CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

Similar documents
Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Cleaning doors. Good indoor air also means cleanability of ductwork

Smoke extraction duct of sheet steel

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

Smoke extract fan SMHA HATCH

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Declaration of Performance

Declaration of Conformity Declaration of Performance Notes

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Declaration of Performance

F O C U S D O O R C L O S E R S

DECLARATION OF PERFORMANCE

YOUR GUIDE TO UNDERSTANDING CPR

COMMISSION DELEGATED REGULATION (EU)

See product BS EN :2010

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

DECLARATION OF PERFORMANCE. No EN

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN

Smoke Master SMIA Compact pressurisation and smoke exhaust system

DECLARATION OF PERFORMANCE. No EN

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

1. Terms defined in the Construction Products Regulation (CPR)

Guideline Construction Products Regulation (EU) 305/20122

GNB-CPR Position Paper: Issuance of certificates under CPR

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

DECLARATION OF PERFORMANCE

CE marking of noise barriers and foundations

DECLARATION OF PERFORMANCE. No EN

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Technical Bulletin CE marking: from 1st July 2013

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

Guidance Note No 19/1. CE Marking windows and doorsets

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

CONDOR. Supply air ceiling QUICK FACTS

Supply air unit VEKA Installation & Maintenance

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE ref. no

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

Bevent Rasch RABC-VAV. - Fire /03/2018

EN transition from BS 1387 Structural & Conveyance Business

EU-TYPE EXAMINATION CERTIFICATE

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

COMMISSION DELEGATED REGULATION (EU) /... of

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

Snifter. User Manual. Distributor

The Danish Energy Agency will carry out inspections in June 2013

Snifter ATEX22 VERSION. User Manual. Distributor

Bevent Rasch BSKC6. - Fire /06/17

The Danish Energy Authority to carry out inspections in June and July 2012

CE MARKING OF WOOD-BASED PANELS

Cooling Strip Model SPB

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

TopMaster Air Handling unit. Technical data

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

Construction Products Directive

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Firetect C. Fire protective products: Fire protective board

Primo Hotel. General. Indoor climate units for hotel rooms

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Halton Rex 600 Basic R6B - Active chilled beam

COMMISSION DELEGATED REGULATION (EU) /... of

Circular Fire Damper Cartridge

The New EU-Regulation on Construction Products

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Trade name of the construction product Fix Master Injection system FIT-Ve 200 or FIT-Wi 200 for concrete. Karhutie 9 Fl NURMIJÄRVI FINNLAND

Council of the European Union Brussels, 21 March 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

Implementing the Construction Products Regulation (EU) 305/2011

B COMMISSION REGULATION (EU)

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Council Directive 93/68/EEC of 22 July 1993 amending Directives

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

DECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

Contents. EN :2012 (E) Issue 5 ( ) Page

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

The products covered by the Regulation can be classified as follows:

Transcription:

