Model 5190-F Temperature/Humidity Probe

Similar documents
Model 5190-E Temperature/Humidity Probe

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

MP 601A Humidity Probe INSTRUCTION MANUAL

Model 6021 Electrically Heated Rain and Snow Gauge

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Model 6496 Freezing Rain Sensor

NOVALYNX CORPORATION MODEL A & A SLING PSYCHROMETER INSTRUCTION MANUAL

Potential Applications

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4030/31 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.


HIH-4602-L Series Humidity Sensors

HIH-4010/4020/4021 Series Humidity Sensors

HIH-4000 Series Humidity Sensors

Duct Humidity/Temp Sensor

HIH-5030/5031 Series Low Voltage Humidity Sensors

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

Room Humidity/Temp Sensor

Duct Mount. Installation Instructions

Outside Air Humidity & Temperature Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Environmental Monitoring SmartSlot Card

expandable led Installation & Maintenance Guide Product Description Light 48 IN 21.6W 10K/460nm Expandable Light 36 IN 15W 10K/460nm Expandable

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

OPERATION MANUAL MODEL 8102 ACCELEROMETER

Environmental Monitoring Card

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

OPERATION MANUAL MODEL & ACCELEROMETER

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

GAS MONITOR Model Model

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

HIH-4602 A & C Series.

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

OPERATION MANUAL MODEL 4610 ACCELEROMETER

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

VS2000V Veterinary Vital Signs Monitor Operation Manual

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

RAM 50 Series Operation Manual

User's Guide. Pinless Moisture Meter. Model MO257

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

Reacti-Therm I and III Heating Modules

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

RK CO 2 Transmitter Operator s Manual

User Manual. For use with model CS-10A/CS-11A solar ventilation system controllers

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Model 4001 Series Single Channel Controller

High Temperature Remote Gas Calibrator

Horizontal Bottle Cooler Installation and Operation Manual

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017

Installation & Operation Manual Ice Cream Freezers

RK/ RK Oxygen Detector Operator s Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

RK / RK Methane Detector Operator s Manual

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Hydrazine Analyzer Series 2171 Specifications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Meteorology 432. Hygrometry Spring 2013

RK-05 Combustible Gas Transmitter Operator s Manual

HYGROMER - MP 400 A Meteorology probe

Humidity Monitor model 01080

End-of-Line Encapsulated Resistor. Installation Guide

20 High velocity Air

RK Transmitter Technical Notice

RK Combustible Gas Transmitter Operator s Manual

430128A. B-Series Flow Meter SIL Safety Manual

RK-03 Hydrogen Detector Operator s Manual

Figure 1 DirectLine DL423 Sensor. Description, continued

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

RK/ RK Combustible Gas Detector Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

Intrinsically Safe Transmitters, Option Code 2n

RK/ RK Oxygen Detector Operator s Manual

Reacti-Therm I and III Heating/Stirring Modules

Dehumidification Strategies Application Note

Power Pack Service Manual

YOUR PORTABLE AIR PURIFIER

DIGITAL STEEL FIRE & SECURITY

Installation & Maintenance Guide

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

DIGITAL. Operation & Installation Guide. Read These Instructions Very Carefully! Home and Office Security Safes MFFS2054DF84DF18DFE0809 ENGLISH

Standard SPECIFICATIONS FEATURES APPLICATIONS

OPERATION MANUAL Model 8011 & mA

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Transcription:

Model 5190-F Temperature/Humidity Probe FAA APPROVED ECP234 2017 Mar 13 NOT FAA APPROVED User s Manual Rev. C All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

