For 18 SEER R410A Series Unitary Ducted Split AC

Similar documents
Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

CAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit

Installation Instructions

Installation Instructions

Installation Instructions

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Installation Instructions

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Installation Instruction

Installation Instructions

Installation Instructions

Installation Instruction

Installation Instructions

INSTALLATION INSTRUCTIONS R 410A

Installation Instruction

Installation Instructions

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioners

Installation Instructions

Installation Instructions

Wired Controller XK60

Installation Instructions

Installation Instructions

Installation Instructions

38TKB Air Conditioning Unit Installation and Start-Up Instructions

Installation Instructions

13 SEER Air Conditioner with R Single Phase Phase

Residential Piping and Long Line Guideline

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Fig. 1 - Unit PHD4 and WPH4

INSTALLATION / START-UP INSTRUCTIONS 4HP13/14 SPLIT SYSTEM HEAT PUMP HOMEOWNERS INFORMATION MANUAL

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Owner s Information Manual

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

Installation Instruction

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

38GHP AIR-COOLED MULTI SPLIT CONDENSING UNITS

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Safety Labeling and Signal Words

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

SPLIT SYSTEM HEAT PUMP INSTALLATION / START-UP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL

HEAT PUMP INSTALLATION MANUAL

Installation Instructions

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

Installation Instructions

Installation Instructions

For 13 SEER R410A Unitary Ducted Split AC & Heat Pump

Installation Instructions

Fig. 1 - Unit PGD4, PGS4, WPG4

Safety Labeling and Signal Words

Installation Instructions

Installation Instructions

38LB/38LF AIR COOLED CONDENSING UNIT

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Trade Mark Waterjet Chillers. User Manual & Installation Guide

Installation Instructions

INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner

Owner s Information Manual

User s Information/Installation Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP13LE Series Split System Heat Pump

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP16LT Series Split System Heat Pump

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

Installation Instructions

Installation Instructions Part No , Part No Part No

Transcription:

For 18 SEER R410A Series Unitary Ducted Split AC Thermostat Owner's Manual Commercial Air Conditioners Thank you for choosing MRCOOL, please read this owner s manual carefully before operation and keep it for future reference.

Contents Safety Considerations...1 1. Installation of the Wired Controller...2 2. Wiring Terminals of the Wired Controller...2 3. Main Page...3 4. Function Setting...3 4.1 ON/OFF...3 4.2 Mode...4 4.3 Fan...4 4.4 / (Temperature Adjustment)...4 4.5 SET (Parameters/Functions View and Setting)...5 4.6 Enter/Hold...9 4.7 Lock Function...10 4.8 Error Display...10 5 Installation Instructions... 11 5.1 Physical Dimension... 11 5.2 Installation Recommendations...12 5.3 Installation...13

Safety Considerations Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory--authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety--alert symbol.when you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing, modifying, or servicing system,main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances. 1

1. Installation of the Wired Controller 1 2 3 4 Fig.1 Installation Diagram Step 1: Press the button at the top of the wired controller to remove the front panel and the bottom plate. Step 2: Reinstall the bottom plate in accordance with the locating holes either shown in the figure above or decided by the user. Step 3: Conduct the wiring and see section 2 for more details. Step 4: Reinstall the front panel. 2. Wiring Terminals of the Wired Controller Fig 2 Wiring Terminals Diagram Table 1 Terminal Code Description C 24 Volt (Neutral) R 24 Volt Emergency (Hot) O Four-Way Valve G Indoor Unit Y1 Compressor 1 Y2 Compressor 2(Reserved) W1 Auxiliary Electric Heater 1 W2 Auxiliary Electric Heater 2 L Temperature Sensor Error Output A 485 Communication Port B 485 Communication Port 2

3. Main Page 4. Function Setting 4.1 ON/OFF Fig.3 Main Page 1 Fan 3 Cancel 5 7 Mode 2 Set 4 ON/OFF 6 8 Enter/Hold The controller can be turned on/off by pressing this button, with the corresponding ON/OFF symbol displayed. Fig.4 3

