to all LONMARK devices via a Neuron -chip. The controllers are shipped with pre-loaded applications, reducing engineering start-up time. Siemens Actuator The direct-coupled 24 Vac Non-spring Return Rotary Electric LON VAV/CV Actuator is designed for three-position (floating) control of building HVAC dampers. It features easy-to-see position indicator, and quiet, low-power operation. Spare Input/Output Points The Predator Controller, depending upon the application, may have up to 3 input and 2 output spare points available. These points can be used for control of devices located in close proximity to the Predator Controller, reducing installation costs. Differential Pressure Sensor for all Zone Level VAV/CV Applications The Differential Pressure Sensor connects to the air terminal box air-velocity sensing elements to provide measurement of the differential pressure. The measured value is converted to actual airflow in CFM (Ips) by the Predator VAV/CV Controller. Page 4 of 13

Controller Specifications Processor Type Neuron 3150 Processor Clock Speed Network Communication Speed Memory Size 10 MHz - Neuron TP/XF-10 (78.8K bps) 49 K Flash Memory 10 K SRAM Voltage Requirements Power Consumption Ambient Operating Environment Agency Listings 24 Vac @ 50/60 Hz 5 VA plus loads +32 F to +122 F (0 C to +50 C) 5 to 95% RH (Non-condensing) UL/CUL 916 PAZX/PAZX7 (Enclosed Energy Management) Regulatory Compliance LONMARK 3.2 FCC Part 15, Class B CISPR 22 Class B CE Mark Australian EMC Framework Predator Dimensions 6.75" H 7" W 2.45" D (171 mm 178 mm 62 mm) Predator Weight 2 lbs. (.9 kg) Predator VAV Actuator Dimensions: 5 9/16" H x 2 15/16 " W 4 3/16" D (142 mm 75 mm 106 mm) Predator VAV Actuator Weight 2.0 lbs. (.9 kg) Actuator Specifications For Predator VAV Actuator Function Torque 44 lb-in (5 Nm) Runtime for 90 opening or closing 90 sec. At 60 Hz (108 sec. At 50 Hz) Nominal angle of rotation 90 Maximum angular rotation 95 Mounting Shaft size 3/8 to 5/8 inch (8 to 16mm) diameter Minimum shaft length 1-1/2 inch (38 mm) Housing Material Durable plastic Gear lubrication Silicone free Miscellaneous Life cycle Designed for over 50,000 full stroke cycles and 1.5 million repositions at rated torque and temperature Page 5 of 13

Wiring Diagrams Full Point Wiring Base DO 3 DO 4 10K Thermistor or DI Network connection Room Sensor Connection via RJ-11 E H C (E) Earth (H) Line (C) Neutral Power Wiring Predator VAV Actuator Wiring Page 6 of 13

3 DO 2 AI 10K Thermistor Voltage input Either of which can be a DI LON port Room Sensor Connection Predator VAV Actuator Wiring Power Wiring: (E) Earth (H) Line (C) Neutral Wiring Recommendations: Input/AO 20 to 22 AWG DO 18 to 22 AWG Power 16 to 18 AWG LONWORKS Network 22 AWG Level 4 Transformer Requirements and Recommended Voltages Type Class 2, 24 Vac, 50/60 Hz Optional Accessories Predator Room Temperature Sensors The Predator Room Temperature Sensors offer a wide range of features and functions. The sensors work with the TALON building-automation system to deliver exceptional occupant comfort in even the most demanding application environments. The product family ranges from temperature-sensing-only variants to sensors that include LCD display, setpoint and override. All sensors incorporate precision temperaturesensing elements that accurately and reliably measure room temperature. Their compact design results in an attractive, inconspicuous installation. A styled ventilation ring optimizes airflow through the cover for fast measurement response. Predator Room Sensor Specifications Dimensions 3-11/32" H 2-1/2" W 1-1/2" D (85 mm 63 mm 38 mm) Temperature Monitoring Range Thermistor Resistance Value Setpoint Range Calibration Adjustments Standard Colors 55 to 95 F (13 to 35 C) 10,000 Ohms @ 77 F (25 C) 55-95 F None Required White Page 7 of 13

