P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

Similar documents
INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL

ASX7-4-IOM-6 J

INSTALLATION INSTRUCTIONS

ASX7-5-IOM-3 J

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

MACH GAS-FIRED BOILER CM300/CM399/CM500 With ENVI Control

Do not use this vent pipe or fittings for venting incinerators of any kind.

Vent Supplement Ultra-80, -105, -155, -230 & -310

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Revised January 17, 2017

MACH GAS-FIRED BOILER C300-C450 with ENVI Control

User s Information Manual

MACH GAS-FIRED BOILER C1500 & C2000

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Detroit Radiant Products Co.

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL

ENVI Boiler Controller

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Detroit Radiant Products Co.

Power-Fin 4:1 HOT WATER HEATING BOILERS DOMESTIC HOT WATER SUPPLY BOILERS 1,500,000, 1,700,000 and 2,000,000 Btu/hr MODELS

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

SCS SCS

OR Replacement Instructions Heat Exchanger Assembly, ASME

Fig. 1 - Unit PGD4, PGS4, WPG4

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Installation Instructions

Fig. 1 - Unit PHD4 and WPH4

USER'S INFORMATION MANUAL

Owner s Information Manual

Revised January 17, 2017

GB162 Concentric Horizontal Vent Kit

USER'S INFORMATION MANUAL

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Owner s Information Manual

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Prestige Gas Vent Stainless Termination Kit

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

USER'S INFORMATION MANUAL

DOMESTIC WATER HEATER OIL FIRED

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

User s Information Manual

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Ti/Lx 150 ASME HX ASSEMBLY

INSTALLATION AND SERVICE MANUAL

USER'S INFORMATION MANUAL

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

User s Information Manual

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Residential Gas Hybrid Water Heater

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Heat Exchanger Block Replacement Instructions

CLe-series Dishwashers

User s Information Manual Models: 45, ,000 Btu/hr

Installation Instructions

Installation Instructions Part No

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

VENTING APPLICATION GUIDE

EL195DFE SERIES GAS FURNACE WARNING

BlueHeat AirTop 2000 Heater

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Universal Fire Tube Boiler Wall Mount Models

Installation Instruction

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Installation & Maintenance Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation and Operation Instructions Manual

OPTION CA1, CA2, AND CA3 POWER VENTERS

User s Information Manual

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

EUTECTIC EC-10DV Series

Installation Electric Dryers Instructions 01

EL195UH SERIES GAS FURNACE WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

USER'S INFORMATION MANUAL

INSTALLATION AND SERVICE MANUAL

User s Information Manual

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Installation Instructions

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

INSTALLATION INSTRUCTIONS G2D93CT, G2D93CU, G2D95CT, & G2D95CU High Efficiency Multiposition Gas Furnace with System Sentry Control System WARNING

Transcription:

P-K MACH C1500H-C2000H Outdoor Boiler Kit Rev. 1.0 (08/7/2012) 1004905966 P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE This manual is to be used in conjunction with the P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition). C.S.A Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam and Hot Water Boilers ASME Code, Section IV Certified by Harsco Industrial, Patterson-Kelley C.S.A Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam and Hot Water Boilers Model #: Serial #: Installation Date: Harsco Industrial, Patterson-Kelley 155 Burson Street, East Stroudsburg, PA 18301 Telephone: 570.476.7261 Toll Free: 877.728.5351 Facsimile: 570.476.7247 www.harscopk.com 2012 Harsco Corporation Printed: 3/7/2014

Table of Contents P-K MACH C1500H-C2000H Outdoor Boiler Kit 1.0 INTRODUCTION... 5 1.1 COMPLETED P-K MACH C1500H/C2000H OUTDOOR BOILER KIT... 5 2.0 INSTALLATION... 6 2.1 REQUIRED TOOLS AND PARTS... 6 2.1.1 Tools... 6 2.1.2 Parts... 6 2.2 AIR INLET BOX COVER INSTALLATION... 7 2.3 EXHAUST VENT SYTSTEM INSTALLATION... 8 2.4 ELECTRICAL CONNECTIONS... 10 3.0 MAINTENANCE... 11 4.0 ASSEMBLY DRAWINGS... 12 4.1 ASSEMBLY DRAWING C1500H/C2000H... 12 2

The information contained in this document is subject to change without notice from Harsco Industrial, Patterson Kelley. The following words are used in this manual to denote the degree of seriousness of the individual hazards. Used to indicate an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme conditions. or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death Used to indicate a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTICE/NOTE - NOTICE is the preferred signal word to address practices not related to personal injury. The safety alert symbol is not used with this signal word. Extensive safety information is contained in the P-K MACH C1500H-C2000H Installation & Owner s Manual (latest edition) as well as warnings, installation requirements and diagrams. 3

The P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition) must be used in conjunction with this manual for safe and proper installation of this boiler. The boiler and these instructions are for outdoor installation. Incorrect installation may result in injury or death. Shut off and lockout / tagout all utilities which may be hazardous, including electricity, gas, water, etc. before installing the P-K MACH Outdoor Boiler kit. Improper use or failure to lockout / tagout hazards may result in injury. The boiler and these instructions are for outdoor installation. Do not install in any enclosure without proper venting. All exhaust venting must be outdoors. All installations of venting systems should be done only by qualified venting systems personnel. Venting must be installed in accordance with vent system manufacturer s installation instructions and this manual. Installing a boiler or vent system using improper installation methods or materials can result in serious injury or death due to fire or asphyxiation from carbon monoxide or other poisonous gases. Breathing exhaust fumes may cause serious personal injury or death. 4

