Petrolux III PW Series Wet Locations
HOLOPHANE Wet Location RELIABILITY AND PERFORMANCE ARE KEY CONCERNS IN ALL DEMANDING APPLICATIONS. THE HOLOPHANE WET LOCATION FAMILY OF PRODUCTS IS DESIGNED WITH THE HIGHEST QUALITY MATERIALS TO ENSURE LONG LIFE AND PERFORMANCE IN THE TOUGHEST ENVIRONMENTS. 2 HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III Series
INDOOR LIGHTING Features and Benefits O Superior optical performance for a full range of applications reducing energy costs O Tool-less relamping for ease of maintenance O Rugged, robust construction and mechanical features provides longevity O Perfect choice for wet locations O Unique mechanical features that reduce maintenance Typical Applications O Biodiesel and Ethanol Plants O Pulp and Paper Mills O Power Plants O Water and Wastewater Treatment HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III Series 3
HOLOPHANE Robust Housing Stainless Steel Hardware External Capacitor Module Hollow Core Silicone Gasket Captive Optic & Guard Low Profile Tool-less Relamping with bronze wingnut for easy lamp replacement Robust Housing is hinged with integral ballast and made of heavy duty low-copper aluminum to protect against corrosive environments Captive Optic & Guard reduces maintenance and eliminates the loss of the guard components Hollow Core Silicone Gasket prevents any permanent distortion assuring integrity of the ballast housing and optical chamber 4 HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III PW Series for Wet Locations
INDOOR LIGHTING Robust Housing Universal Mount External Capacitor Module Tool-less Relamping Medium ISD SuperGlass Optics Universal Mount accommodates a wall, pendant, ceiling or stanchion mount in one configuration. Broad Optical Distribution Whether lighting a catwalk, perimeter area, indoor processing area, or a mezzanine, Holophane provides a series of products which offer a complete line of optical choices to meet varying design requirements. The heat resistant borosilicate refractors/reflectors are designed to provide symmetric, asymmetric, and long and narrow distributions with timeless durability. High pressure sodium, metal halide, compact fluorescent and induction lamps are available to meet a variety of design needs. External Capacitor Module reduces operating costs by extending the capacitor life up to 4 times as long as when it is mounted inside the electrical housing HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III PW Series for Wet Locations 5
HOLOPHANE Ordering Information Dimensional Details PWS Low Profile PWL Large Maximum Weight: 13.6 kg (30 lb) Listings The fixture shall be UL/CUL 1598 listed for the following ambient temperatures, suitable for wet locations. HID 50-150W HPS up to 60 C 50-150W MH up to 55 C CFL - 55 C QL - 45 C 6635 Maximum Weight: 22.22 kg (49 lbs.) All of above are at 90 C supply wire temperature IP 66 rating with and without capacitor module and with or without wall/stanchion bracket PWM Medium 4521/4525/4526 Maximum Weight: 22.22 kg (49 lbs.) 4541/4545 Maximum Weight: 14.06 kg (31 lbs) Listings The fixture shall be UL/CUL 1598 listed for 40 C ambient suitable for wet locations. It shall be UL 1598A listed for Marine Outside, NEMA Type 4X IP66 6630/FDZ Maximum Weight: 15.42 kg (34 lbs) Listings The fixture shall be UL/CUL 1598 listed for the following ambient temperatures, suitable for wet locations. HID - up to 55 C Electronic HID - 40 C CFL - up to 55 C QL - up to 40 C Incandescent - up to 55 C All of above are at 90 C supply wire temperature IP 66 rating with and without capacitor module and with or without wall/stanchion bracket 6 HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III PW Series for Wet Locations
INDOOR LIGHTING Preferred Selections: Most Frequently Ordered Catalog Numbers Large version is coming in late 2009 Product ordering data is subject to change when it is available to order PWM 1 LUMINAIRE PWL PWM PWS 175 2 WATTAGE 042 100 175 PM 3 SOURCE CF HP PM C 4 BALLAST C E I P GB 5 SOCKET GB MA 6 VOLTAGE MA MB MC MD MT 45F 7 OPTICS 30C 45F 545 541 FDZ UN 8 MOUNTING CE PD ST UN CP 9 OPTIONS CP GD Catalog Numbers for Entire Product Offering (Pricing and lead times may be affected) STEP 1: PWS PWM PWL LUMINAIRE Petrolux III, low profile Petrolux III, medium Petrolux III, large STEP 2: WATTAGE 042 1 42W 050 1 50W 055 1 55W 057 1 57W 070 1 70W 085 3 85W 100 1 100W 150 1 150W 175 1, 3 175W 200 3 200W 250 2, 3 250W 320 2, 3 320W 350 2, 3 350W 400 2, 3 400W 1 Not available with PWL 2 Not available with PWM 3 Not available with PWS STEP 3: SOURCE CF 2 Compact fluorescent HP High pressure sodium IN 1 Incandescent MH Metal halide PM 1 Pulse start metal halide QL 2 Induction 1 Not available with PWS 2 Not available with PWL STEP 4: C E 1 I N 1, 2 P BALLAST TYPE CWA, constant wattage autotransformer Electronic CWI, constant wattage isolated None HPF, high reactance 1 Not available with PWL 2 Not available with PWS STEP 5: SOCKET 4P 2 Compact fluorescent DB 2 Medium base GB 1 Mogul base PC 2 Induction 1 Not available with PWS 2 Not available with PWL STEP 6: VOLTAGE 12 120V 20 208V 24 240V 27 277V 34 347V 48 480V AV Electronic auto sensing (120-277V) Multi-voltage MA Prewired for 120V MB Prewired for 208V MC Prewired for 240V MD Prewired for 277V MT Multi-voltage QV Induction auto sensing (200-277V) Variable-tap VA Prewired for 120V VD Prewired for 277V VF Prewired for 347V VT Vari-tap 120, 277, 347V STEP 7: OPTICS PWS - SMALL 445 4445 refractor, symmetric PWM - MEDIUM 30C 45F 6630, enclosed reflector 4545, forward throw reflector 541 4541, long and narrow refractor 545 4545, symmetric refractor FDZ FDZ enclosed reflector PWL - LARGE 521 4521, long and narrow refractor 525 4525, symmetric refractor 526 4526, asymmetric refractor 635 6635, enclosed reflector STEP 8: MOUNTING CE Ceiling mount GH Gasketed hook PD Pendant ST Stanchion WL Wall mount, 1 NPT UN Universal mount, 1 NPT STEP 9: OPTIONS Factory Installed. See page 9 for a complete list of options and product availability STEP 10: ACCESSORIES Ships Separately. See page 9 for a complete list of accessories and product availability HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III PW Series for Wet Locations 7