4.2 Mode One among various mode options can be selected by pressing the Mode button As for the cooling only unit, the switchover order of mode options is: E-HEATER COOL. As for the cooling and heating unit, the switchover order of mode options is: HEAT E-HEATER COOL Note: the unit type is identified by the main board of the unit. Fig. 5 4.3 Fan It is available to select the desirable fan option by pressing the Fan button Under the FAN ON option, the fan will always keep running. Under the FAN AUTO option, the fan will be automatically shut down or started up in accordance with the actual Mode and temperature. Fig. 6 4.4 / (Temperature Adjustment) Under the main page, the temperature for the current Mode can be adjusted by pressing the / button. During temperature adjustment, the temperature value will blink, with the symbol SET displayed. After the adjustment, it will automatically back to the main page and display the current environment temperature. 4

Fig. 7 4.5 SET (Parameters/Functions View and Setting) It is available to go the parameters/functions view and setting page by pressing the Set button, and then desired option can be selected by pressing the / button, finally go to the corresponding view and setting page by pressing the Enter/Hold button. Fig.8 Parameters/Functions View and Setting 4.5.1 DEMAND After accessing to the DEMAND page, it is available to select the desired parameter by pressing the / button. The upper value indicates the desired parameter, while the lower value indicates the parameter No. Fig.9 Table 2 Parameter No. Parameter Description 01 Compressor Runtime 02 Opening Angle of the Electronic Expansion Valve 03 Outdoor Environment Temperature 04 Tube Inlet Temperature of the Outdoor Unit 05 Tube Midway Temperature of the Outdoor Unit 5

06 Tube Outlet Temperature of the Outdoor Unit 07 Discharge Air Temperature of the Outdoor Unit 08 Preset Frequency 09 Running Frequency 10 IPM Radiator or IPM Temperature This page can quit by pressing the Enter/Hold button, The accumulated Compressor Runtime can be cleared by pressing the Mode button for five seconds. Note: when the accumulated Compressor Runtime exceeds 1500 hours, a symbol on the main page will be displayed to remind the user clearing the runtime. 4.5.2 TIME After going into the TIME page, it is available to adjust the time. Switch to the time value in the order of DAY HOUR MINITE, Adjust the blinking value by pressing the / button, After the MINUTE is set, press the Enter/Hold button for confirmation to make this setting come effective and back to the previous interface. If the setting is canceled prior to the confirmation, then the related parameter will not be saved and come into effect. Fig.10 4.5.3 TIMER It is capable of timing four periods for each day of one week, For instance: Table 3 No. Period Cooling Temperature Heating Temperature (Auxiliary Heating) Period 1 06:00 75.2F 69.8F Period 2 08:00 82.4F 62.6F Period 3 18:00 75.2F 69.8F Period 4 22:00 78.8F 62.6F When the unit is currently under the cooling mode, the temperature will be set to automatically at 06:00, at 8:00, at 18:00 and at 22:00. When the unit is currently under the heating or auxiliary heating mode, the temperature will be set to automatically at 06:00, at 8:00, 75.2F at 21:00 and 62.6F at 22:00. 1 After going to this function page, the day (like, SAT ) will blink and then adjust it through the 6

/ button. Fig. 11 2 After the day is set, press the Enter/Hold button to make a confirmation and then go to the time period setting status with the time period blinking and then select the desired one through the or button. Fig. 12 3 After the time period is selected, press the Enter/Hold button to make a confirmation and go the setting status for timing the time period with the HOUR blinking and adjust it through the / button. Sequentially, set the MINUTE in the same way. Fig.13 4 After the MIINUTE is set, press the Enter/Hold button to make a confirmation and go to the setting status for setting the temperature under the cooling mode and adjust it through the or button. 7

Fig.14 5 After the temperature under the cooling mode is set, press the Enter/Hold button to make a confirmation and go to the setting status for setting the temperature under the heating mode and adjust it through the or button. Fig.15 6 After that, press the Enter/Hold button to make a confirmation and go back to the page shown in step 2 and then repeat the steps 2~5 for setting other time periods. Fig.16 7 After the fourth time period is set, then all parameters of these four time periods will be saved and then back to the page for selecting the days of the week. Then, it is available to continue the setting on other days in the same way. Fig.17 8

