How to ensure Thermal Comfort in buildings with CFD

Similar documents
MECHANICAL SERVICES 101. Ian White

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Comfort and health-indoor air quality

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

CHAPTER 4. HVAC DELIVERY SYSTEMS

Flexible and efficient: Close Climate Control for IT equipment

Chapter 10. Passive Cooling Contents

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

As mentioned earlier, the fundamental purpose of HVAC systems is to provide human comfort.

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

2. CURRICULUM. Sl. No.

HVAC (Heating, Ventilating, and Air Conditioning)

Armstrong Cool-Fog Systems

Ventilation in Humid Climates: Data from Field Experiments

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Passive Indirect Evaporative Cooler

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Oxyvap Evaporative Cooling Applications

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Appendix 13. Categories of Cooling and Heating systems

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

Numerical study of heat pipe application in heat recovery systems

Bill McCullough. Director ERV Products. Dallas, TX

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

HVAC Water chiller selection and optimisation of operation

K.F. Fong *, C.K. Lee, T.T. Chow

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Halton Vario Design Guide

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples

Recent Advances in Energy, Environment and Economic Development

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

ALFAMINI-ALFAMAX Central Station air handling units high efficiency for wellness areas

Experimental study of space cooling using ceiling panels equipped with capillary mats

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Passive Solar Home Design

Reviewing HVAC Designs for Compliance with ACCA Manual S

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Appendix A. Glossary of Common Terms

Safety Regulations and Procedures ENVIRONMENTAL HEALTH Indoor Air Quality - Work Practices - S New 1/95

Dehumidifying with Dedicated Outdoor Air

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Presentation on HVAC: Heating Ventilation Air Conditioning

Consumer Features & Benefits of Energy Efficient Products

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

80-6-ISD A Better Solution for Proper Space Air Distribution

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Summary: thermal analysis, CFD simulations. - Enrico Da Riva - CERN (EN/CV/PJ) Workshop on SiPM cooling for Fiber Tracker, 17 October 2013

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Energy Recovery Ventilation

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ENERGY EFFICIENT RETROFITS. Date

Desiccant Cooling with Solar Energy

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Energy Consumption Reduction of AHU using Heat Pipe as Dehumidifier

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Chapter 14, Problem 27.

WHY IS BUILDING SCIENCE IMPORTANT?

Munters DesiCool removes excess heat in server room

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

Transcription:

How to ensure Thermal Comfort in buildings with CFD Using CFD Simulations to analyze and improve HVAC Systems Simulation in your browser

How to Ensure Thermal Comfort in Buildings with CFD How to use CFD Simulations to Analyze and Improve HVAC Systems. Thermal comfort is vital at home, in vehicles, within commercial buildings as well as in offices. Designing air conditioning systems for heating and cooling that provide optimal comfort at varying ambient conditions has always been a complex challenge for HVAC (Heating, Ventilating, and Air Conditioning) engineers. It is complex because air conditioning systems are designed for specifically defined loads, with a specific amount of refrigerant and a specific airflow through the cooling coils; however, these systems often fail to meet the comfort expectations of the users. The quality of HVAC systems is affected by changes in the following five basic parameters: 1. Ambient temperature 2. Relative humidity (RH) 3. Air movement 4. Air quality 5. Mean radiant temperature Ambient temperature and relative humidity (rh) The first two parameters ambient temperature and relative humidity are the psychrometric processes of air for a particular climate, location, and altitude with seasonal and daily variations beyond human control. These two parameters combined indicate the heat content of air at any point in time enthalpy. The first and foremost objective of the aircon is to reduce the enthalpy of the conditioned space. When the enthalpy of conditioned space is reduced, its air temperature and water content decrease. This results in the cooler air, coupled with evaporative cooling effect for human occupants. Human beings generally feel comfortable at an ambient temperature range of 294 degrees Kelvin (21o C) to 299 degrees Kelvin (26o C) when the RH value of the air is around 70% or less. For health and cleanliness reasons, the optimum zone for RH is 40% - 60%, as indicated in Figure-1 below. How to Ensure Thermal Comfort in Buildings with CFD SimScale 2016 2