HOLOPHANE Performance Specifications Housing All castings shall be low copper aluminum alloy and painted with polyester powder paint. The top cover shall be secured to the ballast housing with stainless steel hardware including a stainless steel insert. All external hardware shall be captive. It shall have passed a 1000 hour salt spray test as specified by ASTM B-117. No water shall enter the fixture when exposed to a solid stream of water as specified by IEC per IP-X6. The luminaire shall have passed a dust chamber test as specified by IEC per IP-6X standards. When the luminaire is opened there shall be no ingress of dust. The luminaire gasketing shall be of a hollow core silicone type tested to withstand the harsh environments. The fixture shall be designed to prevent any permanent distortion of the gasket assuring the sealing integrity of the ballast housing after accelerated aging. Electro-Magnetic Ballast Shall be copper wound, high power factor with a ballast factor of 1.0 per ANSI C82.2, providing 100% wattage to the lamp. Ballast efficiency shall be above 88%. A protected starter for High Pressure Sodium lamps, if specified, shall sense an inoperative lamp and automatically shut down to prevent continuous pulsing and thermal damage to itself and the ballast. Elite Series Electronic HID Ballast The HID electronic ballast shall be provided with integral color coded leads. This electronic ballast shall be multi-voltage capable and shall operate from a nominal voltage range of 208 277 volts AC. The electronic ballast shall have a system efficiency of greater than 88% under full lamp operation. It shall be FCC compliant for EMI/RFI as per parts 18.305 and 18.307. Total harmonic current distortion shall be less than 15%. Starting input current shall be less than stabilized lamp operating current. The ballast system shall be capable of maintaining stabilized lamp operation through one full cycle of power interruption. Electrical system shall withstand transient peaks of seven strikes of 100kHz ring waves at 2.5kV level for both common and differential mode per IEEE C62.41. External Capacitor Module The luminaire shall include an aluminum casting enclosure adjacent to the main electrical enclosure which houses the capacitor. The external capacitor enclosure shall meet Type 4X enclosure requirements and pass IP66 ingression protection. Universal Mount Luminaire shall provide single mounting option which allows for pendant, wall or stanchion mountings when used in conjunction with universal arm accessory. All enclosures shall be Type 4X approved and provide IP66 ingress protection. Optics P3S Low Profile The refractor shall be made of Endural prismatic borosilicate glass and shall be 8 diameter by 6.5 deep with precisely formed prisms providing a symmetric light distribution. The optical assembly, when secured to the electrical housing, shall provide a totally enclosed and gasketed luminaire. The cast aluminum wireguard, when specified, shall be captive to the optical assembly making it unnecessary to remove during relamping. P3M Medium The 30C reflector shall be made of Endural prismatic borosilicate glass with an aluminum cover. The reflector shall utilize a 3/16 tempered glass roundel secured to the reflector by the aluminum cover. The optical assembly, when fully threaded onto the ballast housing, shall provide a totally enclosed and gasketed luminaire. The FDZ reflector shall be made of acrylic bottom with a spun aluminum cover. The optical assembly, when fully threaded on the ballast housing, shall provide a totally enclosed and gasketed luminaire. The refractors shall be made of Endural prismatic borosilicate glass and shall be 9.5 diameter by 9.5 deep with precisely formed prisms providing a (long and narrow, asymmetric or symmetric) light distribution. The optical assembly, when threaded to the electrical housing, shall provide a totally enclosed and gasketed luminaire. The cast aluminum wireguard, when specified, shall be captive to the optical assembly making it unnecessary to remove during relamping. P3L Large The 635 reflector shall be made of Endural prismatic borosilicate glass with an aluminum cover. The reflector shall utilize a 3/16 tempered glass roundel secured to the reflector by the aluminum cover. The optical assembly, when fully threaded onto the ballast housing, shall provide a totally enclosed and gasketed luminaire. The 521, 525, and 526 refractors, when specified, shall be made of Endural prismatic borosilicate glass and shall be 14 diameter by 10.7 deep with precisely formed prisms providing a (long and narrow, asymmetric or symmetric) light distribution. The optical assembly, when threaded to the electrical housing, shall provide a totally enclosed and gasketed luminaire.
