BeveLED Cylinder LBRP6 Pendant

Similar documents
USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

BeveLED Cylinder LBRP6 Surface

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

NanoLED NXT Cylinder LNRP3 Surface

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

80 Watts FLANGE FINISH

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

PROJECT INFORMATION FLANGE FINISH

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

OPTIONAL LENS 2 FLANGE FINISH

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

BeveLED 2.1 PROJECT INFORMATION

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT INFORMATION PROJECT

SliverLED Round Downlight, 1 Regress SR11

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

DATE TYPE 40 DELIVERED PERFORMANCE

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

SliverLED Round Adjustable, Wet Location SR21W

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

BeveLED Cylinder LBRP6 Surface

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

1" Regress Trim DELIVERED PERFORMANCE - Downlight

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

Field changeable between Trimmed / Trimless / Millwork

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

Field changeable between Trimmed / Trimless / Millwork

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

True Zero Conceal - Z3SA-C 3 Square Adjustable

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

BeveLED Mini Trimless Acoustical - B3RDP

BeveLED Mini - B3SD 3 Square Downlight

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3RD 3 Round Downlight

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

BeveLED Mini - B3RA 3 Round Adjustable

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Micro Wall Wash Trimless - MWL

IHOL-4DR / IRD400 4 Gravity LED Downlight

PROJECT DATE FLANGE FINISH

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Performance Chart Electrical Data

IHOL-6DR / IRD600 6 Gravity LED Downlight

Performance Chart Electrical Data

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

Performance Chart Electrical Data

Grüv Flare Regressed. Recessed Linear LED

Performance Chart Electrical Data

Grüv Flare Regressed. Recessed Linear LED

Performance Chart Electrical Data

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Hornet HP. Round Glass Downlight

Hornet HP. Square Glass Downlight

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Adjustable C3M

Evoke Square Downlight

Evoke Square Downlight

Evoke Round Adjustable C3

Hornet HP. Semi-Recessed 4-Light Square Multiple

Evoke 2.9" HP. 2.9" Square Downlight

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Evoke Square Adjustable HP

LIGHT CHANNEL TRIM 1.6

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Velato. Recessed Slot Adjustable Multiples

Transcription:

Beve Cylinder LBRP6 CYLINDER PENDANT BEVE PENDANT WITH CONDUIT CUTOUT SHOWN WITH CROSS BAFFLE usailighting.com/cylinders Power and beauty are both in play with our sleek architectural cylinders. The Beve Cylinder provides industry-leading performance for any ceiling type, with more lumen packages and dimming options than ever before. The full family platform includes a variety of downlight and wallwash distributions, s patented color technologies, and pendant and surface-mount solutions. FEATURES Powerful performance in a full range of lumen packages and beamspreads in a variety of standard or custom colors Rigid pendant stem with 30º hang straight feature and aircraft cable mount options Optional cross baffle extension can be added on for additional glare control Convenient conduit cutout canopy mounting option for attachment to surface-mounted junction boxes and conduit in industrial or exposed concrete ceiling types where recessed wiring is not an option Remote driver options and emergency battery packs for ease of service BEVE CYLINDER DOWNLIGHT PERFORMANCE DATA COLOR CHOICES DELIVERED* PERFORMANCE: Classic White Warm Glow Dimming Color Select Wattage: 9W 12W 16W 24W 33W 36W 16W 32W 16W 32W Source Lumens: 1150 1300 1725 2400 3025 4150 1275 2150 1250 2075 Cylinder Performance Lumens Per Watt: 93 86 86 80 71 0 69 61 66 53 Delivered Lumens: 775 25 1375 1925 2400 3450 10 1850 950 1600 Cross Baffle Performance Lumens Per Watt: 74 73 74 68 60 89 59 53 51 43 Delivered Lumens: 675 875 1175 1625 2050 2950 950 1600 825 1375 *Performance data based on 3000K, 80+ CRI CORRELATED COLOR TEMPERATURE MULTIPLIER CHART Classic White Warm Glow Dimming Color Select 2200K 2700K 3000K 3500K 4000K 2700K 3000K 3500K 2200K 2700K 3000K 3500K 4000K 5000K 6000K Color Rendering Index: 80+ 80+ 90+ 90+ 90+ 80+ 80+ 80+ 90+ 90+ 80+ 80+ 80+ 80+ 80+ 80+ 80+ 80+ 80+ Multiplier for Lumen Output: 0.72 0.94 0.78 1.00 0.80 1.00 1.06 0.93 0.74 1.00 0.80 1.05 0.92 0.97 1.00 1.03 1.05 1. 1.13 Page 1 usailighting.com 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

