BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Similar documents
FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

BS EN ISO : 2010

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

BS EN ISO : 2010

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

WITH OMRON E5CC CONTROL

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Australian Standard. Methods for fire tests on building materials, components and structures

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

BS EN ISO : 2010

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

LABORATORY ILLUMINATED FLOTATION BATH

Emergency. Management. Emergency. Readiness Checklist

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

DELIVERING DURABLE, AFFORDABLE WINDOWS & DOORS

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

AS/NZS 4012:1999 AS/NZS

NF X : Parts 1, 2, 3, 4 & 5

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Australian/New Zealand Standard

Test Report: ICL/CR15/11/087

AMPLIMESH SECURITY DOOR & WINDOW SCREENS

AMPLIMESH SECURITY DOOR & WINDOW SCREENS

AMPLIMESH SECURITY DOOR & WINDOW SCREENS

AMPLIMESH SECURITY DOOR & WINDOW SCREENS

Fire Curtains and Radiation Attenuation

Review Fire Test Report

2 Examination of Cladding Panels (Laboratory)

MARKET ACCESS & DEVELOPMENT PROJECT NUMBER: PNA APRIL 2009

Australian/New Zealand Standard

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

BCTC CARPET TECHNICAL CENTRE

BUSHFIRE THREAT ASSESSMENT REPORT. Special Fire Protection Purpose Development. North Byron Beach Resort. Proposed Central Facilities

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

SENJU SPRINKLER CO., LTD.

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Data Sheet 4.16 Issue D

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Intumescent Fire Dampers

HazLoc Essential Guides:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

IMO Resolution MSC 61(67): Annex 1: Part 2

MEDIUM-DENSITY HOUSING # 7. Fire safety

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Aon Sprinkler Certification Technical Note

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

AS/NZS :2014

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

REFRIGERATED RECIRCULATORY COOLER

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

OWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models

SIGMADEK, LTD. FIRE TEST REPORT

Data Sheet 4.24 Issue F

Food Service Technology Center

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

Fire Collars for Floor Wastes Understanding BCA Compliance Options

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Australian/New Zealand Standard

FISHER & PAYKEL HEALTHCARE CORPORATION LIMITED

BS EN : 2001 & IEC :2000

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/H18/9039 Rev 1

FUNDERMAX GMBH FIRE TEST REPORT

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CERTIFICATE OF FIRE APPROVAL

Information Bulletin

Transcription:

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS Report number FSZ 1572 CSIRO job number SV3559 Date of issue 22 FEBRUARY 2013 Client BREEZWAY AUSTRALIA PTY LTD Commercial-in-confidence Copyright CSIRO 2013 Copying or alteration of this report without written authorisation from CSIRO is forbidden. CSIRO MATERIALS SCIENCE AND ENGINEERING 14 Julius Avenue, Riverside Corporate Park, North Ryde NSW 2113 Ph: 02 9490 5444 Fax: 02 9490 5528

REPORT No. FSZ 1572 Page 2 of 21 Use of this Report Use of Reports Testing This report is subject to binding obligations under which it was prepared. In particular, the Report must not be used: as a means of endorsement; or in a company prospectus or notification to a Stock Exchange document for capital raising, without the prior written consent of CSIRO. The Report may be published verbatim and in full, provided that a statement is included on the publication that it is a copy of the Report issued by CSIRO. Excerpts of the Report may not be published. Use of Reports Consultancy This report is subject to binding obligations under which it was prepared. In particular, the Report may only be used for the following purposes: the information in the Report may be used by the party that commissioned the Report for its internal business operations (but not licensing to third parties); the report may be copied for distribution within the organisation that commissioned the Report; copies of the Report (or extracts of the Report) may be distributed to contractors and agents of the organisation that commissioned the Report who have a need for the Report for its internal business operations. Any extracts of the Report distributed for this purpose must clearly note that the extract is part of a larger Report held by the organisation that commissioned the Report and which has been prepared by CSIRO. The name, trade mark or logo of the CSIRO must not be used without the prior written consent of CSIRO. The Report must not be used as a means of endorsement without the prior written consent of CSIRO. Copyright and Disclaimer 2013 CSIRO To the extent permitted by law, all rights are reserved and no part of this publication covered by copyright may be reproduced or copied in any form or by any means except with the written permission of CSIRO. Important Disclaimer CSIRO advises that the information contained in this publication comprises general statements based on scientific research. The reader is advised and needs to be aware that such information may be incomplete or unable to be used in any specific situation. No reliance or actions must therefore be made on that information without seeking prior expert professional, scientific and technical advice. To the extent permitted by law, CSIRO (including its employees and consultants) excludes all liability to any person for any consequences, including but not limited to all losses, damages, costs, expenses and any other compensation, arising directly or indirectly from using this publication (in part or in whole) and any information or material contained in it.

