40KMC KMQ

Similar documents
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

51AKS I S O OWNER S MANUAL

Owner s Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

53 KNL / 53 QNL OWNER S MANUAL

KSD-35 DR11 KUE-35 DVN11

Owner s Manual Super-Slim Four-Way Cassette

Hi Wall Split Air Conditioners

42XQ 42XQA. 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Slim Line Ceiling Concealed Ducted Split Systems

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

High Wall Split Air Conditioners 53QHCT KHCT

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Bosch Split-Type Ductless Air Conditioner / Heat Pump

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Owner s Manual TABLE OF CONTENTS

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OPERATING INSTRUCTIONS

Operating Instructions Air Conditioner

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

51AKB / 51 AKC OWNER S MANUAL

Reverse Cycle Split System Air Conditioner

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

Inverter Split-type Room Air Conditioner

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

5) Do not start or stop the unit by inserting or pulling out the power plug.

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Owner s Manual CS

Operating Instructions Air Conditioner

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

Operating Instructions Air Conditioner

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Indoor Unit (2 Series)

OPERATING INSTRUCTIONS

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Operating Instructions

OPERATING MANUAL COOLING MODEL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST9ASJCW AST12ASJCW

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

SPLIT - TYPE ROOM AIR CONDITIONER

PORTABLE AIR CONDITIONER OWNER S MANUAL

AIR CONDITIONER OPERATING MANUAL. Cassette type. Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA. PART No

Operating Instructions Air Conditioner

Owner s Manual TABLE OF CONTENTS

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

Ducted air conditioner Operating Manual

Compact Cassette Type

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

Operating Instructions

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

OWNER S MANUAL VMH 09/12/18/24

RAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

User manual AG-WT10. Indoor unit air/air heat pump UHB GB LEK

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

PORTABLE AIR CONDITIONER OWNER S MANUAL

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Split Air Conditioner

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Operating Instructions Air Conditioner

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Operating Instructions

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

CEILING CASSETTE OWNER S MANUAL. Models:

NEXXOS INVERTER USER MANUAL

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

Wall Mounted Mini Split Heat Pump Air Conditioner

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

MA Remote Controller PAR-31MAA

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Operating Instructions Air Conditioner

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

User s Information Manual

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Transcription:

40KMC------301 40KMQ------301 OWNER S MANUAL

Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier Room Controller or Zone Manager remote control. Carrier Room controller control instructions are contained in the present manual. Infrared Remote and Zone Manager controls instructions are contained in the relevant manuals. The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit. Contents Page ENGLISH General information... 2 System description... 2 Unit LEDs and controls... 3 Periodical checks... 3 Optimum comfort and minimum power consumption... 4 Correct cleaning... 4 Before a long shutdown period... 4 Room controller general information and characteristics... 5 Unit protection devices... 5 Room controller wired control... 6/7 Troubleshooting... 8 GB - 1

