DaySenseTM. Technical Guide

Similar documents
Stellar. A Product of its Surroundings.

SURE-LITES. LEM PathLinx Series. LED Emergency Lighting

RTC Recessed LED center basket

ArcLine Recessed LED luminaire

RLN Recessed LED luminaire

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

WaveLinx Outdoor Wireless Connected Lighting System

Connected Buildings Sales positioning guide

mini quiet ceiling mini accurus small aperture trimless and flanged recessed fixtures

Navion LED Area, Site and Roadway Luminaire

LumaWatt Pro Wireless Connected Lighting System powered by Enlighted

Connected Buildings Sales positioning guide

WaveLinx Wireless Connected System

PRODUCT GUIDE. Lighting Solutions LED roadway and utility products

H3 3 Recessed Lighting. 3 Ultra Compact Housings and Trims

Metroline LED architectural luminaire

Power. Eaton is a registered trademark. All other trademarks are property of their respective owners.

LuxeScape Collection LED architectural post top and area/site luminaire. Invue

Outdoor Lighting Solutions LED product portfolio. Streetworks

Outdoor Lighting Solutions LED product portfolio. Streetworks

Arbor LED architectural luminaires. Invue

Get connected. Power Light Connect

Lighting solutions Product guide

3 Ultra Compact Housings and Trims. The Latest Dimension in Recessed Lighting

Correctional LED Lighting

Advanced Lighting For Office

Navion TM LED Roadway and Area Luminaire

LHBXD LED Linear High Bay

New LED Product Offerings

Daylighting Control Design and Application Guide

SDL4 LED Strip Diffused Lens

FLEXRAIL2 CONTENTS LINE VOLTAGE TRACK HEADS LOW VOLTAGE TRACK HEADS METAL HALIDE TRACK HEADS COMPACT FLUORESCENT TRACK HEADS FLEXRAIL2 PENDANT

BAS SDL8' LED Strip Diffused Lens

The Bahen Centre for Information Technology. Meeting Room Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

Vive PowPak Fixture Controls

ULTRAVIOLET INDIRECT AIR DISINFECTION

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

PRESCRIPTIVE APPROACH

Dimensions (111mm) (111mm) 3 (76mm)

INDUSTRIAL & WAREHOUSE LIGHTING Application Guide

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

HIGH LUMINOUS EFFICIENCY

Lighting Controls An Introduction and Review

DHL-LP-LED Low Profile LED Linear High/Low Bay

North America Version / Dimming Function. Introduction

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Technical Report One

LED FIXTURE CATALOG. Shining light into the future

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light

lumenalpha downlight Specification Sheet

Product Specifications MaxLumen MRI LED Diffused Lighting

Lighting Existing Conditions and Design Criteria Report

design and application guide Fifth Light Addressable Lighting Controls

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

66 Series 4ft Recessed, Surface or Pendant Mount

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

Hot Water Temperature Maintenance Product Selection and Design Guide

FR-A180 FR-A360. Occupancy detector. Use

Outdoor Stock LED Lighting Lumark HALO Outdoor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

µdim Microwave Sensors User Manual

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies

Lindsey Beane. Executive Summary

How to light a small storage space rabdesign.ca 1

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Catalog # Project. Comments. Prepared by

Overview. The Reading Room

VESICA LINEAR SUSPENDED VES L

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

A Guide for Applicants and Lighting Designers

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Devices for Special Applications

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Product Specifications MaxLumen MRI LED Diffused Lighting

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Balance LC. classroom light control fixture solution. simple to order simple to install simple to use

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Pioneering Petroleum Canopy Lighting Since 1976

SENSA MRE DDM MR

PURSUIT. New image to come. LiNEAR Without LIMiTation PURSUITTM

Light Management Systems: Energy Savings.

The Children s storytelling area

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

P ulse A new linear pendant from Prudential Ltg. that reshapes sinuous o rdinary spaces using the power of inspired design.

