REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES

Similar documents
Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

OPERATING INSTRUCTIONS

CC Series VACUUM PUMPS

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.

OPERATING INSTRUCTIONS

ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique

O NEof Premium tools for professionals!

Room Air Conditioner Service and Parts Manual

TECHNICAL & SERVICE MANUAL

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

Refrigeration and AirConditioning Equipment

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTALLATION INSTRUCTIONS

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds.

OWNER S MANUAL (English)

INSTALLATION INSTRUCTIONS

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

REFRIGERANT RECOVERY SYSTEMS

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

OPER LV Wheeler Way

EVac II Programmable Digital Vacuum Gauge

Refrigerant Recovery Unit, Model RRU134

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

for Light Commercial Use

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

OPERATION & MAINTENANCE MANUAL TX600

TRS21 IGNITION PROOF SERIES

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

HERO SERIES-DC INVERTER HEAT PUMPS

R100 Oil-Less Refrigerant Recovery Unit

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

HFO1234 Material. MANIFOLDS: HFO1234 approved MV2HFO set - 2 way Valve deep vacuum manifold way - gauges 80MM HFO carton box 85,26

AIR CONDITIONER CONSOLE

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

TRS21 IGNITION PROOF SERIES

TECHNICAL & SERVICE MANUAL

OWNER S MANUAL (English)

RECOVERY, RECLAIM & DECOMPOSITION OF FLUOROCARBON

Thermo Scientific Air Cadet

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Customized Industrial Products

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds

USER MANUAL UN-200V / UN-200VH

OPERATION & MAINTENANCE MANUAL RHS680

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Refrigerant Recovery/Recharging Series

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

Refrigeration air dryer

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

SECTION 50 - CAB CLIMATE CONTROL

HEATING AND AIR CONDITIONING

Room Air Conditioner Service and Parts Manual

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

[FLARE CONNECTION TYPE] ATTENTION

evac Pro Programmable Digital Vacuum Gauge Operation and Maintenance Manual

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Refrigerant Installation Quick Reference Guide

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

AIR CONDITIONNING 95 CODE 002

Caresaver Universal Refrigerant Recovery Unit

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

OPERATING the HIGH ALTITUDE VACUUM CHAMBER

BAC 4000a BAC 5000yf

Measurement Solutions for Refrigeration Technology.

REFRIGERANT ON-VEHICLE INSPECTION AC 14

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

AIR CONDITIONER FLOOR CEILING

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

INSTALLATION INSTRUCTIONS

Service Parts for RMR Wall-Mount Enclosures

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

Measurement Solutions for Refrigeration Technology.

mn Dometic KRA Refrigeration Price and Parts Guide

SERVICE MANUAL FOR MODEL RM-10

1. General Description

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

Residential Piping and Long Line Guideline

Chemistry diaphragm pumps

Order by phone Order on-line Order by fax Website

Precise Temperature Control; Compact Footprint

Tel: Fax: Website:

Equipment. Application of refrigerants and heat transfer fluids Application of brazing alloys Application of insulation EQUIPMENT

Transcription:

/ ACCESSORIES

High performance Lightest vacuum pump VACUUM PUMP.8CFM Eco Applicable to room air-conditioner, package air conditioner up to 5HP.8CFM Eco Code No.WV0 Suitable for vacuuming small 5HP refrigeration. Code No.WV (0 0V) 3.0Pa abs. ~5HP class 50L/ min Suitable for vacuuming small equipment REFRIGERANT SERVICE TOOLS High precision stage vacuum pump Exhaust Intake pole condenser motors is 5 microns which is the highest level for the small Vacuum Pump. Two rotary pumps are placed in series to get larger compression ratio for lower pressure. (higher vacuum). Enough exhaust speed performance although it is compact designed. Strengthen the capacity under low temperature or voltage Reinforcement of starting and operating efficiency with a new motor when it s under low temperature or voltage. Bult-in metal mesh filter Large diameter exhaust port Reduce oil-mist specific to oil rotary vacuum pumps. Large diameter port for oil charging and exhaust. Pump speed Motor Oil capacity Intake Standard accessorie.8cfm Eco Gauge Kit Code No.WV0CG 60mm L/min (50Hz) 50L/min (60Hz) 3.0Pa abs. (5micron),880min (50Hz) 3,0min (60Hz) Voltage made to order 00W 5.0kg 50ml /", 5/6" (Flare male) oil 0.3L, Adaptor /" female M0 male and ultimate vacuum are according to our own survey. Code No.WVCG (0 0V) 3.0Pa abs. 05mm 00mm ~5HP class 50L/ min The most suitable Vacuum Pump.8CFM Eco Kit with Vacuum Gauge with a valve for vacuum check and Case. Solenoid check valve Prevent vacuum pump oil from flowing backward. Prevent damage to HFC systems by backward flow of oil. With over load protection Protect motor from getting damage by over loading. Cooling fan Send air from back to front to prevent motor and pump from heating up. Radiating fins Enable to run long time. Sight glass Large sight glass for easy monitoring of the oil level and condition. Standard accessorie.8cfmeco, Small vacuum gauge with a valve, Adaptor /" female 5/6" male, Case, oil 0.3L, Adaptor /" M0 male

