MAINTAINING THE CLIMATE FOR GROWTH. catalog 26

Similar documents
Because you want reliability, versatility, and value in one complete electronic control package

Procom Greenhouse Control System

Growmaster Procom Precision Control, Multiple Zone Capability, Easy Operation

TPR. Features: TALL PLANT

Feature Summary. I. System

Air Resource Specialists, Inc.

Centro-Matic Automated Lubrication Systems System Controls

FDF Foam Pump Controllers Features

Modular Supply Make-Up Air Unit

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Section PERIMETER SECURITY SYSTEMS

AS950 REFRIGERATED SAMPLERS

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Coe Press Equipment Corporation. Power Straighteners. Coe Press Equipment Corporation. The Company That Feeds an Industry

Custom Duct Heaters. Special Applications

INSTALLATION & USER MANUAL

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Forever Flowering Greenhouse Suggested Setup Wiring Diagrams

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

TCR. Features: TISSUE CULTURE

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

"ESDDR" Series Electric Humidifier

csw-200 intro d u c t i o n

TCC-34. Features: TISSUE CULTURE

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

MICRO GROW. GREENHOUSE SYSTEMS, INC ZEVO DR., UNIT B-1, TEMECULA, CA PHONE (951) FAX (951)

Soft Start Series MP700 Solid State, Reduced Voltage

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AIR HANDLER SPECIFICATION

Custom Duct Heaters. Special Applications

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

MacroAir AirElite HVLS Fans

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Direct Fired Heater Model AD Specification

SENTRA Series Water Unit

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

wireless. web-based. worthy of the name RACO.

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

ES2 Boiler 85% AFUE. Limited Lifetime Warranty! boiler control. option. option card. control system GREATER ENERGY SAVINGS. Cast Iron Water Boiler

OPI-integris Advantages

High Efficiency Commercial Gas Water Heaters

MacroAir AirSpan HVLS Fans

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Oakton TEMP 9500 Advanced Multiparameter Controller

Indirect Gas-Fired Make-Up Air

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

Air-Cooled Condensing Units with Compact Screw Compressors

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Distributed By: M&M Control Service, Inc Building Technologies

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

AS950 PORTABLE SAMPLERS

Across-the-Line SERIES MP300 Combined Manual and Automatic

AccuBrine automated brine maker Technical Specifications

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

SECTION HUMIDITY CONTROL EQUIPMENT

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

15900 HVAC INSTRUMENTATION AND CONTROLS

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

CP CP

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Power Flame Incorporated

PARAGON Commercial Refrigeration Controls

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Competitor Series Dryers

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

900MAX PORTABLE SAMPLERS

Variable Frequency Drive SERIES MP800 VFD

Electrical Specifications

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Direct Gas-Fired Make-Up Air

SPC-56 SHORT PLANT.

Description. Construction

LMR Electric Fire Pump Controllers Features

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

E340 BOILER CONTROL INSTALLATION MANUAL

Tightening Up Greenhouse Energy Efficiency

CHECKFIRE 210 Detection and Actuation System

FOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30,

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

KUH. Horizontal Unit Heater. Applications. Description

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Chore-Time Fan Guide For Tunnel and Other Applications

Revitalize Building Mechanical Systems (4619)

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Transfer Switch Features

Transcription:

MAINTAINING THE CLIMATE FOR GROWTH catalog 26

6 STEPS Single,Total Environmental Program Wadsworth knows that no one control is right for everyone, that is why we make 6 models of STEP controls. Our climate controllers ensure the equipment in your greenhouse works together. They operate the right amount of equipment to maintain the climate for growth. All of our controls are easy to use - designed to make your job easier, not more complicated. All of our STEP controls: improve crop quality reduce operational costs reduce energy bills provide labor savings allow you to consistently reproduce top results With Wadsworth s track record for reliability and technical support since 1952 it s no wonder that we re the leader in environmental controls. 36 STEP Controls

Computerized STEP Controls Our entire line of computerized STEP controls are easy to use with a menu driven program where all you need to do is make selections from the items listed on the menu. Any setpoint changes, calibrations, reconfigurations, etc. can easily be done. Every feature of each of our computers is designed and refined in response to the grower. Our controls are self-contained, needing no other computer to operate. The optional STEPsaver soft ware links the greenhouse computers to a personal computer for record keeping, monitoring or changes to any equipment settings. Also, when connected to the internet, we are able to provide remote technical support and training. Wadsworth's 52 years of experience and 18+ years in selling and supporting greenhouse computers are at your service. VersiSTEP Wadsworth s VersiSTEP is the newest product in our line of STEP controls. This fully integrated computer provides 24 outputs with multi-zone control. If your application calls for more than just the basic VersiSTEP, add the optional expansion unit and get 16 more controlled outputs without the cost of a second computer. (See next page.) Also combine the VersiSTEP with the EnviroSTEP and microstep/sa controls on a single network that economically puts control power where you need it in the greenhouse. The VersiSTEP s 24 relay outputs operate most any greenhouse equipment system. Heating, cooling, light level, CO 2 concentration and watering are all at your fingertips. Features: Multi-zone control allowing management over several environments. NEMA 4 cabinet - aluminum 32" x 24" x 5" (813 x 610 x 127mm) with locking door, protects against sunlight and moisture in the greenhouse environment. 3 setpoint periods: day, night and DIF plus programmable ramp rates for full control. 24 relay outputs with the ability to add 16 additional outputs all with manual override switches. Replaceable 10 amp DPDT relays. 4 analog outputs (0 to 10VDC) to control variable speed fans and modulating valves. 32 analog input channels for connecting light, CO 2, RH, and temperature sensors. 8 digital detector input channels for connection of precipitation detector, wind speed, wind direction, flame failure on a boiler, generator or other equipment or devices you may want to monitor. Records the status of all inputs and outputs in 15 minute increments. Alarm outputs: relay with programmable temperature & RH thresholds, plus power failure. Includes aspirated temperature and humidity sensing module with 100 of cable and a solar-shielded outdoor temperature sensor with 25' of cable. Fahrenheit or Centigrade selectable. Largest graphical display in the industry: 8 lines, includes graphing functions. 4X4 keypad to allow for easy programming. Add the STEPsaver package for Windows for more powerful data storage, reporting, and monitoring from your PC. Add a Weather Station for more sophisticated control and vent protection. (see pg. 11) The VersiSTEP can control the majority of equipment in a greenhouse. Each piece of equipment has its own settings. Some parameters include: On/Off temperature settings De-humidification settings Wind speed and direction Light intensity and accumulation Precipitation CO 2 Wadsworth programs the computers with known safe parameters. These conditions are easily changed by the grower to allow for optimum growing conditions for each crop and climate. 4

