DUCT SMOKE DETECTOR D4120

Similar documents
Duct Smoke Detector - D4120

INSTALLATION INSTRUCTION BOOKLET FOR SMOKE DAMPERS

Installation Instructions

INSTALLATION AND MAINTENANCE

Reshaping Duct Smoke Detection

Life Safety Dampers Selection and Application Manual

Reshaping Duct Smoke Detection

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

Application Data ! WARNING FACTORY INSTALLED SMOKE DETECTORS FOR SMALL AND MEDIUM ROOFTOP UNITS 2TO25TONS TABLE OF CONTENTS PART NUMBERS

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

Installation Instructions

Modular Supply Make-Up Air Unit

MANUAL RESET ALARM RELEASE

DUCTSD Duct Smoke Detector

D2E Duct Smoke Detector

MANUAL RESET ALARM RELEASE

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

FX-PDD Duct Smoke Detector Installation Sheet

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

Indirect Gas-Fired Make-Up Air

You in Control PRODUCT OVERVIEW

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

Fire Alarm System Accessories

SECTION FIRE ALARM SYSTEMS

SECTION AIR DUCT ACCESSORIES

E-PDD Duct Smoke Detector Installation Sheet

SK-Duct Air Duct Smoke Detector

TrueAlarm ES Analog Sensing

Fire Alarm System Accessories

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

PRODUCT OVERVIEW. SL-2000 AT-A-GLANCE MODEL NUMBER: SL-2000-N 4-Wire Ionization Duct Smoke Detector SL-2000-P 4-Wire Photoelectric Duct Smoke Detector

Duct smoke housing, 2-wire D340/D340P

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

D343. Installation Instructions. Air Duct Smoke Housing

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

SMOKE DAMPERS AIRFOIL STAINLESS STEEL

SMOKE DAMPERS SMOKE DAMPERS

BC-R10 Series. Burner Controllers

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

DH400 Air Duct Smoke Detector

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

TrueAlarm Analog Sensing

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

SP-1000X. Panic Device Power Controller Installation Guide. Rev

TS93 EMR WITH SMOKE DETECTOR

FAST Indoor Air INDOOR AIR QUALITY. FAST Parts - International Comfort Products -Lewisburg, TN. Lit. No.: Rev

Tower & Obstruction Lighting Controls

DNRECL Eclipse Duct Smoke Detector

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

TrueAlert Addressable Notification

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Modular Heating & Ventilating Unit Model IGX-HV

INSTALLATION INSTRUCTIONS

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

MANUAL RESET ALARM RELEASE BOX

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

1400 Direct Wire Ionization Smoke Detector

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Specification/ Data Sheet

Wiring Instructions (01-09)

Fire, Smoke, and Combination Fire Smoke Dampers

DNR Duct Smoke Detector

, -9686, -9688, -9755, Duct Detector/Sensor Installation Instructions

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Direct Gas-Fired Make-Up Air

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Series. Access Power Controllers. Installation Guide

Accuracy by Design Products for the HVAC Professional

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

A. This Section includes the following lighting control devices:

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Powers Controls Low Temperature Detection Thermostat

DH500ACDC Intelligent Air Duct Smoke Detector Housing

HS-100 AT-A-GLANCE MODEL NUMBER: HS-100-N 4-Wire Ionization Duct Smoke Detector HS-100-P 4-Wire Photoelectric Duct Smoke Detector

TrueAlarm Smoke Detectors

1022 R/T Remote Monitor

WARNING! Before replacing actuator, damper must be inspected and determined to be fully functional. See NFPA 80 & NFPA 105 below for recommendations.

