CERTIFICATE OF COMPLIANCE

Similar documents
Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Certificate of Compliance to IEC 61508

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

UL HAZARDOUS LOCATIONS SERVICES

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Certificate of Compliance

Certificate of Compliance

CERTIFICATE OF COMPLIANCE

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Temperature Measurement Transmitters for field mounting

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Quick Start Guide For the

Certificate of Compliance

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Certification Supplement Manual

Guide for hazardous areas

Annubar Flowmeter Series

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 4088B MultiVariable Transmitter with Bristol Standard Asynchronous/Synchronous Protocol (BSAP)/MVS Protocol

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 644 Temperature Transmitter

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Certificate of Compliance

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

APPROVAL REPORT. J.l. 3ZOA9.AX

Certificate of Compliance

Certificate of Compliance

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Quick Start Guide , Rev DA June Rosemount 644H (Device Revision 7 or Previous) and 644R Smart Temperature Transmitters

Hazardous Area Classifications and Protections

Rosemount 248 Temperature Transmitter

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 644H Temperature Transmitters

Rosemount 3144P Temperature Transmitter

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Rosemount 644H Temperature Transmitters

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 752 Fieldbus Remote Indicator

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 752 Remote Indicator

PANELBOARD PROTECTION ON A GLOBAL SCALE

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

Rosemount 3051 Pressure Transmitter

Rosemount 3051S MultiVariable Extension Supplement

Rosemount 2051G Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Certification Supplement Manual

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Rosemount 644H Temperature Transmitters

Certificate of Compliance

Instruction MI November I/A Series Temperature Transmitter Model RTT80-T with HART Version 6 Protocol

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

MT5000 Guided Wave Radar Level Transmitter. State-of-the-art loop powered, 4-20 ma output guided wave radar transmitter for liquid level applications

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter

S5000 Gas Monitor. GMS5000.com

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter

An Urgent Bulletin from CSA Group

Certificate of Compliance

STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D

Rosemount 848T High Density Temperature Measurement Family

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Brooks MT3750 Low Flow Armored Flowmeter

Rosemount 3144P Temperature Transmitter

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Integrated Solutions Low Voltage Systems

Ar-Mite TM Low Flow Armored Flowmeter

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Certificate of Compliance

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

INSTRUCTION & SERVICE MANUAL

COMPACT FLAME CONTROLLER CFC 2000

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 3144P Temperature Transmitter

Specifying Temperature Sensors for Hazardous Areas

FLASHLIGHT ANSI STANDARDS

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

ULTIMA X5000. MSAX5000.com

Explosion Proof Combination Signal db (A) / 5 Joule

Rosemount 3051 Pressure Transmitter and Rosemount 3051CF Series Flowmeter

official distributor of Newson Gale Ltd.

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

Transcription:

FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: FCa4cF1Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 XP-IS / I / 1 / ABCD / T6 T1* - 3KXF000028G0009; DIP / II, III / 1 / EFG / T6*; I / 1 / AEx d ia / IIC / T6 T1* - 3KXF000028G0009; 21 / AEx ia tb / IIIC / T80 C* - 3KXF000028G0009 h = material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; single digit alpha numeric code not critical to safety j = Density Calibration; single digit numeric code not critical to safety k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; D1, D2, D3, D4, D5, D6, D7, or D8 Additional Output 1; DRN, DRG, DRA, or DRT Page 1 of 7

FCa4cF1efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6*; I / 1 / AEx d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 e = Connection Design/Connection Box Material/Cable glands; U1, U2, A1 or A2 h = Material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; 2-digit alpha code not critical to safety j = Density Calibration; 2-digit numeric code not critical to safety l = Outputs; Y0 m = Power Supply; Y FCT4cF1klm CoriolisMaster Transmitter only XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6*; I / 1 / AEx d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; R1, R2, R3, R4, R5, R6, R7, or R8 Page 2 of 7

Additional Output 1; DRN, DRG, DRA, or DRT FCa4cF2Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / AEx na / IIC / T6 T1* h = material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; single digit alpha numeric code not critical to safety j = Density Calibration; single digit numeric code not critical to safety k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; D1, D2, D3, D4, D5, D6, D7, or D8 Additional Output 1; DRN, DRG, DRA, or DRT 3. When m = C provision shall be made external to the equipment, to provide the transient protection device to be set at a level not exceeding 140 % of the peak rated voltage value of 42 V. Page 3 of 7

FCa4cF2efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / AEx na / IIC / T6 T1*, IP68 e = Connection Design/Connection Box Material/Cable glands; U1, U2, A1 or A2 h = Material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; 2-digit alpha code not critical to safety j = Density Calibration; 2-digit numeric code not critical to safety l = Outputs; Y0 m = Power Supply; Y FCT4cF2klm CoriolisMaster Transmitter only NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / AEx na / IIC / T6 T1* k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; R1, R2, R3, R4, R5, R6, R7, or R8 Additional Output 1; DRN, DRG, DRA, or DRT Page 4 of 7

3. When m = C provision shall be made external to the equipment, to provide the transient protection device to be set at a level not exceeding 140 % of the peak rated voltage value of 42 V. Equipment Ratings: FCa4cF1Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups ABC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIC; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA12.27.01 FCa4cF1efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA12.27.01 FCT4cF1klm CoriolisMaster Transmitter only Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Page 5 of 7

FCa4cF2Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 FCa4cF2efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 Nonincendive for Class I, II and III, Division 2, Groups ABCDEF&G; Type of protection na for Class I, Zone 2, Group IIC Hazardous (Classified) Locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA12.27.01 FCT4cF2klm CoriolisMaster Transmitter only Nonincendive for Class I, II and III, Division 2, Groups ABCDEF&G; Type of protection na for Class I, Zone 2, Group IIC Hazardous (Classified) Locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. FM Approved for: ABB Automation Products GmbH Göttingen, Germany Page 6 of 7

This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: FM Class 3600 2011 FM Class 3610 2010 FM Class 3611 2004 FM Class 3615 2006 FM Class 3616 2011 FM Class 3810 2011 ANSI/ISA 12.27.01 2005 ANSI/NEMA 250 2003 ANSI/ISA 60079-0 2008 ANSI/ISA 60079-1 2013 ANSI/ISA 60079-11 2009 ANSI/ISA 60079-15 2014 ANSI/ISA 60079-31 2012 ANSI/IEC 60529 2013 ANSI/ISA 61010-1 (82.02.01) 2009 Original Project ID: 0003050239 Approval Granted: October 22, 2015 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date RR203300 December 29, 2015 FM Approvals LLC J.E. Marquedant Manager of Electrical Systems 29 December 2015 Date Page 7 of 7