VersiSTEP Control with Aspirator and outdoor temperature sensor VersiSTEP Satellite provides flexibility with an additional 16 outputs for a VersiSTEP Control. This is an inexpensive way to increase versatility. Example Five Gutter-Connected Houses Two Zone Environments One VersiSTEP Computer 21 Outputs Used Equipment Controlled 4 Open roof vent - ILS 1 Hot water boiler 2 Floor heat 2 Perimeter heat 4 Two-speed fans 2 Evaporative cooler - water pump 4 Energy curtains 2 HID lights VersiSTEP Control: Part #: M-4700 Requires 1amp @ 115 VAC Shipping Wt: 50 lbs. / 22.7 KG Optional Equipment (see pg. 11 for details) STEPsaver Software Part #: M-4900 Weather Station Part #: M-4826 CO2 Sensor Part #: E-1505 Hot Water Sensor Part #: M-4820 Soil Probe Part #: M-4823 VersiSTEP Satellite Part #: M-4710 Shipping Wt: 34 lbs. / 15.4 KG NOTE: The VersiSTEP Satellite DOES NOT function without the VersiSTEP Control. It is only an addition, NOT a self-contained controller. It cannot be used with the EnviroSTEP or the microstep/sa. Features: NEMA 4 cabinet - aluminum 24" x 18" x 5" (610 x 457 x 127mm) with locking door, protects against sunlight and moisture in the greenhouse environment. 16 relay outputs with manual override switches increase the VersiSTEP's capacity to 40 outputs. Replaceable 10 amp DPDT relays. Example One Free Standing House Three Zone Environments One VersiSTEP Computer 39 Outputs Used Equipment Controlled 6 Irrigation valves 3 Gas fired unit heaters 6 Energy curtains 6 Roof ridge vents 3 HAF fans 3 Exhaust fans 6 Side vents 3 Evaporative cooler - water pump 3 HID lights 5Computerized STEP Controls

Computerized STEP Controls EnviroSTEP Wadsworth s EnviroSTEP is a fully integrated computer that controls a single zone. Growers with multiple greenhouses can combine EnviroSTEP, VersiSTEP and microstep/sa computers. With the EnviroSTEP s 12 outputs you can control the majority of equipment in your greenhouse. Control temperature, humidity, energy curtains, lighting, CO 2, irrigation, misting and fog. The EnviroSTEP is self-contained and does not need a Personal Computer to operate. The optional STEPsaver software program connects an EnviroSTEP to a PC allowing the grower to manage current conditions, monitor controls and make changes to the set points or address alarms from a remote location. Features: 3 set point periods: Day, Night and DIF plus programmable ramp rates for full control. 12 relay outputs with manual override switches. Replaceable 10 amp DPDT relays. 2 analog outputs (0 to 10VDC) control variable speed fans and modulating valves. 7 Analog input channels connect light, CO 2, RH, and temperature sensors. 4 digital detector input channels read precipitation, wind speed/direction sensors. Records all input and output status in 15 minute increments. Alarm outputs with programmable thresholds. Includes aspirated temperature and humidity sensing module with 100 of cable and a solar-shielded outdoor temperature sensor. Fahrenheit or Centigrade selectable. Industry s largest display screen with 8 lines, includes report logs and graphing functions. 4X4 keypad for easy programming. Anodized aluminum cabinet 16 x 16 x 5 (406 x 406 x 127mm) with locking door, protects against sunlight and moisture. For maximum benefit, connect your EnviroSTEP to a Weather Station and use the STEPsaver software to connect to a PC. The EnviroSTEP can control the majority of equipment in a greenhouse. Each piece of equipment has its own settings. Some parameters include: On/Off temperature settings De-humidification settings Wind speed and direction Light intensity and accumulation Precipitation CO 2 Wadsworth programs the computers with known safe parameters. These conditions are easily changed by the grower to allow for optimum growing conditions for each crop and climate. Example Five Gutter-Connected Houses One Zone Environment One EnviroSTEP Computer 12 Outputs Used Equipment Controlled 1 1st bank of 5 unit heaters 1 2nd bank of 5 unit heaters 1 HAF fans 2 Roof vents 1 LST Master Vent Control & four 2R slave units 2 Sidewall curtains 2 Gable end curtains 1 50 HID grow lights 2 Energy curtain 6