General information Unit operation and maintenance Read this instruction manual thoroughly before using the unit. This unit complies with UL 1995 directive (Usa and Canada). Check that the main power supply voltage and frequency are as required for the unit; the power source must be sufficient to operate all other appliances connected to the same line. Also ensure that local building codes and NEC (National electrical code) requirements have been followed for the main supply circuit. To avoid personal injury or damage to unit,do not service until all power sources are shut down, locked out, and tagged out. Failure to do so could result in personal injury or unit damage.! WARNING: To prevent fire, explosion or injury, do not operate the unit near dangerous substances or esposed to lighting equipment. All operation and maintenance manuals must be carefully looked after and kept with the equipment, should the unit change owners. Check that local building codes and NEC (National electrical code) requirements for the installation have been followed. In particular, ensure that a properly sized and connected ground wire is in place. Only use the unit for factory approved applications: the unit cannot be used in laundry premises. Do not use damaged equipment. In case of malfunction, turn the unit OFF and disconnect the main supply. Disconnect the main power supply prior to any maintenance operations or prior to handling any internal unit parts. The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or refrigerant connections, made during the installation, or from improper use of this equipment. This will invalidate the unit warranty conditions immediately. This unit will only work safely and correctly, if installed and tested by qualified personnel. Do not open the remote control to avoid possible damage. In case of malfunction contact a qualified service engineer. This unit contains moving parts. Ensure that these parts are kept out of the reach of children. Maintain the room temperature at general comfort conditions, especially when children, elderly or handicapped persons are present. In order to ensure correct use, the air conditioner must operate within the temperature limits indicated in the Operating Limits table, included in the Technical manual. Failure to observe these limits may cause unit malfunction or water leakage. In order to avoid electric shock, fire or injury, stop the unit and disconnect the safety switch in case of abnormal events (such as smell of burning) and call Carrier Service for further instructions. A routine maintenance should be carried out on the unit to check the correct operation of the electric connections and protection devices. Extraordinary maintenance operations must be carried out by specially trained personnel. Do not attempt to repair, move, modify or re-install the unit on your own. To avoid electric shock or fire make sure these operations are carried out by qualified personnel only. Contact the qualified service if one of the following events takes place: - hot or damaged power supply cable; - unusual noise during operation; - frequent operation of the protection devices; - unusual smell (such as smell of burning).! WARNING: Never operate unit without a filter or with grille removed. Damage to the unit or personal injury may result.! WARNING: If air filter is not replaced in the unit, dust and dirt gather in air conditioner and operation becomes impaired. A mist or cloud of vapor may be emitted from the unit, when switching from a cooling operation to a reverse cycle heating operation. This will occur when the unit has been operating in cooling mode for awhile and then is switched to heating. The combination of the evaporated indoor coil condensate and the dry room air, may result in a cloud of vapor being emitted from the unit. There is no need for concern. Inspect equipment for damage during transport. In case of damage file an immediate claim with the shipping company. Non-routine maintenance of the refrigerant circuit must only be carried out by qualified personnel. All of the manufacturing and packaging materials used for this appliance are biodegradable and recyclable. Dispose of the packaging material and of the remote control batteries in accordance with local requirements. This equipment contains refrigerant that must be disposed of correctly. When disposing of the unit at the end of its operational life, take the unit to an authorised waste disposal centre, for correct disposal procedures.! WARNING: The unit must always be switched OFF using the Room Controller. Do not switch OFF the split system by disconnecting the electric power supply. System description 7 6 1 2 3 4 5 B A. Outdoor unit B. Indoor unit C. Room Controller (if foreseen) 1. Air return 2. Air filters 3. Air supply 4. Operation indicator light and receiver of remote control signals (if foreseen) 5. Nameplate 6. Interconnecting tubing 7. Condensate drain (open) A C GB - 2

Unit warning lights and controls - Fault code ENGLISH P : Green LED Q : Red LED R : Yellow LED S : Remote control signal receiver Indoor unit LEDs Information concerning indoor unit operation, timer status and diagnostic is given by 3 LEDs located on the unit. THE GREEN LED (P) shows the following conditions: - Fault codes (diagnostic); - During normal operation, the LED is lit. Once a failure occurs, the LED flashes at intervals of 0.5 seconds. The fault code is deduced from the number of times the LED flashes. Between one flash cycle and the next a pause of 5 seconds elapses. THE RED LED (Q) gives the following information: - During normal operation, the LED is OFF; - During defrost the LED is lit; - During the test for wired connection, the LED flashes at 0.1 second intervals. THE YELLOW LED (R) shows the operation in timer mode. During this operation the LED is lit. If the timer mode is active and the unit is immediately restarted after a stop, this LED flashes until a new signal is sent to the unit. In case the Room Controller is not working, obtain a qualified service personnel. Fault code Once a failure occurs with the indoor unit in operation, the green unit LED flashes at intervals of 0.5 seconds. The fault code is deduced from the number of times the green LED flashes, blocking unit operation. Between one flash cycle and the next one, a pause of 5 seconds elapses. Table IX: Fault code Code * with enabled code Description 3 Room air sensor fault 2 Condensate discharge pump 4 Indoor unit coil sensor fault 6* Filter dirty 7 Outdoor unit failure 10 EEPROM corrupt 11 Card serial number damaged 12 Address / zone incomplete 13 Gas flow distributor corrupt 14 Outdoor air thermistor Table II: Periodical checks Indoor unit Every month Every 4 months Every year Clean air filter (2) (1) Clean drain pipe (2) Outdoor unit Every month Every 4 months Every year Clean outdoor coil from outside Clean outdoor coil from inside (2) Blow air over electric parts (2) Check electric connection tightening (2) Clean fan wheel (2) Check fan tightening (2) Clean drain pan (2) For a good operation of the air conditioner it is recommended to carry out checks and maintenance as indicated. Recommended maintenance intervals may vary depending on the installation environment, e.g. dusty zones, etc. (1) Increase frequency in dusty zones. (2) Operations to be carried out by qualified service personnel. Refer also to Installation Manual. GB - 3