For Cooling Load Calculations, the air temperature value above the comfort range indicates the Sensible Cooling Load while the RH value of air above the optimum zone indicates the Latent Cooling Load of the conditioned space. At particular outside ambient conditions, both these loads may change with an increase in movement of fresh air into the conditioned space and increase in the occupancy (people as well as running equipment) of the conditioned space. The calculation of both these cooling loads is the basic step of an iterative HVAC design process. It is important to highlight that over-sizing the equipment is not a solution for increasing thermal comfort. Over-sizing not only results in increased installation & operational costs but often causes short-cycling of the air conditioning system which results in under performance (the system may not run long enough to attain condensation temperatures at all cooling coils) and increased system wear due to increased start-stop cycles. True thermal comfort created through air conditioning systems is achieved by giving additional consideration to the other three parameters responsible for the desired air conditioning quality: air movement, air quality, and mean radiant temperature. All three are discussed in the following sections. Air Movement Moving air gives a pleasant feeling. When air moves past our skin it enhances the evaporative cooling effect thus making us feel comfortable even at higher than comfort zone temperatures. Thus air movement creates a breeze like an effect in the conditioned space which adds to the human comfort. On the other hand, air movement can be uncomfortable at lower temperatures similar to the Wind Chill Factor. Wind chill is the human feeling of a lower temperature than actual when cool air at 283 degrees Kelvin (10o C) flows past the exposed skin. A section of conditioned space which is exposed to direct air stream from cooling coil causes discomfort. Studies performed to analyze and simulate study temperature distribution of a conditioned space using CFD (Computational Fluid Dynamics) tools, which are also equipped to perform thermodynamic calculations for CAE (Computer-aided Engineering), can help us identify high-temperature spaces where a forced air movement can improve human comfort. Such simulations can be rerun with changing parameters to investigate the best possible airflow with respect to identifying and eliminating uncomfortable zones in an otherwise comfortable air conditioned space. Figure 2 A CFD simulation snapshot of air temperatures inside an office space with cooling vanes installed close to ceiling for air conditioning Red color sides indicate heat transfer through windows Walls and ceilings were treated as adiabatic Fresh air movement through two doors. How to Ensure Thermal Comfort in Buildings with CFD SimScale 2016 3

Figure 2 is a snapshot of a steady state simulation carried out on the SimScale cloud-based simulation platform, showing 3-dimensional temperature distribution of the conditioned space. Blue represents the coolest zone and red/ orange the hottest zone. The space near the windows has been identified as tending to be uncomfortable zone. This is important information; normally, people prefer to sit close to a window with blinds removed to enjoy the outside view and to have a feeling of openness. The simulation snapshot has identified the weakness of the HVAC system to create a comfort zone close to windows and this uncomfortable feeling will increase at high ambient conditions. Figure 3 A CFD simulation snapshot of air temperatures inside an office space with cooling vanes for air conditioning Top view clearly identifies temperatures above the comfort zone Walls and ceilings were treated as adiabatic Fresh air movement through two doors. Figure 3 is a plan-view snapshot of the same steady state simulation carried out on SimScale, showing temperature distribution along the length and breadth of the conditioned space, blue being the coolest zone and red/orange as the hottest zone. This top view has again highlighted the weakness of the HVAC system design to create comfortable air conditioning close to windows. AIR QUALITY Governmental agencies keep educating the public about deteriorating Air Quality Index (AQI) of various metropolitan areas how polluted air is due to vehicular and industrial emissions. An increase in AQI means that the health of more people gets adversely affected. However, it is seldom emphasized that air quality of a conditioned space, especially homes, can be worse than the outside air quality if proper ventilation is not maintained. Various studies related to human exposure to pollutants done by Environmental Protection Agencies have indicated that indoor air quality can be many times worse than the outside air quality which causes building related discomfort and health issues for the occupants. Use of activated carbon filters coupled with appropriate provisioning of fresh air improves the indoor air quality. An additional inside pollutant is noise, created in the conditioned space due to noisy fans and blowers. The noise factor is usually considered while designing air handling units for an HVAC system and outside air movements around a building can be studied to supplement AHUs and improve noise levels. How to Ensure Thermal Comfort in Buildings with CFD SimScale 2016 4