Applicable to various equipment! Ultra- high - spec models! VACUUM PUMP Eco SERIES Built-in high precision - stage & forced lubrication pump Realize higher vacuum. Improved oil film performance for longer service life. CFM Eco Code No.WV0 Code No.WV (0 0V) Built-in forced lubrication pump prevents the unit from damaging due to insufficient oil volume. Suitable for vacuuming small to 7HP class refrigeration equipment!! ~7HP class 57L/ min Stage Forced Iubrication 30mm Exhaust Intake Two rotary pumps are placed in series to get larger compression ratio for lower pressure. (higher vacuum). Equipped with a pole high torque motor Ultra high performance vacuum pump which can start and run stably even in wintertime or at low voltage by two capacitors for starting and running. (6 8CFM Eco) Equipped with a start capacitor for stable starting even in wintertime or at low voltage. ( CFM Eco).0Pa (5 micron) Realize high vacuum by high precision machining technology. ( 6 8CFM Eco) Oil Intake port Built-in forced lubrication pump prevents vacuum pump from damage due to insufficient oil volume. Bult - in metal mesh filter Reduce oil-mist specific to oil rotary vacuum pumps. Pump speed Motor Oil capacity Intake port 308mm 5L/min (50Hz) 57L/min (60Hz) (5 micron),0min (50Hz),70min (60Hz) Voltage made to order 50W 9.kg 60ml /", 5/6" (male flare) oil 0.35L, Adapter /" female flare M0 male flare and ultimate vacuum are according to our own survery. CFM Eco Gauge Kit Code No.WV0CG mm Code No.WVCG (0 0V) ~7HP class The most suitable Vacuum Pump CFM Eco Kit with Vacuum Gauge with a valve for vacuum check and Case. Large diameter exhaust port Large diameter port for oil charging and exhaust. With over load protection Protect motor from getting damage by over loading. Solenoid check valve Prevent vacuum pump oil from flowing backward. Prevent damage to HFC systems by backward flow of oil. Cooling fan Send air from back to front to prevent motor and pump from heating up. Gas ballast valve High speed evacuation. Keep oil clean during evacuation of wet system. Radiating fins Enable to run long time. Sight glass Large sight glass for easy monitoring of the oil level and condition. CFMEco, Small vacuum gauge with a valve, Adaptor /" female 5/6" male, Case, oil 0.35L, Adaptor /" female M0 male

CFM Eco Code No.WV0 Code No.WV (0 0V) Suitable for vacuuming small to 0HP class refrigeration equipment!! ~0HP class 3L/ min Built-in forced lubrication pump prevents the unit from damaging due to insufficient oil volume. CFM Eco with gauge and carrying case CFM Eco Gauge Kit Code No.WV0CG CFMEco with single vacuum manifold and carrying case. ~ 0HP class Code No.WVCG (0 0V) REFRIGERANT SERVICE TOOLS 65mm 335mm 38mm 00L/min (50Hz) 3L/min (60Hz) (5 micron) Pump speed,0min (50Hz),70min (60Hz) Motor Voltage made to order 375W.kg Oil capacity 390ml Intake port /", 3/8" (male flare) Standard accessories oil 0.35L pcs, Adapter /" female flare 5/6" male flare, Adapter /" female flare M0 male flare and ultimate vacuum are according to our own survery. CFMEco, Single vacuum manifold, Adapter 3/8" female flare /" male flare, oil 0.35L pcs, Adapter /" female flare 5/6"male flare pcs, Adapter /" female flare M0 male flare, Case 6CFM Eco Built-in forced lubrication pump prevents vacuum pump from damaging due to insufficient oil volume. ~30HP class 70L/ min Double capacitor increases startability at low temperature! Suitable for vacuuming small to 0HP class refrigeration equipment!! 8CFM Eco Code No.WV60 Code No.WV6 (0 0V) Code No.WV80 Code No.WV8 (0 0V) Built-in forced lubrication pump prevents vacuum pump from damaging due to insufficient oil volume. ~ 5HP class 6L/ min Double capacitor increases startability at low temperature! Suitable for vacuuming small to 5HP class refrigeration equipment!! 90mm 300mm 390mm 5mm L/min (50Hz) 70L/min (60Hz) (5 micron) Pump speed,0min (50Hz),70min (60Hz) Motor Voltage made to order 550W 6.5kg Oil capacity 580ml Intake port /", 3/8" (male flare) Standard accessories oil 0.35L pcs, Adapter /" female flare 5/6" male flare, Adapter /" female flare M0 male flare and ultimate vacuum are according to our own survery. 98L/min (50Hz) 6L/min (60Hz) (5 micron) Pump speed,0min (50Hz),70min (60Hz) Motor Voltage made to order 550W 7kg Oil capacity 60ml Intake port /", 3/8" (male flare) Standard accessories 395mm oil 0.35L pcs, Adapter /" female flare 5/6" male flare and ultimate vacuum are according to our own survery. 53mm 3

