Dual Function SMART VENT. Superior Flood Protection and Natural Air Ventilation SMART VENT - Model:

Similar documents
WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

OPERATOR S MANUAL. For BURLY ATTACHMENTS

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

Horizontal Bottle Cooler Installation and Operation Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Summer/Fall 2013 When the Levee Breaks The Quest for Greener Landscapes

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

Wax Base Heater & Dispenser

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

Installation Instructions / Warranty

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

US 11/2005. Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3. Instruction manual

Installation Instructions

Featuring... ASZ16 UP TO 16 SEER. ASZ16 Heat Pump

Veranda. Vinyl Railing Special Order Catalog. Browse HomeDepot.com and shop anywhere, anytime. Veranda Products. Built by Barrette.

INSTRUCTIONS FOR OPERATION AND CARE XVSGH GRATER/SHREDDER HOUSING AND ATTACHMENTS

INSTALLATION AND OPERATING MANUAL

Industrial Vacuums, Inc

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

INSTALLATION AND OPERATING MANUAL

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.


INSTALLATION AND OPERATING MANUAL

INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve

Installation & Operation Manual Ice Cream Freezers

Installation Instructions / Warranty. PuraVida 15775XX1

ASSUR ANCE plus.

Installation Instructions / Warranty

Installation Instructions

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

SUPERIOR SOFT-TEC NO SALT WATER SOFTENER Installation & Operation Manual

DUST FREE CARBON Whole House Air Purifier

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

USER S OPERATING AND INSTRUCTION MANUAL

Owner s Manual Hydro-X Vacuum Pac

Phoenix AirMAX - Radial Air Mover

INSTRUCTIONS FOR OPERATION AND CARE XVGA GRATER/SHREDDER AND XVSA SLICER ATTACHMENTS

Service Parts, Kits and Accessories


Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

IN020 Rev F Page 1 of 8

Please Read And Save These Instructions.

MUS INSTRUCTION FOR USE NFPA NFPA LADDER STRAP NFPA ESCAPE ANCHOR

AUTOMATIC SWINGING DOOR

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Installation Instructions / Warranty

OWNERS MANUAL. PLEASE READ THIS MANUAL BEFORE OPERATION

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Duct Mount Rotating Drum Humidifier

1 HP Air Mover. Owner s Manual

COVER PLATE GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL

TORRID MARINE YACHT QUALITY Since Owner s Manual

User s Information Guide

Refrigerator Freezer Installation and Operation Manual

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

Model 53 Macerator Pump Installation, Operation, Repair Manual

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

INSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

INSTALLATION AND OPERATING MANUAL

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL

O w n e r s M a n u a l

Zeus Extreme Owner's Manual

Installation & Operation Manual

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Duct Heater Product Catalog

Installation Instructions / Warranty

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Installation Instructions / Warranty. Massaud

SIMPLE INSTALL. RELIABLE FUNCTION GUTTER GUARD

Service & Parts Manual

INSTALLATION AND OPERATING MANUAL

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

DXP-PB-2-8 Manual 8 Par-Bake & Form Dough Press

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

- Oscillating Table Model Fan

Xaact Spot. Xaact Hot Spot

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

AIR CONDITIONER ELECTRONIC CONTROL

Corn Flame Energy Corn Stove Model 3000

Installation Instructions

Transcription:

SMART VENT - Model: 1540-510 Dual Function SMART VENT Superior Flood Protection and Natural Air Ventilation ICC-ES Evaluated and FEMA Accepted Foundation Flood Vents n Potential savings on homeowner s NFIP premiums n Preserves aesthetic beauty of a home by requiring 2/3 less vents n Each vent certified to protect 200 sq. ft. of your home n Code Compliant, FEMA accepted, ICC-ES Evaluated n All Stainless Steel construction meets or exceeds flood and corrosion resistance code requirements n Patented automatic floats release bi-directional flood door n Temperature controlled louvers automatically open in warm weather and close in cold weather One 16 x 8 vent is certified to cover 200 square feet of enclosed area for flood protection and 51 square inches for ventilation Smart Vent models are certified to provide flood protection and ventilation. This model is used for a home with a crawl space or any enclosed area that desires natural air ventilation and flood protection. All stainless steel construction resists weather and pest.