Installation Guide for models:

TS93 EMF SERIES. INSPK NO Rev.03/10

Multi-Point Peripherals

Transcription:

Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity as to be a serious hazard to life safety unless blowers are shut down and dampers are actuated. The primary purpose of duct smoke detection is to prevent injury, panic, and property damage by reducing the spread (recirculation) of smoke. The detector samples air currents passing through a duct and gives dependable performance for management of smoke and combination fire smoke dampers. Duct smoke detection can also serve to protect the air conditioning system itself from fire and smoke damage. There are several important documents that provide guidance concerning the performance, application and installation of duct detectors: 1) NFPA Standard 90A, Installation of Air Conditioning and Ventilating Systems ) NFPA Standard 9A, Recommended Practice for Smoke Control Systems 3) NFPA Standard 7, National Fire Alarm Code 4) NFPA Standard 101, Life Safety Code ) UL Standard 6A, Standard for Smoke Detectors for Duct Applications 6) System Sensor, Application Guide System Smoke Detectors & Duct Application Smoke Detectors Duct detectors are: NOT a substitute for an open area smoke detector. NOT a substitute for early warning detection, and NOT a replacement for a building s regular fire detection system. Specifications Type: Photoelectric Air duct velocity: 100 to 4000 fpm (. m/s to 0.3 m/s) Operating temperature range: -4 F to 1 F (-0 C to 70 C) Operating humidity range: 0% to 9% R.H. Operation Voltage: 4 VAC/DC or 10 VAC Features Improved cover design isolates the sensor head from the low flow feature for easier maintenance Plug is sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. Up to 0 detectors may be interconnected. Terminal connections are of the strip and clamp method suitable for 1-1 AWG wiring. Easy access test /reset button makes it possible to test the unit with the cover on. The housing provides ample wiring space, 3/4 in. conduit knockout and built-in short circuit protection to prevent damage to sensitive components during installation. DUCT SMOKE DETECTOR D410 Configuration Maximum wall thickness: 6 in. (1mm) on FSD & SSFSD applications (Consult factory for walls greater than 6 in. [1mm]) Actuator Location: Must be right hand drive Must be externally mounted Detector Location: Mounts opposite actuator side Must be external Sampling tubes longer than three feet must be supported on each end. Holes in duct smoke detector sampling tubes must face into the airflow. Availability For use with all FSD, SSFSD, SMD, SSSMD, and CFSD models. Not available on SMDR models. Listings UL 6A Refer to Greenheck Installation Supplement: Part #46313 IOM-Smoke Detector Supplement

Sleeve Length Ordering Options Sleeve Length Height less than in. (63mm): 4 in. (610mm) sleeve (1 in. [31mm] A dimension) (detector mounted parallel to sleeve) Height greater than or equal to in. (63mm): 1 in. (33mm) sleeve (11 in. [79mm] A dimension) (detector mounted perpendicular to sleeve) Figure 1: Label applied to dampers with factory mounted duct smoke detectors. Smoke detector re uires 100 fpm minimum air velocity in duct. or damper activation re uirements when system velocity is less than 00 fpm, the local authority having urisdiction should be consulted. Refer to smoke detector installation instructions and Greenheck IOM - Smoke Detector Supplement S for dampers with factory mounted duct smoke detectors. 46 1 1 in. x 1 1 in. 16 ga. minimum retaining angle Accessory (OCI//TOR) mounted externally on righthand side of damper 1 1 in. x 1 in. 16 ga. minimum retaining angle Duct reakaway Connection (by others) 1 1 in. x 1 1 in. 16 ga. minimum retaining angle Smoke detector mounted externally on left-hand side of damper 1 1 in. x 1 1 in. 16 ga. minimum retaining angle eight less than inches Smoke detector mounted externally on left-hand side of damper ote: All actuators will be externally mounted on the right-hand side of damper eight e ual to or greater than inches Accessory (OCI//TOR) mounted externally on righthand side of damper ote: All actuators will be exter nally mounted on the right-hand side of damper Duct reakaway Connection (by others) 1 in. A dimension 6 in. wall maximum 4 in. sleeve length 3 in. minimum to allow for retaining angle and duct breakaway connection Figure : Smoke detector mounting orientation for dampers less than inches (63mm) in height. Ordering Options Factory Mounted Smoke detector will be wired to a 4 in. x 4 in. (10mm x 10mm) handi-box. The closure device (if or TOR) will also be wired to the handi-box. Dampers provided with the smoke detector option will include single point wiring as standard (includes, OCI, TOR, detectors, and multiple actuators). Shipped Loose Shipped loose smoke detector will only include the detector itself (no mounting hardware or bracket seals). The duct size will have to be specified in order to allocate the appropriate length sampling tube. Adhere to all national and local codes. 11 in. A dimension 6 in. wall maximum 1 in. sleeve length 3 in. minimum to allow for retaining angle and duct breakaway connection Figure 3: Smoke detector mounting orientation for dampers equal to or greater than inches (63mm) in height. IMPORTANT! Dampers ordered with shipped loose smoke detectors will have the standard sleeve length, not a longer sleeve to accommodate the smoke detector installation. If smoke detectors are intended to be field mounted on the damper sleeve, the damper sleeve length and A dimension will need to be manually changed to the requirements indicated under Sleeve Length.