Copyright 2010 2017, All Weather, Inc. All Rights Reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service All Weather, Inc. manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of All Weather, Inc. Throughout this manual, trademarked names might be used. Rather than put a trademark ( ) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion and to the benefit of the trademark owner, and with no intention of infringement. All Weather, Inc. and the All Weather, Inc. logo are trademarks of All Weather, Inc. Disclaimer The information and specifications described in this manual are subject to change without notice. Latest Manual Version For the latest version of this manual, see the Product Manuals page under Reference on our web site at www.allweatherinc.com/. All Weather, Inc. 1165 National Drive Sacramento, CA 95834 Tel.: (916) 928-1000 Fax: (916) 928-1165 Contact Customer Service Phone support is available from 8:00am - 4:30pm PT, Monday through Friday. Call 916-928-1000 and ask for Service. Online support is available by filling out a request at www.allweatherinc.com/support/online-support/ E-mail your support request to support@allweatherinc.com

Revision History Revision Date Summary of Changes C 2017 Jan 12 Updated Section 3.2 to say return probe to AWI if it fails validation checks only if it is under warranty, removed AWOS warranty chapter.

Table of Contents 1. THEORY OF OPERATION... 1 1.1 Power Supply... 1 1.2 Output Signals... 1 1.3 Environmental Limits... 1 1.3.1 Temperature Limits... 1 1.3.2 Humidity Limits... 1 1.4 Temperature Compensation... 2 1.5 Sensor Protection... 2 2. INSTALLATION & CHECKOUT... 3 2.1 Probe Location... 3 2.2 Wiring Connections... 3 2.3 MARS Installation... 3 3. MAINTENANCE... 4 3.1 Cleaning or Replacing the Dust Filter... 4 3.2 Periodic Validation Check... 4 3.3 Periodic Maintenance (AWOS Installations)... 4 3.3.1 Equipment Required... 4 3.3.2 Monthly Maintenance... 4 3.3.3 Triannual Maintenance... 4 3.3.4 Annual Maintenance... 5 4. SPECIFICATIONS... 6 5. WARRANTY... 7

1. THEORY OF OPERATION The Model 5190-F Temperature/Humidity Probe is designed for a variety of environmental monitoring applications, including All Weather Inc.'s Automated Weather Observing Systems (AWOS). The 5190-F operates with a DC supply voltage and has a low current draw. Relative humidity is measured with a thin-film capacitor sensor, and temperature is measured using a Pt100 RTD with an accuracy of ±0.1 C. The signals from the sensors are converted into two linearized voltage output signals. 1.1 Power Supply The 5190-F requires a voltage source in the range of 5 24 V DC, capable of providing 4 ma. In the case of data logger applications, battery power can be conserved by energizing the probe for only 15 seconds during each measurement. 1.2 Output Signals The 5190-F provides two linearized voltage signals as shown below. Parameter Output Voltage Range RH 0 1.0 V DC 0 100% RH Temperature 0 1.0 V DC -40 C to +60 C Note: Do not connect a load to the outputs with an impedance of less than 10 k. 1.3 Environmental Limits 1.3.1 Temperature Limits The 5190-F was designed to operate from -40 C to +60 C. 1.3.2 Humidity Limits The 5190-F can operate with the RH between 0 and 100%. Direct condensation does not damage the sensors. However, the humidity sensor will not provide correct readings when condensation is present, and neither of the sensors will operate if the sensor leads are short-circuited by condensation. The 5190-F provides a humidity output that is referenced to the saturated water vapor pressure above liquid water. With this reference, the maximum humidity reading at temperatures below freezing are as follows. Maximum RH Temperature Maximum RH Temperature 100% 0 C 81% -20 C 95% -5 C 78% -25 C 91% -10 C 75% -30 C 87% -15 C 1

1.4 Temperature Compensation Practically every make of relative humidity sensor requires a compensation for the effect of temperature on the humidity output signal in order to measure accurately over a wide range of temperature conditions. In the specific case of an instrument using a capacitive sensor, compensation is required because the dielectric characteristics of both the water molecule and the hygroscopic polymer used in the sensor vary with temperature. The electronic circuit of the 5190-F uses data from the Pt100 temperature sensor to automatically compensate the effect of temperature on the accuracy of the humidity measurement. 1.5 Sensor Protection Always use the dust filter provided with the probe to protect the sensors. The standard wire mesh filter is sufficient for most applications. For applications that involve direct spraying of water and/or a lot of dust, use the optional foam filter. 2