SMART VENT - Model: 1540-510 Model #: 1540-510 Installation Type: Masonry Wall Style: louvered Dimensions: 16 x 8 Rough Opening: 16¼ x 8¼ (one block, or CMU) Finish: Stainless Steel (Standard) Available Powder Coat Colors For Special Order: How it works: Flood Protection: The Smart VENT door is latched closed until flood water enters. Entering flood water lifts the patented internal floats which unlatches and rotates the door open. This allows the flood water to automatically enter and exit through the frame opening, relieving the pressure from your foundation walls. Ventilation: A bimetal coil (like a thermostat, no electricity is needed) automatically opens and closes the ventilation louvers as temperature changes. They will be closed when it is freezing outside and open when it is warm outside to provide natural ventilation. Important note: Smart Vent does not rely on the louvers to let floodwater in and out. Regardless of the louvers position, opened or closed, when floodwater flows into the door, the internal floats release the door to rotate open to relieve the hydrostatic pressure. The louvers and pest screen are rotated out of the path of the floodwater. The temperature-controlled louvers are for ventilation purposes only. White Wheat Gray Black Stainless (standard) 2 x 15 1 4 Optional Accessories: Fire Damper, Interior Trim Flange & Inner Sleeve, Rain Shield Other Models Available: Insulated Flood Vent, Overhead Garage Door Model, Stacked and Quad Configurations, Models for Wood Studded Wall Applications and Pour in Place Buck Systems. There s more online at www.smartvent.com Dealer Locator, Installer Locator, Cad Drawings, Installation Instructions, Technical Specifications, Frequently Asked Questions, Videos, Testimonials, Resource Library Database, Insurance Forms. Rapidly rising floodwater can put extreme pressure on the foundation walls causing improperly vented structures to buckle and collapse. Smart Vents quickly and efficiently equalize the pressure and minimize damage. Foundation Wall Cross-Section: How does one Smart Vent provide so much coverage? 3 x 15 1 4 You may have heard that FEMA requires that flood openings provide one square inch of opening per one square foot of enclosed area, referring to dimensions of the opening in proportion to the space to be vented. This is only partially correct. FEMA s regulations and guidelines do state that a non-engineered flood vent solution must (among other requirements) provide one square inch of opening per square foot of enclosed area to be vented. However; all SMART VENT products are ICC-ES certified engineered openings. They have been designed, engineered, tested, rated, and certified to provide flood relief so efficiently that only one unit is needed for 200 square feet of enclosed area. It would be our pleasure to contact your code official, surveyor, or insurance agent if they require more information.

Insulated Flood Vent - Model: 1540-520 High Efficiency Insulated Flood Vent Superior Automatic Flood Protection ICC-ES Evaluated and FEMA Accepted Foundation Flood Vents n Potential savings on homeowner s NFIP premiums n Preserves aesthetic beauty of a home by requiring 2/3 less vents n Each vent certified to protect 200 sq. ft. of your home n Code Compliant, FEMA accepted, ICC-ES Evaluated n All Stainless Steel construction meets or exceeds flood and corrosion resistance code requirements n Patented automatic floats release bi-directional flood door n Great for conditioned or sealed crawl spaces One 16 x 8 vent is certified to cover 200 square feet of enclosed area for flood protection The insulated flood vent model is certified to provide insulated flood protection only. This model is used for a garage or conditioned space, where flood protection is required but ventilation is NOT desired. The flood door is constructed of solid stainless steel wrapped around an insulating foam core.

