MÖBIUS Recycler. Condensing Liquid Nitrogen HPGe Detector Cooling System

Similar documents
MÖBIUS Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System

ICS Integrated Cryocooling System

ICS Integrated Cryocooling System

ICS Integrated Cryocooling System

ORTEC ICS-P4 TM. Integrated Cryocooling System for ORTEC PopTop TM Capsules. User Manual

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

X-Cooler III Mechanical Cooler for HPGe Detectors

North American Technical Services

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

NEW COOLING OPTION FOR DETECTORS

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Technical Specification PILATUS 100K Detector System

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

Black Body Calibration Source User Manual

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

A n hybrid liquid nitrogen system for the cooling. of the ESO O mega C A M detector

Remote Helium Cooling Loops for Laboratory Applications

Environmental Chambers

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

DHR Accessories Requirements. Site Preparation Guide


Liebert PPC Second Generation Power Distribution Cabinet

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

UDC100 Universal Digital Controller Specifications

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

I/A Series 716C 1/16 DIN Temperature Controller

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

G4 Pulsed Fiber Laser

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Hotplates, Magnetic Stirrers and Stirring Hotplates

A New Standard of Excellence

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

LAUNDRY MONITORING SYSTEM Model # LIM-64S

Thermal Shock Chamber TSE 11

Rotavapor R-220 Pro Technical data sheet

Plant Growth Chamber MPGR14

Applications and Accessories, Cryo Pumps

EVD-1 Installation, Operation, and Instruction Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

21-light Remote Annunciator. Owner s Manual

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Freeze Dry Systems and Accessories

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

Rotary Evaporators designed

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Oxygen (O2) Single-Point Gas Detection System

Across-the-Line SERIES MP300 Combined Manual and Automatic

Variable Frequency Drive SERIES MP800 VFD

Dual Input ph/orp Analyzer

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Freeze Dry Systems and Accessories

Development of a mobile facility for monitoring of radioactivity in food during an emergency

Technical Specification and Operating Procedure PILATUS 300K

Ceiling PIR HS presence detector. Product Guide. Overview. Features

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

AUTOMATED CLIMBER DETECTION

TA Instruments Installation Requirements for Rheology Systems

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

RC4000 Radiation Detection System

REVO JOB INSTALLATION AREA. REVO Job SELECTION TABLE MAIN FEATURES OF THE PRODUCT PROFESSIONAL. CE marking. Automatic filter cleaning

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

OIL COOLER INSTRUCTION HANDBOOK

Rosemount 4500 Hygienic Pressure Transmitter. Start

BSR Addressable Fire Detection control panel. Installation operation manual

Reach-In. PLanT GROWTh. Reach-In

LC1350 Level Controller

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Rotavapor R-220 Pro Technical data sheet

Cryogenic Autofill for AGATA. I. Kojouharov GSI, Darmstadt

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

Alpha Spectroscopy. Vacuum Light. Important things to know before you load your samples:

Document # R01

Soft Start Series MP700 Solid State, Reduced Voltage

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

TCC-34. Features: TISSUE CULTURE

What is an Integrated Detector Assembly? Aron Traylor. College of Optical Sciences The University of Arizona 29 November 2010.

UV Flame Supervision System

Highlights of Germanium Detector technology

BC3250. Blowdown Controller

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

TEMPERATURE CONTROLLER

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Recirculating Coolers

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Built-in HF Sensor for High Bay

Liquid Nitrogen Storage Solution

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Product Tests Report

Product Specification Qualification Test Report

Transcription:

Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System All the advantages of Liquid Nitrogen cooling without the need for frequent refilling.

Introduction The ORTEC Möbius Recycler technology provides tried and tested LN 2 cooling of your HPGe detector in a system where LN 2 requires refilling approximately once every other year under normal, continuous operating conditions. This is achieved by the integration of a Sunpower cryocooler and a specially designed 28 liter liquid nitrogen dewar. The Möbius Recycler provides an excellent strategy for managing counting laboratories which have periodic power failures. A smart cooler controller senses when the Möbius is operating on an uninterrupted power supply (UPS) and automatically disables the cryocooler to minimize the power drain. This feature allows extended system operation when using smaller capacity UPS systems. The LN 2 level monitor provides status regardless of mains power loss. While your laboratory may be in the dark, you won t be, when it comes to knowing the fill level of the LN 2 dewar. ORTEC warrants the resolution performance for a new detector purchased with the Möbius Recycler to the detector's published performance specifications. Key Benefits Ability to achieve LN 2 performance without the requirement for frequent system refilling thus saving time, money and reducing hazardous material handling. During a loss of input power, the Möbius will continue cooling the detector as if it were a standard dewar. A large 28 liter dewar improves the duration for cooling during a power loss and helps extend the time between system refills. LN 2 level monitor can be remotely mounted and indicates LN 2 fill level, power consumption, and pressure levels allowing for proactive maintenance scheduling. Smart controller reduces UPS strain while allowing continued operation during a power outage. Integrates easily underneath standard lead shields with same footprint as standard dewar. Diagnostics and health parameters accessible by Windows PC. Flexibility with a wide range of cryostat and detector orientation including vertical options as well as side mounted configurations. Swap detectors as needed with any dipstick style Möbius or PopTop compatible Möbius-B. Excellent service and support built upon ORTEC s unique, fully vertical factory integration for design and quality of manufacturing. Möbius Recycler is the first product from the combined talents of ORTEC and the technology-leading cryocooler company Sunpower, acquired by AMETEK late in 2012. 2

