VM-3000 Mercury Vapor Monitor

Similar documents
VM-3000 Mercury Vapor Monitor

Mercury Vapor Monitor VM-3000

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

PG 990 Atomic Absorption

Constant climate chamber with humidity

Constant climate chambers

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

stationary dose rate measuring systems

Series 9000 Total Hydrocarbon Analyzer

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

portable gas analyser

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

SEC Signature Process Gas Analyzer

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Gas detection for your safety

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Constant climate chambers

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Specifications Wavelength Range: 190 nm to 800 nm continuous

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Operate the Mutli-Gas Monitor PID

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

PUV, PIR and PFO Series BROCHURE

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Infrared Moisture Balance (FD-660)

Chemistry Instrumental Analysis Lecture 4. Chem 4631

WASTEWATER Online UV%Transmission Analyzer

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Customised HPLC Systems for Highest Performance

SP-3800AA Atomic Absorption Spectrophotometer

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Variable Temperature Options for Optical Experiments

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Parameterisable compact fault annunciator with permanent display

Pressure measuring instruments

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Laboratory Refrigerator/Deep Freezer TC 802

A New Standard of Excellence

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Section PERIMETER SECURITY SYSTEMS

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Specification for On-Line UPS Battery Monitoring and Data Management System

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Certificate: _01 / 29 April 2014

CLEAN-LASERSYSTEME GMBH

Concise catalogue Water-Industry

LaserMethane mini (LMm)

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

YOUR PARTNER IN FIRE & GAS DETECTION

Chromatographic Air circulated Refrigerator, two-door TC 603

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Gas Detection - GD -

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Model KBWF 720 Growth chambers with light and humidity

ProStar 325 UV-Vis Detector

Advanced FireAlarm Panel 1-4Loop

Chlorine gas leak detector

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Dräger Polytron Pulsar 2 Open Path Gas Detector

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Using the MiniRAE 2000 & ppbrae PID

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

ECOSENSORS 2015 PRICE LISTr-2 PORTABLE AND FIXED AMBIENT OZONE SENSORS

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

HSD Dry Cabinet

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Mark 25 Ultrapure Water Conductivity Analyzer

CERTIFICATE of Product Conformity (QAL1 )

Constant climate chambers

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Long Term Storage Cabinet

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

AS950 REFRIGERATED SAMPLERS

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

HSD Dry Cabinet. Outstanding performance

Speed and Frequency Seite 1 von 7

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

CERTIFICATE of Product Conformity (QAL1 )

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Specifications Minimum Typical Maximum Unit

Transcription:

MERCURY INSTRUMENTS ANALYTICAL TECHNOLOGIES VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Portable, integrated battery for 6 hours operation Proven reliable detection method: UV absorption Easy operation Automatic zero adjustment Measuring ranges 0-100 / 0-1000 / 0-2000 µg/m3 High resolution 0.0001 mg/m3 Data logger integrated

Fields of application The VM-3000 Mercury Tracker serves for continous measurement of the mercury concentration in air and other gases in laboratory as well as industry and mobile applications. It has a wide variety of applicationsons: work place monitoring (threshold limit value) exhaust air monitoring in mercury recovery plants emission monitoring in the chemical industry ground air screening of contaminated soil quality control of hydrogen and natural gas detector for laboratory applications Measuring principle The mercury concentration is measured in an optical cell made of fused silica. A maintenance-free membrane pump continuously feeds the sample gas to the optical cell where light absorption measurement takes place at a wavelength of 253.7 nm. This so-called cold vapor atomic absorption spectroscopy (CVAAS) measuring method is extremely sensitive for mercury determination and has been used successfully for many years. In contrast to the occasionally propagated atomic fluorescence spectroscopy (AFS) method it is low in interference and requires neither an amalgamation step nor expensive noble gases as carriers. Referenz-UV-Detektor Thermostatisierung Optische Küvette UV-Quelle (EDL) Strahlteiler Magnetventil Nullgasfilter Partikelfilter Küvettenheizung Long-Life Membrampumpe UV-Detektor Proben-Eingang Proben-Ausgang VM-3000 flow chart Analytical Performance The VM-3000 uses a high-frequency driven electrodeless Hg low pressure (EDL) lamp as UV source. It generates emission lines of an extremely narrow bandwidth which are congruent with the absorption lines of the Hg atoms. Cross-sensitivities are thus minimized. The extremely high stability of the UV source in the VM 3000 is a result of the reference beam feedback control method. Total background noise is less than 0.1 µg/m3. To prevent temperature drift both the lamp unit and the detectors are temperature-stabilized. Because the optical cell is heated the VM-3000 is insensitive to water vapor.