Note: Only when four time periods have been set and the wired controller has backed to the page for selecting the day X, can the timing parameters be memorized together. If the setting quits or the power failure occurs, then the setting of the timing parameters on the day X comes invalid. 4.5.4 Func. Fig.18 After going into this page, the function No. blinks and then press the / button to switch the function No. Select the desired function No. and next press the Enter/Hold button for confirmation. After that, the value of the selected function No. blinks and adjust it by pressing the / button. Then press the Enter/Hold button again to save the setting and back to the previous page. This page will be canceled by pressing the Cancel button. Table 4 No Function Function Code Description ON: The function is activated. 01 Memory OFF: The function is deactivated C :Celsius scale 02 Temperature Unit F: Fahrenheit scale 03 Environment Temperature Compensation 04 Compressor Time Lag Protection 05 Default Reset 23F~41F temperature compensation in accordance with various environment and location. ON: the function is activated OFF: the function is deactivated. ON: the default is reset OFF: the default is not reset 4.6 Enter/Hold On the temperature adjustment page, it is available to active the Hold function by pressing the Enter/Cancel button, that is, the current setting temperature will be kept unchanged with the change of the setting temperature for each timing period. This function can be deactivated by pressing the Enter/Hold button again. When this function is activated, the current setting temperature will always be displayed. 9

Fig.19 4.7 Lock Function This function can be activated by simultaneously pressing the / button for five seconds on the main page, and be canceled by another press. 4.8 Error Display For instance, if the display board ambient temperature sensor error occurs, the error code F0 and related error symbol will be displayed. Table 5 Error List SN Error Code Error Description 1 F0 Indoor Ambient Temperature Sensor Error 2 E1 Compressor High Pressure Protection 3 E3 Compressor Low Pressure Protection 4 E4 Compressor Discharge Temperature Protection 5 E5 Compressor Overload Protection 6 E8 Over High Tube Temperature Protection of the Outdoor Unit 7 F2 Outdoor Unit Tube Temperature Sensor Error 8 F4 Discharge Temperature Sensor Error 9 e5 Main Board Discharge Temperature Sensor Error 10 F3 Main Board Ambient Temperature Sensor Error 11 E6 Communication between the Main Board and the Display Board 12 EE Main Board Memory Chip Error 13 c5 Jumper Error 14 PL DC Bus Under-voltage Protection 15 PH DC Bus Over-voltage Protection 16 PA AC Current Protection (Input Side) 17 H5 IPM Error 18 Hc PFC Error 19 Lc Startup Failure 20 P0 Drive Module Reset Failure 21 P5 Compressor Over-current 22 Pc Sensing Circuit Error or Current Sensor Error 23 H7 Compressor Motor Desynchronization 24 P6 Communication Error between the Main Board and the Drive 25 P8 IPM or PFC Over-temperature Protection 26 P7 IPM or PFC Temperature Sensor Error 10

27 ee Drive Memory Chip Error 28 PU Charging Circuit Error Technical Parameters Power Supply: 24V AC 50/60HZ Maximum Current: 1.5A ( Sensing Load ) Working Environment: Only applicable to indoor environment Working temperature: ~ Displayed Environment Temperature: 32F~ When the environment temperature is lower than 32F, the displayed value will be LO, When the environment temperature is higher than, the displayed value will be HI. The wired controller applied to the inverter unit can set the temperature from 0- at the COOL mode and 41-89.6F at the HEAT mode. However, 60.8-86F is the real range which can be recognized by the unit, that is, when the temperature is set to be under 60.8F, then 60.8F is the real set temperature; or when it is set to be above 86F, then 86F is the real set temperature. 5 Installation Instructions 5.1 Physical Dimension 5.1.1 Outdoor Unit C B A Fig 20 Outdoor Unit Diagram Table 6-Dimension of Outdoor Unit Unit: Inch Model A B C MAC18024 24-1/2" 24" 24" MAC18036 29" 28" 28" MAC18042 33-1/2" 28" 28" MAC18048 33-1/2" 29-1/2" 29-1/2" 11