2. INSTALLATION & CHECKOUT 2.1 Probe Location Install the probe so that the local conditions at the sensors are typical of the environment to be measured. In an outdoor environment: Use either a shield or a shelter to protect the probe and sensors from direct exposure to solar radiation and precipitation. Several shields are available from All Weather Inc., including the Model 8190 Motor Aspirated Radiation Shield (MARS). In an open field, install the probe at least 5 feet (1.5 m) above ground. Increase this distance if the ground surface is concrete or blacktop (such as above a roof). 2.2 Wiring Connections The 5190-F is supplied with a 5-meter cable (about 16 ft) terminated with tinned ends. Some slack should be left in the cable to allow for a drip loop and to facilitate access to the probe for cleaning and replacement, otherwise any excess length may be trimmed. When a longer cable is required, consider using an extension cable for distances up to 30 m (100 ft). Connect the wires as shown below. Wire Color TB2 Terminal Ground / Gray, Yellow, and Shield 4 Supply Voltage (+) Green 3 RH White 2 Temperature Brown 1 Note: Any other wires colors from the sensor should be covered and insulated so they do not make electrical contact. Check for wiring errors before powering the probe. Improper wiring may damage the probe. Note: Whenever possible, AWI recommends grounding the (-) side of the probe supply voltage. 2.3 MARS Installation If the Model 8190 Motor Aspirated Radiation Shield (MARS) is used with the 5190-F probe, refer to the 8190 MARS User's Manual (8190-001) for installation instructions. Note: In AWOS installations where a 5190-F is installed in a MARS, if the MARS fan fails, temperature and dew point will both be reported as missing. 3

3. MAINTENANCE 3.1 Cleaning or Replacing the Dust Filter The dust filter should be cleaned annually, depending on the conditions of measurement. Whenever possible, cleaning should be done without removing the filter from the probe. Clean the filter with a small brush to remove any debris that may have accumulated on the filter. To replace the filter, unscrew the filter from the probe, replace the filter in the housing, and reinstall the filter assembly. Note: If you remove or replace the filter, make sure that the sensors do not get caught. The humidity sensor is sometimes mistaken for a white paper tag. Do not remove the probe! Before putting on a new dust filter, check the alignment of both sensors with the probe. The wires that connect the sensors to the probe are very thin and bend easily. If this happens, correct the alignment by holding the sensor very gently with a pair of small flat nosed pliers. Do not puncture the sensor with sharp pliers or tweezers or pull too hard on the sensor. 3.2 Periodic Validation Check Long-term stability of the humidity sensor is typically better than 1% RH per year. For maximum accuracy, the accuracy checks that are part of the triannual maintenance described below must be performed. Applications where the probe is exposed to significant pollution may require more frequent verification. Both the Pt100 RTD temperature sensor and associated electronics are very stable and should not require any calibration after the initial factory adjustment. 3.3 Periodic Maintenance (AWOS Installations) 3.3.1 Equipment Required The following equipment is required for periodic maintenance of the Model 5190-F. Psychrometer Psychrometric calculator (All Weather Inc. Model 5282-A) All Weather Inc. sells many types of psychrometers, including the Model 5230 Assmann Psychrometer and the Model 5211 Sling Psychrometer. Contact All Weather Inc. for ordering information. 3.3.2 Monthly Maintenance Monthly maintenance of the Model 5190-F consists of checking the 8190 MARS and cleaning it if dust or debris is observed. 3.3.3 Triannual Maintenance Triannual maintenance of the Model 5190-F consists of performing the monthly maintenance tasks, cleaning the dust filter if dust or debris is observed, and checking the accuracy of the 5190-F against readings made using a psychrometer as explained below. 1. Position the psychrometer in close proximity to the intake of the motor aspirated radiation shield. Allow a minimum of 20 minutes for psychrometer conditioning before proceeding. 4