Example One Free Standing House One Zone Environment One EnviroSTEP Computer 12 Outputs Used EnviroSTEP Control with Aspirator and outdoor temperature sensor Equipment Controlled 1 Hot water boiler / floor heat 1 Hot water perimeter heat / fin pipe 1 Hot water under bench heat 1 HAF fans 2 Roof vent 1 LST Master Vent Control 1 Evaporative coolers - Low Speed 1 Evaporative coolers - High Speed 1 Evaporative cooler - water pump 1 Misting system 2 Energy curtain EnviroSTEP Control: Part #: M-4840 Requires 1amp @ 115 VAC Shipping Wt: 28 lbs. / 13 KG Optional Equipment (see pg. 11 for details) STEPsaver Software Part #: M-4900 Weather Station Part #: M-4825 CO 2 Sensor Part #: E-1505 Hot Water Sensor Part #: M-4820 Soil Probe Part #: M-4823 7EnviroSTEP

Optimize the Power Integrate your EnviroSTEP, microstep/sa and VersiSTEP with your PC Wadsworth Control Systems, Inc. Introduces the We are proud to introduce our new STEPsaver software for use with Wadsworth s EnviroSTEP, microstep/sa or VersiSTEP greenhouse computers. STEPsaver - saves growers steps in going out to the control. Using the software takes fewer steps to do the same tasks, and the software saves data from the computerized STEP controls to your PC. STEPsaver is ideally suited for any size grower. Combining performance with outstanding value, the easy to use STEPsaver software enables speedier access and analysis to maximize growers ability to control their crops. Replicate previous best practices. Ideal for those who grow seasonal crops like poinsettias or lilies, the STEPsaver software can capture and save snapshot images of all the settings. When it s time to plant that crop again, recreate that exact environment by sending the image of your settings back to the EnviroSTEP, VersiSTEP or microstep/sa. No more tedious notes on the settings just a simple click of the mouse. STEPsaver features: Easy to use Windows interface. Centralized view of conditions, settings, and records from all of your EnviroSTEP, microstep/sa and VersiSTEP controllers. Investigate and address alarms. 2.0 Monitor, Analyze, and Direct Your Entire Greenhouse Range from Your Windows PC 2.0 STEPsaver Software Shipping Wt. 2 lbs. / (1 KG) Part#M-4900 Saves STEP control information. Automatically gathers and archives climate records off of your greenhouse computer for permanent PC storage. Advanced data logging and graphing of sensors and greenhouse equipment. Analyze climate data, equipment operation, and performance within STEPsaver, or export the information for use with other programs. Share data on networked PCs. System Requirements: Operating System: Windows XP, Windows 2000 or Windows 98 second edition CD-ROM Drive 450 MHZ processor or higher 512 MB RAM 300 MB of available disk space Internet Explorer 6.0 or higher STEPsaver works with all EnviroSTEP, VersiSTEP and post-1995 microstep controls. Upgrades available for microsteps made before 1995. Full password and rights protection allows different levels of access. Assign meaningful zone names like Perennials, Research Range or Propagation House. 2.0 10

Optimize the power of your EnviroSTEP, VersiSTEP and microstep/sa computer controls with additional sensors Increase the power of your greenhouse computer by using additional sensors. Wadsworth provides C0 2, light, soil temperature sensors and a weather station which monitors the outdoor conditions. All of this additional information adds depth to the computer program. Computer Weather Station Wadsworth s weather station monitors the following outdoor weather conditions: Temperature Humidity Wind speed and direction Precipitation Light intensity Accumulated light Optimize the Power Wadsworth s aspirators provide accurate greenhouse temperature readings. Sensors are inside a protective module which prevents direct sunlight exposure. The aspirator has a fan that draws the air through, providing an actual ambient temperature reading, rather than radiant temperature. EnviroSTEP, VersiSTEP and microstep/sa Aspirators and Sensors Computer aspirators with temperature and humidity sensors Part#M-4821 Shipping wt. 3 lbs. / 1.4 KG Part#G-0400 Hookup cable for M-4821 aspirator Computer aspirator with temperature sensor only Part#M-4822 Shipping wt. 3 lbs. / 1.4 KG Part#G-0406 Hookup cable for M-4822 aspirator Computer soil temperature probe, stainless steel Part#M-4823 Shipping wt. 1 lbs. / 0.5 KG Computer CO 2 sensor Part#E-1505 Shipping wt. 3 lbs. / 1.4 KG Computer light sensor (Pyranometer) Part#D-1326 Shipping wt. 1 lbs. / 0.5 KG Computer Weather Station E-STEP: Part # M-4825 V-STEP: Part # M-4826 M-STEP: Part # M-4826 Shipping wt. 90 lbs. / 41 KG Computer hot water sensor Part#M-4820 Shipping wt. 2 lbs. / 1 KG 11