E Unitary Ducted Split AC 5.1.2 Indoor Unit D C A Fig. 21 Indoor Unit Diagram Table 7-Dimension of Indoor Unit B Unit: Inch Model A B C D E MAH18024 21" 21-5/16" 10-3/4" 11-5/16" 43-1/2" MAH18036 21" 21-5/16" 12-1/4" 11-5/16" 48-3/16" MAH18042 24-1/2" 21-5/16" 13-3/4" 11-1/2" 48-3/16" MAH18048 24-1/2" 21-5/16" 13-3/4" 11-1/2" 48-3/16" 5.2 Installation Recommendations NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment. 1. Locate unit away from windows, patios, decks, etc. where unit operation sound may disturb customer. 2. Ensure that vapor and liquid tube diameters are appropriate for unit capacity. 3. Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends. 4. Leave some slack between structure and unit to absorb vibration. 5. When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon--based caulk.(see Fig. 22.) 6. Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls. 7. Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing. (See Fig. 22.) 8. Ensure that tubing insulation is pliable and completely surrounds vapor tube. 9. When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 22.) 10. Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation. When outdoor unit is connected to factory--approved indoor unit, outdoor unit contains system 12

refrigerant charge good for 25 ft. For proper unit operation, check refrigerant charge using charging information located on control box cover and/or in the Check Charge section of this instruction. NOTE: Avoid contact between tubing and structure OUTDOOR WALL INDOOR WALL CAULK LIQUID TUBE INSULATION THROUGH THE WALL HANGER STRAP (AROUND VAPOR TUBE ONLY) VAPOR TUBE JOIST INSULATION VAPOR TUBE 1 MIN. LIQUID TUBE SUSPENSION Fig.22 Connecting Tubing Installation 5.3 Installation 5.3.1 Check Equipment & Jobsite Unpack Unit Move to final location. Remove carton taking care not to damage unit. Inspect Equipment File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate. It contains information needed to properly install unit. Check rating plate to be sure unit matches job specifications. 5.3.2 Install on a Solid, Level Mounting Pad For hurricane tie downs, contact distributor for details and PE Certification (Professional Engineer), if required. On rooftop applications, mount on level platform or frame. Place unit above a load--bearing wall and isolate unit and tubing set from structure. Arrange supporting members to adequately support unit and minimize transmission of vibration to building. Consult local codes governing rooftop applications. NOTE: Unit must be level to within ±2 (±3/8 in./ft.) per compressor manufacturer specifications. 5.3.3 Clearance Requirements When installing, allow sufficient space for airflow clearance, wiring, refrigerant piping, and service. Allow 30 inch clearance to service end of unit and 48 inch above unit. For proper airflow, a 6 inch clearance on 1 side of unit and 12 inch on all remaining sides must be maintained. Maintain a distance of 24 inch between units. Position so water, snow, or ice from roof or eaves cannot fall directly on unit. On rooftop applications, locate unit at least 6 inch above roof surface. 5.3.4 Operating Ambient The minimum outdoor operating ambient in cooling mode is 67 F, and the maximum outdoor operating ambient in cooling mode is 115 F. 13

5.3.5 Elevate Unit CAUTION UNIT OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation. Unit must be kept free of an accumulation of water and/or ice in the basepan. Elevate unit per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate drainage of unit. If using accessory support feet, use installation instructions from kit for installation. 5.3.6 Make Piping Connections WARNING PERSONAL INJURY AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow-control devices, including solenoid valves. CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. If ANY refrigerant tubing is buried, provide a 6 inch vertical rise at service valve. Refrigerant tubing lengths up to 36 inch may be buried without further special consideration. Do not bury lines longer than 36 inch. CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. To prevent damage to unit or service valves, observe the following: Use a brazing shield Wrap service valves with wet cloth or use a heat sink material. Outdoor units may be connected to indoor section using accessory tubing package or field- -supplied refrigerant grade tubing of correct size and condition. For tubing requirements beyond 80ft., substantial capacity and performance losses can occur. Follow the recommendations in the Long Line Guideline for long line application. Refer to Table 8 for accessory requirements. Refer to Table 9 for field tubing diameters. If refrigerant tubes or indoor coil are exposed to atmosphere, they must be evacuated to 500 microns to eliminate contamination and moisture in the system. Table 8 Accessory Usage Accessory Required for low-ambient applications(below 55 F) Required for long line applications(over 80 ft.) Required for sea coast applications(within 2 miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No 14

