Refrigeration: Reducing energy costs in dairy parlours

Similar documents
Variable Speed Drives: Reducing the energy costs of commercial HVAC systems

Module 2: Farm Practices to Improve Energy Efficiency

Title: Heat Recovery From Milk Cooling Systems

2018 Agricultural Programs Rebate Application Federated Rural Electric, ATTN: Jon, P.O. Box 69, Jackson, MN 56143

Milk cooling systems

Farm Energy Audit Workshop

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

MILK DEVELOPMENT COUNCIL

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Dr. Riaan Rankin & Dr. Martin van Eldik M-Tech Industrial (Pty) Ltd / North-West University October 2010.

Safeguarding quality. Milk cooling solutions for VMS. Your solution every day

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

All products are colour coded for easy identification

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Dairy Housing Milking Centre Design and Construction for Parlour Milking

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Milk cooling systems

COMPANY Presentation Focus on SANDEN Environmental Solutions

PRODUCT DATA SHEETS HEAT PUMPS

SAVNGENERGY. On WA Dairy Farms. DAIRY Saving Energy on WA Dairy Farms 1. Western

Teat Dips / Sprays. Masodine 1:3 Masocare 1:4 Sapphire Masofilm. Parlour circulation cleaners. Crystal Metron Vanorinse Multi Acid

Focus on Energy Business Programs Summary of Services and Incentives July 2009

Price increases since % 38% 53% 63% 115% Ground Beef. Electricity Eggs White Bread

Energy consumption storage facilities examined in ICE-E

Variable Refrigerant Flow (VRF) Systems

Understanding Solar Types

Advanced heat transfer technology

InService Protect your investment

Energy Benefits of Pulsation Stop Control on Dairy Farms

ACMVTECH HIGH EFFICIENCY UNITARY AHU

ODE20: 20 LITRE DEHUIMIDIFIER

Air Conditioning Inspections for Buildings Condensers

Small Business Energy Solutions Agriculture Worksheet

KLDJ : Task 2 Farm Bill Geothermal Heat Pump Template Appendix A. Appendix A Engineering Design

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

The fastest, most hygienic hand dryer.

Contents. General appliance information

Technical description. Atec.

Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy

A heater rated at 1000 watts (1 kilowatt), operating for one hour uses one kilowatt hour (equivalent to 3.6 mega joules) of energy.

Installation, Operation and Maintenance Manual

GEOTHERMAL DESIGN GUIDE

A Cover ENERGY EFFICIENT

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Refrigerated Air Dryers

Energy Saving Fact Sheet Compressed air

Heat Pumps for Swimming Pools extend the season or swim year round

Energy Efficiency Considerations in Refrigeration Systems

HVAC Water chiller selection and optimisation of operation

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

EC Fans Growing in Popularity

The Ed Roberts Campus Berkeley, CA

Peace of milk S M A R T M I L K C O O L I N G

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Energy Recovery Ventilation

FREQUENTLY ASKED QUESTIONS

AIR TO WATER HEAT PUMPS SPECSHEET

Technical Note. EHPA Quality Label Model Range Definition Version

Heat Pump Water Heater Commercial Leaflet 2012

PPL Electric Utilities Energy Efficiency and Conservation Program

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Freedom to choose. DeLaval voluntary milking system VMS

Saving energy comes naturally to us.

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

The Innovation Center for U.S. Dairy and The USDA Natural Resources Conservation Service (NRCS)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Control Strategies and Considerations for Livestock and Other Farm Buildings

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

OIL FREE WATER INJECTED SCREW COMPRESSOR WIS 40-75

LOW TEMPERATURE FREEZER MANAGEMENT GUIDE

System Design, Commissioning, Operation

Cool Savings Program Report

Air-Conditioning Buying Guide

Sustainable Techniques in Refrigerated Space

September 11, 2012 Ministry of Economy, Trade and Industry

* Peak kw is determined by the average kw load reduction occurring between 1PM and 4PM on weekdays during June, July and August.