REPORT No. FSZ 1572 Page 3 of 21 Table of Contents SUMMARY... 4 IDENTIFICATION OF SPECIMEN:... 4 SPONSOR:... 4 MANUFACTURER:... 4 TEST STANDARD:... 4 TEST NUMBER:... 4 TEST DATE:... 4 DESCRIPTION OF SPECIMEN:... 4 ORIENTATION... 8 CRIB SIZE... 8 LEVEL OF RADIANT HEAT EXPOSURE... 8 DOCUMENTATION:... 8 EQUIPMENT:... 8 AMBIENT TEMPERATURE:... 9 TERMINATION OF TEST:... 9 TEST RESULTS:... 9 CRITICAL OBSERVATIONS... 9 RADIANT HEAT FLUX... 10 PERFORMANCE... 10 APPENDICES... 12 APPENDIX 1... 12 Photograph 1 - Exposed face of the specimen prior to testing... 12 Photograph 2 - Unexposed face of the specimen prior to testing... 12 Photograph 3 - Specimen at the start of the testing... 13 Photograph 4 - Specimen 2 at 2 minutes into the test... 13 Photograph 5 - Exposed face of the specimen at 17 minutes into the test... 14 Photograph 6 - Unexposed face of the specimen at the completion of testing... 14 Photograph 7 - Exposed face of the specimen at the completion of testing... 15 APPENDIX 2... 16 Figure 1 - Radiant Heat Flux... 16 Figure 2 - Radiant Heat Flux received @ 365-mm from the unexposed face... 17 Figure 3 - Radiant Heat Flux received @ 250-mm from the exposed face... 18 APPENDIX 3... 19 Drawing numbered EZY Fire Testing sheet 1, dated 15 February 2013, by Breezway... 19 Drawing numbered EZY Fire Testing sheet 2, dated 15 February 2013, by Breezway... 20 Drawing numbered EZY Fire Testing sheet 3, dated 15 February 2013, by Breezway... 21

REPORT No. FSZ 1572 Page 4 of 21 SPONSORED INVESTIGATION No. FSZ 1572 BUSH FIRE TEST ON GLAZED VERTICAL ELEMENTS SUMMARY IDENTIFICATION OF SPECIMEN: The sponsor identified the specimen as aluminium framed glass window assembly. SPONSOR: Breezway Pty Ltd 35 Cambridge Street COOPAROO QLD MANUFACTURER: Breezway Pty Ltd 35 Cambridge Street COOPAROO QLD TEST STANDARD: Australian Standard 1530, Methods for fire tests on building materials, components and structures, Part 8.1-2007: Tests on elements of construction for buildings exposed to simulated bushfire attack radiant heat and small flaming sources. TEST NUMBER: FS 4325/3559 TEST DATE: The fire test was conducted on 10 January 2013 DESCRIPTION OF SPECIMEN: The specimen comprised six glass window installations, mounted into a 2400-mm wide x 2400-mm high opening in a double brick wall. The glass window assembly was mounted into Easyscreen aluminium frame. The glass window assembly was retro-fitted into the opening in a double brick wall using masonry anchors spaced at nominally 600-mm centres.