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Good-Better-Best LED Retrofit Guide

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

HALO. RA56 LED Very Wide Flood (VWFL) RA56 LED Narrow Flood (NFL) * Non-California Product Only

Tamper & Weather Resistant Receptacles

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Transcription:

DaySenseTM Technical Guide

DaySenseTM Integrated Luminaire Daylight Sensor Save energy and make your environment SMART with a little help from the sun. -35% Energy Savings Potential -Commissioning Not Required -Dimming Control Systems Not Required -'Plug-N-Play' Setup: Install it and it Works -Small, Unobtrusive Sensor Design -Adjustable Light Sensitivity Create a truly smart lighting system by combining DaySense's innovative light-sensing technology with a variety of standard Corelite suspended direct-indirect fl uorescent lighting systems. The beauty of DaySense lies in its combination of technology and simplicity. The DaySense technology conserves energy by sensing a rise in ambient light levels as the result of an infl ux of daylight, and reacts by signaling the luminaire to reduce light output. The end result is lower energy bills and a lighter carbon footprint. The DaySense's simplicity lies in its ease of set-up and installation; just install the luminaire and it works. Expensive and complicated control systems are not required - all of the intelligence is inside. Now that s a pretty SMART ENVIRONMENT. A SMART ENVIRONMENT by CORELITE 2 Corelite Architectural Lighting Products 4675 Holly St. Denver, CO 80216 Phone: (303) 393-1522 Fax: (303) 393-1477 www.corelite.com

How DaySense Works Typical Workday: Without DaySense Sensor In this example, the employee turns on his light at 8:00 am and turns it off at 5:00pm. The work surface is over-illuminated in the middle of the day, rendering the fl uorescent luminaire useless (wasted light) as the work surface is adequately illuminated with sunlight. 80 fc Excess Illumination 45 fc 8:00 am 5:00 pm Typical Workday: With DaySense Sensor In this example, the Corelite Day- Sense technology senses a rise in ambient illumination and dims the luminaire in response. Day- Sense is calibrated to maintain a maximum of 45 footcandles* of fl uorescent light on the work surface. As the daylight increases, fl uorescent light will decrease. The end result is major energy savings. Daysense *Assumptions: Typical room refl ectances, high refl ectance matte fi nish furniture, 8'-10' sensor mounting height. 80 fc Energy / Light Saved with DaySense 45 fc 8:00 am 5:00 pm Corelite Architectural Lighting Products 4675 Holly St. Denver, CO 80216 Phone: (303) 393-1522 Fax: (303) 393-1477 www.corelite.com 3

Sensor Info Sensor Mounting Guidelines In order to optimize the sensor's performance, it is important that the sensor is mounted in accordance with factory recommendations below. *Approximate "cone of sight". Cone will vary dependent on sensor's setting. Warning: Sensor will not perform properly if positioned directly over dark and/or refl ective surfaces. Adjusting the Sensor in the Field The sensor is set at the factory at its mid-point, although, depending on fi eld conditions, the sensor can be manually adjusted in the fi eld to be either more or less sensitive. Sensor sensitivity may be adjusted to be either 3 times greater or 1/3 less than the factory pre-set. Factory Pre-Set At the factory pre-set position, the sensor will maintain a maximum of 45 footcandles of fl uorescent light at its mid-point (assuming optimal room refl ectances and a 8'-10' mounting height). More Sensitive By rotating the sensor clockwise, its sensitivity will increase three fold beyond the factory pre-set. This means LESS FLUORESCENT LIGHT, as well as the greatest energy savings potential. Less Sensitive By rotating the sensor counterclockwise, the dimming function will essentially be disabled. This position will INCREASE THE AMOUNT OF FLUORESCENT LIGHT present on the work surface. 4 Corelite Architectural Lighting Products 4675 Holly St. Denver, CO 80216 Phone: (303) 393-1522 Fax: (303) 393-1477 www.corelite.com

System Modules - Suspended Lighting Sensor Locations - Individual Luminaires It is important to understand that there are limited possible locations for sensors, while also noting the sensor's location with regard to the power feed location. Sensor locations and power feed locations need to be clearly noted in the electrical drawing. a. b. 4 DaySense Standard* f. Standard* c. d. 4 Power Feed 8 8 Standard* g. h. e. i. 8 *Standard sensor location with regard to power feed; consult factory for all other options. Non-standard sensor locations must be clearly noted in electrical drawings. Sensor Locations - Continuous Rows Standard Corelite products may be confi gured into limitless length, lamp quantity and circuiting confi gurations. One sensor may control up to 20 ballasts, although adding multiple sensors within a continuous row, or having a single sensor control a long run may create complex wiring scenarios that will involve approved detailed drawings via the Corelite submittal process. For best results, contact Corelite technical assistance on applications involving multiple sensors and/or longer runs. Installation 8 20' Continuous row example: one sensor may control up to 20 ballasts Corelite fl uorescent luminaires with integral DaySense technology install as per standard Corelite products with one exception: for all continuous row applications, the contractor is required to make 2 additional wire connections as per typical low voltage dimming applications. For more detailed standard product installation instructions, visit www.corelite.com 2 Additional Control Through Wires for Continuous Rows Corelite Architectural Lighting Products 4675 Holly St. Denver, CO 80216 Phone: (303) 393-1522 Fax: (303) 393-1477 www.corelite.com 5