Beve Cylinder LBRP6 DIMENSIONS RECESSED J-BOX CANOPY RIGID STEM MOUNT (P1, P2, P3) AIRCRAFT CABLE MOUNT (A1, A2, A3) 5" Ø 5" Ø Canopy provided in body finish specified 5/8 Ø Accessory 3/8 finish and length in 1 (6-95 ) FOR USE WITH RECESSED JUNCTION BOXES Canopy provided in body finish specified 3/8 24, 48 or 96 length cable (field cuttable) Power Cable (black or white) Aircraft Cable Suspension Exterior Body Exterior Body Inner Front Cap Inner Front Cap 6" Ø 6" Ø RIGID STEM MOUNT (PJ1, PJ2, PJ3) CONDUIT CUTOUT CANOPY FOR SURFACE MOUNTED J-BOX 5-13/16 Ø 1/2 or 3/4 Conduit (by others) Canopy provided in body finish specified 5/8 Ø Accessory Exterior Body finish and length in 1 (6-95 ) 2-3/8 FOR USE WITH SURFACE MOUNTED JUNCTION BOXES AND CONDUIT 6 Ø Inner Front Cap Page 2 usailighting.com 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

Beve Cylinder LBRP6 with Cross Baffle DIMENSIONS RIGID STEM MOUNT (P1, P2, P3) RECESSED J-BOX CANOPY AIRCRAFT CABLE MOUNT (A1, A2, A3) 5" Ø 5" Ø Canopy provided in body finish specified 5/8 Ø Accessory 3/8 finish and length in 1 (6-95 ) FOR USE WITH RECESSED JUNCTION BOXES Canopy provided in body finish specified 3/8 24, 48 or 96 length cable (field cuttable) Power Cable (black or white) Aircraft Cable Suspension Exterior Body Exterior Body 2 2 Inner Front Cap Inner Front Cap 6" Ø 6" Ø RIGID STEM MOUNT (PJ1, PJ2, PJ3) 5-13/16 Ø CONDUIT CUTOUT CANOPY FOR SURFACE MOUNTED J-BOX 1/2 or 3/4 Conduit (by others) Canopy provided in body finish specified 5/8 Ø Accessory Exterior Body finish and length in 1 (6-95 ) 2-3/8 FOR USE WITH SURFACE MOUNTED JUNCTION BOXES AND CONDUIT 2 Inner Front Cap Page 3 usailighting.com 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