REPORT No. FSZ 1572 Page 5 of 21 Specimen 1: Fire Retardant Altair Louvre aluminium framed window including MK2 Clips The specimen comprised an 1194-mm high x 799-mm wide Altair Louvre window, mounted into an aluminium Easyscreen Frame and Easyscreen Mullions with mullions profiles shown in drawing numbered ESY Fire Testing sheet 1, dated 15 February 2013, by Breezway. The adjustable louvre system comprised eight sections of 720-mm long x 152-mm wide x 6-mm thick toughened glass fitted within MK2 clips. The MK2 clips, stated to be made of Retpol PDR 9044 UVA copolymer polypropylene compound, were held to the aluminium frame by MK4 bearings, retainers, pins and stabilisers stated to be made of Acetal. A nominal 3.2-mm clearance between the glass edges and the clips was maintained along the vertical sides The Low Profile Handle was stated to be made of stainless steel. Along the bottom of the glass window, a Marcott SCE17-27 FR Wheatherseal was installed as shown in drawing numbered ESY Fire Testing sheet 3, dated 15 February 2013, by Breezway. On the exposed face of the window, a 1194-mm high x 800-mm wide x 0.9-mm thick Tensile-Tuff Crimsafe 304 grade stainless steel security mesh was fixed to the aluminium frame by 22-mm Self Drilling Pan Head screws at 300-mm centres. Details of construction are specified in drawings numbered ESY Fire Testing sheets 1 and 3, dated 15 February 2013, by Breezway. Specimen 2: Fixed Lite aluminium framed window with fire retardant seals The specimen comprised an 1194-mm high x 796-mm wide fixed window, mounted into an aluminium Easyscreen frame and mullions with profiles shown in drawing numbered ESY Fire Testing sheets 1 and 2, dated 15 February 2013, by Breezway. A 720-mm wide x 6-mm thick toughened glass was fitted within the window s frame, held in place with PVC Setting Blocks and Foam Tape, on the unexposed face, and a Gap Wedge stated to be made out of 3-430- 026-6FR material, on the exposed face. A nominal 3.2-mm clearance between the glass edges and the clips was maintained along the vertical sides. Bostik Firecaulk was applied on the corners between glass and frame. Along the bottom of the assembly, a Marcott SCE17-27 FR Wheatherseal was installed as shown in drawing numbered ESY Fire Testing sheet 3, dated 15 February 2013, by Breezway. Details of construction are specified in drawings numbered ESY Fire Testing sheets 1 and 3, dated 15 February 2013, by Breezway.

REPORT No. FSZ 1572 Page 6 of 21 Specimen 3: Fire Retardant Stronghold Louvre aluminium framed window including Stronghold Clips The specimen comprised an 1194-mm high x 798-mm wide Altair Louvre window, mounted into an aluminium Easyscreen frame and mullions with profiles shown in drawing numbered ESY Fire Testing sheets 1 and 2, dated 15 February 2013, by Breezway. The adjustable louvre system comprised eight sections of 720-mm long x 152-mm wide x 6-mm thick toughened glass fitted within Stronghold clips. The Stronghold clips, stated to be made of Retpol PDR 9044 UVA copolymer polypropylene compound, were held to the aluminium frame by Stronghold bearings, retainers, pins and stabilisers stated to be made of Acetal. A nominal 3.2-mm clearance between the glass edges and the clips was maintained along the vertical sides. The Low Profile Handle was stated to be made of stainless steel. Along the bottom of the glass window, a Marcott SCE17-27 FR Wheatherseal was installed as shown in drawing numbered ESY Fire Testing sheet 3, dated 15 February 2013, by Breezway. On the exposed face of the window, an 1194-mm high x 800-mm wide x 0.9-mm thick Tensile-Tuff Crimsafe 304 grade stainless steel security mesh was fixed to the aluminium frame by 22-mm Self Drilling Pan Head screws at 300-mm centres. Details of construction are specified in drawings numbered ESY Fire Testing sheets 1 and 3, dated 15 February 2013, by Breezway. Specimen 4: Standard Altair Louvre aluminium framed window including MK2 Clips The specimen comprised a 1194-mm high x 799-mm wide Altair Louvre window, mounted into an aluminium Easyscreen frame and mullions with profiles shown in drawing numbered ESY Fire Testing sheets 1 and 3, dated 15 February 2013, by Breezway. The adjustable louvre system comprised eight sections of 720-mm long x 152-mm wide x 6-mm thick toughened glass fitted within MK2 clips. The MK2 clips, stated to be made of POLYCOMP CA03 UVH copolymer polypropylene compound, were held to the aluminium frame by MK4 bearings, retainers, pins and stabilisers stated to be made of Acetal. A nominal 3.2-mm clearance between the glass edges and the clips was maintained along the vertical sides. The Standard Handle was stated to be made of stainless steel. Along the bottom of the glass window, a Santoprene PVC Wheatherseal was installed as shown in drawing numbered ESY Fire Testing sheet 2, dated 15 February 2013, by Breezway. On the exposed face of the window, an 1194-mm high x 800-mm wide x 0.9-mm thick Tensile-Tuff Crimsafe 304 grade stainless steel security mesh was fixed to the aluminium frame by 22-mm Self Drilling Pan Head screws at 300-mm centres.