How to Specify and Order DaySense Electrical Drawings and Configurations Sensor specifi cation and/or notations within electrical drawings should be done so by a certifi ed professional. Each luminaire having a sensor will be wired in accordance with approved electrical drawings. Confi gurations will be approved via the Corelite submittal process. Select Product Series The suspended linear direct-indirect series' listed below offer DaySense as a standard option. Consult factory for availability of DaySense in product lines not listed below. Specify Circuiting, Dimming and Voltage The DaySense sensor must be used in conjunction with 0-10v dimming ballasts operating on a single circuit. This will be noted as "1D" in the "Number of Circuits" and "Wiring" ordering fi elds. Fixture voltage must also be specifi ed as dimming ballasts are voltage-specifi c (UNV not available). Luminaires having DaySense require a simple switched (on/off) circuit for operation. Additional control hardware is not required. Typical 24 row (sensor not required outside of optimal zone). a Optimal Zone a1 24 row with DaySense (one sensor controls entire row). Specify Sensor When "DS" is specifi ed as the option in the last ordering fi eld, it is assumed that one sensor is controlling the entire row, regardless of the sensor s location within that row. Consult factory for applications requiring more than one sensor per row. For best results Corelite recommends utilizing DaySense in Individual luminaire lighting applications. 15 5 Type A1 Catalog # 24' row with DaySense (sensor controls entire row). Critical DaySense ordering requirements in gray. E2 - WM - 2T5-1D - 277 -AC48 - T1-24' - DS a Product Series b Optics Up c Optics Down d Quantity of Lamps e Lamp Type f Number of Circuits g Wiring E2=Element L2=Loft VB=Vertechs TB=Traverse NB=Navigator MB=Minigator W=White S=Specular B=Cross Blade Louver C=Concave Metallic Perf H=RPerformance Louver M=Micro Prismatic lens W=High Effi ciency Louver 1=1 lamp 2=2 lamp 3=3 lamp N5=T5 Normal Output T5=T5 High Output T8=T8 Normal Output 1=1 Circuit 2=2 Circuits C=Standard Circuit B=Battery Pack D=Dimming T=Nightlight E=Emergency Y=Daylight h Voltage i Suspension j Power Feed k Suspension Length l Ceiling Type m Run Length n Options 120=120v 277=277v UNV=Universal 347=347v A=Aircraft Cable P=Rigid Pendant C=Straight Cord K=Curly Cord P=Rigid Pendant Adjustable Cable 48", 120", 240", 300" or 360" Rigid Pendant 12", 15", 18", 21", 24" or 27" T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar ST=Structure JB=4" Octagonal J-Box Specify overall run length in feet DS=DaySense, Integral Daylight Sensor *Not all options available. Please consult your Corelite representative for availability. Specifi cations and dimensions subject to change without notice. 6 Corelite Architectural Lighting Products 4675 Holly St. Denver, CO 80216 Phone: (303) 393-1522 Fax: (303) 393-1477 www.corelite.com