HOW TO SPECIFY Beve Cylinder LBRP6 with Integral Driver Specify fixture part number. All boxes must be filled in to correctly order. INTEGRAL ORDERING INFORMATION LBRP6 Beve Cylinder Wattage Inner Front Cap Optional Cross Baffle Exterior Body Body Length Color Temperature Beam Lens Mounting LBRP6 Beve Cylinder LBRP63 Beve Cylinder Warm Glow LBRP64 Beve Cylinder Color Select Classic White 9009-C3 9W 9012-C3 12W 9016-C3 16W 9024-C3 24W 9033-C3 33W 9036-E1 36W Warm Glow Dimming Color Select 9016-WG2 16W 9032-WG2 32W 9016-CSD1 16W 9032-CSD1 32W White 13 Statuary Bronze 21 Black 28 Metalized Grey SN Satin Nickel Anodized (1) SC Conduit Silver RAL Custom Color F2 2 Cross Baffle Extension (1) (Leave Blank if no Cross Baffle is needed) 1 F2 Cross Baffl e is not available in SN fi nish White 13 Statuary Bronze 21 Black 28 Metalized Grey SN Satin Nickel Anodized SC Conduit Silver RAL Custom Color OAL Classic White 22KS 2200K, 80+ CRI (2) 27KS 2700K, 80+ CRI 27KH 2700K, 90+ CRI 30KS 3000K, 80+ CRI 30KH 3000K, 90+ CRI 35KS 3500K, 80+ CRI 40KS 4000K, 80+ CRI Warm Glow Dimming 2722KS - 2700K-2200K 80+ CRI 2722KH - 2700K-2200K 90+ CRI 3022KS - 3000K-2200K 80+ CRI 3022KH - 3000K-2200K 90+ CRI 3522KS - 3500K-2200K 80+ CRI Color Select 6022KS 6000K-2200K, 80+ CRI Tunable White Light 2 Not available for 36W beam (2) 25 25 beam 50 50 beam 90 90 beam beam 30 30 beam 50 50 beam 90 90 beam 40 40 beam 60 60 beam 80 80 beam SOC Solite Clear (provided standard) SOF Solite Frosted BOF Borosilicate Frosted AS61 Linear Spread Rigid Mount + Conduit Cutout Canopy Style PJ1 6-24 length* PJ2 25-48 length* PJ3 49-95 length* Rigid Mount + Recessed JBox Canopy Style P1 6-24 length* P2 25-48 length* P3 49-95 length* Aircraft Cable Mount + Recessed JBox Canopy Style (field cuttable) A1 24 length A2 48 length A3 96 length *Specify exact stem length in accessory table below INTEGRAL ORDERING INFORMATION (continued) Voltage 120V 277V 120V 347V Dimming Driver usailighting.com For use with 120V or 277V DIML4 Lutron Hi-Lume 1%, 3-wire/ECO (7) DIML4E Lutron 5 ECO, 5% (3) DIML4H Lutron H ECO, 1% Fade (3) DIML6A Eldo 0-V, 0.1% DIML6B Eldo 0-V, 0.1% DIML6E Eldo 0-V, 1% (provided standard) DIML6F Eldo 0-V, 1% DIML7 Eldo DALI, 0.1% For use with 120V only DIML3 Lutron Hi-Lume 1%, 2-wire, 120V only (6) DIML19 Phase dimming 1%, 120V only (2, 3, 4, 5, 6) For use with 347V only DIML15 0-V dim, 1%, 347V only (5, 6, 7) 2 Not available for 36W 5 Not available with Warm Glow 3 Not available for 9W 6 Not available with Color Select 4 Not available for 33W 7 Not available with aircraft cable Color Control 0V 0-V signal transitions color temperature from 6000K to 2200K (8) 8 Required for Color Select only PMB PMB Mount 5/8 Diameter NOTE: Specify for P Rigid Mounting. Accessory not required for A Aircraft Cable Mount PENDANT STEM ACCESSORY - OPTIONAL Type P1 6-24 Lengths P2 25-48 Lengths P3 49-95 Lengths Length XX length from 6-24 in 1 XX length from 25-48 in 1 XX length from 49-95 in 1 Color White 13 Statuary Bronze 21 Black 28 Metalized Grey SN Satin Nickel Anodized SC Conduit Silver RAL Custom Color Page 4 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

