MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

Similar documents
MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC Multi-Position, Internal Txv

MBR. Multi-Position. Modular Blower

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

MBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

REPAIR PARTS. HKR / HKA/ HKP Heater Kits

ComfortNet -Compatible

MBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

MBVC INTRODUCTION CHECKING PRODUCT RECEIVED BLOWER CABINET INSTALLATION INSTRUCTIONS NOTICE IF A 1 FLASH ERROR CODE OR AN EC HTR TOO LARGE ERROR IS

VERTICAL MOUNT AIR HANDLERS

AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

Your safety and the safety of others are very important.

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

INSTALLATION INSTRUCTION

Wiring Diagrams DIAGRAM INDEX

PRODUCT SPECIFICATIONS

Bosch BVA Series Air Handler

Installation Instructions

INSTALLATION INSTRUCTIONS

Product Data. Convertible Air Handlers 1 1/2 5Ton

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Variable Speed Convertible Air Handler 5 Ton

Wiring Diagrams Units Produced After April 20, 2009

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

MERIT Series R-410A - Upflow / Horizontal

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

TECHNICAL SPECIFICATIONS

HIGH EFFICIENCY AIR HANDLER

REPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only.

AVPTC**14** AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

TECHNICAL SPECIFICATIONS B6VMMX

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation Instructions

B SERIES ELECTRIC FURNACE

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL SPECIFICATIONS

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

PAR5. Product Specifications

Product Data. Convertible Air Handlers 1 1/2 5Ton

MERIT Series R-410A - Upflow / Horizontal

GMS9/GCS9 SERIES 93% AFUE

HIGH EFFICIENCY AIR HANDLER

Hyperion Field Reference Data TAM8

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Concealed Ducted Split Series R-407C MBH

AIR HANDLERS AIR HANDLERS

Transcription:

Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data... 4 Dimensions... 5 Wiring Diagram... 6 Product Features Variable-speed ECM blower motor ComfortNet Communicating System compatible Advanced configuration of the airflow and tonnage in communicating mode Provides constant CFM over a wide range of static pressure conditions independent of duct system CFM indicator Fault recall of six most recent faults Provides adjustable low CFM for efficient fan-only operation Improved humidity and comfort control Built-in compatibility with multi-stage heat pump and cooling applications kw kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities " depth for easier attic access Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grain-embossed finish Cabinet air leakage less than % at.0 inch H₂0 when tested in accordance with ASHRE standard 9 Cabinet air leakage less than.4% at 0.5 inch H₂0 when tested in accordance with ASHRE standard 9 AHRI certified; E listed * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GMBVC www.goodmanmfg.com 4/6 Supersedes /5

Nomenclature MB VC 00 A A,,4 5,6 7,8 9 0 Design Series Electrical MB Modular Blower 08-0/60/ Motor Speed Revisions V Variable Speed A First Series C ComfortNet Compatible Circuit Breaker Airflow Delivered A No Circuit Breaker 08 800 CFM B Circuit Breaker 00 CFM 6 600 CFM Factory- installed Electric Heat 0 000 CFM 00 No Heat HKR * - 05 * A 4,5 Unit Type Revisions HKR Air Handlers & Packaged Units Engineering Revisions HKA Air Handlers HKP Packaged Units Circuit Breaker None Single- or - Phase Kit; Phase No Circuit Breaker None Single- Phase C Single- Phase Kit w/ Three- Phase Circuit Breaker Heating Capacity @ 40 Volts 5 4.75 kw 5 4.5 to 5.00 kw 8 7.00 kw 0 9.00 to 9.60 kw 0 9.50 kw www.goodmanmfg.com SS-GMBVC

Product Specifications Model MBVC00AA- MBVC600AA- MBVC000AA- Blower Diameter 0" 0" " Width 8" 8" 0" Electrical Data Voltage 08 / 0 08 / 0 08 / 0 Min Circuit Ampacity 4. 6. 5.8 Max. Overcurrent Device (Amps) 5 5 5 Blower Motor Horsepower (HP) ½ ¾ ¾ Ship Weight (Lbs.) 67 80 86 Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for these specifications with approved accessory heaters installed. SS-GMBVC www.goodmanmfg.com