Technical Info and Summary Specifications Description DaySense is an energy-saving integral luminaire daylight sensor. The sensor "sees" in a downward direction and it reacts to increases in room brightness along a horizontal surface within its fi eld of view. As room surfaces increase in brightness (as a result of daylight) beyond the preset threshold, the sensor then delivers a signal to the luminaire's dimming ballast to reduce light output. The sensor is regulated so as not to exceed a prescribed amount of electrical light, as defi ned by the sensor's geometry and setting. The sensor is limited to the dimming range of the luminaire's dimming ballast. Mounting Guidelines Please follow factory recommendations for best results: 1. Mounting Height: 8'-10' above fi nished fl oor 2. Distance from Window: 5'-15' 3. Room Finishes: As a general rule, for best results specify bright (preferably white) colored room surfaces (this should also include furniture and fl ooring material) having high refl ectance values and a matte fi nish. Dimming Ballast DaySense will only work with dimming ballasts that operate under a 0-10 volt signal. Lamp options are limited to the available options provided by the dimming ballast manufacturer. Consult factory for dimming ballast availability. Corelite recommended ballasts include the Advance Mark VII and the Sylvania Helios. System Design, Layout and Application For best results, Corelite recommends the utilization of "individual" luminaire confi gurations. Individual luminaire applications help ensure a more localized reaction and orientation to the daylight conditions of the task. For example, if a sensor is 50' away from the ballast that it is controlling, it may be dimming lamps in an area that is absent of daylight, and in turn making a task or environment unsafe due to lack of ambient light. The ideal application for DaySense is a small private offi ce or conference room having plenty of available daylight. In these situations, the sensor may be optimally positioned directly over a work surface, which will ensure the sensor is reacting directly to the light conditions of the work surface it is monitoring. This sensor/task alignment may be more diffi cult to achieve in open offi ce spaces with cubicles and miscellaneous obstructions. Specification and Ordering Given the "made-to-order" nature of Corelite luminaires, it is diffi cult to provide all required information in the catalog number with just the "DS" option. The submittal process will provide necessary detail for more complex scenarios. Regardless of row length or sensor location within the row, simply note "DS" at the end of the catalog number to defi ne luminaires having a DaySense sensor. Corelite will assume that the entire row will be controlled by that one sensor unless otherwise noted. For questions regarding specifi cation and ordering, please consult Corelite Technical Assistance and/or Customer Service. Installation and Set-Up DaySense luminaires must be installed by a certifi ed professional electrician as per national and local electrical codes. Luminaires having DaySense sensors install as per typical Corelite luminaires (minus sensor). Visit www.corelite.com for detailed installation instructions for each product series. Corelite suspended luminaires easily mount to existing structure and/or ceiling systems with minimal structural hardware requirements. Luminaires with DaySense require only one additional step beyond standard installation: two additional wire connections in through-wire situations, in continuous rows. Wall Switch Requirements Although luminaires with DaySense require dimming ballasts, they do not require dimming and/or additional lighting controls. Luminaires install as per any standard single circuit on/off (single circuit - "1C") luminaire. A simple on/off wall switch delivers the required line voltage to the ballast, and the sensor in turn dims the ballasts independently of the line voltage circuit. Field Adjustment of Sensor The DaySense sensor is pre-set at the factory to maintain a maximum of 45 footcandles of fl uorescent light under typical conditions. In the event of circumstances requiring either more or less fl uorescent light contribution, the sensor may be adjusted within a range of 1/3 to 3 times the factory pre-set. To adjust the sensor in the fi eld, it is recommended that it be done at night by a certifi ed lighting professional, and that a light meter be utilized to ensure IES recommended light levels are still present for the work surface and/or the environment. Energy Savings Potential DaySense is an innovative energy-saving device, and the level of savings is highly dependent upon the geographic location and season. Results will vary. DaySense Controls Characteristics DaySense compensates for approximately 50% of the added light (simulated and measured with a fl uorescent light source). See graph below. In the case of a natural light source, the compensation is greater than 50%. *Please note DaySense is not designed for maintaining a constant light level. Corelite Architectural Lighting Products 4675 Holly St. Denver, CO 80216 Phone: (303) 393-1522 Fax: (303) 393-1477 www.corelite.com 7

Corelite 4675 Holly Street Denver, CO 80216 P: 303-393-1522 F: 303-393-1477 Cooper Lighting, LLC Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 F: 770-486-4801 www.cooperlighting.com International Sales, USA Cooper Lighting, LLC 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 F: 770-486-4801 Canada Cooper Lighting, LLC 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049 The Cooper Lighting Family Halo Metalux Lumark Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper io Lumière Invue McGraw-Edison Streetworks Fail-Safe PDS MWS RSA Ametrix Domestic Facilities Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia Canadian Facilities Calgary, Alberta T2E 7V9 Mississauga, Ontario L5R 1B8 Cooper Lighting and Corelite logos are valuable trademarks of Cooper Industries in the United States and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com ADE091859 Printed in USA