HOW TO SPECIFY Beve Cylinder LBRP6 with Remote Driver 1. Specify fixture part number. All boxes must be filled in to correctly order. ORDERING INFORMATION LBRP6 RM Beve Cylinder LBRP6 Beve Cylinder LBRP63 Beve Cylinder Warm Glow Classic White Wattage 9009-C3 9W 9012-C3 12W 9016-C3 16W 9024-C3 24W 9033-C3 33W 9036-E1 36W Warm Glow Dimming 9016-WG2 16W 9032-WG2 32W Inner Front Cap White 13 Statuary Bronze 21 Black 28 Metalized Grey SN Satin Nickel Anodized (1) SC Conduit Silver RAL Custom Color Optional Cross Baffle F2 2 Cross Baffle Extension (1) (Leave Blank if no Cross Baffle is needed) 1 F2 Cross Baffl e is not available in SN finish Exterior Body White 13 Statuary Bronze 21 Black 28 Metalized Grey SN Satin Nickel Anodized SC Conduit Silver RAL Custom Color Body Length OAL Color Temperature Classic White 22KS 2200K, 80+ CRI (2) 27KS 2700K, 80+ CRI 27KH 2700K, 90+ CRI 30KS 3000K, 80+ CRI 30KH 3000K, 90+ CRI 35KS 3500K, 80+ CRI 40KS 4000K, 80+ CRI Warm Glow Dimming 2722KS - 2700K-2200K 80+ CRI 2722KH - 2700K-2200K 90+ CRI 3022KS - 3000K-2200K 80+ CRI 3022KH - 3000K-2200K 90+ CRI 3522KS - 3500K-2200K 80+ CRI 2 Not available for 36W Beam beam (2) 25 25 beam 50 50 beam 90 90 beam beam 30 30 beam 50 50 beam 90 90 beam Lens SOC Solite Clear (provided standard) SOF Solite Frosted BOF Borosilicate Frosted AS61 Linear Spread Mounting Rigid Mount + Conduit Cutout Canopy Style PJ1 6-24 length* PJ2 25-48 length* PJ3 49-95 length* Rigid Mount + Recessed JBox Canopy Style P1 6-24 length* P2 25-48 length* P3 49-95 length* Aircraft Cable Mount + Recessed JBox Canopy Style (field cuttable) A1 24 length A2 48 length A3 96 length Remote Power Supply RM Remote Power Supply (Specify in table below) Power Supply Must Be Specified *Specify exact stem length in accessory table below 2. Specify Remote Power Supply RPC-01 3. Specify Accessory (optional) Remote Power Supply RPC-01 Beve Cylinder Remote Power Supply Wattage 09C3 9W 12C3 12W 16C3 16W 24C3 24W 33C3 33W 36E1 36W 16WG2 16W 32WG2 32W Classic White Warm Glow Voltage UNV 120V - 277V 120V 120V Only Remote Dimming Type and Level D4 Lutron 3-wire/ECO, 1% D4E Lutron 5 ECO, 5% (3) D4H Lutron H ECO, 1% Fade (3) D6A Eldo 0-V, 0.1% D6B Eldo 0-V, 0.1% D6E Eldo 0-V, 1% D6F Eldo 0-V, 1% D7 Eldo DALI, 0% D8 Eldo DMX, 0% (4) D3 Lutron 2-wire, 1% D19 Hatch Phase 2-wire, 1% (2, 3, 4, 5) 2 Not available for 36W 3 Not available for 9W 4 Not available for 33W 5 Not available for Warm Glow Remote Emergency Option EM5 EM battery requires remote enclosure by others, minimum size 11 L x 6.75 W x 3.25 H PMB PMB Mount 5/8 Diameter NOTE: Specify for P Rigid Mounting. Accessory not required for A Aircraft Cable Mount Type P1 6-24 Lengths P2 25-48 Lengths P3 49-95 Lengths Length XX length from 6-24 in 1 XX length from 25-48 in 1 XX length from 49-95 in 1 Color White 13 Statuary Bronze 21 Black 28 Metalized Grey SN Satin Nickel Anodized SC Conduit Silver RAL Custom Color Page 5 usailighting.com 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

