Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Desuperheaters

Similar documents
Fisher ENVIRO-SEAL Bellows Seal Bonnets

Yarway Narvik Steam Desuperheater Series 4300 TempLow

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

280 SERIES STEAM CONVERTING VALVE SIZING AND SELECTION. 1. Introduction Design Properties Sizing and Selection Criteria...

VO-ll & VO-76 VARIABLE ORIFICE DESUPERHEATER

Fisher LCP100 Local Control Panel

DAM-D. Engineering GREAT Solutions. Steam Desuperheater

Steam-Atomising Desuperheater

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Economical and simplified solutions that offer quality and optimum steam trap service.

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Boiler Basics. Design and operation

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

The right trap for the right application.

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Copyright 1984 by ASME DESIGN OF A HEAT RECOVERY STEAM GENERATOR

All All kin kin ds of Co t n r t ol V ol V v al es v Self-Actu Act a u ti a ng ng e Pr ss e ur ss e R egu e R

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Fisher Means Control. Introducing a new standard in self-powered temperature control valves. FISHERregulators.com

Chapter-8 Capacity Control of Refrigeration Systems

The Ultimate in Direct Contact Water Heating. by Thermal Engineering of Arizona, Inc. An Inc. 500 Company

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

All All kin kin ds of Co t n r t ol V ol V v al es v Self-Actu Act a u ti a ng ng e Pr ss e ur ss e R egu e R

Hazardous Area Classifications and Protections

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

ASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1.

Technical Information

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

Condensate Recovery and Return System SDR A

INDUSTRIAL HEAT EXCHANGERS

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

"NP" & "RG" AIRFLO. In-duct firing line burner

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

APX. Nozzle-mix line burner

GB Steam desuperheating overview

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Drum Level Instrumentation and

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

Custom Design TYPE CS

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Top performance when the going gets tough

High-Pressure Atomizing System

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Multistage Centrifugal Blowers

APPLICATION REPORT Isomerisation This diagram is intended to be a representation and should not be viewed as an actual process flow diagram.

A product of tomorrow s technology.

13-1. Temperature Regulator

Vacuum distillation APPLICATION REPORT

So far 2010 is proving to be

Drum Level Instrumentation and. The ASME Boiler Code Requirements. Presented by: Jim Kolbus. Topics

STEAM TRAPS

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

endless quality and support

Points to be Considered when Purchasing a Steam Jet Vacuum Pump

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

1/2 1-1/4 H.P. DISPOSER MODELS

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

The Significance of Reliable Pressure Control in Oilfield Burner Systems

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

TECHNICAL DATA. Wet 26a. February 22, 2009

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

Temperature controller for steam (PN 25) AVT / VGS - external thread

Originators of the Flexible Water Tube design

Application Engineering

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

MSL A B A BK3 OS P AB

Rental Boiler Specifications (Nebraska Boiler)

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

Revitalize Building Mechanical Systems (4619)

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Evolution of Steam Sub-metering at Penn State University

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

MODEL 4000A & 4001A ACCELEROMETER

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

Multistage Centrifugal Blowers

Our Know-How. Your Peace of Mind. Steam Solutions

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

INSTY-PAC EXTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

INSTY-PAC INTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

G315/6 Cast Iron Boiler

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

First Line of Safety: Farris Engineering

Transcription:

D144X012 Product Bulletin September 17 Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI desuperheaters can be used in many applications to efficiently reduce the temperature of superheated steam to the desired set point. Available variations are mechanically atomized (both fixed geometry and variable geometry) and steam assisted. are available for installation in steam lines from DN25 through DN1500 (NPS 1 through 60) in diameter and are capable of maintaining steam temperatures to within 6 C ( F) of saturation temperatures. W629 DMA-AF W9 DMA Available Insertion Style DMA A simple mechanically atomized desuperheater with single or multiple, fixed-geometry spray nozzles is intended for applications with nearly constant load. The DMA is installed through a flanged connection on the side of a DN150 (NPS 6) or larger pipeline. Maximum unit C v is.. X0260 W6299 DSA DMA-AF A variable-geometry, mechanically atomized, back-pressure-activated desuperheater with one, two, or three spray nozzles is designed for applications requiring control over moderate load fluctuations. The DMA-AF desuperheater (figure 1) is installed through a flanged connection on the side of a DN0 (NPS ) or larger pipeline. Maximum unit C v is 15.0. DMA-AF-HTC W6297 DVI www.fisher.com