High performance High quality Long life supreme vacuum pump!! VACUUM PUMP SERIES For vacuuming and dry of Auto A/C, large refrigerator, commercial refrigeration system, room A / C, package A/C system CFM Code No.Y9359 For vacuuming of small 0HP class refrigeration equipment. ~0HP class 6L/ min st Stage (Intake) st Stage (Exhaust) High efficient - stage rotary pump For increased efficiency, the first stage exhausts into the second stage similar to using two single stage pumps connected together. YELLOW JACKET s used in all over the world Suitable for long time vacuuming works!! Equipped with a pole high torque motor.0pa (5 micron) 93mm Silent operation. Increase startability at low temperature and low voltage. Realize high vacuum by high precision machining technology. Bult-in check valve Large diameter exhaust port Prevent vacuum pump oil from flowing backward. Prevent damage to HFC systems by backward flow of oil. Large oil drain plug Large oil drain plug with easy access for fast, clean oil changes. With over load protection Protect motor from getting damaged by over loading. Gas ballast valve High speed evacuation. Keep oil clean during evacuation of wet system. Large diameter port for oil charging and exhaust. Buit - in vacuum gauge Check vacuum condition. Radiating fin Enable to run long time. Sight glass Large sight glass for easy monitoring of the oil level and condition. 3mm 56mm 95L/min (50Hz) 6L/min (60Hz) (5 micron) Pump speed,5min (50Hz),75min (60Hz) Motor Voltage made to order 375W 5.kg Oil capacity.08l Intake /", 3/8" (male flare) Adapter /" female flare 5/6" male flare, oil.l and ultimate vacuum are according to our own survery. Prevent oil mist from scattering Oil Exhaust Filter Code No.Y93386 Screws onto pump exhaust to eliminate oil mist. Maintains the environment in the closed space and relives the operator's burden. Applicable to YELLOW JACKET VACUUM PUMP ( 8 6FM) 380g Thread size NH 3/" Suitable model 6 8CFM Replacement Filter Clean vacuuming without oil mist!! Code No. Y93387

6CFM Code No.Y93569 For vacuuming of small to large refrigeration equipment. Abundant product line up suitable for various condition ~30HP class 7L/ min Latest evacuation method & technology Latest technology and high performance vacuuming system realize to increase the benefit. High speed & high vacuum High speed, is more than.0pa of.0pa is enough capacity to eliminate contamination causing trouble on equipment. REFRIGERANT SERVICE TOOLS Abundant product line up brings vaccum pump's ability into full play. 5 Suitble for long time vacuuming and vacuuming from small to 30HP class refrigeration equipment! 3 Vacuum Pump Manifold for Vacuuming 3 Vacuum Guage 3/8" Charging Hose 93mm 5 Quick Charging Valve Pump speed L/min (50Hz) 7L/min (60Hz) (5 micron),5min (50Hz),75min (60Hz) 3mm Motor Voltage made to order 375W 6.kg Oil capacity.0l Intake /", 3/8" (male flare) 56mm Adapter /" female flare 5/6" male flare, oil.l and ultimate vacuum are according to our own survery. 8CFM Code No.Y93589 For vacuuming of small to large refrigeration equipment. Abundant product line up suitable for various condition Abundant product line up brings vaccum pump's ability into full play. ~5HP class 9L/ min Latest evacuation method & technology Latest technology and high performance vacuuming system realize to increase the benefit. High speed & high vacuum High speed, is more than.0pa of.0pa is enough capacity to eliminate contamination causing trouble on equipment. 5 Suitble for long time vacuuming and vacuuming from small to 5HP class refrigeration equipment! 3 3 Vacuum Pump Vacuum Guage Pump speed 90L/min (50Hz) 9L/min (60Hz) (5 micron),5min (50Hz),75min (60Hz) Manifold for Vacuuming 3/8" Charging Hose Quick Charging Valve Motor Voltage made to order 375W 7.0kg 5 mm 93mm Oil capacity.9l Intake /", /" (male flare) Adapter /" female flare 5/6" male flare, Adapter /" female flare 3/8" male flare, oil.l 56mm and ultimate vacuum are according to our own survery. 5