Insulated Flood Vent - Model: 1540-520 How it works: Flood Protection: The flood vent door is latched closed until floodwater enters. Entering floodwater lifts the patented internal floats which unlatches and rotates the door open. This allows the flood water to automatically enter and exit through the frame opening, relieving the pressure from your foundation. Model #: 1540-520 Installation Type: Masonry Wall Style: Insulated Dimensions: 16 x 8 Rough Opening: 16¼ x 8¼ (one block, or CMU) Finish: Stainless Steel (Standard) Foundation Wall Cross-Section: 2 x 15 1 4 3 x 15 1 4 Available Powder Coat Colors For Special Order: White Wheat Gray Black Stainless (standard) Optional Accessories: Fire Damper, Interior Trim Flange & Inner Sleeve, Rain Shield Other Models Available: Smart vent Dual Function Ventilating Flood Vent, Overhead Garage Door Model, Stacked and Quad Configurations, Models for Wood Studded Wall Applications and Pour in Place Buck Systems. There s more online at www.smartvent.com Dealer Locator, Installer Locator, Cad Drawings, Installation Instructions, Technical Specifications, Frequently Asked Questions, Videos, Testimonials, Resource Library Database, Insurance Forms. Rapidly rising floodwater can put extreme pressure on the foundation walls causing improperly vented structures to buckle and collapse. Smart Vents quickly and efficiently equalize the pressure and minimize damage. Use Fewer Vents Preserve the aesthetic beauty of a home by requiring 2 3 fewer vents. Each SMART VENT protects 200 sq/ft of enclosed area vs. 60 sq/ft for non-compliant vents. How does one of your vents provide so much coverage? Before After You may have heard that FEMA requires that flood openings provide one square inch of opening per one square foot of enclosed area, referring to dimensions of the opening in proportion to the space to be vented. This is only partially correct. FEMA s regulations and guidelines do state that a non-engineered flood vent solution must (among other requirements) provide one square inch of opening per square foot of enclosed area to be vented. However; all SMART VENT products are ICC-ES certified engineered openings. They have been designed, engineered, tested, rated, and certified to provide flood relief so efficiently that only one unit is needed for 200 square feet of enclosed area. It would be our pleasure to contact your code official, surveyor, or insurance agent if they require more information.

Insulated Flood Vent - Wood Wall Model: 1540-570 Wood Wall Model shown with interior trim flange High Efficiency Insulated Flood Vent Superior Automatic Flood Protection Designed for Installation Between Studs ICC-ES Evaluated and FEMA Accepted Foundation Flood Vents n Potential savings on homeowner s NFIP premiums n Preserves aesthetic beauty of a home by requiring 2/3 less vents n Each vent certified to protect 200 sq. ft. of your home n Code Compliant, FEMA accepted, ICC-ES Evaluated n All Stainless Steel construction meets or exceeds flood and corrosion resistance code requirements n Patented automatic floats release bi-directional flood door One 14 1 2 x 8 1 2 vent is certified to cover 200 square feet of enclosed area for flood protection The Wood Wall Flood Vent is designed to fit between studs spaced on 16 centers. One vent covers 200 square feet of enclosed area, and it is an easy retrofit. This vent only comes in an insulated model.

Insulated Flood Vent - Wood Wall Model: 1540-570 How it works: Flood Protection: The flood vent door is latched closed until flood water enters. Entering flood water lifts the patented internal floats which unlatches and rotates the door open. This allows the flood water to automatically enter and exit through the frame opening, relieving the pressure from your foundation. Model #: 1540-570 Installation Type: Stud Wall Style: Insulated Dimensions: 14½ x 8½ Rough Opening: 14½ 8 ¾ Finish: Stainless Steel (Standard) Exterior Wall Cross-Section: 2 1 2 x 14 3 1 2 x 14 Available Powder Coat Colors For Special Order: White Wheat Gray Black Stainless (standard) Optional Accessories: Fire Damper, Interior Trim Flange Other Models Available: SMART VENT Dual Function Ventilation 16 x 8 Flood Vent, Insulated 16 x 8 Flood Vent, Overhead Garage Door Model, Stacked and Quad Configurations, Models for Wood Studded Wall Applications and Pour in Place Buck Systems. There s more online at www.smartvent.com Dealer Locator, Installer Locator, Cad Drawings, Installation Instructions, Technical Specifications, Frequently Asked Questions, Video, Testimonials, Resource Library Database, Insurance Forms. Rapidly rising floodwater can put extreme pressure on the foundation walls causing improperly vented structures to buckle and collapse. Smart Vents quickly and efficiently equalize the pressure and minimize damage. Use Fewer Vents Preserve the aesthetic beauty of a home by requiring 2 3 fewer vents. Each SMART VENT protects 200 sq/ft of enclosed area vs. 60 sq/ft for non-compliant vents. How does one Smart Vent provide so much coverage? Before After You may have heard that FEMA requires that flood openings provide one square inch of opening per one square foot of enclosed area, referring to dimensions of the opening in proportion to the space to be vented. This is only partially correct. FEMA s regulations and guidelines do state that a non-engineered flood vent solution must (among other requirements) provide one square inch of opening per square foot of enclosed area to be vented. However, all SMART VENT products are certified engineered openings. They have been designed, engineered, tested, rated, and certified to provide flood relief so efficiently that only one unit is needed for 200 square feet of enclosed area. It would be our pleasure to contact your code official, surveyor, or insurance agent if they require more information.