1.0 INTRODUCTION 1.1 COMPLETED P-K MACH C1500H/C2000H OUTDOOR BOILER KIT 5

The completed boiler is shown above. Prior to shipping, the boiler has been modified by the factory in order to function properly outdoors. Special field installation procedures are required to complete the outdoor installation of the boiler. These additional procedures are described in this manual. This manual is a supplement to the P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition). This and all boilers require proper installation, electrical connections, combustion air and flue vent installation, gas piping, water piping, as well as proper startup and service. This boiler can be used indoors with proper venting to outdoors and standard default parameters. Call Harsco Industrial-Patterson-Kelley service technicians for assistance at (570) 476-8695. Be sure to identify your boiler and its specific installation requirements. 2.0 Installation Additional parts are supplied with the boiler requiring installation in the field. Additional outdoor specific customer supplied parts required as well. 2.1 REQUIRED TOOLS AND PARTS 2.1.1 Tools The following tools are required for the completion of the P-K MACH outdoor boiler kit. Screwdriver (slotted) Drill power driver T-30 Torx Bit Driver (2) 7/16 Combination Wrenches Pliers 2.1.2 Parts (Supplied by Harsco Industrial, Patterson-Kelley) BP00000475: Air Intake box back panel cover 8 FT. 1/8 gasket tape 3 Rain Collar (26) Sealing Washer, 5/16 IDX3/4 O.D. (1) Tube Clear RTV Silicone PK Wall Bracket (6) Steel 7/8 O.D. Hole Plug (4) ¼-20 Nuts (4) ¼-20 Hex HD Cap Screw 6

2.2 AIR INTAKE BOX COVER INSTALLATION 1. Remove (14) ¼-20X3/4 Torx Pan Head Screws to remove factory back panel with collar. 2. Install 1/8X3/4 gasket around perimeter of back panel, where back panel with collar was removed. 3. Install Air intake back panel box cover using the (14) ¼-20 screws that were removed. When reinstalling screws, install (14) 5/16 IDX3/4 OD Sealing Washers. While installing air intake back panel, install PK wall mount bracket to top of air intake box, using (2) of the ¼-20 screws at top of box. 4. Remove (12) ¼-20 Screws from back panel and install (12) Sealing Washers on screws and reinstall screws onto back panel. 7

2.3 EXHAUST VENT SYSTEM INSTALLATION The boiler vent should be installed per this manuals instruction. The information contained herein should be used as a guide only and is not intended to be used in lieu of qualified technical expertise. Failure to comply may result in injury or death. See P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition) for additional venting requirements. Do not use CPVC venting. The P-K MACH C1500H/C2000H Outdoor Boiler requires a category IV exhaust. The exhaust vent must extend at least three (3) feet above the air intake or at least two (2) feet above the highest part of any independent structure within ten (10) feet of the vent. Boiler clearance for combustibles / non-combustibles should be maintained per P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition). Recommended Venting Kit Venting Kit C1500H/C2000H P/K Part # 2640000419 Ref. Drawing # 2640000419_2 8

1. Install 10 UCD Adapter until it meets the condensate drain pan (Approx 3.5 ), followed by the 10 88 Degree Elbow. Install (2)10 X36 LG Double Wall Vent Stack. Install 10-8 reducing cap. Fasten stack using 11 Wall Bracket. An alternate 10 rain cap can be supplied in lieu of reducing cap. 2. The Vent should have seals or gaskets present to contain the positive pressure exhaust. These seals must be installed properly. When the vent manufacturer requires the use of a silicone sealant, only an approved high temperature RTV silicone shall be used. 3. Install Rain Collar on boiler water outlet. 9

2.4 ELECTRICAL CONNECTIONS Use water proof conduit and seal tight connectors to the boiler. Electrical access plugs are located on both sides of the boiler for convenience. Before starting the boiler, check to ensure that the proper electrical service is connected to the boiler. Use waterproof conduit & seal tight See P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition) for specific electrical requirements and diagrams. Incorrect electrical connections may result in severe injury or death. 10

3.0 Maintenance The P-K MACH outdoor boiler requires all of the maintenance as described in P-K MACH C1500H-C4000 Installation & Owner s Manual (latest edition) as well as the additional maintenance listed below. These additional maintenance items should be performed monthly. 1) Check for flue gas recirculation into the air inlet. Flue gas recirculation indicates that the vent is not installed properly for local conditions. 2) Check for freezing of the condensate lines. Frozen lines will result in boiler malfunction. Operation of the boiler in cold temperatures may require the use of heat trace lines for the boiler condensate trap, relief valve, and drain. 3) Check for inlet air box, stack and safety relief valve obstructions due to outdoor debris such as but not limited to leaves, insects, snow, branches and other blockages. 11

4.0 Assembly Drawings 4.1 ASSEMBLY DRAWING C1500H/C2000H 12

NOTES: 13