HOW TO SPECIFY Beve Cylinder LBRP6 BEVE CYLINDER PENDANT SPECIFICATIONS FIELD REPLACEABLE LIGHT ENGINE Light engine is serviceable without tools. All light engines feature industry-leading color consistency. FIELD REPLACEABLE 0-V, 0%-1% D6E solid state electronic constant current dimming driver with a high power factor provided standard and sources 2mA. Specify 120V or 277V. Driver complies with IEEE C62.41 surge protection. Some on-time delay may be experienced depending on control system used. DIML15 and DIML6 dimming drivers source 2mA. NOTE: D4 is not available with aircraft cable mounting. REMOTE LOCATION If a remote dimming driver is required, specify RM in the fixture part number and proceed to the RP table to complete the dimming driver specification. All remote power supplies must be clearly specified in the RP table, with one remote power supply required per fixture. Remote power supplies require enclosures by others that meet local codes and must be located in an accessible service panel within 0ft of the light fixture; see table below for coordination of enclosure sizes. All dimming drivers comply with IEEE C62.41 surge protection. REMOTE LOCATION EMERGENCY Remote emergency battery IOTA ILB-CP05 provides 5W to one fixture for 90 minutes. Remote power supplies with EM option require an enclosure by others with minimum size of 11 L x 6.75 W x 3.25 H that meets local codes. Emergency battery remote power supplies cannot be located any more than 50 feet from light fixture. BEVE CYLINDER REMOTE POWER SUPPLY REQUIREMENTS AND WIRING DIAGRAM Minimum Enclosure Size Required (by others) Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D4 Lutron 3-wire/ECO, 1% RPC-01-09C3 RPC-01-12C3 RPC-01-16C3 RPC-01-24C3 RPC-01-33C3 RPC-01-36E1 RPC-01-16WG2 RPC-01-32WG2 UNV-D4E Lutron 5 ECO, 5% (2) 14/12 UNV-D4H Lutron H ECO, 1% fade (2) UNV-D6A Eldo 0-V, 0.1% UNV-D6B Eldo 0-V, 0.1% UNV-D6E Eldo 0-V, 1% 18/16 6.25 L x 4 W x 2 H 11 L x 6.75 W x 3.25 H UNV-D6F Eldo 0-V, 1% UNV-D7 Eldo DALI, 0% UNV-D8 Eldo DMX, 0% (3) 120V-D3 Lutron 2-wire phase, 1% 14/12 120V-D19 Hatch 2-wire phase, 1% (1, 2, 3, 4, 5) 14/12 5.75 L X 2.625 W X 2 H 1 Not available for 36W 4 Not available for Warm Glow 2 Not available for 9W 5 Not available for Color Select 3 Not available for 33W * Wire gauge 14/12 = Maximum distance from light fixture to remote power supply is 0 using 12 gauge wire, 50 using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fixture to remote power supply is 0 using 16 gauge wire, 50 using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fixture. HOMERUN USE FOR WIRING WIRING S REQUIRED MDF02M DP02 MDF04M DP04 MDF06M MDF08M DP06 DP08 RP2 RPC REMOTE + POWER - SUPPLY A INPUT WIRES DIMMING COMPATIBILIT ATIBILITY SEE SHEET DIMMING FOR DETAILS COMPATIBILTY SHEETS FOR DETAILS + - BODY 6 Ø extruded aluminum body available in a variety of powder coated paint finishes or an anodized satin nickel finish. Custom colors also available (provide RAL #). FRONT CAP Standard cylinder is provided with snap in diecast 1 regressed bevel assembly in front cap finish specified. If cross baffle option is specified, a 2 extended front cap is provided retaining cast cross baffle; the exterior of the 2 cross baffle extension will be provided in a painted finish matching exterior body finish specification, and the interior cross baffle (including side walls, regressed bevel and cross baffle) will be provided in inner front cap finish specified. Cross Baffle is not available in Satin Nickle finish. Both standard and cross baffle front caps retain a solite glass lens (other lenses optionally available). Page 6 usailighting.com 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