SMART VENT Overhead Door - Model: 1540-514 Insulated Flood Vent - Model: 1540-524, 1540-574 Overhead/Garage Door Flood Vent Dual Function SMART VENT and Insulated Flood Vent ICC-ES Evaluated and FEMA Accepted Foundation Flood Vents n Potential savings on homeowner s NFIP premiums n Preserves aesthetic beauty of a home by requiring 2/3 less vents n Each vent certified to protect 200 sq. ft. of your home n Code Compliant, FEMA accepted, ICC-ES Evaluated n All Stainless Steel construction meets or exceeds flood and corrosion resistance code requirements n Patented automatic floats release bi-directional flood door n Temperature controlled louvers on dual function models automatically open in warm weather and close in cold weather One 16 x 8 vent is certified to cover 200 square feet of enclosed area for flood protection The Overhead Door Model can be installed into a standard garage door, providing 200 square feet of flood protection per vent. A typical garage (less than 600 sq/ft) requires only three vents in total to become compliant with the NFIP requirements and building codes. Two sizes are available depending on the size of the panel.

SMART VENT Overhead Door - Model: 1540-514 Insulated Flood Vent - Model: 1540-524, 1540-574 1540-514 Dual Function SMART VENT Installation Type: Style: Overhead Garage Doors Louvered or Insulated 2 Sizes Available: Dimension: 16 x 8 (1540-514, 1540-524) Rough Opening: 16 x 8 (cut through door) Dimension: 14 ½ x 8 ½ (1540-574) Rough Opening: 14 1 2 x 8 3 4 Finish: 1540-524, 1540-574 Insulated Flood Vent Powder Coated Painted White Available Powder Coat Colors For Special Order: Wheat Gray Black Stainless White Other Models Available: Smart vent Dual Function Ventilating Flood Vent, Insulated FLOOD VENT, Overhead Garage Door Model, Stacked and Quad Configurations, Models for Wood Studded Wall Applications and Pour in Place Buck Systems. There s more online at www.smartvent.com Dealer Locator, Installer Locator, Cad Drawings, Installation Instructions, Technical Specifications, Frequently Asked Questions, Video, Testimonials, Resource Library Database, Insurance Forms. Choose the correct model: Along with the options for size, we also offer two model choices. The first is a dual function model that will give you automatic flood protection along with automatic ventilation. This model only comes in 16 x 8 size. The second is our Insulated model that seals out the cool or warm air, but opens as flood water rises. This model comes in both sizes. Retrofitting Easy installation (all hardware is included) makes this model ideal to retrofit into an existing garage door. A stainless steel frame cleanly installs into the door with only four (supplied) stainless steel screws and nuts. How it works: Flood Protection: The Smart VENT door is latched closed until flood water enters. Entering flood water lifts the patented internal floats which unlatches and rotates the door open. This allows the flood water to automatically enter and exit through the frame opening, relieving the pressure from your foundation walls. Ventilation: A bimetal coil (like a thermostat, no electricity is needed) automatically opens and closes the ventilation louvers as temperature changes. They will be closed when it is freezing outside and open when it is warm outside to provide natural ventilation. 2 x 15 1 4 3 x 15 1 4 Overhead Door Cross-Section: Overhead garage doors require flood protection too. Hydrostatic pressure caused by rapidly rising flood waters can easily destroy the average garage door.