Product Bulletin September 17 D144X012 DMA-AF-HTC The DMA-AF-HTC is functionally equivalent to the DMA-AF, however it is structurally suited for severe applications. The most common applications include boiler interstage attemperation, where the desuperheater is exposed to high thermal cycling and stress, high steam velocities and flow induced vibration. In addition to this specific application, the DMA-AF-HTC is suitable for other severe desuperheating application environments. The DMA-AF-HTC uses a construction optimized to move weld joints away from high stress regions. The desuperheater design incorporates an integral thermal liner inside the desuperheater body pipe. This minimizes the potential for thermal shock when cool water is introduced to the unit that is already heated to the operating steam temperature. The nozzle mount for the DMA-AF-HTC is engineered to minimize the potential for excitation due to vortex shedding and flow induced vibration. The DMA-AF-HTC desuperheater (figure ) is installed through a flanged connection on a DN0 (NPS ) or larger pipeline. Maximum unit C v is 15.0. DSA The DSA desuperheater uses high-pressure steam for rapid and complete atomization of spraywater in low-velocity steam lines. This desuperheater (figure 2) is installed through a flanged connection on a DN0 (NPS ) or larger pipeline. This desuperheater is intended for applications requiring high rangeability. Maximum unit C v is 9.97. Available Ring Style DVI This desuperheater injects spraywater in the outlet of the venturi section, assuring excellent mixing and rapid atomization. The DVI desuperheater (figure 4) is easily installed between flanges in DN25 through DN600 (NPS 1 through 24) steam lines. There are no moving parts, and the water injection pattern provides rapid and thorough cooling. It is intended for applications with moderate load changes and low-velocity steam. Maximum unit C v is 9.4. 2

D144X012 Product Bulletin September 17 Specifications Available Types DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI (see the Available Desuperheater Types section for descriptions) Connections See table 1 Maximum Pressure Rating (1) Consistent with applicable pressure-temperature ratings (as shown in table 1) per ASME B.4 Inherent Rangeability Up to 50:1. The ratio of maximum to minimum controllable C v is dependent upon the available water pressure differential Spray Water Pressure Required (2).5 to 5 bar (50 to 500 psi) greater than steam line pressure Atomizing Steam (Design DSA) Atomizing steam should be at least 2.0 times the pressure of the steam to be desuperheated. Amount 1. Do not exceed the pressure or temperature limits in this bulletin, nor any applicable code or standard limitations. 2. A function of required turndown and equipment selection. of atomizing steam will be % of maximum spraywater flow Maximum Unit C V (for Spraywater Flow) DMA:. DMA-AF: 15.0 DMA-AF-HTC: 15.0 DSA: 9.97 DVI: 9.4 Construction Materials Desuperheater Body (all designs except DMA-AF-HTC): Carbon steel, Chrome-moly alloy steel (F22, F91), or 00 series stainless steel Desuperheater Body (DMA-AF-HTC): Chrome-moly alloy steel (F22, F91), or Carbon Steel (SA5) Note: NPS will have body-matched cast equivalent material for nozzle mount Nozzle Material DMA: 0 or DMA-AF, DMA-AF-HTC, and DSA: 4 stainless steel DVI: 0 or stainless steel or F22 venturi with drilled hole Table 1. Connection Sizes DESIGN STEAM LINE SIZE, NPS STEAM LINE CONNECTION SPRAYWATER CONNECTION ATOMIZING STEAM CONNECTION Size, NPS DMA 6-60, 4, or 6 DMA-AF -60 (2), 4, or 6 DMA-AF-HTC -60 or 4 DSA -60 (2), 4, or 6 ASME Pressure Rating Raised-Face Flange (1) CL150-1500 CL150, 00, 600, 900, 1500, or 2500 CL150, 00, 600, 900, or 1500 Size, NPS 1, 1-1/2, or 2 1, 1-1/2, 2, 2-1/2, or ASME Pressure Rating Raised-Face Flange (1) CL150-1500 Size, NPS N/A N/A ASME Pressure Rating Raised-Face Flange (1) N/A N/A 1-1/2 (), or 2 CL150-2500 N/A N/A 1, 1-1/2, or 2 CL150-2500 1, 1-1/2, or 2 CL150, 00, 600, 900, or 1500 DVI 1-24 1-24 CL150-2500 1/2, /4, 1, or 2 CL150-2500 N/A N/A 1. Other standard flanges and connections are also available. 2. Consult your Emerson sales office or Local Business Partner for acceptability of NPS mounting connection for size and pressure class specified.. DN 40 (NSP 1-1/2) spraywater connection is only available for CL150-900.