VACUUM PUMP IMPORTANCE OF CHANGING OIL After vacuuming operation, recommend to change oil to new while the oil is still warm to remove pollutants with the oil before they are precipitated. By changing oil regulary and keeping oil clean, prevent deteriorations of performance, efficiency of pump and also the pump unit from being worn and corroded. Worn and corroded pump unit can not be recovered even change its oil. For checking vacuum condition in the system Digital Vacuum Gauge evacⅠ Code No.Y6907 Special vacuum pump oil Vacuum Pump Oil 0.5L : Code No.VP005 0.7L :Code No.Y9309 0.95L :Code No.Y9309 3.80L :Code No.Y9309 0.5L 0.7L 0.95L 3.80L Item Capacity Quantity Vacuum Pump Oil 0.5L 0.7L 0.95L 3.80L Display the vacuum level with numerical value and bar graph. With warning function to protect the sensor from oil. Can proofread manually after measuring. With back light and muffling function. Measuring range Sensor Working temperature Power source For checking vacuum condition in the system Electronic Vacuum Gauge PAT.P Code No.Y69086 Automatic shut-off 3.33 0 3 Pa abs. (5000micron)~0Pa abs. (0micron) Thermistor ~50 C 9V alkaline battery 0.7kg 9V alkaline battery, Adaptor Low battery indicator Automatic ambient temperature compensation. Coilded sensor cord streches to 300~600mm for easy reading. Ideal tool for vacuuming Dispaly Dispaly 7 different units of vacuum. Ideal for checking degree of vacuum! Usable in narrow areas with a cable 75mm typed sensor! 65mm 30mm Measuring range Sensor Working temperature Power source 3.33 0 3 Pa abs. (5000micron) ~.33Pa abs. (0 micron) Thermal conductivity sensor 0~9 C 9V alkaline battery 0.3kg (including battery) Thermal conductivity sensor Replaceable plug - in sensor. For checking vacuum condition in the system Electronic Vacuum Gauge PAT.P (high precision vacuum measuring device) Code No.Y69075 Low battery indicator Quick responding detachable electronic sensor. Measures degrees of vacuum in refrigeration cycle. With temperature correction control. Measuring range Sensor Working temperature Power source 0 0 3 Pa abs. (760,000 micron) ~0.33Pa abs. ( micron) Thermal conductivity sensor 0~9 C Alkaline battery.3kg To check degree of vacuum in area where accuracy specially required!! 30mm 30mm 60mm 6

Manifold with vacuum gauge Vacuum Single Manifold Code No.VT0 Vacuum gauge Port size 0~ 0.MPa /" Flare (UNF 7/6 0TPI) Easy to operate with ball valve. Ideal for testing after vacuuming with friction pointer. Ideal for checking vacuum retention!! Easy to find leakage with big gauge and friction pointer!! REFRIGERANT SERVICE TOOLS Pressure range Gauge diameter Port size 0~ 0.MPa ø80mm /" Flare female /" male with ball valve Adapter for different diameter (/" Flare female 5/6" Flare male) Vacuum gauge (with ball valve) for vacuum pump Small Vacuum Gauge with Valve Code No.XP76 Just install to /" port, can check pressure and vacuum retention easily!! /" Flare male Pressure range Gauge diameter Applicable vacuum pump 0~ 0.MPa ø0mm Adapter for different diameter (/" Flare female 5/6" Flare male).8cfmeco, CFMEco /" Flare female For vacuum testing of plumbing Vacuum Test Gauge Code No.Y0005A For vacuuming of A/C, for checking vacuum pump and vacuum test for pipings. For vacuum test of systems after refrigerant recovery and for checking vacuum degree inside of cylinder. Screw diameter Pressure display Flare /" female 0~ 0.MPa For vacuum check in recovery cylinder Hose with Vacuum Gauge Code No.Y0003A For checking the degree of vacuum in cylinder before the refrigerant recovery. Before recovering gas side Check cylinder before recovery Before filling Screw diameter Pressure display Flare /" female 0~ 0.MPa Check system after recovery 7

Need of vacuuming as seeing from a leakage prevention Imperfect vacuuming Mixed air Mixed air Abnormal pressure during operation Abnormal pressure during operation Trouble of system running of safety valve Leakage of refrigerant Burn out, corrosion, and break of system caused by acid content Damage by clogging Enough vacuuming How to check degree of vacuum of Digital vacuum gauge Electronic vacuum gauge ( ) Change the vacuum pump oil. Install digital vacuum gauge to vacuum pump after switching on. Caution: Please use a copper pipe when connecting. (If using a charging hose, the measurement will be a failure.) 3 Read the scale after 5 to 0 minutes. If the scale is below 00Pa (absolute pressure) no problem to use. 5 If not reaching yet, do Power Flushing and check the pressure again. 6 If the degree of vacuum is still not enough, repairing of pump unit is necessary. Digital vacuum gauge evacⅠ 8