STEP Automation STEP Automation Wadsworth s STEP 50A and STEP 500 control systems make greenhouse temperature control easy. Just connect your heating and cooling equipment and turn the knobs to the desired day and night temperatures. No more dueling thermostats that have cooling systems and heaters running at the same time. Incredible durability: some Wadsworth controls purchased in the 1970's are still effectively controlling environments today. Heat 3 HAF/JET fans on Perimeter heat on Under bench heat on Gas unit haters on Heat 2 HAF/JET fans on Perimeter heat on Under bench heat on Heat 1 HAF/JET fans on Perimeter heat on 65.5º SET POINT Ideal temperature HAF/JET fans on to circulate air THROTTLING RANGE 67 68.5º 70º 71.5º 73º 74.5º 76 77.5º AC-1 HAF/JET fans on Motorized louvers open 2 speed fan on low AC-2 HAF/JET fans on Motorized louvers open Vent 1/4 open 2 speed fan on low AC-3 HAF/JET fans off Motorized louvers closed Vent 1/2 open 1 speed fan on 2 speed fan on low AC-4 Vent full open 1 speed fan on 2 speed fan high AC-5 Vent full open 1 speed fan on 2 speed fan high Pad pump on 12

STEP Up to increased control! STEP Up TO INCREASED EFFICIENCY: Reduce your labor costs with the STEP Up automatically controling your environment. Wadsworth custom programs your control based on the equipment in your greenhouse. Leaving time for you to focus on running your business. STEP Up TO ENERGY CONSUMPTION: Using a sensitive, central temperature sensor housed in an aspirated solar guarded housing reduces your energy consumption. STEP Up TO EASY OPERATION: It s as simple as turning a knob and pressing the select/save button. STEP Up TO INCREASED FLEXIBILITY: You can easily change your three set point temperature settings and adjust the temperature between each stage. STEP Up TO EXPANDED OPERATIONS: STEP Up automatically operates the equipment. In addition you can manually override the equipment based on time or use the manual toggle switches. Use the timed override to lock out cooling during fumigation. STEP Up TO IMPROVED CROPS: Improve your crop quality by using the temperature data. STEP Up records 7 days of data in 15 minute intervals. It records the minimum/maximum/ average temperature for each period and graphs the data on the LCD screen. Mary, I change the text w/ this bullet STEP Up TO A SAFER SYSTEM: Battery backup retains your custom settings, the time and date. Manual toggle switches give you full control Connect to Wadsworth s Alarm Manager to be notified of urgent conditions. STEP Up TO AN ENHANCED DISPLAY: The front panel features a large LCD screen and oversized font displays current temperature, time, date and grow weeks. Red LED lights indicate currently active stages.

STEP Up CONTROL FEATURES: 6 Stages 2 Stages of Heating 4 Stages of Cooling Easy to adjust the temperature between stages. 2 Incremental outputs modulate vents, side roll-up or curtains. Easy adjustment of temperatures between stages. 3 Setpoint Periods Day/Night/DIF set points Ramping controls the rate of change between periods Periods can be set based on clock time or sunrise and sunset. Tracks grow weeks Modulating Output 0 10 volts or 4-20 milliamps Controls Heat Valves or Variable Speed Fans Cycle Timer Password protected Manual Override Timed override buttons on the STEP Up control allow equipment to be forced on or off for a specific duration. Red LED indicate active stages Manual override toggle switches are on the contactor panel Logs and Graphs Data Average, high and low temperature for each setpoint time period Average temperature in 15 minute increments Data is stored on the STEP Up for 7 days and can be viewed in logs or graphs STEPsaver software connects your STEP Up to a PC advanced data logging and graphing Settings are stored in memory in the event of power failure. Fahrenheit/Celsius selectable Alarm notification with optional Alarm Manager On-line Help Provides additional information Ability to return to factory settings STEP Up Control Includes An aspirated temperature sensor and 100 of cable Optional RH sensor Connector cable to wire the STEP Up control to the contactor panel Length = 9-1/2", Width = 3-3/4", Height = 6-1/4" 1.800.821.5829 www.wadsworthcontrols.com

MiniSTEP The MiniSTEP is a temperature controller designed specifically for a freestanding hoop greenhouse with a 2-speed fan and a high gable louver. The MiniSTEP is an economically priced all inclusive package. It includes: MiniSTEP 4 stage electronic control. A pre-wired contactor panel. Blueprints, control schematics, one-line power, conduit and wiring layouts for installation. Solar-shielded temperature sensor with 75 of shielded cable. The MiniSTEP is easy to install and operate. The heating and cooling stages are already set. If you want to change the temperatures it s as easy as pushing a few buttons. Features Voltage Input: 120 VAC, 50 / 60 Hz. One temperature setting. Four output stages. Adjustable temperature, mode and output status. LCD display of current temperature, mode and output status. Keypad provides easy programming and operation. Fahrenheit or Celsius scale. Benefits: Uniform plant growth. Reduces fuel costs. Increases productivity. Simplifies control and maintenance. The MiniSTEP is programmed with one heat and three cooling outputs. It can control the following: 1-2 gas fired unit heaters on one stage. 1 two speed exhaust fan (required). 1 single speed exhaust fan. 1 high gable louver (required). Pad shutters with LST vent control. Pad pump. Fan jet or HAF fans. MiniSTEP TM Part #: M-4000 Requires 1 amp @ 115 VAC Shipping Wt. 37 lbs. / 17KG Example One Free-Standing Hoop House One Environment One MiniSTEP Control Stages Heat stage Set point AC 1 Equipment status - Gas fired unit heaters on (1-2 heaters) - HAF fans on - HAF fans on - HAF fans on - Upper gable louver open - Two speed exhaust fan on low AC 2 - Side vent or motorized shutters open - LST vent control - Upper gable louver closes - Two speed exhaust fan on high - HAF fans off AC 3 - Single speed exhaust fan on - Evaporative pad pump on - Side vent open - Two speed fan on high 15