Space Envelopes Dampers Less Than Inches (63mm) In Height Electrical Ratings 3 in. T ypical Actuator (ML series shown; other actuators available) 6 3 4 in. Single Point W iring (Standar d) Smoke detector, actuator, and al l cont ro l options ar e pr ewir ed to junction box at the factor y. Dampers Equal To Or Greater Than Inches (63mm) In Height 3/4 in. (70mm) Typical Actuator (other actuators available) 1 in. (31mm) Electrical Ratings Single Point Wiring (Standard): Smoke detector, actuator, and all control optiong are prewired to junction box at the factory. Power Supply Voltage 0-9 VDC 4 VAC 0-60Hz 10 VAC 0-60 Hz Input Capacitance 70 µf max. 70 µf max. N/A Reset Voltage 3.0 VDC min..0 VAC min 10 VAC min Reset Time 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power Up Time 3 sec. max. 3 sec. max. 3 sec. max. Alarm Response Time 1 sec. 1 sec. 1 sec. Sensitivity Test See detector label See detector label See detector label Current Requirements Max. Standby Current 1 ma 6 ma RMS @ 4 VAC 60 Hz Max. Alarm Current 6 ma 13 ma RMS @ 4 VAC 60 Hz 0 ma@10 VAC 60 Hz 3 ma @ 10 VAC 60 Hz Contact Ratings Alarm Initiation Contacts (SPST):.0A @ 30 VDC (resistive) Alarm Auxiliary Contacts (DPDT): 10A @ 30 VDC (resistive) 10A @ 0 VDC (resistive) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory Contacts (SPDT):.0A @ 30 VDC (resistive)

1 1 1 Fusible Link 4 VAC/VDC SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER. OCI DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A WIRE MARKER (3169). OCI 4 VAC/VDC SWITCH # SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER.

1 1 1 4 VAC/VDC SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER. /OCI DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A WIRE MARKER (3169). 4 VAC/VDC SWITCH # SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER.

1 1 1 TOR DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A WIRE MARKER (3169). TOR 4 VAC/VDC SWITCH # SWITCHING DEVICE (BY OTHERS) BROWN (OVERRIDE) (PRIMARY) SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER. OCI w/ EP Switch DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A WIRE MARKER (3169). OCI 4 VAC/VDC SWITCH # SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER.

1 1 1 W/ EP Switch 4 VAC/VDC SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER. /OCI W/ EP Switch DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A WIRE MARKER (3169). 4 VAC/VDC SWITCH # SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER.

1 TOR w/ EP Switch DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A WIRE MARKER (3169). TOR 4 VAC/VDC SWITCH # SWITCHING DEVICE (BY OTHERS) BROWN (OVERRIDE) (PRIMARY) SECOND THIRD 1. CONDUIT RUNS WHICH EXCEED 7" MUST HAVE GREEN GROUND WIRE.. FLEX CONDUIT MUST BE SECU WITH A CONDUIT CLAMP (496) WITHIN 1" OF CONDUIT TERMINATION AT THE HANDI-BOX OR ACTUATOR. CONDUIT RUNS MUST ALSO BE SECU ALONG SLEEVE AT A MAXIMUM OF 4" ON CENTER. Copyright 009 Greenheck Fan Corporation D410 Smoke Detector Rev. 1 Feb 009