Product Bulletin September 17 Principle of Operation For the most efficient use of heat energy from steam, it is necessary to reduce the temperature of steam to near the saturation temperature. With steam that is at or near the saturation temperature, it is possible to recover the large amount of energy that was put into the steam when it was heated from water to steam. Desuperheating, or attemperation as it is sometimes called, is most often used to improve thermal efficiency of heat transfer processes by using steam near saturation, control unintentional superheat from pressure reduction of the steam, and protect downstream equipment and piping from elevated temperatures and pressure. The DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI desuperheaters produce a spray of cooling water in a steam line (figure 5). The spraywater cools the steam to near the saturation temperature or to a custom setpoint. The rate of cooling is dependent on spraywater droplet size, distribution, and velocity. The D144X012 temperature is controlled by varying the amount of spraywater flow. In operation, spraywater is supplied to a connection on the desuperheater. A signal from a downstream controller positions an actuator or valve to control the amount of spraywater flow for cooling. The spraywater control valve is a separate valve in the spraywater line. In the DSA desuperheater, high pressure steam is mixed with the spraywater to produce a critical or near-critical pressure drop in the atomizing steam for a very high velocity. The high velocity disperses the spraywater into very small particles for rapid cooling. In the DVI desuperheater, spraywater enters the desuperheater water tube. It continues into the distribution chamber and is forced into the injection orifices. Steam enters the desuperheating venturi and is accelerated to maximize the velocity at the point of water injection. The high steam velocity and turbulent steam flow improves mixing of water and steam, increasing rangeability. 4

D144X012 Product Bulletin September 17 Figure 1. Fisher DMA-AF Desuperheater Figure. Fisher DMA-AF-HTC Desuperheater W6-1 Figure 2. Fisher DSA Desuperheater W90-1 Figure 4. Fisher DVI Desuperheater W611-2 W61-1 5

Product Bulletin September 17 D144X012 Figure 5. Typical Installation FISHER 667-EZ SPRAYWATER CONTROL VALVE FISHER 667-EZ ATOMIZING STEAM ISOLATION VALVE SPRAYWATER ATOMIZING STEAM FISHER DSA DESUPERHEATER STEAMFLOW DSA DESUPERHEATER FISHER SPRAYWATER CONTROL VALVE TC SPRAYWATER FISHER DMA DESUPERHEATER STEAMFLOW B217 DMA, DMA-AF, OR DMA-AF-HTC DESUPERHEATER 6

D144X012 Product Bulletin September 17 Figure 6. Selection Flow Chart REQUIRED TURNDOWN GREATER THAN 5:1 REQUIRED TURNDOWN GREATER THAN 25:1 PIPELINE SIZE GREATER THAN NPS 6 REQUIRED TURNDOWN GREATER THAN :1 PIPELINE SIZE GREATER THAN NPS 6 STEAM PRESSURE REDUCTION REQUIRED PIPELINE SIZE GREATER THAN NPS 6 ATOMIZING STEAM AVAILABLE PRV w/ TBX-T DVI DSA TBX-T DMA-AF DVI DMA OR OR OR TBX DVI (NPS 6-24) DVI [NPS 6-24] OR OR TBX-T TBX-T A6619 Ordering Information Use the flow chart in figure 6 to select the appropriate desuperheater for your requirements. Dimensions are shown in figures 7,, 9, and. When ordering, specify the following information. Items 1 through 6 are required for desuperheater sizing. 1. Maximum, normal, and minimum steam flow rate. 2. Steam pressure and temperature at the inlet and outlet.. Spraywater pressure and temperature. 4. Atomizing steam pressure and temperature (DSA desuperheater only). 5. Design conditions, if different from operating conditions. 6. Steam line size. 7. Desuperheater steam connection size, type, and rating.. Spraywater connection size from table 1. 9. Atomizing steam connection size from table 1 (DSA desuperheater only). 7

Product Bulletin September 17 D144X012 Figure 7. Fisher DMA and DMA-AF Dimensions (also see table 2) A5094-1 (.0) ASME RF FLANGE T D FLOW ASME RF FLANGE (WATER) A mm (INCH) Table 2. Fisher DMA and DMA-AF Face-to-Face Dimensions DIMENSION A D (Nominal Pipe Size), T mm Inches NPS mm Inches 60 14.19 44 17.6 524.6 6 (1) 12 14 1 22 24 >24 27 24 2 279 267 241 2 267 241 2 2.75 9.75 11.00.50 9.50.50 9.50 1. DMA only. Note: For NPS 6 and (DMA-AF only) mounting flange, add 69.6 mm (2.75 inches) to the A and T dimensions. For CL2500 mounting, consult your Emerson sales office or Local Business Partner. Refer to the certified drawing to verify the inside-diameter requirements of mounting for DMA-AF. Table. Fisher DMA-AF Minimum Mounting I.D. ZZLE MODEL DMA - M Spray Nozzle VALVE BODY PIPE MINIMUM BODY FLANGE WATER FLANGE MINIMUM MOUNTING I.D. Size, NPS Size, NPS Size, NPS mm Inches 7.66 2.9 DMA -A through DMA - U 1, 1-1/2, or 2 5.42 2. Spray Nozzle 1 DMA-AF-A,B,C 66.65 2.624 1 DMA-AF-D,E 7.66 2.9 DMA-AF-A,B,C,D 77.9.07 DMA-AF-E 0.06.152 DMA-AF-F 4 1, 1-1/2, or 2 7..4 1-1/2 DMA-AF-G 92.05.624 DMA-AF-H 97.1.26 DMA-AF-J 6 1, 1-1/2, or 2 129.5 5.1