Winter Start Control Yes No No Accumulator No No No Motor Master Control Yes No No Support Feet Recommended No Recommended Table 9 Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters(In.) UNIT SIZE Liquid Vapor Connection Diameter Tube Diameter Connection Diameter Rated Tube Diameter 24 3/8 3/8 5/8 5/8 36 3/8 3/8 3/4 3/4 42 3/8 3/8 7/8 7/8 48 1/2 1/2 7/8 7/8 Outdoor Unit Connected to Factory Approved Indoor Unit These outdoor units are carefully evaluated and listed with specific indoor coils for proper system performance. IMPORTANT: Do not apply indoor coils which are not factory approved to these units CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Service valves must be wrapped in a heat-sinking material such as a wet cloth. CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Installation of filter drier in liquid line is required. Install Liquid Line Filter Drier Indoor Refer to Fig. 23 and install filter drier as follows: 1. Braze 5 inch liquid tube to the indoor coil. 2. Wrap filter drier with damp cloth. 3. Braze filter drier to 5 inch long liquid tube from step 1. 4. Connect and braze liquid refrigerant tube to the filter drier. Fig.23 Liquid Line Filter Drier 15

Leak Testing Leak test all joints indoors, outdoors, and refrigerant tubing. Evacuate Refrigerant Tubing and Indoor Coil CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Never use the system compressor as a vacuum pump. Refrigerant tubes and indoor coil should be evacuated using the recommended deep vacuum method of 500 microns. The alternate triple evacuation method may be used if the procedure outlined below is followed. IMPORTANT: Always break a vacuum with dry nitrogen. Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum of 500 microns and a vacuum gage capable of accurately measuring this vacuum depth. The deep vacuum method is the most positive way of assuring a system is free of air and liquid water. See Fig. 24. Fig.24- Deep Vacuum Graph Fig.25 Triple Evacuation Method 16

Triple Evacuation Method The triple evacuation method should only be used when vacuum pump is only capable of pumping down to 28 inch of mercury vacuum, and system does not contain any liquid water. Refer to Fig. 25 and proceed as follows: 1. Pump system down to 28 inch of mercury and allow pump to continue operating for an additional 15 minutes. 2. Close service valves and shut off vacuum pump. 3. Connect a nitrogen cylinder and regulator to system and open until system pressure is 2 psig. 4. Close service valve and allow system to stand for 1 hour. During this time, dry nitrogen will be able to diffuse throughout the system absorbing moisture. 5. Repeat this procedure as indicated by Fig. 25. System will then be free of any contaminants and water vapor. Final Tubing Check IMPORTANT: Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment. Ensure tubes are not rubbing against each other or any sheet metal. Pay close attention to feeder tubes, makings sure wire ties on feeder tubes are secure and tight. Refrigerant Charge Determination and Adjustment Weight in Charge Method The unit was pre-charged good for 25 ft application, if the line set longer than 25ft, please refer to the following table for additional charge. Table 10 Liquid line size (inch) Additional charge for every additional foot (oz) 3/8 0.32 1/2 0.64 Superheat Method Table 11 SYSTEM SUPERHEAT Ambient Condenser Return Air Temperature( F Dry bulb) Inlet Temp( F Dry bulb) 65 70 75 80 85 115 11 100 11 26 95 20 18 27 90 19 24 33 85 28 29 33 34 80 29 31 33 34 75 29 30 33 34 35 70 29 34 37 36 36 65 32 35 39 39 42 60 34 37 39 42 43 17

5.3.7 Make Electrical Connections NOTE:The signal line of the wired controller must be separated from the power line and the connecting line between the indoor unit and the outdoor unit. WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Do not supply power to unit with compressor termial box cover removed. Be sure field wiring complies with local and national fire, safety, and electrical codes, and voltage to system is within limits shown on unit rating plate. Contact local power company for correction of improper voltage. See unit rating plate for recommended circuit protection device. NOTE: Operation of unit on improper line voltage constitutes abuse and could affect unit reliability. See unit rating plate. Do not install system where voltage may fluctuate above or below permissible limits. NOTE: Use copper wire only between disconnect switch and unit. NOTE: Install branch circuit disconnect of adequate size per NEC to handle unit starting current. Locate disconnect within sight from and readily accessible from unit, per Section 440 14 of NEC. WARNING: A separate air switch must be furnished for the external power supply of the unit, otherwise it would cause damage to the unit or bodily injury or even death. Table 12 Model Number Minimum Circuit Ampacity- MCA(amps) Maximum Over Current Protective device- MOCP(amps) Compressor LRA/RLA Capability of Air Switch(A) Minimum Sectional Area Of Earth Wire(mm2 (Outdoor/Indoor) MAC18024 15 16.9 -/9.7 15 2.1 MAC18036 24 30.7 -/13.2 30 3.3 MAC18042 24 35.4 -/13.2 30 3.3 MAC18048 30 48.8 -/21.0 45 5.3 Route Ground and Power Wires Remove access panel to gain access to unit wiring. Extend wires from disconnect through power wiring hole provided and into unit control box. WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes. 18