REPORT No. FSZ 1572 Page 7 of 21 Details of construction are specified in drawings numbered ESY Fire Testing sheets 1 and 2, dated 15 February 2013, by Breezway. Specimen 5: Fixed Lite aluminium framed window with standard seals The specimen comprised a 1194-mm high x 796-mm wide fixed window, mounted into an aluminium Easyscreen frame and mullions with profiles shown in drawing numbered ESY Fire Testing sheets 1 and 3, dated 15 February 2013, by Breezway. A 720-mm wide x 6-mm thick toughened glass was fitted within the window s frame, held in place with PVC Setting Blocks and Foam Tape, on the unexposed face, and a Gap Wedge made out of Santoprene, on the exposed face. A nominal 3.2-mm clearance between the glass edges and the clips was maintained along the vertical sides. Silicone sealant was applied on the corners between glass and frame. Along the bottom of the glass window, a Santoprene PVC Wheatherseal was installed as shown in drawing numbered ESY Fire Testing sheet 2, dated 15 February 2013, by Breezway. Details of construction are specified in drawings numbered ESY Fire Testing sheets 1 and 2, dated 15 February 2013, by Breezway. Specimen 6: Fire Retardant Stronghold Louvre aluminium framed window including Stronghold Clips The specimen comprised a 1194-mm high x 798-mm wide Altair Louvre window, mounted into an aluminium Easyscreen frame and mullions with profiles shown in drawing numbered ESY Fire Testing sheets 1 and 3, dated 15 February 2013, by Breezway. The adjustable louvre system comprised eight sections of 720-mm long x 152-mm wide x 6-mm thick toughened glass fitted within Stronghold clips and sealed with silicone sealant. The Stronghold clips, stated to be made of POLYCOMP CA03 UVH copolymer polypropylene compound, were held to the aluminium frame by Stronghold bearings, retainers, pins and stabilisers stated to be made of Acetal. A nominal 3.2-mm clearance between the glass edges and the clips was maintained along the vertical sides. The Standard Handle was stated to be made of stainless steel. Along the bottom of the glass window, a Santoprene PVC Wheatherseal was installed as shown in drawing numbered ESY Fire Testing sheet 2, dated 15 February 2013, by Breezway. On the exposed face of the window, an 1194-mm high x 800-mm wide x 0.9-mm thick Tensile-Tuff Crimsafe 304 grade stainless steel security mesh was fixed to the aluminium frame by 22-mm Self Drilling Pan Head screws at 300-mm centres. Details of construction are specified in drawings numbered ESY Fire Testing sheets 1 and 2, dated 15 February 2013, by Breezway.