INDOOR LIGHTING Options and Accessories Petrolux III Luminaire PWS PWM PWL OPTIONS 03 120V Cord and Daniel Woodhead Watertite plug for wet locations. 3, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order PF also. X = length of cord in feet. 3 is standard 06 208 and 240V Cord and Daniel Woodhead Watertite plug for wet locations. 3, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order PF also. X = length of cord in feet. 3 is standard 10 277V Cord and Daniel Woodhead Watertite plug for wet locations. 3, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order PF also. X = length of cord in feet. 3 is standard CP EG EM ER F1 F2 GD NA NE PR PS SP External capacitor module Ingress/egress marker decal Standby lighting: 120V tungsten halogen bayonet base lamp and lamp socket to provide lighting during times of temporary power interruption until the HID lamp is cool enough to restrike Emergency circuit lighting: 120V tungsten halogen bayonet base lamp and lamp sockets separate backup (emergency) power circuit that provides sufficient lighting during failure of the normal power supply Single fuse assembly for 12, 24, 27, MA, MC, and MD voltages Double fuse assembly for 20, 24, 48, MB and MC voltages Guard for optics No cord NEMA label Button photocontrol Protected starter for HPS units Sample pack for ground transport ACCESSORIES 09189-* Safety chain kit 445-REPL 541A 545A 30C CDCW-L5-15-X CDCW-L6-15-X CDCW-L7-15-X FDZ F1 F2 LAMP PS-55 PWMGA PWMGC PWSGC WGB WGD P3US Replacement for 445 optical assembly Replacement for long and narrow refractor Replacement for symmetric or forward throw refractor Replacement for 30C reflector 120V Cord and Daniel Woodhead Watertite plug for wet locations. 3, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order PF also. X = length of cord in feet. 3 is standard 208 and 240V Cord and Daniel Woodhead Watertite plug for wet locations. 3, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order PF also. X = length of cord in feet. 3 is standard 277V Cord and Daniel Woodhead Watertite plug for wet locations. 3, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order PF also. X = length of cord in feet. 3 is standard Replacement for FDZ reflector Single fuse assembly for 12, 24, 27, MA, MC, and MD voltages Double fuse assembly for 20, 24, 48, MB and MC voltages Appropriate lamp ships with fixture Protected starter replacement for 15AHPW and below HPS units Optic guard for PWM luminaire with 545, 541 and 45F optics Guard for PWM luminaire with 30C and FDZ optics Guard for PWS luminaire with 445 optics Optic guard for PWL luminaire with 521, 525 and 526 optics Guard for PWL luminaire with 635 optics Universal Mount arm Option - A product option that is factory installed Accessory - A product accessory that ships separately Contact your local Holophane factory sales representative for the most current option and accessory compatibility. Not Available HOLOPHANE DEMANDING ENVIRONMENTS Petrolux III PW Series for Wet Locations 9
Acuity Brands Lighting, Inc. Holophane Headquarters, 3825 Columbus Road, Granville, OH 43023 Holophane Canada, Inc. 9040 Leslie Street, Suite 208, Richmond Hill, ON L4B 3M4 Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, England Holophane, S.A. de C.V., Apartado Postal No. 986, Naucalpan de Juarez, 53000 Edo. de Mexico Contact your local Holophane factory sales representative for application assistance, and computer-aided design and cost studies. For information on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada call 905-707-5830 or fax 905-707-5695. Limited Warranty and Limitation of Liability Refer to the Holophane limited material warranty and limitation of liability on this product, which are published in the Terms and Conditions section of the current Buyers Guide, and is available from your local Holophane sales representative. www.holophane.com/demanding HL-2438 7/09 2009 Acuity Brands Lighting, Inc Luminaires may utilize fluorescent or high intensity discharge sources that contain small amounts of mercury. New disposal labeling for these lamps includes the mercury identifier shown on the left to indicate that the lamp contains mercury and should be disposed of in accordance with local requirements. Information sources regarding lamp recycling and disposal are included on the packaging of most mercury-containing lamps and also can be located at www.lamprecycle.org. Product specifications may change without notice. Please contact your local Holophane factory sales representative for the latest product information. Cert no. SW-COC-002658 Buying products with the FSC label supports the growth of responsible forest management worldwide. The eco savings in the production of this brochure: 2 trees preserved for the future 5 lbs waterborne waste not created 749 gallons wastewater flow saved 83 lbs solid waste not generated 10% 163 lbs net greenhouse gases prevented 1,249,500 BTUs energy not consumed Printed in USA