SMART VENT Combination Models Quad Configuration Custom Commercial Application Stacked Model Stacked, Quad and Custom Flood Vents SMART VENT Combination Models Multiply Protection Combination models come standard in a stacked and a quad configuration. Each configuration is available in a dual function (ventilation and flood protection), or insulated (flood protection only) style. Stacked models are twice as efficient as a single unit and are generally used to provide protection in larger dwellings or where adequate wall space is not available. Quad configurations are an excellent solution for larger commercial projects and are not normally used in residential dwellings. Four vents provide 800 square feet of coverage into a single opening. How it works: Flood Protection: The Smart VENT door is latched closed until flood water enters. Entering flood water lifts the patented internal floats which unlatches and rotates the door open. This allows the flood water to automatically enter and exit through the frame opening, relieving the pressure from your foundation walls. Ventilation: On dual function models, a bimetal coil (like a thermostat, no electricity is needed) automatically opens and closes the ventilation louvers as temperature changes. They will be closed when it is cold outside and open when it is warm outside to provide natural ventilation. Important note: Dual Function models do not rely on the louvers to let flood water in and out. Regardless of the louvers position, opened or closed, when flood water flows into the door, the internal floats release the door to rotate open to relieve the hydrostatic pressure. The louvers and pest screen are rotated out of the path of the flood water. The temperature controlled louvers are for ventilation purposes only.

SMART VENT Combination Models Smart Vent Combination Models Smart VENT Models are certified to provide flood protection AND ventilation. These models are used for a home with a crawl space or built on a pony wall that requires seasonal ventilation of the crawl space AND protection from flooding. All stainless steel construction resists weather and pests. Flood Vent Combination Models Flood Vent Models are certified to provide insulated flood protection only. These models are used for a garage or conditioned space, where flood protection is required but ventilation is NOT desired. The flood door is constructed of solid stainless steel wrapped around an insulating foam core. Standard Finish: Stainless Available Powder Coat Colors For Special Order: Model #: 1540-511 Installation Type: Masonry Style: Louvered Dimensions: 16 x 16 Rough Opening: 16¼ x 16 3 8 (two blocks, or CMU) One 16 16 vent certified for 400 sq. ft. of enclosed area for flood, and 102 sq. in. for ventilation Model #: 1540-521 Installation Type: Masonry Style: Insulated Dimensions: 16 x 16 Rough Opening: 16¼ x 16 3 8 (two blocks, or CMU) One 16 16 vent certified for 400 sq. ft. of enclosed area for flood White Wheat Gray Black Model #: 1540-550 Installation Type: Masonry Style: Louvered Dimensions: 32 x 16 Rough Opening: 33 x 16 3 8 (four blocks, or CMU) One 32 x 16 unit certified for 800 sq. ft. of enclosed area for flood, and 204 sq. in. for ventilation Model #: 1540-560 Installation Type: Masonry Style: Insulated Dimensions: 32 x 16 Rough Opening: 33 x 16 3 8 (four blocks, or CMU) One 32 x 16 unit certified for 800 sq. ft. of enclosed area for flood *Some assembly of frames required Optional accessories for all models: Fire Damper, Interior Trim Flange, Inner Sleeve and Pour in Place Buck Kits

SMART VENT Pour-in-Place Vinyl Buck SMART VENT Pour-in-Place Vinyl Buck Vinyl buck insert for poured foundation walls The Smart Vent Pour-in-Place Vinyl Buck is made of high strength PVC. Each wall buck accepts SMART VENT models 1540-510, 1540-511, 1540-550 and FLOOD VENT models 1540-520, 1540-521, 1540-560 flood vents. Fully assembled units are shipped ready to install with a protective film and wood bracing that protects the buck and flood vent when the wall is poured. The Smart Vent Pour-in-Place Vinyl Buck comes in several widths to accommodate most standard wall thicknesses. Smart VENT Vinyl Buck Model # Width Height Depth 1540-805.50 18 5/8 10 5/8 5 1/2 1540-807.25 18 5/8 10 5/8 7 1/4 1540-808N 18 5/8 10 5/8 7 1/2 (Nominal 8) 1540-808F 18 5/8 10 5/8 7 7/8 (Full 8) 1540-809.25 18 5/8 10 5/8 9 1/4 1540-810N 18 5/8 10 5/8 9 1/2 (Nominal 10) 1540-810F 18 5/8 10 5/8 9 7/8 (Full 10) 1540-811.25 18 5/8 10 5/8 11 1/4 1540-812N 18 5/8 10 5/8 11 1/2 (Nominal 12) 1540-812F 18 5/8 10 5/8 11 7/8 (Full 12) Recommended Installation Instructions Step 1: The Smart vent Pour-in-Place Vinyl Buck should be properly located between the masonry wall forms (plum and level) and secured with reversible fastener into the wood nailing blocks. In the event that the fasteners can not be applied through the face of the forms, alternative approved fastening measures should be taken. Step 2: The form cavity is filled with concrete encasing the buck. After the foundation is cured, the forms are stripped, revealing the Masonry Wall Buck. The wood block support system and protective film can be left in place until the foundation is backfilled. Color Options: The Smart vent Pour-in-Place Vinyl Buck is available in white only. Smart vent and Flood Vent inserts are available in a standard stainless steel finish or one of these special order colors: White Wheat Gray Black Stainless (standard)