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

ESAD Smoke Control Duct System INSTALLATION INSTRUCTIONS 1.0 Installation of smoke control ducts, general quidelines Smoke Control Duct ESAD ESAD is CE-marked smoke control duct system for single compartment applications. ESAD duct is fire tested together with fittings and hangers. Smoke control ducts and fittings meet the classification E 120 S, pressure class 1500 Pa. For single compartment applications Sizes 010-100 cm Fire class E 120 S Easy installation To be used together with fire tested VELODUCT fittings 1.5. CE-marking mandatory for smoke control products Smoke control ducts, fittings and other duct components which are used for smoke exhaust purpose, are in scope of the harmonised product standard EN 12101-7 and have to be CE-marked. Please check before starting installation work, that all components are CE-marked. 1.1. Tightness of the duct work Tightness of smoke control duct work is very important. Please follow this installation instruction to be able to get result, which fullfills planned fire class. Please notice, that each joint has to be sealed additionally with aluminium tape, which guarantees tightness also in high temperatures (600 C). Veloduct sealing system together with aluminium tape seals all joints both in normal ambient temperature conditions and in fire situation. 1.2. Duct hangers ESAD smoke control duct hangers are fire tested. Instructions for material for hangers and distances between hangers have to be followed. 1.3. Flexible joint EFLE Duct work shall expand in length in higher temperatures. Flexible joint EFLE shall be used to eliminate these movements. The code is EFLE-aaa-1. Sizes 010-100 cm. 1.4. Veloduct duct fittings and other components Please note, that it is only allowed to use duct fittings and components (IRIS dampers) which are fire tested and CE-marked according to product standard EN 12101-7. Veloduct fittings and components, CE product label 0761 13 0761-CPD-0277 EN 12101-7:2011 Smoke control duct section ESAD Classification E 600 120 h o S 1500 Single ESAD smoke control duct, CE product label ESAD smoke control ducts are marked with CE product label and with longitudinal orange colour CE-marking text printed on the duct. The markings prove to the building owner that these products meet product standard demands for smoke control purposes for Single Compartment Applications. Fläkt Woods EN 2013.08 2 All rights reserved.

ESAD Smoke Control Duct System INSTALLATION INSTRUCTIONS 2.0 INSTALLATION INSTRUCTIONS 2.1. Select a suitable section of ducting and check that the duct can be installed in accordance with the drawing before collecting the necessary components from the storage area. Locate the screws / pop rivets at such a distance from the duct end that the rubber seal will not be damaged. Check the maximal distance K from table 2. 2.2. Collect the necessary fittings and ducts. Check that all parts are CE-marked. Check also that they aren t damaged in any way that would cause air leakage in the finished ducting system. 2.3. Cut the ducts with straight lines to the measured lengths. Deburr the duct ends thoroughly, using a deburring tool. Duct size (cm) Li (mm) K max (mm) 010...020 35 12 025...031 40 15 040...063 60 30 080...100 100 40 Table 2. 2.5. Finally tape all joints carefully with aluminium tape, which has aluminium foil thickness at the minimum 30 μm and the width at the minimum of 50 mm. Type example Advance Tapes AT502. Lock the end of aluminium taping with screws or pop rivets. 2.4. Assemble suitable sections on the floor. To facilitate the fitting of one part into another, turn part while pushing it in. Lock the joints. All joints must be secured by means of pressure proof steel pop rivets or screws (min Ø 4,2 mm). The number of screws / pop rivets are specified in table 1. Duct size (cm) Number of screws / pop rivets 010...016 3 020...031 5 040...063 10 080...100 16 Table 1. Fläkt Woods EN 2013.08 3 All rights reserved.

ESAD Smoke Control Duct System INSTALLATION INSTRUCTIONS Table 3. Duct size (cm) Max distance between hangers L (m) Treaded rod (mm) 010 2 8 012 2 8 016 2 8 020 2 8 025 2 8 031 2 8 040 2 10 050 2 10 063 2 10 080 2 10 100 2 10 2.6. Duct hangers shall be installed not exceeding the maximum distances according to Table 3. Threaded rod strength class shall be 8.8 and diameter according to Table 3. Specified dimensions of duct fasteners have to be used for suspending the duct sections. Duct fasteners have to be made of galvanised steel, minimum thickness of 1,5 mm and width of 25 mm. Type example MÜPRO duct fastener with or without vibration control. See picture below. Suspending solution for the ESAD duct sections is based on results of official fire tests according to product standard EN 12101-7 for Single Compartment Applications. Fire class for ESAD and fittings and other components is E 120 S. Fire test temperature is 600 C. Duct fasteners with hangers should be placed always close to joints, if possible. 3.0 INSPECTION AND MAINTENANCE After installation, when the system is running, it is recommended according to product standard EN 12101-7 that the following inspection procedure is carried out and recorded. These inspections should be undertaken at least once per year. See example of inspection record below. Ducts, fasteners, hangers and fittings are constructed of galvanised steel material for longer operating life. Inspections of sealings have to be made at least once per year. Special notice should be taken to inspect the condition of aluminium taping, which guarantees the tightness in higher temperatures. If any failure is detected, reparation work has to be done immediately. Duct section reference Date of inspection Check ducting for damage Check connections between duct sections and ancillary components Check penetration seals at compartment boundaries Check duct cleanliness and clean where necessary Check the condition of seals, rectify and report where necessary Confirm that the duct fulfils its function as part of the smoke control system NOTE: A smoke control duct section is inherently part of a smoke control system. As this is the case the whole system should be checked as governed by the operation and maintenance requirements for the system. Example of inspection record. Fläkt Woods EN 2013.08 4 All rights reserved.