Energy audit checklist

COMPOST BEDDED PACK BARNS AS A LACTATING COW HOUSING SYSTEM

SWIMMING POOL HEAT PUMPS

Cooling technology. tailored to the needs of modern-day dairy farmers. Packo Inox preserves and protects your milk and your income

Fred Castle Way Rougham Industrial Estate Bury St Edmunds Suffolk IP30 9ND United Kingdom

Reduce everything but reliability

Method to test HVAC equipment at part load conditions

Overview. Heating and Cooling System Strategy

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Energy Saving Fact Sheet Agriculture & Horticulture

Analytical Evaluation of the Energy Losses During the Duty Cycle of a Residential Heat Pump water Heater

Building and Remodeling to Save Energy 1

The Energy Mist System

Efficient Steam System Design

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

25 per cent of energy used in the home is used to heat water.

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

KE2 EvaporatorEfficiency Theory of Operation

Energy Management Wiring Guide

BRITA Vivreau Vi Dispenser

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Transcription:

Refrigeration: Reducing energy costs in dairy parlours Factsheet

Save energy in your milk cooling processes Milk cooling systems account for about 20% of energy used in dairy parlours. Farmers have a few options to improve the efficiency of their refrigeration process. Pre-plate coolers, variable milk pump control, refrigeration heat recovery units and insulated bulk milk tanks can help reduce cooling costs whilst maintaining or even improving the quality of milk. Unpacking the milk cooling process Milk inside a cow s udder has a temperature of about 37 C and drops to about 35 C once it passes through the collector container and piping. It must be cooled quickly to prevent bacteria from affecting its quality. To get milk to the right temperature of 5 C as fast as possible, the cooling equipment includes a pre-cooler and a refrigeration system, which is a bulk milk tank using either a direct expansion refrigeration cycle (Type B tank) or an ice bank (Type A tank). The lower the temperature of the milk when it leaves the pre-cooler, the lower the electricity usage in the refrigeration unit. The energy efficiency of the milk cooling process can be improved in a number of ways

Advantages of a plate pre-cooler Plate pre-coolers, also known as plate heat exchangers, use water to lower the temperature of milk as it flows from the milking system to the bulk milk tanks. Bulk milk tanks are divided into two classes: 1. ED-class is a tank whose content is emptied on a daily basis according to SANS 708-2007 the tank must be able to cool its content from 19 to 5 C in 2,5 hours 2. AD-Class is a tank whose content is emptied every alternative day. According to SANS 708-2007 the tank must be able to cool its content from 12 to 5 C in 2,5 hours. Using cold water from a tap or borehole as a heat exchanging medium to remove heat from the warm milk as it exits a cow s udder, the plate pre-cooler helps to reduce the temperature of the milk before it reaches the bulk milk tank. Increasing the surface area of the heat exchanger by installing additional plates can also help improve the milk s cooling rate and reduce energy usage by the refrigeration unit as the temperature of milk entering the unit will be lower. It is important that plate coolers are properly cleaned and in accordance with HACCP regulations maintained in a hygienic environment to provide efficient cooling and prevent milk from becoming contaminated. With plate pre-coolers, the refrigeration running time can be reduced by 40%. On a farm producing 15,000 litres of milk per day and using an energy-efficient refrigeration unit, each 1 C reduction in the temperature of milk leaving the pre-cooler will save about 860kWh per year. Using a milk pump speed control The pre-cooling process can be improved by installing a Variable Speed Drive (VSD) on the milk pump used to pump milk from the receiving tank inside the parlour to the pre-cooler or bulk milk tanks.