D144X012 Product Bulletin September 17 Figure. Fisher DSA Dimensions (also see table 4) ASME RF FLANGE (WATER) (.00) (.00) ASME RF FLANGE (STEAM) 152 (6.00) A5095-2 ASME RF FLANGE A T D FLOW mm (INCH) FLOW Table 4. Fisher DSA Dimensions DIMENSION A T D (Nominal Pipe Size), NPS mm Inches mm Inches 60 14.19 44 17.6 524.6 Note: For NPS 6 mounting flange, add 69.6 mm (2.75 inches) to the A and T dimensions. For CL2500 mounting, consult your Emerson sales office or Local Business Partner. 12 14 1 22 24 >24 24 2 279 267 241 2 267 241 2 2 9.75 11.00.50 9.50.50 9.50 9

Product Bulletin September 17 D144X012 Figure 9. Fisher DVI Dimensions (also see table 5) E ASME RAISED-FACE FLANGE (WATER) C.12 ( 0.125) ASME RAISED-FACE FLANGE B A 250 RMS SERRATED SURFACE D mm (INCH) A509-1 FLOW DIRECTION INSTALLATION CONFIGURATION (2 GASKETS REQUIRED) Table 5. Fisher DVI Dimensions MINAL PIPE SIZE, NPS A B C WATER CONNECTION TO MATING FLANGE PRESSURE RATING CL150 CL00 CL600 CL900 CL1500 mm D E 1 1-1/2 2 2-1/2 51 7 92 5 127 4 6 12 2 2 152 157 2 270 24 1 159 51 51 14 1 24 152 152 41 470 5 54 692 559 559 559 660 559 660 711 159 159 2 2 2 2 2 2 Inches 1 1-1/2 2 2-1/2 2.00 2..6 4.1 5.00.25.25.25.25.25 4 6 12 4 4 6 6.19.6 12.75 15.00.25.25 4.25 4.25 6.25 2.00 2.00.00 14 1 24 6 6.25 1 21.00 2.00 27.25 22 22 22 26 22 26 2 6.25 6.25.25.25.25.00.00 4.00 4.00 4.00

D144X012 Product Bulletin September 17 Figure. Fisher DMA-AF-HTC Dimensions (also see tables 6 and 7) E MOUNTING FLANGE (SAME SIZE & PRESSURE RATING AS BODY FLANGE) ZZLE APPLICATION B T FLOW DIRECTION D FLOW DIRECTION AVAILABLE ZZLE CONFIGURATIONS GA264-C Table 6. Fisher DMA-AF-HTC Dimensions WATER FLANGE DESUPERHEATER BODY FLANGE (1) DIMENSION Size, NPS Pressure Rating Size, NPS Pressure Rating 1-1/2 2 mm E (Standard) CL150 or 4 CL150 CL00 or 4 CL00 CL600 or 4 CL600 CL900 or 4 CL900 CL150 or 4 CL150 CL00 or 4 CL00 CL600 or 4 CL600 CL900 or 4 CL900 CL1500 or 4 CL1500 Inches CL2500 or 4 CL2500 292 11.5 1. The NPS 4 DMA-AF-HTC requires a 4.00 inch minimum mounting I.D. Contact your Emerson sales office or Local Business Partner for NPS DMA-AF-HTC minimum mounting I.D. Table 7. Fisher DMA-AF-HTC Installation Dimensions DIMENSION D (Nominal Pipe Size) Desuperheater Body Flange Size, B (Insertion Length) T (Height) mm NPS NPS mm Inches mm Inches 0 or 4 56 14.00 24 9.75 250 or 4 56 14.00 2.5 00 12 or 4 444 17.50 279 11.0 50 14 or 4 444 17.50 267.5 400 or 4 444 17.50 241 9.5 450 1 or 4 444 17.50 2.5 500 or 4 444 17.50 2.5 550 22 or 4 444 17.50 2.5 600-900 24-6 or 4 444 17.50 2.5 11

Product Bulletin September 17 D144X012 Table. Fisher DMA-AF-HTC Minimum Mounting I.D. MINIMUM BODY FLANGE ZZLE MODEL WATER FLANGE MINIMUM MOUNTING I.D. DMA-AF-A,B,C 1-1/2 to 2 2.624 DMA-AF-D,E 1-1/2 to 2 2.9 4 DMA-AF-A through H 1-1/2 to 2 4 Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 5015 USA Sorocaba, 107 Brazil Cernay 6700 France Dubai, United Arab Emirates Singapore 12461 Singapore www.fisher.com 12199, 17 Fisher Controls International LLC. All rights reserved.