DECLARATION OF PERFORMANCE No. 006CPR2013-07-01 1. Unique identification code of the product-type: Smoke Control Duct ESAD 2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): Smoke Control Duct ESAD-a-bbb Smoke Control Duct Fittings and Components, annex 1 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: Smoke control duct sections that are to be used in smoke control systems, either at 600 C or under fire conditions 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11(5): Fläkt Woods Oy, Kalevantie 39, 20520 Turku, Finland Tel. +358204423000, Fax: +358204423022, Email: info.fi@flaktwoods.com 5. System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V: System 1 6. MPA Braunschweig, Germany, Nr. 0761 Performed determination the product type on the basis of type testing; initial inspection of the manufacturing plant and of factory production control; continuous surveillance, assessment and evaluation of the factory production control (FPC) under system 1 and issued: certificate of constancy of performance - EC Certificate of Conformity 0761- CPD-0277. 7. Declared performance: Essential characteristics Performance Harmonized technical specification Fire resistance: Single Compartment installations 1500 Pa pressure level 3 integrity E 600 120 insulation EN 12101 7:2011 smoke leakage E 600 120 S mechanical stability (under E) Pass maintenance of the cross section (under E) Pass 8. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 7. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by: Jari Hokkanen, R&D Manager Turku 1.7.2013......

Declaration of Performance No. 006CPR2013-07-01 - Annex 1 PRODUCT CODE SPECIFICATION FDR-aaaa-bbbb-cccc Connection piece for ESAS and ETPS-E dampers IRIS-aaaa IRIS damper BDE(O)P-a-bbb-1 Shut-off damper, smoke control duct version BDEB-90-022...125 Bend - 90º (Segment) BDEB-90-010...020 Bend - 90º (Pressed) BDEG-4-bbb Lid BDEG-1-bbb Lid, fit-on BDEN-1-bbb Joint BDEM-1-bbb Joint BDEB-45-bbb Bend - 45º BDEB-30-bbb Bend - 30º BDEB-15-bbb Bend - 15º BDEB-60-bbb Bend - 60º BDET-1-D1-d1 T-piece BDKF-2-D1-d1 Reducer BDKF-4-D1-d1 Reducer BDEA-6-bbb Branch BDEA-5-bbb Branch BDKU-aaa Branch with mesh FND-aaa Grille for ESAR and ETPR dampers FNR-aaaa-bbbb-c-d Grille for ESAS ja ETPS-E dampers BDEC-1-bbb Branch ESAD-A-BBB ESAD smoke control duct EFLE-aaa-1 Flexible connection piece BDED-1-bbb-ccc Reducer BDED-3-bbb-ccc Reducer BDEX-1-bbb-ccc T-pieces and cross BDEA-1-bbb-ccc Branch BDER-aa-bbb-ccc Sound absorber BDKL-1-bbb Cleaning cover

ESAD Smoke Control Duct System INSTALLATION INSTRUCTIONS Fläkt Woods EN 2013.08 7 All rights reserved.

Fläkt Woods Oy Kalevantie 39 FI-20520 TURKU, FINLAND Tel +358 20 442 3000 Fax +358 20 442 3010