Optimum comfort... - Correct cleaning - Before a long shutdown period Optimum comfort and minimum power consumption Correct cleaning Turn the unit OFF and switch the main supply OFF. Keep room temperature at a comfortable level. Use only a clean, damp cloth and a mild detergent. Do not use flammable liquids, solvents or abrasive powders that may result in damage to the panels. Use only a dry cloth to clean the remote control. Before a long shutdown period Only open doors and windows when strictly necessary. Ask to clean the filter and replace it in the unit. 12 h When cooling, avoid direct sunlight in the room: if possible, draw the curtains or close the shades. Do not obstruct the air intake or outlet of the indoor unit. Obstructions will cause a reduction in the air flow and the conditioning effect, resulting in unit malfunction. Keep the unit in operation for half a day in the ventilation (fan only) mode in order to dry all internal parts. Ensure that the air filters are clean. Ensure that the air distribution in the room is uniform by properly adjusting the air flow direction. Switch the unit OFF and wait for at least 3 minutes before switching OFF the main electric supply. Periodically clean the area surrounding the outdoor unit and the air intake, in order to avoid reduced air circulation. Keep heat sources away from the unit: panels may be damaged. Clean indoor and outdoor units. GB - 4

Room controller general information and characteristics ENGLISH A E D B C A = Display readout B = Increase temperature / change louvre setting button C = Decrease temperature / change louvre setting button D = Fan selection button E = Mode selection button Display of selected functions Characteristics Single unit operation: Ability to control one unit only. Grouping: Ability to control 2 to 6 units with one Room Controller. Operating modes: Off, Heat, Cool, Dry, Auto, and Fan only. Fan speeds: Low, Medium, High, and Auto. Louver control: Auto and swing. Desired temperature: Range between 17 and 32 C (63 and 90 F). Room Thermistor Override: Allows to use air sensor located in the Room Controller instead of the one located into the unit. Diagnostics: Detects the fault of air sensor in the Room Controller. A1 shown on the screen indicates this anomaly. up down UP and DOWN buttons Buttons for raising or lowering the temperature or for selecting the AUTO or SWING louver mode. Automatic Off Temperature selected / room temperature Set temperature Operating position of the air louvre Fan speed Heating Cooling Dehumidification only MODE Button for operation mode selection. FAN Button for fan or louvre selection. Table I: Unit protection devices System Type of protection Effect of protection Operation mode When on Heat pump Cold draft prevention Defrost cycle Indoor fan off Indoor fan off Heating in heat pump mode Heating in heat pump mode During unit operation During unit operation Indoor coil Cooling only freeze protection Compressor off Cooling During unit operation and heat pump Against frequent Compressor Cooling or heating At unit start-up or compressor cycling time delay in heat pump mode change of operating mode WARNING: During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit in very low ambient temperatures. In these cycles, the indoor fan will be automatically off and cannot operate until defrost cycle is completed. GB - 5

Room controller wired control Power up All segments of the LCD should be energized for five seconds. The mode, fan, louver, desired temperature and configuration information should be read from the EEPROM. If the EEPROM values are not valid, the following should be used as defaults. Operating Mode = AUTO Fan Speed = AUTO Desired Temperature = 72 F F o C = F Louver = AUTO Room Thermistor Override = OFF Cooling only vs Heat/Cool Remote = Heat/Cool AUTO, HEAT, COOL and DRY Modes: ICONS Energized: Operation Mode ICON. Room Temperature if configured for Room Thermistor Override (operated by Room Controller), otherwise user selected temperature with the SET TEMP Icon. FAN/LOUVER Icon with the user selected Fan and Louver settings. Buttons available: All Buttons are available. AUTO Automatic operation Example of normal operation When switched on, the control display appears. NOTE: The compressor and electric heater must be off for at least 30 Minutes, this time being necessary to pass from Heating to Cooling, or Cooling to Heating. This will prevent the system from switching between Heating and Cooling continuously. Setting mode operation MODE button Pressing the MODE button will cause the mode to change. The MODE button must be released and then pressed again in order to change to the next mode. The active mode will always be lit in normal operation. Available modes to select are: Heat/Cool Remote: OFF, COOL, DRY, FAN ONLY, AUTO, HEAT COOL Cooling operation Cooling Only Remote: OFF, COOL, DRY and FAN ONLY When the MODE button is not pressed for 15 seconds, the next press will always switch the mode to OFF. OFF Mode: ICONS Energized: OFF Mode Room Temperature if configured for Room Thermistor Override, otherwise nothing Buttons available: MODE button DRY Drying operation. HEAT Heating operation. GB - 6