HOW TO SPECIFY Beve Cylinder LBRP6 BEVE CYLINDER PENDANT SPECIFICATIONS (continued) MOUNTING OPTIONS Hardware included for mounting to 4 octagonal junction box. RIGID PENDANT STEM MOUNT 5/8 Ø (3/8 IPS) steel stem is provided cut to length specified with 30 hang straight. finish and length (in 1 increment) in accessories table when ordering; stem is not field cuttable. 5 Ø round x 3/8 deep canopy is provided in finish matching body finish for mounting to recessed mounted junction box. Please contact factory if a different canopy color is desired. AIRCRAFT CABLE MOUNT Length field adjustable 1/16 diameter aircraft cable will be provided in the length specified (select one of three standard lengths on spec sheet). Power to fixture is supplied though ¼ diameter black power cabling, supplied in the matching length. If a white housing is specified, white power cable will be provided. 5 Ø round x 1/4 deep canopy is provided in finish matching body finish specification. Please contact factory if a different power cable and canopy finish is desired. DIML4 is not available with aircraft cable mount. LBRP64 Color Select is not available in aircraft cable mount. RECESSED JBOX CANOPY:If recessed J-box canopy style (P1, P2, P3 or A1, A2, A3) canopy is specified, 5 Ø x 3/8 deep canopy is provided for mounting to recessed mounted junction box. Recessed jbox canopy is provided in matching finish per fixture body finish specification. CONDUIT CUTOUT CANOPY: If PJ canopy is specified, 5-13/16 Ø round x 2-3/8 deep canopy is provided for mounting to standard 4 octagonal surface mounted junction box. Conduit cutout canopy has 4 keyslots, one in each side, and ships with three conduit cutout keys and three solid cover keys which are field interchangeable and can be configured to accommodate any ceiling layout using ½ or ¾ conduit. Conduit cutout canopy is provided in matching finish per fixture body finish specification. CONDUIT CUTOUT MOUNTING EXAMPLE Conduit End Straight Conduit L Conduit T Conduit 4 OCTAGONAL JUNCTION BOX DETAIL 3-1/2 1-1/2 KEY COVER DETAIL SOLID COVER KEY CONDUIT CUTOUT KEY 3-1/2 4 4"Ø X 1-1/2" Deep Octagon J-Box (by others) 3 provided with each Conduit Cutout Canopy 3 provided with each Conduit Cutout Canopy WEIGHT Cylinder weighs 8 lbs (not including rigid pendant stem accessory). WARRANTY Based on IESNA LM80-2008, Beve Cylinder has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. LISTINGS Dry/Damp/Wet for P1, P2, P3 mounting only. All others Dry/Damp. NRTL/CSA-US tested to UL standards. IBEW union made. Energy Star Qualified under Luminaires Specification V2.0. Please see Energy Star website for exact model #s included in the listing. Energy Star qualification requires a white (-) front cap bevel finish and solite clear glass lens. Please note that the following options are not Energy Star qualified: 22KS, 27KH, and 30KH light engines, E1, cross baffle and any non-solite clear lens options. NOTES Ambient temperatures at fixture location should not exceed 40 C during normal operation. For interior use only Consult factory for video capture applications with Warm Glow Dimming or Color Select. PHOTOMETRICS Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. usailighting.com Page 7 2016., LLC. Covered by US Patents: 8,581,520, 8,456,9 and 8,742,695. Patents pending., Beve, Color Select, Color Harmony and Warm Glow are registered trademarks of, LLC. Revised 04/11/2018