REPORT No. FSZ 1572 Page 8 of 21 ORIENTATION The glass window assembly was tested with the exterior face exposed to the radiant heat source. CRIB SIZE Crib size selected by the test sponsor was Class A, simulating a debris pile not exceeding 0.12 kg (approximately 150-mm wide x 300-mm deep x 75-mm high). LEVEL OF RADIANT HEAT EXPOSURE Level of radiant heat exposure selected by the test sponsor was Very High 29 kw/m 2. DOCUMENTATION: Drawings numbered ESY Fire Testing sheets 1, 2 and 3, dated 15 February 2013, by Breezway. Confidential information about the test specimen has been submitted and is retained at CSIRO Materials Science and Engineering. EQUIPMENT: FURNACE The furnace had a nominal opening of 3000-mm x 3000-mm for attachment of vertical specimens. The furnace was lined with refractory bricks and materials with the thermal properties as specified in AS 1530.4-2005 and was heated by combustion of a mixture of natural gas and air. TEMPERATURE The temperature in the furnace chamber was measured by eight type K, 3-mm diameter, 310 stainless steel Mineral Insulated Metal Sheathed (MIMS) thermocouples. Each thermocouple was housed in high-nickel steel tubes opened at the exposed end. RADIANT HEAT SOURCE Radiant heat source consisted of a 3-mm thick black steel sheet mounted into a refractory frame in two sections with a vertical joint at its centre. The frame housing the steel sheet, was positioned and sealed up against the front of the furnace aperture. RADIANT HEAT FLUX CALIBRATION Prior to the test, positions of the specimen (relative to the radiant heat source) were established that corresponded to the required radiant heat flux levels.

REPORT No. FSZ 1572 Page 9 of 21 Radiation distribution was also established by measuring radiant heat flux levels at the centre and the centre of each quarter section of the specimen in a plane approximating to the intended position of the specimen such that the central value will be approximately equal to the rest of the radiant heat flux. MEASUREMENT SYSTEM The primary measurement system comprised of multiple-channel data loggers, scanning at two seconds intervals during the test. AMBIENT TEMPERATURE: The temperature of the test area was 22 C at the co mmencement of the test. TERMINATION OF TEST: The test was terminated at 60 minutes. TEST RESULTS: CRITICAL OBSERVATIONS The following observations were made during the fire test: 0 minutes - Alight cribs placed in position. 20 seconds - Specimen moved in position exposure to 29 kw/m 2. 1:20 minutes - Seals on exposed face are burning along the bottom of exposed face. 2:00 minutes - Seals are melting along the bottom of Specimen 2 (Photograph 4). 2:20 minutes - Specimen moved in position exposure to 21 kw/m 2. 3:00 minutes - Seal along the bottom of Specimen 2 ceased burning. 3:20 minutes - Specimen moved in position exposure to 14 kw/m 2. 4:20 minutes - Specimen moved in position exposure to 11 kw/m 2. 5:00 minutes - No change to the unexposed face of the specimens. 5:20 minutes - Specimen moved in position exposure to 8 kw/m 2. 6:00 minutes - Bottom crib has ceased flaming crib is glowing. 6:20 minutes - Reduced temperature on the furnace exposure to 6.5 kw/m 2. 7:30 minutes - Turned the furnace off exposure to 5 kw/m 2. 8:20 minutes - Exposure to 3.5 kw/m 2. 9:00 minutes - Top crib has ceased flaming crib is glowing. 9:20 minutes - Exposure to 3 kw/m 2. 10 minutes - Crib has ceased burning. 15 minutes - Radiant heat source shielded.