Easy to operate: LabAnalyzer 254, the preferred system for many laboratories world-wide Special Features Metal housing with sturdy handle Option: Rack version with mounting brackets for 19 racks Membrane pump with long service life Input filter with teflon membrane Stable optical bench Factory-calibrated Easy to operate The user controls the VM-3000 by menu-guided inputs via a waterproof membrane keypad. After switchon the light source is stabilized (approx. 1-15 minutes). When the measurement mode is started, a zero adjustment is first carried out automatically. Then the analyzer switches to measurement and continuously indicates the measured mercury concentration of the gas as a numerical value and a graphic bar. The following settings are possible in the parameters menu: duration and repeat interval of the zero adjustment, selection of the concentration unit (µg/m3 or ppb), measuring range (0.1-100, 0-1000, 0-2000 µg/m3), input of three different alarm levels, calculation of a mean value over three freely selectable time intervals, printer activation, and, if required, a sample dilution factor. Display and Output of Measurements The result of the measurement is displayed on an LCD in real time, both numerically and graphically and is output as an electrical signal of 4-20 ma. The device has outputs for alarm, status and measurement values for full integration in plant control systems. The device also has a serial interface (RS 232) for data collection on a PC. Graphical and numerical display of results in realtime

Extensions The VM-3000 Mercury Vapor Monitor is the basic model of our modular system for mercury analytics. An optional reaction unit and activation of the relevant software turn it into a laboratory unit for liquid samples. A gold trap installed upstream allows measurements in the extreme trace range. Multiplexer operation A multiplexer unit can be connected for automatic monitoring of several measurement points. See information in special broschure. Self Diagnosis System If an important component of the VM-3000 malfunctions the user is warned via the display (blinking messages: clean cell, lamp, low battery, alarm) and via output signals. Battery Operation For operation independent from mains power the VM-3000 is also available with a built-in rechargable battery and a charger unit. This option allows mobile battery-powered applications of up to approx. 5 hours. Data Logger Function A data logger function can be integrated into the VM-3000 as an option. Up to 30000 readings can be stored in the data memory. The logging interval can be set from 1-16 seconds revealing a total recording capacity of 4-60 hours. The stored data can be read out with a PC using the serial interface of the VM-3000 according RS232 standard.

VM-3000 Mercury Vapor Monitor Technical Specifications Measuring principle: Wavelength: UV source: Stabilization: Optical cell: Optical cell heating: UV-Absorption 253,7 nm Electrodeless low-pressure mercury lamp reference beam and thermal fused silica (Suprasil), 23 cm long approx. 70 C Measuring range: 1...100µg/m 3 ; 1...1000µg/m 3 ; 1-2000µg/m 3 Sensitivity: 0.1 µg/m 3 Response time: Computation of mean value: Alarm: Status alarms: Control pad: Measurement display: Signal outputs: Pump: Filter: Power supply: Battery operation: Data logger-function: Power consumption: 1 sec autom. via three freely selectable time intervals when concentration is exceeded, 3 levels are programmable measuring cell soiled, battery state, UV source waterproof membrane keypad Graphic display with background lighting 4...20 ma for recorder; RS 232 bidirectional for PC, data logger etc., parallel for printer membrane pump, approx. 2 L / min. optional Flow meter with alarm message PTFE, 1 µ, 47-50 mm diameter 110... 240 V/(50/60 Hz) optional, 12 V batteries integrated, 6 h capacity or external DC Source Up to 30000 readings capacity 40 W Dimensions: 45 x 15 x 35 cm (W x H x D) Weight: approx. 7 kg Specifications subject to change! 2000 Mercury Instruments VM3000 08-2000 Mercury Instruments GmbH Analytical Technologies Liebigstrasse 5 85757 Karlsfeld (Germany) Tel.: +49 (0)8131-50 57 20 Fax: +49 (0)8131-50 57 22 mail@mercury-instruments.de Distributed by: www.mercury-instruments.de