SMART VENT Pour-in-Place Vinyl Buck Smart VENT STACKED VINYL BUCK Item / Model # Width Height Depth 1540-805.50 (Stack) 18 5/8 19 5 1/2 1540-807.25 (Stack) 18 5/8 19 7 1/4 1540-808N (Stack) 18 5/8 19 7 1/2 (Nominal 8) 1540-808F (Stack) 18 5/8 19 7 7/8 (Full 8) 1540-809.25 (Stack) 18 5/8 19 9 1/4 1540-810N (Stack) 18 5/8 19 9 1/2 (Nominal 10) 1540-810F (Stack) 18 5/8 19 9 7/8 (Full 10) 1540-811.25 (Stack) 18 5/8 19 11 1/4 1540-812N (Stack) 18 5/8 19 11 1/2 (Nominal 12) 1540-812F (Stack) 18 5/8 19 11 7/8 (Full 12) 1540-800-2 (Stack) 18 5/8 19 2 Extension Stacked Model Smart VENT QUAD VINYL BUCK Item / Model # Width Height Depth 1540-805.50 (Quad) 33 3/8 19 5 1/2 1540-807.25 (Quad) 33 3/8 19 7 1/4 1540-808N (Quad) 33 3/8 19 7 1/2 (Nominal 8) 1540-808F (Quad) 33 3/8 19 7 7/8 (Full 8) 1540-809.25 (Quad) 33 3/8 19 9 1/4 1540-810N (Quad) 33 3/8 19 9 1/2 (Nominal 10) 1540-810F (Quad) 33 3/8 19 9 7/8 (Full 10) 1540-811.25 (Quad) 33 3/8 19 11 1/4 1540-812N (Quad) 33 3/8 19 11 1/2 (Nominal 12) 1540-812F (Quad) 33 3/8 19 11 7/8 (Full 12) 1540-800-2 (Quad) 33 3/8 19 2 Extension Shown with wood block support system and protective film. Side View Quad Configuration

SMART VENT Accessories Flood Vent Fire Damper 1 Wood Wall Interior Trim Flange 2 2 The SMART VENT Option and Accessory System Can Accommodate Any Installation Application 1-Fire Damper Interior Trim Flange and Inner Sleeve Kit Smart Vent manufactures two UL-certified Fire Damper models. A masonry installation model (1540-530) and a wood wall installation model (1540-537). These fire dampers are certified to provide two hours of fire resistance. It is intended to be used in a situation in which fire proofing is required on a wall in which flood venting is installed, usually in a garage or vestibule. A fusible link holds a galvanized steel door in place. At 165 F (73.9 C), the link melts to permit the door to drop, blocking the path of the fire. Compatible with Smart VENT and Flood VENT models - The Fire Damper can safely be installed in the same cavity for either of the flood protection models, without interfering in their operation. Trim flange and inner sleeve are required for installation. 2-Interior Trim Flange and Inner Sleeve Kit The Trim Flange unit fits into the rough opening to provide a clean finished look on the interior wall. Trim flanges are available for use with standard masonry flood vents (1540-533) and Smart Vent Wood Wall Models (4 depth 1540-573 and 9 depth 1540-573-9) come standard in white. The stainless steel sleeve lining is available in a 7 inch sleeve that can expand up to 12 inches, and a 10 inch sleeve that can expand up to 15 inches. 3-Rain Shield In areas of severe rain or harsh conditions, the Rain Shield will provide maximum protection for your vent.