REPORT No. FSZ 1572 Page 10 of 21 16 minutes - Radiometer moved into position - 250-mm from the exposed face. 20 minutes - Pilot flame applied - no ignition is observed. 40 minutes - Pilot flame applied - no ignition is observed. 50 minutes - Pilot flame applied - no ignition is observed. 60 minutes - Test terminated - no flaming is observed. RADIANT HEAT FLUX Figure 1 shows the curves of target and incident radiation versus time and the actual curves of received radiation at 365-mm from the unexposed face and 250-mm from the exposed face versus time recorded during the test period. Figure 2 shows the curve of received radiation versus time at 365-mm from the unexposed face of the specimen. Figure 3 shows the curve of received radiation versus time at 250-mm from the exposed face of the specimen. PERFORMANCE Performance observed in respect of Clause 14.4 of AS1530.8.1-2007 criteria for all the specimens: Performance Criteria Time to failure (min) Position of failure Formation of through gaps greater No failure - than 3-mm Sustained flaming for 10 seconds on No failure - the non-fire side Flaming on the fire-exposed side at No failure - the end of the 60 minutes test period Radiant heat flux 365-mm from the No failure - non-fire side exceeding 15 kw/m 2 Mean and maximum temperature Not applicable - rises greater than 140 K and 180 K Radiant heat flux 250-mm from the No failure - specimen, greater than 3 kw/m 2 between 20 minutes and 60 minutes Mean and maximum temperature of internal faces exceeding 250ºC and 300ºC respectively between 20 minutes and 60 minutes after commencement of test Not applicable - Crib class A Peak heat flux 29 kw/m²

REPORT No. FSZ 1572 Page 11 of 21 For the purpose of building regulations in Australia, the test specimen achieved a Bushfire Attack Level (BAL) of A29. This report details methods of construction, the test conditions and the results obtained when the specific element of construction described herein was tested in accordance with test method of AS 1530.8.1. TESTED BY: Mario Lara Testing Officer for Garry E Collins Manager, Fire Testing and Assessments 22 February 2013

REPORT No. FSZ 1572 Page 12 of 21 APPENDICES APPENDIX 1 Photograph 1 - Exposed face of the specimen prior to testing Photograph 2 - Unexposed face of the specimen prior to testing

REPORT No. FSZ 1572 Page 13 of 21 Photograph 3 - Specimen at the start of the testing Photograph 4 - Specimen 2 at 2 minutes into the test

REPORT No. FSZ 1572 Page 14 of 21 Photograph 5 - Exposed face of the specimen at 17 minutes into the test Photograph 6 - Unexposed face of the specimen at the completion of testing

REPORT No. FSZ 1572 Page 15 of 21 Photograph 7 - Exposed face of the specimen at the completion of testing

REPORT No. FSZ 1572 Page 16 of 21 APPENDIX 2 30 25 20 15 10 5 0 0:00:00 0:02:53 0:05:46 0:08:38 0:11:31 0:14:24 0:17:17 0:20:10 0:23:02 0:25:55 0:28:48 Time (hr:min:sec) 365-mm from the unexposed face Calculated radiation @ the centre of the specimen 250-mm from the exposed face Target @ centre Radiant Heat Flux (kw/m 2 ) Figure 1 - Radiant Heat Flux

REPORT No. FSZ 1572 Page 17 of 21 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0:00:00 0:01:26 0:02:53 0:04:19 0:05:46 0:07:12 0:08:38 0:10:05 Time (hr:min:sec) 365-mm from the unexposed face Radiant Heat Flux (kw/m 2 ) Figure 2 - Radiant Heat Flux received @ 365-mm from the unexposed face

REPORT No. FSZ 1572 Page 18 of 21 0.3 0.2 0.1 0 0:17:17 0:24:55 0:32:33 0:40:11 0:47:48 0:55:26 1:03:04 Time (hr:min:sec) 250-mm from the exposed face Radiant Heat Flux (kw/m 2 ) Figure 3 - Radiant Heat Flux received @ 250-mm from the exposed face

REPORT No. FSZ 1572 Page 19 of 21 APPENDIX 3 Drawing numbered EZY Fire Testing sheet 1, dated 15 February 2013, by Breezway

REPORT No. FSZ 1572 Page 20 of 21 Drawing numbered EZY Fire Testing sheet 2, dated 15 February 2013, by Breezway

REPORT No. FSZ 1572 Page 21 of 21 Drawing numbered EZY Fire Testing sheet 3, dated 15 February 2013, by Breezway