Mean Radiant Temperature Various equipment (refrigerator, cold water dispenser, photocopier, printer, laptop, etc.) and structural components (heated rooftop, heated wall, window sill, window glass / grill) in addition to spreading heat through convection in the conditioned space, are also a source of hot body radiation. Likewise, cold walls and windows suck heat from the human body through radiation. This phenomenon is called mean radiant temperature effect. In simple words, a heated wall is radiating more energy towards the human body than the energy radiated by human body towards the wall, causing a heat source (which is uncomfortable during summer). A cold wall, in turn, is radiating less energy towards the human body than the energy radiated by human body towards the wall causing a heat sink (which is uncomfortable during winter). How does this it affects thermal comfort in a building? Even if the temperature of the conditioned space is below 299 degrees Kelvin (26 C), people may feel uncomfortable as such heated surfaces keep blasting heat towards them. This phenomenon, which is applicable to both heating and cooling, is also manifested in Figure 2 above, where the heated window panes are a constant source of heat radiations, in addition to convective heat input to the conditioned space. Simulating Air Movement Air movement, air quality, and mean radiant temperature are interrelated issues in a conditioned space. Appropriately designed air movement coupled with necessary ventilation and insulation can adequately handle all the three issues. Knowledge of outside air movement, especially in high-rise buildings, also helps in utilizing outside air pressure and velocity in designing efficient air ventilation systems and ensuring inside air movement. Figure 4 below is the result of a CFD simulation done on SimScale a Computer-Aided Engineering (CAE) solution. The pressure velocity profile of air around a high-rise building, obtained through simulation, can help in efficiently designing Outdoor Air Intake, Exhaust Air outlet, and Return Air route through the HVAC system s ducts. This information also helps in optimizing noise levels inside the conditioned space. Figure 4 A CFD simulation snapshot of wind velocities and pressure variations around a high rise building The information obtained through such a simulation can be used in improving air ventilation through HVAC systems Provides useful information about static pressure head for air circulation systems How to Ensure Thermal Comfort in Buildings with CFD SimScale 2016 5

HVAC systems are designed for human comfort. Engineering simulation and Computational Fluid Dynamics (CFD) in particular helps in anticipating, quantifying, and avoiding any uncomforted areas at the design stage. As a result, various components of HVAC systems perform in harmony, creating an efficient, durable and healthy conditioned space where people feel at home. Conclusion When it comes to designing modern air conditioning systems, thermal comfort along with energy efficiency and performance are crucial factors that need to be considered my HVAC designers and manufacturers in order to stay competitive. Adopting new technologies can be the differentiator whether we talk about the IoT trend with smart HVAC products or engineering simulation technology and CFD tools in particular. Engineers working in the HVAC industry can benefit from the emerging cloud-based CAE solutions like SimScale, incorporating simulation technology in their design process with minimum up-front investments and plenty of available resources for a fast adoption. Author Syed Kamran Ali is a professional engineer with more than 20 years of experience in the HVAC and Oil & Gas fields. He is working with CFD simulation of fluids in pipelines, be it a refrigerant piping, an oil / gas transmission line or any hydraulic measurement and control system with known fluid properties. Kamran is specialized in HVAC systems design based on Organic Rankine Cycle Turbines (heat recovery or solar applications) and Vapor Compression Cycle Heat Pumps. Possesses authoritative skills regarding fluid measurement systems for custody transfer applications For further information about SimScale and upcoming webinars and workshops, subscribe to our social media channels or go to www.simscale.com Pelkovenstrasse 145 80992 Munich, Germany Phone: 49 89 809 1327 70 Email: contact@simscale.com How to Ensure Thermal Comfort in Buildings with CFD SimScale 2016 6