2. Prepare the psychrometer after the waiting period by wetting the wet bulb wick with distilled water. 3. Wind the psychrometer fan motor to provide constant aspiration (Assmann psychrometer only). 4. Begin taking measurements 1.5 minutes after the psychrometer starts running. Start recording the measurements once the temperature readings have stabilized the maximum difference between successive measurements is less than 1 F (0.56 C). Record the psychrometer temperature, wet bulb temperature, 5190-F temperature, and 5190-F dew point temperature at 1-minute intervals. 5. Average all individual psychrometer temperature readings and 5190-F temperature readings that are within ±1 F (±0.56 C). Subtract the average psychrometer temperature from the 5190-F temperature. For AWOS installations, check the pass status on the data sheet if the result is within ±2 F (±1.1 C). If the probe fails validation, replace it. Return the failed probe to All Weather Inc. only if it is still under warranty. 6. Average all individual wet bulb temperature readings that are within ±0.5 F (±0.28 C) of each other. Calculate the dew point temperature from the average psychrometer temperature and the average wet bulb temperature using the psychrometric calculator. Subtract the calculated dew point temperature from the AWOS dew point temperature. Check the pass status if the result is within ±3 F (±1.7 C). If the probe fails validation, replace it. Return the failed probe to All Weather Inc. only if it is still under warranty. 3.3.4 Annual Maintenance Annual maintenance consists of performing the monthly maintenance tasks and checking the accuracy of the 5190-F against readings made using a psychrometer according to the procedure prescribed for triannual maintenance above. 5

4. SPECIFICATIONS Parameter Humidity Sensor Temperature Sensor Operating Temperature Limits Humidity Output Signal (linear) Temperature Output Signal (linear) Minimum Load per Output Accuracy (at 23ºC) First Signal After Measurement Interval Supply Voltage Current Consumption Cable Length Sensor Protection Dimensions Weight Thin-Film Capacitor Pt100 RTD -40 C to +60ºC 0 1.0 V DC = 0 100% RH Specification 0 1.0 V DC = -40 C to +60 C 10 kω ±1.5% RH ±0.1ºC 2.3 s 0.7 s 5 24 V DC approx. 4 ma 5 m (16 ft), tinned ends Wire mesh filter 208 mm 15 mm diameter (8.19" 0.59") 120 g (0.27 lb) 6

5. WARRANTY Unless specified otherwise, All Weather Inc. (the Company) warrants its products to be free from defects in material and workmanship under normal use and service for one year from date of installation or a maximum of two years from date of shipment, subject to the following conditions: (a) The obligation of the Company under this warranty is limited to repairing or replacing items or parts which have been returned to the Company and which upon examination are disclosed, to the Company s satisfaction, to have been defective in material or workmanship at time of manufacture. (b) The claimant shall pay the cost of shipping any part or instrument to the Company. If the Company determines the part to be defective in material or workmanship, the Company shall prepay the cost of shipping the repaired instrument to the claimant. Under no circumstances will the Company reimburse claimant for cost incurred in removing and/or reinstalling replacement parts. (c) This warranty shall not apply to any Company products which have been subjected to misuse, negligence or accident. (d) This warranty and the Company s obligation thereunder is in lieu of all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, consequential damages and all other obligations or liabilities. No other person or organization is authorized to give any other warranty or to assume any additional obligation on the Company s behalf, unless made in writing and signed by an authorized officer of the Company. 7

All Weather Inc. 1165 National Drive Sacramento, CA 95818 5190-F-001 Fax: 916.928.1165 Revision C Phone: 916.928.1000 January, 2017 Toll Free: 800.824.5873