ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Similar documents
ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Ultrasonic Reflective Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Scale 0: 10 k Scale 50: 10 k (see note 2)

Ultrasonic Reflective Sensor

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

Model Number Structure

onlinecomponents.com

Control Panel Basics Volume 1

Ultrasonic Proximity Sensor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Selection Guide. Logic: From basic to programmable network controllers» Safety Components. Output: Safety relays, servo systems, and inverters

Installation & Operation Manual

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

Original instructions JSNY7 Magnetic switch

Original instructions Sense7-series Non-contact coded safety switch

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Duct Mount. Installation Instructions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

Room Humidity/Temp Sensor

Installation & Operation Manual

Air Pump Up to 800 gallons

Duct Humidity/Temp Sensor

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

SKORPION Process Air Heater

SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC Siargo Ltd. ISO 9001 ISO OHSAS 18001

CO2 Sensor User and Installation Guide

- User Brochure tekmarnet 4 Setpoint Control 161

CD6102 / CD6102 OC / CD6102-2

FloorHeat Installation Manual

Pressurized Filter Up to 1250 gallons

Duct Temperature Sensors

Annuciator Logic Controllers

EQUIPMENT Operation Manual

USER MANUAL SAVE THESE INSTRUCTIONS

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

- User Brochure Programmable Thermostat 510

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

OPERATION MANUAL MODEL 805 ACCELEROMETER

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

installation instructions Fan Tray System FTA-3/FTA-6

EQUIPMENT Operation Manual

SAVE THESE INSTRUCTIONS

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Figure 1. Figure 2. See notes 1 and 2 below.

OPERATION MANUAL MODEL & ACCELEROMETER

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Installation & Operation Manual

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Temperature Controller

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

No Touch Door Release Exit Sensor ACA-NTEB

Instruction Leaflet. Read instructions before operating. Retain for future reference.

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Outside Air Humidity & Temperature Sensor

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Instruction Leaflet. Read instructions before operating. Retain for future reference.

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Humidistat-Thermostat

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Clean Steam Generators

Corrosion Resistant Fluid and Air Handling Systems.

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

FW-RA-LED Remote Multiplex Annunciator Panels

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Design Criteria. Installation

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Environmental Monitoring SmartSlot Card

E5CN-FR Limit Controller USER S MANUAL

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Instruction Leaflet. Read instructions before operating. Retain for future reference.

This instruction manual explains the use of three models listed on the left.

Preamplifier Power Supply PPS-02 user's guide

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Installation and Testing of Inverted Bucket Steam Traps Manual

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

OPERATION MANUAL Model 8011 & mA

E3FA PHOTOELECTRIC SENSORS

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Irene-H READ AND SAVE THESE INSTRUCTIONS

Model Number Structure. Floatless Level Switch (Basic Type)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

TrueClean ToteCleaner

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

Protocol Station Remote Alarm

Transcription:

Humidity Sensor Temperature/Humidity Sensor ES2-THB-N Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control. Employs high-polymer-resistive Sensor with superior durability. Compact and lightweight. Refer to the Safety Precautions page 4. Ordering Information Name Model Humidity Sensor Temperature/Humidity Sensor ES2-THB-N Humidity Sensor Module (See note.) ES2-M-N Note: This is a replacement item. One Module is provided with the /-THB-N. Always attach the Humidity Sensor Module when using the ES2-HB/-THB. Approximately 5.5 VDC will be output for the humidity output if the Module is not attached or is incompletely attached. Specifications Humidity Sensor section High-polymer resistive Humidity detection range 20 to 95% Humidity detection accuracy ±3% (25 C, 40 to 80%) Power supply voltage 24 VDC (See note 1.) Operating voltage range 85% to 110% of power supply voltage Current consumption 4 ma max. Humidity output 1 to 5 VDC (for humidity of 0% to 100%) Permissible load impedance: 100 kω min. (Use a 1:1 connection when connecting to an E5CC/E5EC/E5AC.) Temperature Sensor Section (See note 2.) Platinum resistance thermometer Temperature detection range 0 to 55 C Temperature output Pt100: 3 wire (See note 4.) Class JIS class B Communications cable length 5 m Operating temperature and humidity range (See note 3.) 0 to 55 C, humidity of 95% max. Storage temperature and humidity range (See note 3.) 20 to 60 C, humidity of 95% max. Degree of protection IP 20 Weight : Approx. 37 g (excluding cables) ES2-THB-N: Approx. 39 g (excluding cables) Note: 1. The maximum ripple voltage of 2% p-p max. The recommended power supply is the OMRON S8FS-G or S8VS. 2. ES2-THB-N only. 3. Do not use or store the Sensor for an extended period at a humidity of 90% or more. With no icing or condensation. 4. Pt100 (JIS C 1604-1997) is used for the measuring elements. Set Pt100 for input sensor type of the Temperature. 1

Dimensions ES2-THB-N Note: All units are in millimeters unless otherwise indicated. Humidity Sensor ES2-THB-N Temperature/Humidity Sensor 50 22 Cover Cover 2-4 dia. 37 Terminal block 50 O GI Terminal block BBA 37 Air vent 5.1 dia. * Shield wire in transparent tube Y-shaped crimp terminal for M3.5 Fixing band 5,000 ± 200 (25) White Shield OUT Black Heat-shrinking tube 150 ± 20 The above figure is for the. The ES2-THB-N has temperature output wires (yellow/green/brown). Red G IN Humidity signal * : 5.1 dia. ES2-THB-N: 5.8 dia. ES2-M-N Humidity Sensor Module 8.5 11 30.5 Connectors Note: Firmly insert the connector all the way in when mounting the ES2-M-N to the Sensor. Connection Examples Humidity Sensor ES2-THB-N Temperature/Humidity Sensor ES2-THB-N Yellow Green Brown A B B Temperature input (platinum resistance thermometer) or PT White + Humidity input (1 to 5 VDC) or PT White + Humidity input (1 to 5 VDC) or PT Red Black 24 VDC DC power supply GND Red Black 24 VDC DC power supply GND Shield (Ground separately.) Shield (Ground separately.) 2