Möbius with Vertical or Horizontal Dipstick Cryostat Möbius with Side-Looking Cryostat 3

Möbius with J-style Cryostat Möbius with HJ-style Cryostat with Remote Preamp 4

Performance Specifications Refill Period Maintenance Remote Display Internal Controller Level Sensing Use with UPS Systems LN 2 Holding Time (in case of power loss) LN 2 Loss Rate Spectroscopic Performance After the detector is cool and the LN 2 is topped off, the Möbius system can run for 2 years or longer without filling. This is based on the sealing technology and assumes that it is operating in uninterrupted, steady state conditions. Easily removable, washable, air inlet filter. No other maintenance is required. The remote display attaches to the system with an umbilical cord and can be remotely mounted to improve visibility when the detector is placed in a lead shield. The display indicates LN 2 fill height level, power consumption, pressure and overall status information. The user is warned when the dewar level drops below 70% full. The control electronics and power supply are electrically isolated from the dewar, as is the cooler, and protected from LN 2 spillage. A capacitance level sensor provides a continuous measurement of the LN 2 level from 0 100% full. The Möbius Recycler contains a small onboard computer which can receive an input in the event of power loss. The input causes the system to enter power saving mode and turn off the cryocooler. With the cryocooler turned off, the onboard computer and diagnostic electronics may be powered by a small UPS. Approximately 7 10 days for a typical detector in a Streamline cryostat if Möbius is full. Approximately 4 7days for a typical detector in a PopTop cryostat if Möbius is full. Approximately 3 liters per day when cooler is off. Operates as a standard dewar when power loss occurs. When purchasing a new ORTEC detector with a Möbius, resolution is based on the detector data sheet. For existing ORTEC detector systems: when replacing an existing dewar or X-COOLER with a Möbius, resolution degradation is based on the existing detector performance. Above 15 kev, no degradation of the detector warranted resolution. Below 15 kev, less than 10% of the warranted resolution. It is expected that the detector will have similar performance compared to using a standard liquid nitrogen dewar. Some degradation may occur, depending on age and configuration of the detector. Mechanical Specifications Dewar Capacity Cooler Auxiliary Cooling Audible Noise Electrical Supply Normal Power Consumption Dimensions Weight (excluding cryostat and detector) Operating Temperature Warranty CE NRTL 28 Liters, excluding detector dipstick volume. AMETEK SUNPOWER with passive vibration dampening. Internal fan. Less than 60 db (A) at 1 meter fully operational, below 30 C ambient. 100 240 V AC auto ranging from 120 to 240 V, 50 to 60 Hz. 125 W typical, 350 W maximum. See drawings on previous pages. 63 lb (28.58 kg) empty. 113 lb (51.26 kg) full. 0 to 40 C. 20% to 90% relative humidity, non-condensing. 2 years on Möbius unit only (excludes HPGe detector). Conforms to CE standards for radiated and conducted emissions, susceptibility and low-voltage power directives. Certification verifies, through OSHA-approved NRTL certification authority SGS, that the product meets U.S. electrical safety standards (UL/ANSI 5

Ordering Information Möbius with Dipstick Cryostat MOBIUS-PT MOBIUS-ST MOBIUS-PT-DET MOBIUS-ST-DET Möbius with Side-looking or J-style Cryostat MOBIUS-B CFG-PS4-MOBIUS-B CFG-PS4-MOBIUS-B-DET Möbius Recycler for PopTop detector. Includes 1.5 (38.1 mm) diameter collar and CLAMP-1.50 to fit horizontal (CFG-PH4) or vertical (CFG-PV4) dipstick cryostat. Möbius Recycler for Streamline detector. Includes 1.5 (38.1 mm) diameter collar, CFG-ADAPTOR and CLAMP-1.25 to fit horizontal (CFG-SH or CFG-N-SH) or vertical (CFG-SV) dipstick cryostat. MOBIUS-PT purchased in combination with any PopTop detector and CFG-PV4 vertical dipstick cryostat or CFG-PH4 horizontal dipstick cryostat. MOBIUS-ST purchased in combination with any Streamline detector and CFG-SV vertical dipstick cryostat, CFG-SH horizontal dipstick cryostat, or CFG-N-SH horizontal dipstick cryostat. Möbius Side-looking Recycler for purchase with a detector and J-style cryostat (CFG-HJ or CFG SJ), or side-looking cryostat (CFG-SL). (Note, Möbius-B may only be purchased with a detector.) Möbius Side-looking Recycler for purchase as a stand alone for any PopTop detector. CFG-PS4-MOBIUS-B-DET purchased in combination with any PopTop detector. Options for Möbius with Dipstick Cryostat only CFG-ADAPTOR CLAMP-1.25 CLAMP-1.50 MOBIUS Collar adaptor allows use of 1.25 diameter dipstick cryostat. Detector clamp for 1.25 dipstick diameter. Detector clamp for 1.50 dipstick diameter. Möbius Recycler. Includes 1.5 (38.1 mm) diameter collar. CFG-ADAPTOR Notes 1) Other Möbius configurations are available as a special order. Contact the factory for more information. 2) Retrofit of an existing customer detector into MOBIUS-B requires the detector to be returned to the factory. CLAMP-xxx 6

7

Specifications subject to change 051117