The WeatherGuard takes the worry out of wind, rain and snow. It is designed to override normal operations to close vents or retract shade systems when high winds, cold weather, rain or snow might cause damage. The WeatherGuard monitors: Wind speed Wind direction Outdoor temperature Precipitation Provides Protection: Windward vents close in high winds allowing leeward vents to stay open. Vents are protected from cold temperatures and precipitation. Outdoor shades can be retracted in high winds or if there is precipitation. Indoor shades uncover and gutter heaters are turned on to protect the structure from snow damage. The WeatherGuard integrates with existing vent machines and temperature controllers such as the STEP 50A. This system has its own microprocessor which sends an override signal directly to your equipment. If you have a computerized control, such as an EnviroSTEP, use the Weather Station (see pg. 11). WeatherGuard features: Easy to program. Displays weather status. Controls 10 vent machines. Weather instruments on a 22 mast. 100 of cable to connect the control panel to the instruments. Control comes in a sturdy anodized aluminum cabinet. Override Protection Weather Guard Control Part# M-4835 Shipping weight: 110 lbs. / 50 KG Dimensions: Control Panel, 16 H x 16 W x 5 D 19 lbs. / 8.6 KG Mast, 22 H x 2 x 2 45 lbs. / 20.4 KG Mast Tee: 35 x 4 x 2 46 lbs. / 21 KG 17

Integrated Vent Automation Integrated Vent Systems Wadsworth Control Systems is your complete source for vent automation. We know that growers want an integrated vent system that ensures quality in every part and that s why we provide: Gear motors that are stong, durable and long lasting. Vent controls that work with any environmental control system from a thermostat to a state of the art computer like our EnviroSTEP. Strong, corrosion free racks with precision cut teeth. Zinc pinion gears with precise spacing and an outer raised shoulder that extends the life of the rack & pinion. Wide housing that allows racks to work even when the rack is not perfectly aligned. Universal shaft hangers made of rugged 12-guage galvanized steel complete with nylatron bushings. Side/End Gable Overview Mounted PowerRack Vent Panel Universal Shaft Hanger see pg. 22 Vent Machine (VC-2000 shown) see pg. 19 Straight PowerRack Rack & Pinion Vent Opener see pg. 22 & 23 Drive Shaft Coupling S-9109 (1 3/8 Shaft) H-2122 (1 5/8 Shaft) Vent control (VC-2000 ILS/LST shown) see pg. 20 & 21 18

4 steps to selecting the right vent automation system: 1. What size gear motor do you need to lift the vent? 2. What shaft size? 3. What type of vent control? 4. What length of rack? 1 - What size gear motor do you need to lift the vent? VC-100A MOTOR 1/20 Horsepower - T.E.N.V. 115 Volt - 60 Hz. -.68 amp. Ball bearing motor Copper windings insulation class B Thermal overload protection - automatic reset Quick reversing 1600 R.P.M. Continuous Duty Lifts up to 75 of 4 polycarb roof ridge vent VC-100A GEAR-REDUCER Adjustable torque limit switch assembly Output torque 500 in. lb. / 56 Nm Total ratio 1900:1 final output.84 R.P.M. Output gear reducer: worm gear with tapered roller bearing on output shaft immersed in synthetic grease Dual output shaft VC-2000 MOTOR 1/5 Horsepower - T.E.F.C. 115 Volt - 60 Hz. - 2.5 amp. Ball bearing motor Thermal overload protection - automatic reset Quick reversing 1600 R.P.M. Continuous Duty Lifts up to 325 of 54 polycarb roof ridge vent VC-2000 GEAR-REDUCER Adjustable torque limit switch assembly Output torque 1500 in. lb. / 169 Nm Total ratio 1350:1 final output 1.2 R.P.M. Output gear reducer: worm gear with tapered roller bearing on output shaft immersed in synthetic grease Dual output shaft Selecting Vent Automation Why do growers and installers prefer our gear motors? Wadsworth vent systems offer simplicity in design, installation and operation. Easy to install Only 2 wires to reverse direction Powerful, Reliable, Durable Maintenance free Synthetic grease lasts the life of the unit Safety features Reverse torque Over-torque protection stops the motor in case of mechanical binding that could damage your vent. Limit Assemblies stop the motor in normal operation when it is fully open or fully closed. 2 - What shaft size? To determine shaft size, measure the outer diameter of the shaft. VC100A drive unit shown 19

