For Tutorials and Troubleshooting visit

Similar documents
OVER 55 YEARS OF STEAM SHOWER INNOVATION

OVER 55 YEARS OF STEAM SHOWER INNOVATION

Signature Series Control

Installation Instructions PRO SERIES

One Touch Control Installation and Operation Instructions

Elite Control Installation and Operation Instructions

Installation Instructions Day Spa Generator

ThermaSol PowerPak Series Installation & Operating Instructions Commercial Steam Bath Generators (Three Phase)

Figure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -

POWER PAK 480V Commercial Steam bath Generator

FREWIN STEAM SHOWER ENCLOSURE

ARLEY STEAM SHOWER ENCLOSURE

Electrical Installation Instructions

LEVENS STEAM SHOWER ENCLOSURE

SYSTEM BASIC WHIRLPOOLS

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

Installation Manual PS-225 & PS-275

NEOSAUNA SERENITY SAUNA INSTRUCTION MANUAL Read all instructions carefully before using this wooden sauna room SKUS: SAU-SER-4C-B, SAU-SER-4C-C

Installation, Operation & Maintenance Manual. isteam. Controls. mr.steam. Feel Good Inc.

Installation Manual PS-200 & PS-201

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

SK SERIES INSTALLATION INSTRUCTIONS 1

Infrared sauna SUN S Pure Infra User Manual

signals a situation where minor injury or product damage may occur if you do not follow instructions.

CORALAIS BODYSPA BATH AND SHOWER FAUCET

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

User manual Whirlpool

INSTALLATION AND USER MANUAL

Find thousands more great ideas online

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

Destination Collection Whirlpool Bath Installation Instructions

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

Installation Instructions Acrylic Shower & Tub-Shower Modules Fax on Demand #4010

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

AQUAPEUTICS MONACO INSTALLATION MANUAL

Whirlpool Bathtub Model Number: MT618

SYSTEM INSTALLATION AND SERVICE AT AND 3T STEAMERS

Installation Guide BUBBLEMASSAGE. English page T01-A

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

Installation and Operation Manual

Cable Drain & Cable Drain Trim Kit

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-670EX/E300-CX

Headquarters & Technical Support 1958 Steam Way, Round Rock, TX (800) Mon Fri 7:00 7:00 CST Fog-Free Mirrors

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

OWNER S MANUAL ONE-PERSON & TWO-PERSON SAUNAS WITH CERAMIC OR CARBON HEATERS

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

ATTENTION INSTALLER: Please deliver this manual to homeowner.

NEPTUNE Steam Room Installation Instructions

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4010B 4011B

SUPPLEMENTARY INSTRUCTIONS

Fleck 5600 Carbon Filter Installation & Start Up Guide

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI80

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

E2 Series Installation

Hydrotherapy Jets (Remote Water Quality System)

Threaded Faucet Installation

WizCG grinder. WizlingCG grinder INSTRUCTION MANUAL

AT and 3T STEAMBATH GENERATORS For Models 4kW thru 14kW With T100 Control (Includes Optional Warm Start)

Owners Manual. Pub. No. 601-D

Kallista Bath Flip Drain

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

INFRARED SAUNA ROOM. Thank You for purchasing Our American Made Product! Proudly Made in the USA! PRECISION THERAPY 4 PERSON SAUNA USER MANUAL

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

Acrylic Claw Foot Tub

Clean Water Made Easy

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

INSTALLATION INSTRUCTIONS

ODEON OVE. A. Ordering Information. B. Required Electrical Service T01-C INSTALLATION INSTRUCTIONS

Steamist Installation Guidelines

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

Factory Direct Walk-In Tubs WALK-IN TUB. Installation Manual. For Model Numbers VT2848, VT2853, VT3153 and VT3255

Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

DISCONTINUED. Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

Sauna & Steam. STEAM GENERATOR (Domestic & Light Commercial) Assembly and operating manual PRODUCT IMAGE

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

How To: PREPARATION REPLACE A KITCHEN SINK

OWNER S MANUAL THREE-PERSON & FOUR-PERSON CORNER SAUNAS

Installation Instructions

SuperKlean Washdown Products

Dear Customer, The whole TheraSauna team is looking forward to serving your needs.