Wiring Diagram: OUTDOOR UNIT SYMBOL NAME XT1/XT2 TERMINAL BOARD AP MAIN PCB L1/L2 INDUCTOR COMP COMPRESSOR M FAN MOTOR C FAN CAPACITOR EKV ELECTRONIC INFLATE VALVE HP HIGH PRESSURE SWITCH LP LOW PRESSURE SWITCH SAT COMP. OVER LOAD RT1 COMP. TEMP. SENSOR RT2 ENVIRONMENT TEMP. SENSOR RT3 DISCHARGE GAS TEMP. SENSOR Fig. 26 Electric Wiring of the Outdoor Unit(MAC18024) OUTDOOR UNIT SYMBOL NAME XT1/XT2 TERMINAL BOARD AP MAIN PCB L1/L2 INDUCTOR COMP COMPRESSOR M FAN MOTOR C FAN CAPACITOR EKV ELECTRONIC INFLATE VALVE HP HIGH PRESSURE SWITCH LP LOW PRESSUR SWITCH SAT COMP. OVER LOAD RT1 PIPE TEMP. SENSOR RT2 ENVIRONMENT TEMP. SENSOR RT3 DISCHARGE GAS TEMP. SENSOR Fig. 27 Electric Wiring of the Outdoor Unit(MAC18036/MAC18042) 19

Fig. 28 Electric Wiring of the Outdoor Unit(MAC18048) 5.3.8 Start-Up CAUTION UNIT OPERATION AND SAFETY HAZARD Failure to follow this caution may result in minor personal injury, equipment damage or improper operation. To prevent compressor damage or personal injury, observe the following: Do not overcharge system with refrigerant. Do not operate unit in a vacuum or at negative pressure. Do not disable low pressure switch in scroll compressor applications. Dome temperatures may be hot. In 3 phase applications, incorrect phasing will cause reverse rotation, resulting in elevated noise levels, equalized pressures and reduced current draw. Correct by reversing power connections L1 and L2 on contactor. CAUTION PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. Wear safety glasses, protective clothing, and gloves when handling refrigerant and observe the following: Front seating service valves are equipped with Schrader valves. 20

CAUTION ENVIRONMENTAL HAZARD Failure to follow this caution may result in environmental damage. Federal regulations require that you do not vent refrigerant to the atmosphere. Recover during system repair or final unit disposal. Follow these steps to properly start up system: 1. After system is evacuated, fully open liquid and vapor service valves. 2. Unit is shipped with valve stem(s) closed and caps installed. Replace stem caps after system is opened to refrigerant flow (back seated). Replace caps finger tight and tighten with wrench an additional 1/12 turn. 3. Close electrical disconnects to energize system. 4. Set room thermostat at desired temperature. Be sure set point is below indoor ambient temperature. 5. Set room thermostat to HEAT or COOL and fan control to ON or AUTO mode, as desired. Operate unit for 15 minutes. Check system refrigerant charge. 5.3.9 Final Checks IMPORTANT: Before leaving job, be sure to do the following: 1. Ensure that all wiring is routed away from tubing and sheet metal edges to prevent rub-- through or wire pinching. Unitary Ducted Split AC 15. 2. Ensure that all wiring and tubing is secure in unit before adding panels and covers. Securely fasten all panels and covers. 3. Tighten service valve stem caps to 1/12--turn past finger tight. 4. Leave Users Manual with owner. Explain system operation and periodic maintenance requirements outlined in manual. 5. Fill out Dealer Installation Checklist and place in customer file. CARE AND MAINTENANCE For continuing high performance and to minimize possible equipment failure, periodic maintenance must be performed on this equipment. Frequency of maintenance may vary depending upon geographic areas, such as coastal applications. 21