Vent Motors 3 - What type of vent control? I Incremental Opens in increments, closed, 1/4, 1/2 and full open. This is a master control. If placed in the center it can have six 2R units, 3 on each side. Primarily used with STEP50, STEP500, M-1608 or thermostats. It can be used with a computer control, like the EnviroSTEP and it will open in proportions. The computer overrides the Incremental control command. Growers who are upgrading to a computer control can use existing incremental vent controls, but if ordering a new vent automation system, order the LST control with computers. External limit switches. Part #M-1080 VC-100A /I 1-3/8 shaft Shipping Wt. 56 lbs. (25.4 KG) Part #M-1085 VC-100A /I 1-5/8 shaft Shipping Wt. 56 lbs. (25.4 KG) Part #M-1180 VC-2000/I 1-3/8 shaft Shipping Wt. 80 lbs. (36.3 KG) VC100A/I Part #M-1185 VC-2000/I 1-5/8 shaft Shipping Wt. 80 lbs. (36.3 KG) LST Limit Switch with Transformer Opens proportionally with a computerized control. This is a master control. If placed in the center it can have six 2R units, 3 on each side. Primarily used with EnviroSTEP, VersiSTEP and microstep/sa computer controls. It can be used with any computer control for proportional vent movement. It is used with the MiniSTEP to move vents from full open to full closed. If used with a STEP 50, STEP 500, 4-stage control or thermostat it does not open in increments it moves from full open to full close. External limit switches. VC2000 LST Part #M-1140 VC-2000 LST 1-3/8 shaft Shipping Wt. 78 lbs. (35.4 KG) Part #M-1145 VC-2000 LST 1-5/8 shaft Shipping Wt. 78 lbs. (35.4 KG) Part #M-1040 VC-100A LST 1-3/8 shaft Shipping Wt. 54 lbs. (24.5 KG) Part #M-1045 VC-100A LST 1-5/8 shaft Shipping Wt. 54 lbs. (24.5) KG 2R slave unit Used with a master control movement follows the master unit. Used with the Incremental control it opens in increments: closed, 1/4, 1/2 and full open. Used with the LST control it opens proportionally, following the master unit. If the master control is placed in the center it can have six 2R units, 3 on each side. External limit switches. Part #M-1130 VC-200 0/2R 1-3/8 shaft Shipping Wt. 74 lbs. (33.6) KG Part #M-1135 VC-2000/2R 1-5/8 shaft Shipping Wt. 74 lbs. (33.6) KG Part #M-1030 VC-100A/2R 1-3/8 shaft Shipping Wt. 52 lbs. (23.6) KG Part #M-1035 VC-10 0A/2R 1-5/8 shaft Shipping Wt. 52 lbs. (23.6) KG 20

ILS / LST Internal Limit Switch Limit Switch with Transformer Opens proportionally when used with a computerized control. This is a master control, if placed in the center it can have six ILS/2R units, 3 on each side. Primarily used with EnviroSTEP, VersiSTEP and microstep/sa computer controls. It can be used with any computer control for proportional movement VC2000ILS/LST Vent Controls It is used with the MiniSTEP to move vents from full open to full closed If used with a STEP 50, STEP 500, 4-stage Control or thermostat it does not open in increments, it moves from full open to full close. Part #M-1042 VC-100A/ ILS/ LST 1-3/8 shaft Shipping Wt. 70 lbs. ( 31.8 KG) Part #M-1047 VC-100A/ ILS/ LST 1-5/8 shaft Shipping Wt. 70 lbs. (31.8 KG) Part #M-1142 VC-2000/ ILS/ LST 1-3/8 shaft Shipping Wt. 86 lbs. (39 KG) Part #M-1147 VC-200 0/ ILS/ LST 1-5/8 shaft Shipping Wt. 86 lbs. (39 KG) ILS / 2R Internal limit switch slave unit Used with an ILS/LST master control movement follows the master unit and opens proportionally. If the master control is placed in the center it can have six 2R units, 3 on each side. Internal limit switches. VC100A/ILS/2R Part #M-1032 VC-10 0A/ ILS/ 2R 1-3/8 shaft Shipping Wt. 68 lbs. (30.8 KG) Part #M-1037 VC-100A/ ILS/ 2R 1-5/8 shaft Shipping Wt. 68 lbs. (30.8 KG) Part #M-1132 VC-2000/ ILS/ 2R 1-3/8 shaft Shipping Wt. 84 lbs. (38 KG) Part #M-1137 VC-2000/ ILS/ 2R 1-5/8 shaft Shipping Wt. 84 lbs. (38 KG) 21