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D3 / DIML3 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D3 / DIML3 : Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV 0% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV 0% - 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF2-6ND-120-0% - 1% 1 8 1 4 Lutron Maestro Wireless 00W dimmer MRF2-ND-120-0% - 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 0% - 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD-6ND- 0% - 1% 1 8 1 4 Lutron HomeWorks QS 00 W dimmer HQRD-ND- 0% - 1% 1 13 1 6 Lutron Caseta Wireless Pro 00W dimmer PD-NXD- 0% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 0% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 0% - 1% 1 8 1 4 Lutron RadioRA 2 00 W dimmer RRD-ND- 0% - 1% 1 6 1 3 Lutron myroom DIN power module MQSE-4A1-D 0% - 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-0% - 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE-4A1-D 0% - 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 0% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 0% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-30-, GRX-3500-0% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 0% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 0% - 1% 1 26 1 13 Lutron GP dimming panels Various 0% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 0%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 0%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 0%-1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL-250-0%-1% 1 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT V- GROUND ONLY FOR SWITCHES WITH 2016., LLC. I2-264-3 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D4 / DIML4 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet D20 Dimming module 0% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 0% - 1% 1 53 1 26 Lutron Nova T NTF-- 0% 1% 1 41 1 20 Lutron Nova T NTF-3P- 0% 1% 1 20 1 Lutron Nova NF-- 0% 1% 1 41 1 20 Lutron Nova NF-3P- 0% 1% 1 20 1 Lutron Vareo VF-- 0% 1% 1 20 1 Lutron Skylark SF-P-, SF-3P- 0% 1% 1 20 1 Lutron Diva DVF-3P-, DVSCF-3P- 0% 1% 1 20 1 Lutron Ariadni AYF-3P- 0% 1% 1 20 1 Lutron Vierti VTF-6A- 0% 1% 1 15 1 7 Lutron Maestro MAF-6AM-, MSCF-6AM- 0% 1% 1 15 1 7 Lutron Maestro Wireless MRF2-F6AN-DV- 0% 1% 1 15 1 7 Lutron RadioRA 2 RRD-F6AN-DV- 0% 1% 1 15 1 7 Lutron HomeWorks QS HQRD-F6AN-DV 0% 1% 1 15 1 7 Lutron Interfaces PHPM-3F-120, PHPM-3F-DV 0% 1% 1 41 1 20 Lutron GP Dimming Panels Various 0% 1% 1 41 1 20 277V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet D20 Dimming module 0% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 0% - 1% 1 53 1 26 Lutron Nova T NTF--277-0% 1% 1 44 1 22 Lutron Nova T NTF-3P-277-0% 1% 1 33 1 16 Lutron Nova NF--277-0% 1% 1 44 1 22 Lutron Nova NF-3P-277-0% 1% 1 33 1 16 Lutron Skylark SF-12P-277-, SF-12P-277-3 0% 1% 1 33 1 16 Lutron Diva DVF-3P-277-, DVSCF-3P-277-0% 1% 1 33 1 16 Lutron Ariadni AYF-3P-277-0% 1% 1 44 1 22 Lutron Vierti VTF-6A- 0% 1% 1 33 1 16 Lutron Maestro MAF-6AM-277-, MSCF-6AM-277-0% 1% 1 20 1 Lutron Maestro Wireless MRF2-F6AN-DV- 0% 1% 1 33 1 16 Lutron RadioRA 2 RRD-F6AN-DV- 0% 1% 1 33 1 16 Lutron HomeWorks QS HQRD-F6AN-DV 0% 1% 1 33 1 16 Lutron Interfaces PHPM-3F-DV 0% 1% 1 88 1 44 Lutron GP Dimming Panels Various 0% 1% 1 88 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D4 / DIML4 Continued NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) GROUND DIMMER: 3 WIRE PHASE DIMMED HOT SWITCHED HOT D4 / DIML4 3 WIRE PHASE DIMMING CAP UNUSED ECOSYS WIRES PURPLE GRAY PURPLE ORANGE V- D4 / DIML4 : Lutron Hi-Lume A-Series Driver with EcoSystem Control / Dimming Driver Wiring (Dims down to D4 / DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 0% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 0% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 0% 1% 1 64 1 32 Lutron Quantum Various 0% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. E2 E1 D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 WALL CONTROL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE V- 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING WIRING SCHEMES: D4E / DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 0% 5% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 0% 5% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 0% 5% 1 64 1 32 Lutron Quantum Various 0% 5% 1 64 1 32 DIMMING COMPATIBILITY D4E / DIML4E and D4H /DIML4H NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D4E / DIML4E : Lutron 5 Series EcoSystem Driver / Dimming Driver Wiring (Dims down to 5%) * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4H / DIML4H : Lutron H Series EcoSystem Driver with Fade to Black (dims down to 1%) D4H / DIML4H EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 0% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 0% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 0% 1% 1 64 1 32 Lutron Quantum Various 0% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4E / DIML4E and D4H / DIML 4H EcoSystem CONTROLS E2 E1 ECOSYS BUS E2 E1 WALL CONTROL PURPLE GRAY PURPLE V- 2016., LLC. I2-264-4EH Revised 03/22/2017