Cable Conditions Item Model ES2-THB-N Diameter AWG22 AWG24 Number of conductors 3 6 Shield Braided Braided Maximum conductive resistance (20 C) 60 Ω/km max. 92 Ω/km max. Finished outer cable diameter 5.1 mm 5.8 mm ES2-THB-N Note: Provide a separate cable according to the details listed at the left if the length of the supplied cable is insufficient. The cable can be extended to a maximum of 50 m. For details on the method of handling the shield, refer to Processing Cable Ends in the operation manual packaged with the humidity sensor or temperature/ humidity sensor. Application Examples Temperature and humidity control for vegetable and fruit growing rooms Monitoring and data collection for clean rooms and storage locations ES-THB-N Recorder Alarm lamp Buzzer Factories and clean rooms Air conditioner Humidifier Heater Temperature Humidity control for constant-humidity warehouses and rooms for fermentation or ripening Temperature and humidity control for drying Recorder Humidifier or dehumidifier Office Warehouse ES2-THB-N Dehumidifier Temperature Humidity control for plant factories and greenhouses Exit side Dry air Sirocco fan Heater Exit Entrance Panel Meter Humidifier or dehumidifier Growing bed Recorder Office Plastic greenhouse 3

Safety Precautions ES2-THB-N Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/. Key to Warning Symbols CAUTION Precautions for Safe Use Meaning of Product Safety Symbols Indicates a potentially hazardous situation which, if not avoided, is likely to result in minor or moderate injury or property damage. Supplementary comments on what to do or avoid doing, to use the product safely. Used to warn of the risk of electric shock under specific conditions. Indicates the instructions of unspecified prohibited action. Used to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled. Used for general mandatory action precautions for which there is no specified symbol. Caution Minor injuries may occasionally occur due to electric shock. Do not touch terminals while power is being supplied. Do not open covers when power is being supplied. Electric shock, fire, or device damage may occasionally occur. Make sure dirt such as metals, lead wires, chips during the installation work, etc. or moisture does not enter inside the product. Electric shock, fire, or device damage may occasionally occur. Do not perform disassembly, modification, or repair work. Loosening of screws may cause fire. Make sure the crimp terminal conforms to the screw size of the connection-destination terminal block, and tighten the screws properly to the appropriate torque. Tighten the terminal screws of the internal terminal block properly to the appropriate torque. Precautions for Safe Use Follow the points described below to prevent defective operation or malfunctioning of the product, and also to avoid an ill effect on the characteristics and functions. 1. This product is for internal use only. Do not use or store it in the following environments: Locations that are out of the rated temperature and humidity range Locations where the humidity is constantly 90% or more Locations exposed to water or oil Locations subject to direct sunlight Locations with severe temperature variations Near devices that generate heat Locations subject to hot air or cold air Near hot water or cold water Locations where there could be freezing or condensation Locations with a large impact of vibrations and shock Locations with presence of dust Locations with presence of salt content In inorganic gas environments, such as sulfur dioxide, chlorine, and ammonia In organic gas environments such as alcohols, carbons, glycols, ketones, aldehydes, etc. 2. Follow the points described below when performing work by removing the cover of the main unit, such as during installation of the main unit, installation or replacement of the humidity sensor module, change of cable outlet, or cable extension. Do not touch electronic parts with hands, or apply shock or unnecessary force. Use M3 to M3.5 screws when installing the main unit, and tighten both locations with an appropriate torque. When installing the humidity sensor module, insert it right till the end of the connector. Take care not to scratch or cut off the cables when cutting off the fixing band. When fixing the board on the metallic frame, be sure to pass the side where the shield terminal is present through the shield terminal, and tighten the screws on both locations with the stipulated torque (0.49 to 0.59 N m). For details on the method of handling the shield, refer to About Drawing Out the Cable from the Front Panel in the operation manual packaged with the humidity sensor or temperature/ humidity sensor. Do not touch the notch for fastening the cover as it may cause an injury. Do not touch the flaps of the metallic frame after removing the board from the metallic frame as it may cause injury. 3. Use the product within the rated voltage and current. 4. Be sure to install the main unit in the specified direction. For details on the method of handling the shield, refer to Mounting Method in the operation manual packaged with the humidity sensor or temperature/humidity sensor. 5. When turning on the power supply, set the warm-up time as three seconds or more. 6. Ensure sufficient space around the main unit case so that the air vent is not covered. 7. Wire the terminals correctly after confirming the signal name and polarity. 8. Maintain the load impedance of output at the rated value. 9. If there is any problem in the operation, cut off the power supply and stop the use of the product 10.To prevent induction noise, separate the unit from high-voltage and large-current power lines. Also avoid connecting the unit in a parallel wiring connection or same wiring connection as the power line. 11.Install a surge absorber or noise filter in peripheral devices that generate noise (particularly, devices having inductance components such as motors, transformers, solenoids, magnetic coils, etc.). 12.Install the product as far as possible from strong frequencies and serge-generating devices. 13.Do not connect anything to a crimp terminal that is not in use. 4

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

OMRON Corporation Industrial Automation Company Kyoto, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 OMRON Corporation 2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_1_0318 Cat. No. H230-E1-01 0318 (0318)