Understanding Your Options: AFCI Protection and the 2015 CE Code

Similar documents
2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

2011 and 2014 National Electrical Code Changes Residential Only

GE Industrial Solutions. Residential Electronic Circuit Interrupters

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

TECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009

WHITE PAPER: THE IMPORTANCE OF ARC FAULT CIRCUIT INTERRUPTER TECHNOLOGY

GROUND FAULT PROTECTION METHODS & 2017 National Electric Code

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers

Combination Type AFCI

2009 ELECTRICAL CODE REQUIREMENTS

Electrical Tech Note 107

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Residential Wiring (2014 NEC) (Homestudy)

FIRE ALARM: BY OTHERS, IF REQUIRED.

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

FIRE ALARM: BY OTHERS, IF REQUIRED.

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Arc-Fault Circuit Interrupters (AFCIs) Frequently Asked Questions

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

A HOMEOWNERS HANDBOOK

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

AF/GF dual-purpose receptacles

Units 2, 3, 4, 5, 6, 8, 9, 10, Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition)

Revisions for the 2011 National Electrical Code - Part 1

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Residential Wiring According to the 2011 NEC

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Chapter 1 General... 5

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

Instructor: L. Keith Lofland

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

Residential Wiring (2017 NEC) (Homestudy)

MODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

The Association of Electrical and Medical Imaging Equipment Manufacturers Arc Fault Circuit Interrupter

Residential Wiring According to 2011 NEC (Homestudy)

NECA 169. Standard for Installing and Maintaining Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

Spring Test 6 due 04/26/2013

Pocket Guide to Whole House Safety. Whole house safety

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

Troy's Home Inspection Services LLC

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

NEC Code Changes. Overview of 2011 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

whole house safety Pocket Guide to Whole House Safety Siemens Energy & Automation, Inc Old Milton Parkway Alpharetta, GA 30005

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

MONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.

INSTALLATION AND OPERATION INSTRUCTIONS FOR

Page 1 of General

NEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Advances in Load Center Technologies and End-of-Life GFCI Breaker Limitations

Revisions for the 2014 National Electrical Code

Pocket Guide usa.siemens.com/afci

SW District 1. 1 Tony Tadysak Craig Mulder

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

2017 NEC Presented by: Russ LeBlanc

Arc Fault Circuit Interrupters The Next Generation of Fire Prevention - The Next Generation of Recovery Opportunities

TOM BURNS, PLANNING DIRECTOR

Alberta Municipal Affairs

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

It should be done through a connection authorization - Should be consistent for all LDCs, to avoid interpretation, public safety risk and liability

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

HOW TO REPLACE ELECTRICAL OUTLET WITH GFCI E-BOOK

HOW TO REMOVE WIRES FROM LIGHT SWITCH E-BOOK

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Inspection Report. Inspection Date: 1/1/2011. MultiFamily Sample. Property Address: Street Address. City NJ Zip. All In One Home Inspection LLC

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

PANELBOARDS & BUILDING DISTRIBUTION

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

SDEC 2017 Questions, Group 1

Quality. Trust. Value. Safety.

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

2009 WESTERN SECTION CODE PANEL QUESTIONS

Intellectual Properties, Trademarks and Copyrights

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

University of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES G4.2 ELECTRICAL WIRING

Dwelling unit feeder/service conductor calculations

Home Fire Safety Checklist

Residential * Commercial * Mobile Homes * New Construction

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012

MaxLite LED Round Pendant Highbay Series

SMALL HOMES COUNCIL - BUILDING RESEARCH COU CIL CIRCULAR SERIES INDEX G4 2 NUMBER ELECTRICAL WIRING

Inspection Report 123 My Street Midland, GA

Transcription:

Understanding Your Options: AFCI Protection and the 2015 CE Code November 25, 2014 Eaton 2008 Eaton Corporation. All rights reserved.

Classifying An Arc Fault Operational Arcs - occur in a properly functioning electrical system Switching loads ON/OFF Contact closure/opening Non-Operational Arcs - potential fire hazards Damaged insulation in fixed wiring and appliance cords Loose connections 2 2

Operational Arcs Examples of operational arcs: 3 3

Hazardous Arcs Examples of non-operational arcs 4 4

Wiring Degradation Drivers Temperature Humidity Mechanical Stress Voltage Stress Time Loose Connections Stranded Aluminum Wiring Corrosion Do-it-yourselfers Rodents 5 5

Life Phases of the Home There are three major phases during the lifespan of a home CONSTRUCTION Average of 50-75 junction boxes, switches and outlets Thousands of feet of wire Electricians work comes before drywall, cabinets, shelving and trim HOMEOWNER MOVES IN Homeowners modify by adding dimmers, ceiling fans, more lights Pictures get hung and more shelves are installed Appliances put in place, extension cords used, spa s installed AGING STRUCTURE Additions will occur Rodents may move in Wire degradation due to humidity, heat, vibration Weakening connections due to repetitive use More loads may be added 6 6

Arc-Fault Circuit Interrupter Technology 2008 Eaton Corporation. All rights reserved.