Audi-Larm Audible Alarm

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

Laurel Mountain Whirlpools. Walk-In Bathtub Installation Manual

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

SAVE THESE INSTRUCTIONS

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Infrared Room Installation & Operation Instructions

1.6 GALLON ONE PIECE TOILET

Transcription:

MicroTouch Control +Steamhead Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions MTT-NTS-XX Tradtional, MTM-NTS-XX Modern, MTMR-NTS-XX Modern Recessed, MTC-NTS-XX Contemporary, MTR-NTS-XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION

MicroTouch Control Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions From top - L to R: MTC-XX Contemporary, MTT-XX Tradtional, MTM-XX Modern, MTR-XX Regency, MTMR-XX Modern Recessed OVER 55 YEARS OF STEAM SHOWER INNOVATION

MicroTouch Control Installation Instructions 1 Important Information before You Install The MicroTouch Control must be installed inside the shower. The MicroTouch control will only function on the current SSM, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead. IMPORTANT: When locating and installing the MicroTouch, it is required to not place the control under any water-outlets, shower heads or in the direct path of flowing water. SEE DIAGRAM FOR LOCATION EXAMPLE. PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH. PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH. STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON, UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD. NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE "ON" POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH. DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH. YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY. IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP, IMMEDIATELY EXIT THE STEAM ROOM. DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT. THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES. THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME. All products must be installed in accordance with installation instructions provided. Failure to do so may invalidate warranty at manufacturer s discretion. 2016 ThermaSol. 81193_NC 4/16 Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 3

MicroTouch Control Installation Instructions 2 Tools and Materials Parts enclosed Controller (Contemporary style shown here) Silicone Mud Ring (RIK-TPMR-1) for MTMR-XX installation only Installation instructions, warranty, static cling warning label Materials needed: o MicroTouch control o CAN bus cable (included with generator o Silicone o Other materials as required Tools needed: o 1/2 drill for surface mount o Follow pre-installation instruction on page 5 for recessed mount controls o Drill motor o Other tools as required 3 Control Installation and Data Cable Connection Surface Mount Installation MTC-XX, MTM-XX, MTT-XX, MTR-XX, MTC-NTS-XX, MTM-NTS-XX, MTT-NTS-XX, MTR-NTS-XX Recessed Mount Installation MTMR-XX, MTMR-NTS-XX Data cable to generator Shower wall Shower wall Data cable to generator Make a 1/2" diameter hole in the desired location. The control should be installed 60" from the floor of the shower and away from the steamhead. Install recessed control mud-ring (provided with control) during rough-in stage of wall preparation. Fabricate and install materials as precise as possible, following the shape of the mud-ring. See page 5 for detailed instructions. 81193_NC 4/16 Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 4

MicroTouch Control Installation Instructions 4 Control Installation and Data Cable Connection Back of Control Route the data cable (included with generator) through the finished wall to the back side of the control. The other end of the cable runs to the steam generator location or if present to SWM-2 or PDM. NOTE: It is recommended to run the cable through electrical conduit. Connector Detail Back of control or side of generator "ON" Turn Clockwise "OFF" Turn Contact pins Contact pins Cable ends Counter Clockwise DO NOT pinch, nail, staple, wedge, or bind the data cable. DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable. Any damage to the control cable will result in the control not working properly. Carefully connect the data cable to the generator and control BEFORE turning power on to the generator. Back of control or side of generator Side of generator Do not staple, strain or damage data cable Align pins to receptacle visually before tightening Do not force plug Hand tighten only Connect the data cable to steam generator connector. (The other end of the cable runs to the back of the control in the the shower location or to the SWM-2 or PDM if present. Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 81193_NC 4/16 5

MicroTouch Control Installation Instructions 5 Mud Ring Installation + Sealing Control For Recessed Control Only (MTMR-XX and MTTR-NTS-XX) Silicone (included) Recessed Control (shown) Step 1: BEFORE TILE - Use the supplied mud ring by attaching to wall face using a few standard screws. Then tile to the edge of the mud ring. Data Cable Step 2: Once finished tile is completed remove mud ring from wall. Ensure that the total minimum depth is 5/8 so control face sits flush to wall. Connect cable so it is not lost in wall. Test fit for flushness. Step 3: IMPORTANT: Fully test the control system prior to silicone. Once desired fit is achieved coat back of control face with supplied silicone. Firmly press to wall surface and wipe excess silicone from around control. Tape into LEVEL position and let dry for 24 hours before using steam bath. Sealing Control For Surface Controls Only (MTC-XX, MTM-XX, MTT-XX, MTR-XX, MTC-NTS-XX, MTM-NTS-XX, MTT-NTS-XX, MTR-NTS-XX) 1/2" hole for surface mount Step 1: Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall. Completely seal the control to the wall so moisture does not collect behind it. Step 2: Place the control on the wall pressing firmly. (You may need to tape the control into place until the silicone dries.) Be careful not to harm the wall or control with the tape. Let dry for 24 hours before using steam bath. IMPORTANT: Fully test the control system prior to silicone. Surface Mount Control (shown) Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 81193_NC 4/16 6