PowerRack & Pinion 4 - What length of rack? PowerRack RACK & PINION vent opener Unrivaled quality that makes a difference The PowerRack is built to operate your vents reliably, so you can concentrate on growing. When choosing which rack and pinion consider reliability and savings on maintenance costs. Virtually maintenance free, the PowerRack is a solid, reliable unit. Features: Zinc pinion gear with shoulders to bear the weight, extending the life of the gear. Easy alignment: Rack works even when the vent is not perfectly square. Wide housing allows for the inevitable movement in the vents. This unique design prevents binding. Freedom from corrosion: Stainless clevis pins, cotter pins, set screws, cast sash brackets and tough nylatron bearings. Precision cut teeth on the PowerRack arms minimize sharp edges and assure smooth operation. Holes in the pinion housing are punched with a stamping tool to maintain exact spacing. The PowerRack arm and housing is manufactured from aluminum alloy for strength and freedom from corrosion. Wide load-bearing surfaces Replaceable parts Economically priced Straight PowerRack Models Length Shaft Shipping Weight Part # 18 1-3/8 1.25 lbs. / 0.6 KG M-2618 18 1-5/8 1.25 lbs. / 0.6 KG M-2718 28 1-3/8 2.10 lbs. / 0.95 KG M-2628 28 1-5/8 2.10 lbs. / 0.95 KG M-2728 36 1-3/8 2.40 lbs. / 1.09 KG M-2636 36 1-5/8 2.40 lbs. / 1.09 KG M-2736 42 1-3/8 2.50 lbs. / 1.13 KG M-2642 42 1-5/8 2.50 lbs. / 1.13 KG M-2742 48 1-3/8 2.55 lbs. / 1.16 KG M-2648 48 1-5/8 2.55 lbs. / 1.16 KG M-2748 53 1-3/8 2.60 lbs. / 1.18 KG M-2653 53 1-5/8 2.60 lbs. / 1.18 KG M-2753 66 1-3/8 2.95 lbs. / 1.34 KG M-2666 66 1-5/8 2.95 lbs. / 1.34 KG M-2766 72 1-3/8 3.10 lbs. / 1.41 KG M-2672 72 1-5/8 3.10 lbs. / 1.41 KG M-2772 UNIVERSAL SHAFT HANGER The universal shaft hanger supports the shaft that drives the PowerRack. Wadsworth s shaft hangers are made of 12-gauge rigid galvanized steel for reliability. They have nylatron bushings that long outlast bronze bushings. Easy mounting with the pre-punched holes and slots for 5/16 and 3/8 diameter U-bolts. Shaft hanger holes and slots will fit 1-3 pipe, as well as square tubing, angle, channel and various other greenhouse members. (U-Bolts not included) All of these details add up to a long life for your vent automation system. 1 3 /8 Shaft hanger 1 5 /8 Shaft hanger Part #S-2806 Shipping Wt. 1.1 lbs. / 0.5 KG Part #S-2808 Shipping Wt. 1.1 lbs. / 0.5 KG Note: All models have 6 of rack movement per revolution of drive shaft. 22

CURVED PowerRack RACK & PINION The curved PowerRack Rack & Pinion is designed to give additional clearance (54 radius) when space is tight. When a straight rack might interfere with a curtain system or aisle this is the ideal solution. CURVED POWERRACK MODELS Length Shaft Shipping Weight Part # 28 1-3/8 2.10 lbs. / 0.95 KG M-2828 28 1-5/8 2.10 lbs. / 0.95 KG M-2928 36 1-3/8 2.40 lbs. / 1.09 KG M-2836 36 1-5/8 2.40 lbs. / 1.09 KG M-2936 42 1-3/8 2.50 lbs. / 1.13 KG M-2842 42 1-5/8 2.50 lbs. / 1.13 KG M-2942 48 1-3/8 2.55 lbs. / 1.16 KG M-2848 48 1-5/8 2.55 lbs. / 1.16 KG M-2948 53 1-3/8 2.60 lbs. / 1.18 KG M-2853 53 1-5/8 2.60 lbs. / 1.18 KG M-2953 66 1-3/8 2.95 lbs. / 1.34 KG M-2866 66 1-5/8 2.95 lbs. / 1.34 KG M-2966 72 1-3/8 3.10 lbs. / 1.41 KG M-2872 72 1-5/8 3.10 lbs. / 1.41 KG M-2972 PowerRack & Pinion RACK AND PINION SASH ADAPTER When replacing rack and pinions on a vent the existing sash brackets are often in good condition, but do not fit the wider rack arms. With this in mind Wadsworth has designed an adapter with 1/4 wide tongue that will fit most older style sash brackets. Made of cast zinc, the adapter slips easily into the end of the rack arm and is held in place with a clevis pin. ROUND & SQUARE U-BOLTS* To determine size, see the illustration below. Part# A B C Pipe Size* H-2489 3/8 x 1-1/2 x 2-1/2 1 H-2491 3/8 x 1-3/4 x 2-3/4 1-1/4 H-2492 3/8 x 2 x 2-5/8 1-1/2 H-2494 3/8 x 2-1/2 x 3-1/8 2 H-2520 3/8 x 1-9/16 x 2-1/2 1-1/2 sq. H-2525 3/8 x 2-1/8 x 3 2 sq. H-2530 3/8 x 2-5/8 x 3-1/2 2-1/2 sq. H-2537 3/8 x 3-1/8 x 4 3 sq. *Other sizes available C C Pinion sash adapter Part #F-0919 Shipping Wt:.316 lbs. /.143 KG B (Round) A B (Square) A 23

PowerPull Powe r Pull Curtain Automation PowerPull system reduces energy costs year round while increasing plant quality and worker comfort. For new construction or retrofitting in existing greenhouses, our systems are durable and flexibly designed for easy installation. Positive drive rack & pinion system no cable to re-tension Glides over stationary stainless steel lines Slow moving system for better management of cold air dump Built-in safety limits Pays for itself - saves 30-40% on energy bills reduces energy consumption Control light level and temperature Heat Retention - Helps maintain uniform temperatures in winter months Shades - Controls light level Cools 10-15º F Controls day length Creates blackout environment Reduces humidity and condensation Improves plant quality, customer & worker comfort Reduces labor costs Easy to maintain Flexible design, easy installation for new construction or retrofitting Durable fabric - resistant to UV, heat and chemicals Three types of truss-to-truss systems: Slope/Flat/Slope Profile (shown) Slope/Slope Profile Flat/Horizontal Profile Increase energy eff iciency in older houses by installing a Powe r Pull Energy curtain 24