A limit switch inside the receiver tank activates the milk pump when the receiver tank reaches its maximum level and switches the milk pump off when empty this is a continuous process during the milking time. The speed of the milk pump can be reduced, thereby saving energy. During the wash cycle the milk pump will, however, need to run at full speed. VSDs can also be used on the vacuum pump to maintain a constant vacuum and can also be added to the milk refrigeration system to reduce demand during peak times by maintaining the milk s temperature without reducing it. Keeping refrigeration units running efficiently During the milk cooling process, the main electricity user is the bulk milk tank refrigeration unit. Direct expansion is the simplest and most energy-efficient way to cool milk to the required storage temperature. It is a feature of the mechanical refrigeration cycle that heat energy removed from the milk exceeds the electricity required to run the refrigeration unit. The ratio of the energy extracted from the system to the energy used to run the unit is known as the Coefficient Of Performance (COP). The higher the COP, the more energy-efficient the refrigeration system. When running as designed (COP ranging from 2.7 to 2.9), the unit is operating efficiently. If a unit has a lower COP, it is considered inefficient. Possible causes of poor performance include poor installation of refrigerant lines to the bulk milk tank or a faulty refrigeration unit. If the milk cooling time is getting longer and the bulk milk tank refrigeration unit is suspected of poor performance, call a refrigeration serviceman to check the unit. Improvement of the refrigeration system does not require new technology it requires maintenance or improved installation of the current technology. The cooler the condenser and compressor units are running, the better the cooling effect and the lower the energy use. This can be achieved by installing the condenser and compressor units on the southern side of buildings to ensure sufficient ventilation, removal of heat and protection from direct sunlight.

If you are purchasing a new bulk tank or replacing a failed reciprocating compressor, specify that the compressors should be of a scroll type. Scroll compressors are 15 to 20% more efficient than traditional reciprocation compressors, yet they have fewer moving parts and are only slightly more expensive. Scroll or screw compressors can also be fitted with VSDs. Consider using a refrigeration heat recovery unit A refrigeration heat recovery unit transfers excess heat from the condenser of a bulk milk tank to preheat water for use in milking parlours; it can generate approximately one litre of preheated water for every litre of milk cooled. Adding a refrigeration heat recovery unit will help increase refrigeration system efficiency because of the increased capacity to dissipate heat, whilst at the same time capturing heat in water to reduce water heating costs. This is beneficial because water heating can be one of the larger energy uses in a dairy parlour. It is important to note that a pre-cooler will reduce refrigeration needs but also the amount of heat available for preheating water in a refrigeration heat recovery unit. Because of the lower efficiency of water heaters (50 to 85%), it is usually more economical to displace water heating before reducing refrigeration needs with a pre-cooler. In dairies with less than 100 cows, it is usually not economical to use both a pre-cooler and a refrigeration heat recovery unit. Typically, a refrigeration heat recovery unit will provide greater energy and cost savings than a pre-cooler. Dairies with more than 150 cows could benefit from using both technologies. Make maintenance a priority Well maintained refrigeration systems almost always use significantly less energy. Dirty coils or low refrigerant pressures will reduce efficiency and increase operating costs. Make sure you regularly service your refrigeration units, as well as check that condensers are kept clean and fans are working correctly. Dairies could save over 10% of their refrigeration energy costs by implementing some low and no-cost measures including installing good insulation, operating the unit efficiently and implementing an appropriate maintenance schedule.

Conduct an energy assessment Farmers should invest in an energy assessment to determine whether an investment in more energy-efficient refrigeration equipment or other energy-saving technologies offers an acceptable economic payback. Eskom s Energy Advisors are on standby to assist you. Eskom s national Advisory Service offers information on manufacturers and suppliers of energy-efficient electro-technologies. The team can also advise businesses on: Reducing energy usage Doing walk-through energy assessments to identify energy usage patterns, energy needs, areas of energy wastage and energy-saving opportunities Improving the energy efficiency of operations and electrical systems and processes Prioritising maintenance as an important contributor to reducing energy usage Finding SANAS approved energy savings Measurement & Verification Authorities. Advisors can also provide information on funding opportunities for energy efficiency projects. Call 08600 37566, leave your name and number and an Eskom Energy Advisor will contact you, alternatively, ask for a specific advisor to contact you. Visit www.eskom.co.za/idm for more information. Credits: www.carbontrust.com Fanie Steyn, technical paper - Energy savings on motor-driven systems (Johannesburg, South Africa, 2012) Kosie and Manie Eloff, Soekmekaar Farm, Northern Province, South Africa Issued by Eskom Integrated Demand Management October 2015 Eskom Holdings SOC Ltd Reg No 2002/015527/30