Differential Pressure Sensors The self contained-remote-mount Siemens Differential Pressure Sensors (DPS) may be used as the primary input for control and as a cost effective solution to control VAV Dual Duct zones. The 590 Series differential pressure sensors are 24 Vac powered and provides a 0-10 Volt control signal with a 1% full-scale accuracy. The standard control signal enables these devices to be used with almost any control or energy management system. Five (5) different units measure ranges from 0 to 1 water column to 0 to 5 water column. A 1/4 to 1/4 version is offered as well. The case is made from fire retardant, glass-filled polyester. The pressure ports are standard 1/4 barb fittings. Power and signal wires are terminated on a screw terminal strip. In addition, all units have zero and span potentiometers, allowing them to be field calibrated. The housing base is mounted on a metal back plate for easy installation. Versions with conduit housings are also available. Predator Ordering Information Predator Controller Only Predator 10K Full Point Single Duct VAV/CV Controller 5IN 8DO 2AO 1DPS 5 INI (2) 10 K Thermistor / (3) 0-10 Vdc or Dry Contact 2 AO 0-10 Vdc Predator 10K Full Point Dual Duct VAV/CV Controller 5IN 8DO 2AO 1DPS 5 INI (2) 10 K Thermistor / (3) 0-10 Vdc or Dry Contact 2 AO 0-10 Vdc Predator 10K Reduced Point CH/HW FCU Controller 4IN 6DO Product Number 587-135 587-136 587-215 4 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 6 DO 24 Vac, 12VA, Triac Predator 10K Reduced Point DX FCU Controller 4IN 6DO 587-216 4 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 6 DO 24 Vac, 12VA, Triac Predator 10K Full Point CH/HW FCU Controller 6IN 8DO 3AO 587-225 Predator 10K Full Point DX FCU Controller 6IN 8DO 3AO Predator 10K Reduced Point HP Controller Rev. 3, 4IN 6DO 4 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 6 DO 24 Vac, 12VA, Triac 587-226 587-246 Page 8 of 13

Predator Controller Only, Continued Predator 10K Full Point HP Controller Rev. 3, 6N 8DO 3O 5 INI (2) 10 K Thermistor / (3) 0-10 Vdc or Dry Contact Predator 10K Reduced Point UV CH/HW Controller 4IN 6DO 4 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 6 DO 24 Vac, 12VA, Triac Predator 10K Reduced Point UV DX Controller 4IN 6DO 4 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 6 DO 24 Vac, 12VA, Triac Predator 10K Full Point UV CH/HW Controller 6N 8DO 3AO Predator 10K Full Point UV DX Controller 6I 8DO 3AO Predator 10K Full Point UV CH/HW with Face/Bypass Controller 6N 8DO 3AO Predator 10K Three Zone Controller 6IN 8DO 3AO 6 IN (2) 10 K Thermistor / (4) 0-10 Vdc or Dry Contact Predator 10K Four Loop Controller 6IN 8DO 3AO 6 IN (2) 10 K Thermistor / (4) 0-10 Vdc or Dry Contact Predator 10K VAV AHU Controller 6IN 8DO 3AO 6 IN (2) 10 K Thermistor / (4) 0-10 Vdc or Dry Contact Predator 10K UV with Dehumidification Controller 6IN 8DO 3AO 6 IN (2) 10 K Thermistor / (4) 0-10 Vdc or Dry Contact Predator 10K VAV Variable Speed Fan 6IN 8DO 3AO 6 IN (2) 10 K Thermistor / (4) 0-10 Vdc or Dry Contact Product Number 587-256 587-275 587-276 587-285 587-286 587-287 587-289 587-292 587-293 588-510 588-511 Page 9 of 13

Predator Controller Only, Continued Predator 10K Four Stage SZ AHU Controller 6IN 8DO 3AO 6 IN (2) 10 K Thermistor / (4) 0-10 Vdc or Dry Contact Predator 10K Single Duct VAV QVM Controller 6I 8DO 3AO Predator 10K Dual Duct VAV QVM Controller 6I 8DO 3AO Wiring Bases Predator Full Point Wiring Base Termination support up to 5IN, 8DO and 3AO Product Number 588-513 588-526 588-527 Product Number 587-175 Predator VAV Actuator Predator 10K VAV Actuator single pack 1 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 2 DO 24 Vac, 6VA, Triac (non-powered enables hot/neutral field wiring) 1 Siemens GDE131.P Actuator Predator 10K VAV Actuators 10 pack 1 IN (2) 10 K Thermistor / (2) 0-10 Vdc or Dry Contact 2 DO 24 Vac, 6VA, Triac (non-powered enables hot/neutral field wiring) 1 Siemens GDE131.P Actuator Predator 10K GLB VAV Actuator 2301 2 IN (1) 10 K Thermistor / (1) 0-10 Vdc (Either can be Dry Contact but not both at the same time) 3 DO 24 Vac, 12VA, Triac (non-powered enables hot/neutral field wiring) 1 Siemens GLB (88 lb-in) Actuator Predator 10K GDE VAV Actuator 2301 2 IN (1) 10 K Thermistor / (1) 0-10 Vdc (Either can be Dry Contact but not both at the same time) 3 DO 24 Vac, 12VA, Triac (non-powered enables hot/neutral field wiring) 1 Siemens GDE (44 lb-in) Actuator 587-102 587-102P10 587-103 587-104 Page 10 of 13