MATERIAL REVIEW & MAINTENANCE INSTRUCTIONS Objective: When we set out to design our flood vent products, a comprehensive study was conducted to determine the most important design attributes that would be needed to insure that our customers received the best product available. Because our company started on the shores of the East Coast of New Jersey, everyone placed durability as their number one concern. Durability: After extensive research, including review of many less expensive materials, we choose to make the bulk of the components for our vents from stainless steel. Salt will pit stainless steel unless it is rinsed with water. We recommend that the vent be washed with fresh water twice a year. Any red rust or minor surface pitting can be removed with commercial de-rusting solutions.. The mechanism that operates the automatic louvers on models 1540-510, 1540-511, 1540-514 and 1540-550 is also entirely made from stainless steel, and water rinsing will reduce corrosion and dirt build-up. Prior to final inspection and testing, the louver mechanism is lubricated with a dry film lubricant. This over the counter lubricant should be applied at minimum one time per year, or when needed. Rinse the louver mechanism, let dry, then spray all of the moving parts. Note: Wet lubricants or grease will allow dirt and sand to accumulate on the moving parts. Use only dry film lubricants. The bi-metal coil is made from highly engineered materials. The composite contains a large portion of Nickel and the finished coil is secondarily heat-treated, which forms a protective barrier to protect it from the elements. A squirt of dry film lubricant into the coil chamber during maintenance will extend its life. The floats are manufactured from engineered plastics. An ultra-violet inhibitor was blended into the raw material before molding to insure that the sun does not degrade the functional or dimensional characteristics of the material. Insert a thin blade or a credit card into each side of the vent door s float slot, and the door will easily push open. Rinse the float cavity, then apply a small amount of dry film lubricant on the float, where it contacts the frame. Like any product, the care one gives will determine its life. We have used the best American materials, along with the best engineering and manufacturing professionals to build our products. With just a little care, your vents will function carefree for many years. www.smartvent.com 877-441-8368

ONE YEAR LIMITED WARRANTY LIMITED, NON-PRORATED AND TRANSFERABLE Any and all product(s) as manufactured by Smart VENT are subject to a one year limited warranty in accordance with the following, provided that the products covered by this warranty have been installed in strict accordance with the Smart VENT written installation instructions and in accordance with all local codes and standards. Cleaning and lubrication may be required, and is not covered by this warranty. Smart VENT warrants to the original purchaser or a subsequent owner of the property that parts are free from manufacturing defects for 1 (one) year from the date of purchase. Should any defect occur during the one-year period following the date of purchase, Smart VENT will provide a replacement for that part deemed to be defective (but not including labor costs incurred in removing the part, installing the replacement part, or shipping). In the event of replacement according to the terms of this warranty, the warranty on the replacement part will extend for the balance of the original warranty period, which is in effect at the time the part proves defective. LIMITATIONS Smart VENT shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with painting, misuse, abuse, neglect or improper handling or storage, or installation not in strict adherence to Smart VENT written instructions. Smart VENT reserves the right to discontinue or modify any of its products, including color, and shall not be liable as a result of such discontinuance or modification. If Smart VENT replaces any part under this warranty, it may substitute parts designated by Smart VENT to be of comparable quality or price range in the event the product initially installed has been discontinued or modified. OTHER CONDITIONS THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER ORAL OR WRITTEN WARRANTIES, LIABILITIES OR OBLIGATIONS OF Smart VENT. PERTINENT STATE LAW SHALL CONTROL FOR WHAT PERIOD OF TIME SUBSEQUENT TO SALE A CONSUMER/ HOMEOWNER MAY SEEK A REMEDY PURSUANT TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL Smart VENT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS OR ANY PERSONS THEREIN, RESULTING FROM THE BREACH OF ANY WARRANTY SET FORTH HEREIN. NO REPRESENTATIVE OF Smart VENT OR ITS DISTRIBUTORS OR DEALERS IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY. Lit-006 www.smartvent.com 877-441-8368