DIMMING COMPATIBILITY D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-V control dims from 0% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-V control dims from 0% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN-4T16-S 0% - 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% dimmer. Lutron Interfaces GRX-TVI w/ GRX3503 0% - 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 0% - 0.1% 1% enlighted Control Unit CU-3E-1R 0% - 0.1% 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-lutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-V control dims from 0% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-V control dims from 0% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-1 0% - 0.1% 1% Jung Electronic potentiometer 240-0% - 0.1% 1% Leviton Iluma Tech dimmer IP7-DLX 0% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 0% - 0.1% 1% Merten Electronic potentiometer 5729 0% - 0.1% 1% Pass & Seymour Titan CD4FB-W 0% - 0.1% 1% Watt Stopper Miro DCLV1 0% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 0% - 0.1% 1% ABB i-bus SD/S 2.16.1 0% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 0% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-0% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 0% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 0% - 0.1% 1% Crestron DIN Rail 0-V Fluorescent Dimmer DIN-4DIMFLV4 0% - 0.1% 1% Crestron ilux 0-V Dimmer Expansion Module CLS-EXP-DIMFLV 0% - 0.1% 1% enlighted Control Unit CU-3E-1R 0% - 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. CLASS 2 CONTROL WIRES DIMMER: 0-V RELAY DIMMER: 0-V w/ POWER SWITCHING D6 / DIML6 0-V DIMMING W/RELAY TO SWITCH POWER 0-V (-) 0-V (+) SWITCHED HOT GRAY PURPLE DIML6A, 6B 0-V DIMMING (NO RELAY) V- GROUND DIMMER: 0-V w/ POWER SWITCHING 0-V (-) 0-V (+) SWITCHED HOT D6 / DIML6 0-V DIMMING (NO RELAY) GRAY PURPLE V- 2016., LLC. I2-264-6 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D7 / DIML7 and D7E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 0% to 0.1% D7E = Eldo ECOdrive DALI control dims from 0% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) V- 2016., LLC. I2-264-7 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D8 / DIML8 and D8E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D8 / DIML8 and D8E Dimming Driver Wiring D8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = Eldo POWERdrive DMX control dims from 0% to 0.1% D8E = Eldo POWERdrive DMX control dims from 0% to 1% DMX BUS - XLR CABLE OR SHIELDED DATA CABLE The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 0-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. D8 / DIML8 / D8E DMX CONTROLS DMX BUS - XLR CABLE OR SHIELDED DATA CABLE SHIELD DMX (-) DMX (+) 5 PIN XLR JACKS STANDARD 8 BIT DMX 512 CONTROLLER RED BARE V- 2016., LLC. I2-264-8 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D15 / DIML15 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D15 / DIML15 : 0-V, 347V Dimming Driver Wiring (Dims down to 1%) 347V Only D15 / DIML15 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Output Range Per Dimmer* 347 Use source current per Acuity Synergy ISD-BC 0% - 1% fixture specification Douglas WPN-5721, WPN-5822 0% - 1% sheet to determine Hubbell Light Hawk2 LHD-IRS3-N347-xx 0% - 1% number of fixtures per Leviton Illumatech IP7-DLZ with 347V relay 0% - 1% dimmer. Max number Leviton Centura Fluorescent Control System 0% - 1% of fixtures is limited by Lutron Nova NFTV-* dimmer plus 347V relay 0% - 1% dimmer load rating. Lutron Diva DVTV-* dimmer plus 347V relay 0% - 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D15 / DIML15 0-V DIMMING W/RELAY TO SWITCH POWER DIMMER: 0-V 0-V (-) 0-V (+) SWITCHED HOT GRAY PURPLE V- NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIML2 0-V DIMMING (NO RELAY) GROUND DIMMER: 0-V w/ POWER SWITCHING 0-V (-) 0-V (+) SWITCHED HOT GRAY PURPLE V- NOTE: Quickship fixtures are shipped prewired for 0-V dimming controls. If switched, nondimming operation is desired, cap off purple and gray wires separately at installation. Do NOT cap purple and gray wires together. 2016., LLC. I2-264-15 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D19 / DIML19 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D19 / DIML19 : Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT V- GROUND ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P 2016., LLC. I2-264-19 Revised 03/22/2017