Predator VAV Actuator Predator 10K GDE VAV Actuator 2301 with CO2 2 IN (1) 10 K Thermistor / (1) 0-10 Vdc (Either can be Dry Contact but not both at the same time) 3 DO 24 Vac, 12VA, Triac (non-powered enables hot/neutral field wiring) 1 Siemens GDE (44 lb-in) Actuator Predator 10K GDE VAV Actuator 2301 with SAT 2 IN (1) 10 K Thermistor / (1) 0-10 Vdc (Either can be Dry Contact but not both at the same time) 3 DO 24 Vac, 12VA, Triac (non-powered enables hot/neutral field wiring) 1 Siemens GDE (44 lb-in) Actuator 588-524 588-525 Accessories Product Number Predator Room Sensors Sensing Only 587-180 Bypass 587-181 Setpoint 587-182 Temperature Display 587-183 1 Setpoint and Bypass 587-184 Bypass and Temperature Display 587-185 1 Setpoint and Temperature Display 587-186 1 Setpoint, Bypass and Temperature Display 587-187 1 1 Sensor will display Fahrenheit or Celsius temperature. DIN Rail mounting Clips of 50 587-150 4.7K Ohm Resistor, 100 Pack 587-151 4-20 ma 500 Ohm Resistor, 100 Pack 587-152 Black Termination Kit (10 2 position, 10 3 position, 20 6 position) 587-171 Green Rising-Cage Termination Kit (10 2 position, 10 3 position, 20 6 position) 587-171RC Predator VAV Actuator Model 1201 Connector and Mount Kit 587-172 Predator VAV Actuator Model 2301 Connector and Mount Kit 587-174 Predator LON Connector Kit, 10 Pack 587-173 Talon Network Interface Adapter (use as connector between Lon network cable from the service tool to the room sensor) 587-856 No Logo Predator Room Sensors Sensing Only 587-550B Setpoint 587-552B Setpoint and Bypass 587-554B Page 11 of 13

Setpoint, Bypass and Temperature Display 587-557B Accessories, continued Product Number 10 K Thermistor Sensors Duct Temperature Sensor, point, 10 K NTC, 4 probe 587-691 Duct Temperature Sensor, averaging, 10 K NTC, 24 flex 587-694 Pipe Temperature Sensor, immersion well, 10 K NTC, with 2.5 s.s. well 587-693 Pipe Temperature Sensor, strap-on, 10 K NTC 587-695 Outdoor Air Temperature Sensor, point 10 K NTC, with shield 587-692 Flush Mount Room Sensor Metal Flush Mount Room Temp Sensor, 10 K Thermistor 540-984 Warmer/Cooler Room Sensor Room Temp Sensor, w / term. Blocks, warmer/cooler set point adjustment 587-188 Room Temp Sensor, w / term. Blocks, warmer/cooler set point adjustment, occupancy override Room Temp Sensor, w / term. Blocks, warmer/cooler set point adjustment, occupancy override, LCD Display 587-189 587-196 Remote Mount Differential Pressure Sensors DP Sensor 0-5 w.c. 590-501 DP Sensor 0-2 w.c. 590-502 DP Sensor 0-1 w.c. 590-503 DP Sensor 0-0.5 w.c. 590-504 DP Sensor 0.25 to.25 w.c. 590-505 DP Sensor 0-5 w.c. in conduit box 590-506 DP Sensor 0-2 w.c. in conduit box 590-507 DP Sensor 0-1 w.c. in conduit box 590-508 DP Sensor 0-0.5 w.c. in conduit box 590-509 DP Sensor 0.25 to.25 w.c. in conduit box 590-510 Low Flow Remote Mount DPS 0.25 w.c. 590-511 Low Flow Remote Mount DPS 0.25 w.c. in conduit box 590-512 Page 12 of 13

TALON Architecture Notice: Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Credits: Raptor, Predator, and TALON are trademarks of Siemens Industry, Inc. Other products and company names herein may be the trademarks of their respective owners. Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 Phone 847-215-1000 www.staefa.com Copyright 2009 by Siemens Industry, Inc. Page 13 of 13