Airflow Data Model Speed Tap Speed 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9 MBVC00A* MBVC600A* MBVC000A* A Low 40 45 400 400 95 90 90 90 80 B Low 550 545 540 540 55 50 50 55 50 C Low 680 675 670 665 660 655 655 650 640 D Low 80 805 800 800 800 795 790 785 785 A High 65 605 600 600 595 590 590 585 580 B High 805 805 800 800 800 795 790 785 780 C High 00 005 000 000 995 995 990 985 975 D High 0 05 00 00 00 95 95 90 80 A Low 690 680 670 665 660 655 65 595 575 B Low 850 80 800 795 790 785 775 750 75 C Low 980 970 940 95 90 90 890 865 860 D Low 0 085 070 055 045 05 000 990 975 A High 045 05 000 990 975 950 95 90 900 B High 45 5 00 80 75 65 50 0 5 C High 45 40 400 65 60 50 40 0 0 D High 605 600 600 540 50 50 50 500 490 A Low 85 85 800 800 795 795 790 775 750 B Low 075 070 070 065 050 045 045 040 05 C Low 0 05 00 00 95 90 90 85 75 D Low 45 40 40 0 0 5 5 05 05 A High 0 05 00 95 50 50 45 5 5 B High 60 605 600 540 55 55 50 50 50 C High 80 805 800 785 760 760 755 750 75 D High 00 00 000 995 995 970 970 965 955 S S Speed Tap Cooling and Heat Pump Airflow MBVC00 Airflow (SCFM) MBVC600 Airflow (SCFM) MBVC000 Airflow (SCFM) off off A 600 000 00 on off B 800 00 600 off on C 000 400 800 on on D 00 600 000 Heat Kit Airflow Cooling / HP / Aux Trim Cooling Profile S S4 Trim Value S5 S6 off off 0 off off A on off 0% on off B off on -0% off on C on on 0 on on D Notes The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. Use the CFM adjustment factors of.98 for horizontal left,.95 for horizontal right &.96 for downflow orientations. 4 www.goodmanmfg.com SS-GMBVC

Heat Kit Data Models Circuit Circuit Single-Point Kit Heater Amps MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP² MBVC00AA-A* HKR-0* HKR-05* / 05C* HKR-06* HKR-08* / -08C* HKR-0* / -0C* HKA-5C* 0 / 0 0.8 /.5 7. / 9.8.7 / 5.0 5. / 9. 4. / 9.6 4. / 9.6 4. / 4. 7.8 / 9.9 5.7 / 9.0. / 5.5 5.8 / 40.7 47. / 5.7 47. / 5.7 5 / 5 0 / 0 0 / 0 5 / 40 40 / 45 50 / 60 50 / 60 MBVC600AA-A* 0 / 0 6. / 6. 5 / 5 HKR-0* 0.8 /.5 9.8 /.9 0 / 5 HKR-05* / 05C* 7. / 9.8 7.7 /.0 0 / 5 HKR-06*.7 / 5.0. / 7.5 5 / 40 HKR-08* / -08C* 5. / 9. 7.8 / 4.7 40 / 45 HKR-0* / -0C* 4. / 9.6 49. / 55.7 50 / 60 HKA-5C* 4. / 9.6 49. / 55.7 50 / 60 MBVC000AA-A* 0 / 0 5.8 / 5.8 5 / 5 HKR-0* 0.8 /.5 9. /.4 0 / 5 HKR-05* / 05C* 7. / 9.8 7. / 0.5 0 / 5 HKR-06*.7 / 5.0.8 / 7.0 5 / 40 HKR-08* / -08C* 5. / 9. 7. / 4. 40 / 45 HKR-0* / -0C* 4. / 9.6 48.6 / 55. 50 / 60 HKA-5C* 4. / 9.6 48.6 / 55. 50 / 60 HKA-0C* 4. / 9.6 48.6 / 55. 50 / 60 All ampacities noted above include air handler motor amps Circuit : Single-phase for Air Handlers / Circuit : Three-phase for HKR Heater Kits ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X.5 ² Maximum Overcurrent Protection =.5 X Motor Amps + Heater Amps * Revision level that may or may not be designated 7. / 9.8.4 / 4.7 5 / 5 69/79 70 / 80 7. / 9.8.4 / 4.7 5 / 5 7/8 80 / 90 7. / 9.8.4 / 4.7 5 / 5 70/80 70 / 80 4. / 9.6 4.9 / 49.5 45 / 50 9/05 00 / 0 C = Circuit Breaker Option indicates Not Required Only applicable when HKA kits are included in table HKA meets the new UL995 requirements for 5 and 0KW heaters MBVC and MBR models Heating kw Correction Factor Supply Voltage 40 0 0 0 08 Correction Factor.00 0.9 0.84 0.77 0.75 Multiply the 40-volt heating capacity by correction factors. SS-GMBVC www.goodmanmfg.com 5