Room controller wired control ENGLISH FAN ONLY Mode: ICONS Energized: Room Temperature if configured for Room Thermistor Override (operated by Room Controller), otherwise nothing. FAN/LOUVER Icon with the user selected Fan and Louver settings. Buttons available: MODE and FAN buttons are available. Auto mode setting will be displayed by blinking the fan Medium speed and High speed icons in order (Med then Hi then repeat). Low Medium High Automatic (Fan speed will automatically switch to the value required for optimum comfort). When this function is activated, the dotted symbols will flash. Louver mode selection fan only Ventilation operation only. UP and DOWN button (Selecting the desired temperature) up down Pressing either the UP or DOWN buttons will modify the desired temperature. The maximum desired temperature is 32 C (90 F) and the minimum desired temperature is 17 C (63 F). Whenever the setpoint is being displayed, the SET TEMP icon is illuminated. Whenever the display mode is changed from C to F, the setpoint is set to the default start-up values of 22 C for C mode and 72 F for F mode. To enter louver mode selection, make sure the Room Controller is on and hold the FAN button down for 5 seconds. After 5 seconds, the selected louver setting will be displayed. By pressing the up and down buttons the user can modify the louver desired configuration. The two settings will be displayed in the following way: S with Swing Louver Icon - represents Swing Louver. A with Auto Louver Icon - represents Auto Louver. Press FAN button to exit LOUVER Mode Selection. This mode will exit automatically after 10 seconds if no buttons are pressed. The only way to change the operation mode, is to go back to this menu. NOTE: If units are grouped to one Room Controller, all units will end up having the same louver value. Louver Mode selection is not available during OFF mode. If the air sensor built in the Room Control is enabled, the display will indicate the room temperature after few seconds. :AUTO Automatic louvre positioning to the best position for the selected operating mode. FAN button (Adjusting the ventilation speed) Pressing the FAN button will cause the fan speed to change. The FAN SPEED button must be pressed and then released to reach the desired speed (Low, Medium, High or Auto). The icon on the display indicates that change has occurred. :SWING Louvres swing continuously. GB - 7

Troubleshooting No Room controller LCD display: Mis-wiring of the 12 volt power to Room Controller control; verify that + 12 V and Ground are connected to the proper terrminals of the Controller (Reference Installation wiring section for correct connections): after disconnecting the power, correct the wiring problem and re-cycle power. Power not online; check that the units main power is connected. The main control board should be operating normally: after verifing the wiring to the Room Controller, re-cycle the unit power. No 12 volts between P and G of terminal block; check the installation of the J6 plug on the main control board: after disconnecting the power, correct the wiring problem and re-cycle power. Note: Those verifications need to be carried out by qualified personnel only. +12 volts applied to Room Controller at the correct terminals and still does not operate: The Room Controller is damaged; change the Room Controller and re-cycle power. Note: This operation needs to be carried out by qualified personnel only. Air conditioner will not start: The main switch is switched OFF, place the switch in the ON position. The fuses on the main switch are burnt out; replace the fuses. ( this operation need to be carried out by qualified personnel only). Wait for 3 minutes: protection against frequent compressor cycling is ON. Selected temperature is higher than the room temperature (or lower in the heating mode). Air conditioner is not supplying enough cooling (or heating): Air cannot circulate freely. Dirty filter reduces air quantity circulating. Filter must be cleaned by skilled personnel only. Doors and/or windows are open. Fan speed has been set to low. Air flow direction is not correct for optimum ventilation. Selected temperature is not correct. service, please refer to the installation instructions. Restart air conditioner after having corrected the faults. Q (Red LED) indicator is illuminated: In the heating mode, the LED switches on to indicate an active defrost condition. The unit emits unpleasant smells: Unpleasant smells can accumulate on the air filters and then be dispersed into the room during air conditioner operation. Switch the unit OFF and contact an authorised service centre to have the filters cleaned. Restart unit in the ventilation (fan only) mode and open windows to change room air. The unit makes strange noises: Occasionally the unit makes strange noises at start-up, during operation or when it has stopped. These are generally due to the effect of temperature changes on the plastic parts. Mist or Vapor Cloud emitted at start-up of Heating operation: A mist or cloud of vapor may be emitted from the unit, when switching from a cooling operation to a reverse cycle heating operation. This will occur when the unit has been operating in cooling mode for awhile and then is switched to heating. The combination of the evaporated indoor coil condensate and the dry room air, may result in a cloud of vapor being emitted from the unit. There is no need for concern. WARNING: (models with electric heaters): If the manual reset, thermal trip device cuts out, switch the unit OFF and ON again at the main switch to reset. If the malfunction persists, contact your local authorised dealer. A slight mist is emitted from the unit: A slight mist, coming out of the unit air outlet, is sometimes noticed during cooling operation. This is due to the cool air coming into contact with the room air. A slight whistling noise is heard when the air conditioner starts or stops: This is due to the refrigerant beginning to circulate or an adjustment of the refrigerant pressures. This is a normal operating condition. P (Green LED) indicator is flashing: System malfunction. Contact service organisation after having ensured that: Air circulation is not obstructed. Outdoor unit coil is not obstructed and causing severe reduction of air circulation. Condensate drainage tube is not obstructed. As regards fault codes to be communicated to the after-sales GB - 8

L010127H09-0306 Via R. Sanzio, 9-20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. March, 2006. Printed in Italy