Types Of Arcing Faults L1 N Gnd Parallel Arcing (Line-Neutral) Parallel Arcing (Line-Gnd) Equipment Grounding Conductor Series Arcing Load High Current Level Arc Parallel Arc An Arc Fault that occurs at 75Amps and higher An Arc Fault that occurs Line-Line or Line-Neutral Low Current Level Arc Series Arc An arc fault at low levels down to 5 Amps An arc fault at a break or gap in a single conductor in series with a connected load 8 8

AFCI Circuit Breaker vs. Receptacle An AFCI circuit breaker protects the entire circuit from its origin in the load center for both parallel and series arcs AFCI Circuit Breaker installed in the panel Standard Receptacle High Current Parallel Arc Protection Low Current Series Arc Protection An AFCI receptacle can protect all downstream wire and connected cords from both parallel and series arcs, but only protects from series arcs upstream in the home run Standard Circuit Breaker installed in the panel AFCI Receptacle Circuit protected downstream from both series and parallel arcs High Current Parallel Arc Protection Low Current Series Arc Protection Homerun only protected from series arcs 9 9

Codes And Standards 2008 Eaton Corporation. All rights reserved.

2015 CE Code 2015 CE Code, Rules 26-724 (f) and (g) (f) each branch circuit supplying 125 V receptacles rated 20 A or less shall be protected by a combination-type arc-fault circuit interrupter, except for branch circuits supplying (i) receptacles installed in accordance with (A) Rule 26-710(f); or (B) Rule 26-712(d)((i), (iii), (iv), and (v); and (ii) a single receptacle for a sump pump where (A) the receptacle is labelled in a conspicuous, legible, and permanent manner identifying it as a sump pump receptacle; and (B) the branch circuit does not supply any other receptacles; and (g) notwithstanding Item (f), the entire branch circuit need not be provided with arc-fault protection where (i) an outlet branch-circuit-type arc-fault circuit interrupter is installed at the first outlet on the branch circuit; and (ii) the wiring method for the portion of the branch circuit between the branch circuit overcurrent device and the first outlet consists of metal raceway, armoured cable, or non-metallic conduit or tubing. by a listed arc fault circuit interrupter, combination-type, installed to 11 11

2012 vs. 2015 CE Code 2012 CE Code, Rule 26-722(f) Branch circuits that supply receptacles installed in sleeping facilities of a dwelling unit shall be protected by an arc-fault circuit interrupter 2012 CE Code 2015 CE Code 12 12

2015 CE Code AFCI Requirements Expansion within Dwelling Units Extended coverage to receptacles in other areas than bedrooms Typically includes: Living room, Hallways, Family room, Dining room, rec. rooms, closets. Expanded AFCI Options Combination type AFCI Circuit Breaker AFCI Receptacle installed at the first outlet box of the branch circuit, and use of conduit or armored cable to the first outlet 13 13

26-724(f) Combination-Type AFCI A combination type arc-fault circuit interrupter, installed to provide protection of the entire branch circuit. Combination AFCI Standard TR Receptacle 14 14

26-724(f) Combination-Type AFCI Advantages Protects the entire circuit from the source Disadvantages Legacy loadcenters may not accommodate AFCI circuit breakers No local AFCI reset 15 15

26-724(g) Armoured Cable or Conduit + OBC AFCI If metal raceway, armoured cable, or non-metallic conduit or tubing are installed for the portion of the branch circuit between the branchcircuit overcurrent device and the first outlet, it shall be permitted to install an outlet branch-circuit type AFCI at the first outlet to provide protection for the remaining portion of the circuit. Thermal Mag Circuit Breaker OBC AFCI Receptacle Armored Cable or Conduit 16 16

26-724(g) Armoured Cable or Conduit + OBC AFCI Advantages Allows for local AFCI reset at the receptacle Price advantage to AFCI Breaker Disadvantages Installation of conduit or armoured cable can be costly AFCI receptacle must be located at first outlet and be readily accessible 17 17

Other Considerations Location of the First Receptacle The AFCI receptacle must be placed as the first outlet. Care must be taken to ensure this location is readily accessible. Wiring Practices Because the AFCI receptacle must be placed in the first outlet, the contractor may need to change its wiring practices. 18 18

ONE EATON Eaton is the ONLY company that manufactures AFCI protection in both Circuit Breakers AND Receptacles. 19 19

The Last Word Remember your local Authority Having Jurisdiction has the ultimate say in the application and use of electrical equipment per the prevailing Electrical Code. Be sure to verify the local codes in your province or municipality. 20 20

Collateral/Supporting Documentation Whitepaper AFCI Sales Brochure Website www.eatoncanada.ca www.cooperwiringdevices.com Counter Display 21 21

Thank You TOGETHER WE CAN MAKE A DIFFERENCE 2008 Eaton Corporation. All rights reserved.