It has been proven that a movable energy curtain results in substantial energy savings. But while saving energy is important, so is achieving the maximum possible light transmission. Please refer to this chart for information about light transmission energy savings ratios. Energy Curtaain light transmission energy savings ratios Light Transmission 40% to 45% 50% to 55% 60% to 65% 70% to 75% 80% to 85% 99.9% Energy savings 50% to 52% 55% to 58% 60% to 63% 65% to 68% 70% to 72% 73% to 78% Stated specifications are from the cloth manufacturers. Automated Energy Curtain RACK & PINION CHASSIS ASSEMBLY LEAD EDGE TUBING COMPONENTS INTERMEDIATE TRUSS SECTION OF SYSTEM FABRIC IS SUSPENDED AT GUTTER/EAVE DRIVE UNIT ASSEMBLY 25

PowerPull Components FABRIC CLIP (ALUMINUM) This clip secures fabric to 10 gauge aluminum, galv. steel angle and various other surfaces. Its serrated inner surfaces provide extra holding power to keep it in place. Part #F-0510 Shipping Wt..012 lbs. / 0.005 KG CLOTH HANGER CLIP This nylon clip has the advantage of clamping the supported fabric top and bottom with a broader holding surface than most clips. The circular leg clamps the cable loop and fabric penetrating points together to hold the material firmly. Part #F-0503 Shipping Wt..008 lbs. / 0.004 KG WIRE VISE Engineered for simplicity, the Wadsworth wire vise is easy to use and requires no tools. Made of aluminum, they are lightweight, economical, and rustproof. Available to hold 0.080 stainless steel wire. Part #H-0412 Shipping Wt..028 lbs. / 0.013 KG STAINLESS STEEL WIRE 0.080 stainless steel wire is extremely durable. Fabric glides on top of lines in PowerPull systems. 5000 per roll. Sold in rolls only. Tensile strength: 1800 lbs. Part #G-0220 Shipping Wt. 86 lbs. / 39 KG LEAD EDGE DRIVE LINE BRACKET Attaches lead edge tube to the push tube. Part #S-9145 Shipping Wt..42 lbs. /.19 KG LEAD EDGE FABRIC CLIP Clip secures fabric around 7/8 O.D. lead edge tubing. The extended legs gather fabric as system uncovers. Part #F-0505 Shipping Wt..036 lbs. / 0.016 KG ALUMINUM LEAD EDGE TUBING 7/8 O.D. x 12 Aluminum Tube with continuous groove for locking the lead edge fabric clip in place. Part #G-0121 Shipping Wt. 2.25 lbs. / 1.02 KG LEAD EDGE TUBE COUPLING For splicing 7/8 x 12 aluminum lead edge. Part #F-0952 Shipping Wt..18 lbs. / 0.082 KG LEAD EDGE ADJUSTABLE JOINT ASSEMBLY To create slope/flat/slope profile for 7/8 x 12 aluminum lead edge. Part #S-2817 Shipping Wt..312 lbs. / 0.142 KG U JOINT 1 3/8" OD shaft only.transition from slope to flat on drive shaft or under gutter. Part #S-9110 Shipping Wt. 3.14 lbs. / 1.42 KG 26

CONTACTOR PANEL While Wadsworth STEP controls can operate a wide variety of equipment, (i.e. exhaust fans, fan jets, pad pumps) larger motor loads must first be connected to special purpose relays called motor starters or contactors. If you do not already have motor starters for the motor loads requiring control, you will need to obtain them from your electrician, an electrical supply house, or from Wadsworth. Wadsworth Control Systems is a UL listed manufacturer of industrial control panels. Part #M-5650 (custom made) call for quotation SIX SECOND TO EIGHT MINUTE TIME DELAY MODULE 19 to 240 VAC or DC / 1 amp steady state. Part #E-0350 Shipping Wt. 1 lb. / 0.45 KG CONTACTOR Contactors are available in 24 or 120 VAC control voltages. Part #E-0314 SPDT 120 VAC coil Part #E-0315 DPDT 120 VAC coil Part #E-0314-1 SPDT 24 VAC coil Part #E-0315-1 DPDT 24 VAC coil Shipping Wt. 1 lb. / 0.45 KG Automation Accessories (more models available, please ask) DPDT LOAD RELAY - LY STYLE DPDT contacts have a maximum rating of 10 amps @ 120 VAC. Available in 24 or 120VAC coils. Part #E-0327 24 VAC coil Part #E-0327- A 120 VAC coil Shipping Wt. 1 lb. / 0.45 KG (more models available, please ask) HYDRAULIC VALVE ACTUATOR For two position control of hot water or low pressure steam. Can be controlled by SPDT thermostat or STEPcontrols. Catalog Number M-6504 Valve Size 1/2 Maximum Close-Off Pressure Steam Water PSI 100 35 Shipping Wt. 11 lbs. / 5 KG M-6507 M-6508 3/4 1 55 30 35 30 M-6509 1 1/4 15 15 HYDRAULIC DAMPER ACTUATOR Operates gable damper. Spring return closes damper when power is removed. Mounting hardware kit includes: bracket, crank arm, and connector for 5/16 rod. Damper not included. 10 watts 120 or 24 VAC 50/60 hz @.15 amp Part #E-0703...120VAC Part #E-0704...24VAC Shipping Wt. 5 lbs. / 2.3 KG 27