Dimensions Side and Front Views Model Dimensions Width Depth Height MBVC00AA- 7½" " 6" MBVC600AA- " " 0" MBVC000AA- 4½" " 0" Top View 8.840.09.78 0.59.09.09 6.500 0.0.464 7½" " 4½" MEDIUM LARGE 6 www.goodmanmfg.com SS-GMBVC

Wiring Diagram Air Handler PL PL 40 VA TRANSFORMER, SEE NOTE 0 VAC 08 VAC 4 VAC GN L L 6 6 5 5 4 4 7 7 8 8 9 9 SEE NOTE 7 GY COM WH BR 4 4 CIRCUIT HEATER CONNECTOR SEE NOTE 5 FAULT RECALL 4 C 4 CIRCUIT MOTOR CONNECTOR SEE NOTE 6 ECM MOTOR HARNESS W W CFM LED AF SELECT STATUS LED TRIM % COOL AF PROFILE LEARN SEE NOTE 6 DIP SWITCHES CONT FAN COM CAS SEE NOTE 8 7 SEGMENT DIAGNOSTIC DEHUM DISPLAY DEHUM ENAE TRIM ENAE TWO-STAGE INTEGRATED CONTROL MODULE CIRCULATOR OWER 4 5 TH 4 V A FUSE SEE NOTE 6 RX LED HTR KIT(KW) S S S S4 S5 S6 S7 S8 S9 S0 S S S 4 O Y Y W W GN G C R TR 4 V THERMOSTAT CONNECTIONS 4V THERMOSTAT CONNECTIONS R W W Y Y G O DISCONNECT DEHUM C L FUSE A TO MICRO INDOOR AIR CIRCULATOR WR 08/0 VAC L 40 VA TH TRANSFORMER 4 VAC W () HEAT COIL/R W () HEAT COIL/ R CAS () CONDENSATE SWITCH CAS () +VDC () RX () INDOOR AIR TX () CIRCULATOR WR (4) TR COM INTEGRATED CONTROL MODULE INTEGRATED CONTROL NOTES:. PLACE RED WIRES ON TRANSFORMER TERMINAL FOR 08 VAC OPERATION.. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 05 C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 6. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK. 7. DISCA CONNECTOR PL WHEN INSTALLING OPTIONAL HEAT KIT. 8. THE CONDENSATE ALARM SWITCH (CAS) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING MODE SETUPS AND MUST BE ENAED WITH A COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT OPERATIONAL WITH LEGACY SYSTEMS. USE N.E.C CLASS WIRE. LOW VOLTAGE (4V) LOW VOLTAGE FIELD HI VOLTAGE (0V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO EQUIPMENT FIELD FIELD SPLICE RESISTOR OVERCURRENT PROT. DEVICE PLUG CONNECTION COLOR CODES: PK - PINK BR - BROWN WH - WHITE - UE GY - GRAY - RED YL - YELLOW OR - ORANGE PU - PURPLE GN - GREEN - ACK 040A0044-B Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. SS-GMBVC www.goodmanmfg.com 7

Wiring Diagram Five-Element Heater Kit HTR COMPONENT CODE COLOR CODE PU HTR HTR YL HTR4 HTR5 PU M M4 M6 M7 YL M M M5 M8 PU M0 M9 PC 4 WH R PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL OCK CB = CIRCUIT BREAKER CC = CONTACTOR = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. OWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE = ACK = UE BR = BROWN GR = GREEN OR = ORANGE PK = PINK PU = PURPLE = RED WH = WHITE YL = YELLOW YL R R WH BR 5 6 7 8 9 PU NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS CB CB CB L L L L L L NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION CB4 L L 040M0074-A Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 06 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-GMBVC