MicroTouch Control Installation Instructions 6 Operation A B Taking a Steam Bath On your ThermaSol MicroTouch Control, touch and release the power icon twice to power on. To turn off the steam unit touch and release the power icon once. Power on is verified when the control face shows lit LEDs and turns dark if power is off. A steam session lasts 45 minutes and is loaded with previously saved temperature set point. Setting or Changing the Temperature Set Point Set the temperature of your ThermaSol steam shower by using the lit plus + or minus symbols, which are located immediately to the left and to the right of the power icon. An arc array of lit squares will appear from left to right. C Power Flush ThermaSol s internal diagnostic system will alert you when a Power Flush cleaning is needed (Maintenance mode) by LEDs running counterclockwise. Start a Power Flush cleaning cycle To start a power flush manually, press and hold the + and buttons for 5 seconds while the MicroTouch is in the on state. To indicate that the unit is in power flush mode, the array LEDs will flash in a clockwise direction. Increase the temperature by touching + symbol until desired temperature is displayed by the blue LED lights running clockwise to indicate an increase in temperature. Reduce the temperature by touching symbol and the array of LEDs will begin to turn off. Error Codes The simplified error code reporting system includes individual codes for any applicable system fault. + LEDs will blink to show an error The number of lit LEDs on the temperature scale shows the type of error. 1 light Room Over Temperature Error Bright LED Display Capacitive Touch Area Maintenance mode indicated by counter clockwise LEDs Built-in Infrared Temperature Sensing (ITS) Temperature Adjustment +/- B C 2 lights Reserved for Factory Use 6 lights Low AC Voltage Error 7 lights Low Water Error 8 lights Reserved for Factory Use 9 lights Reserved for Factory Use 10 lights Communication Error Power On/Off A Solid Aluminum Body Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 81193_NC 4/16 7

MicroTouch Control Installation Instructions 7 Trouble Shooting, Tutorials and Error Codes Visit www.thermasol.com/solutions. Click on Troubleshoot then click on MicroTouch Control Error Codes Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 81193_NC 4/16 8

Steamhead Installation Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions From top: NTST-XX Traditional, NTSM-XX Modern, NTSC-XX Contemporary, NTSR-XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION

Steamhead Installation Instructions 2 Tools and Materials Parts enclosed Steamhead (Contemporary style shown here) Silicone Installation instructions Materials needed: o Steamhead o Steamhead Rough-In Housing 1/2" Copper Tubing (For PRO-650, PRO-850-3/4" drop elbow, 3/4" Copper Tubing 50' max. (2) 3/4" to 1/2" adapters) o Silicone o Other materials as required Tools needed: o 1" deep socket and ratchet o 2 1/2" Masonry/tile/stone Hole Saw 3 Steamhead Location Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fitting! INSTALL steamhead as far as possible from the inshower controller. NEVER install the steamhead under controller A Install the steamhead 12" from the floor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible. i. For retrofit to existing finish wall: Drill a 2-1/2" diameter hole in the shower wall or wall above bathtub rim for the steam outlet roughin fitting and install to be flush with the finished wall. (plumbing must be done from backside of finshed space) ii. For new framing: Mount and install rough-in fitting to be flush with finished wall. B Connect a 1/2" NPT brass pipe or copper tubing to the steam outlet union (not included) on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough-in. For PRO-650 and PRO-850 run 3/4" copper steam line. It is very important that the pipe is firmly secured to the wall, so that when the steamhead is installed it doesn t push the rough-in fitting back into the wall. Install a 1/2 dropear elbow on the end of the 1/2 pipe or tubing for the rough-in fitting. For all the connections, use solder for copper joints and Teflon tape for pipe fittings and do not over tighten fittings. DO NOT USE PVC CEMENT. For detail installation instructions of the steamhead please see Installation section in thermasol.com/customersupport Upon final installation mount steamhead with facing up to allow aromatherapy well to dispense steam. A Aromatherapy Fill Channels Place silicone around groove Steamhead rough-in fitting to be installed flush with finished wall B Parts provided by installer O-Rings 81193_NC 4/16 Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 10

Steamhead Installation Instructions 4 Steamhead Installation A B When finalizing installation, install the steamhead into the housing, making sure that the aromatherapy fill channels are facing upwards. To ensure that no moisture gets behind the steamhead and into the wall, place a generous bead of waterproof silicone around the steamhead, using the machined groove (located on the back of the steamhead) as a guide. C D Be sure there isn t any debris within the housing, and that the two O-rings are in place on the steamhead. Press the steamhead into the housing until the steamhead is tight against the finished wall. You may need to wipe away any excess silicone. A Make sure aromatherapy fill channels face up This edge must be flush with finished wall (+/- 1/8") D Finished wall B Place silicone around this groove Finished wall C O-rings 3.5".63" 3.5".63" 3.75".63" 3.75".63" Contemporary Traditional Modern Regency 81193_NC 4/16 Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 11

1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 SUPPORT@THERMASOL.COM WWW.THERMASOL.COM WWW.THERMASOL.COM/SOLUTIONS 81193_NC 4/16