Cost-effective way to tailor anesthesia

Similar documents
PRODUCT SPECIFICATIONS VENTILATOR Aeros-4600

SPECIFICATION FOR MULTIPARAMETER MONITOR

OMNI TOUCH SCREEN PATIENT MONITOR

Omni (K) PATIENT MONITOR

Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation

LIFECARE PLV-100. by Bryce Younger

PATIENT MONITORING SYSTEMS

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

PATIENT MONITORING SYSTEMS

Oxylog VE300 Emergency & Transport Ventilation

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

1 Appendix - Product Specifications

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Oxylog 2000 plus Pocket Guide Software version 1.n

Meditec M700 Series Patient Monitors

From ventilators to vaporizers, we have all the anesthesia parts you need.

PATIENT MONITORING SYSTEMS

Product Specifications

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

DPM Summary of Features and Benefits

Menntor X7 Specification

CLEO VERSATILITY IN VITAL SIGNS

Quick start guide. English

PM 8050 Airway Monitor

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Getinge 8666/8668 Washer Disinfectors

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

Quick start guide. BiPAP AVAPS

DPM4 Bedside Monitor Default Settings

HOLTER RECORDER Product parameters

MRI Monitor. All-in-one monitor for the MRI environment. Features. Parameters. Accessories

Vitalmax 4000 CL Product Specifications

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP

OMNI Express VS VERSATILITY IN VITAL SIGNS

Multi-Parameter Patient Monitor

PM-9000 Express Portable Patient Monitor

MRI Patient Monitoring System (Model )

Important user information

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

Quick setup guide. English

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Puritan Bennett 980 Ventilator System Planning for Training Checklist

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

qube mini Overview

Ultraview SL2400 With Wireless-LAN-Option

OKM 801INFANT INCUBATOR

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

U S E R M A N U A L. Model: PM5900 SAVE THESE INSTRUCTIONS

Efficiency at Hand. Digital Radiography GF50 Series CT-GF EN. Tube 300kHU (210kJ) 150kHU (105kJ)

CARAT II. User's Manual Ventilator. as of device software Quality makes the Difference

7800 SERIES RM7888A Relay Module

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Med Touch Master Alarm

CARESTREAM DRX-Mobile Retrofit Kit

MIRUS TM Controller Instruction for use Software version

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

USER MANUAL. SAVE THESE INSTRUCTIONS (For latest revision, go to

7800 SERIES RM7888A Relay Module

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Gilian Air Sampling Products. The World s Most Reliable Air Sampling Equipment

www. szcomen. com COMEN - SHARE WITH THE WORLD

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

Medicontrol itcp Intelligent Theatre Control Panels

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

PRE AND POST VACUUM CLASS B AUTOCLAVE

740 SELECT. Multi-Parameter Monitor

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

Your Health, our Technology AWD655. Instrument Washer Disinfector

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

N-600. Pulse Oximeter Home Use Guide

Section PERIMETER SECURITY SYSTEMS

USER MANUAL. Model: PM5900. SAVE THESE INSTRUCTIONS (For latest revision, go to

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SOFTWARE VERSION 8.5 FAQs

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

Low Temperature Zirconia Oxygen Analyzer

N-600. Pulse Oximeter Operator s Manual

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

Tri-Tech Medical Inc.

CERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

T6 and T6R SMART THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Arla Tank Guard. Technical Specifications For Arla Tank Guard

AS950 REFRIGERATED SAMPLERS

laboratory & sterilization technology

VHP ARD BIODECONTAMINATION SYSTEM

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Neonatal Ventilator NV8

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

AS950 PORTABLE SAMPLERS

Transcription:

Cost-effective way to tailor anesthesia For over 20 years, Heal Force has been working closely with doctors and our industrial partners to develop advanced but affordable hardware and software, for optimizing perioperative anesthetic care and ancillary workflow. To further enhance effectiveness of anesthesia and reduce surgical cost, Heal Force launches the updated Anaeston anesthesia delivery system, which features advanced ventilation methods, comprehensive monitoring function and flexible expansion as needed, with which customers can start routine application with low capital investment and upgrade to workstation as tailored anesthesia requirements increase. Please visit www.healforce.com or contact our international distributors for more information about - Advanced but affordable anesthesia machine - Advanced anesthetic agent monitor - Sedation monitor for drug usage and ventilation guide - Computer-assisted clinical decision making program - High quality anesthetic consumables - IT solution to help optimize anesthesia and ancillary workflow

Anaeston 5000L Anesthesia workstation - High-precision fresh gas output down to 20ml - Automatic volume and compliance compensation - All major ventilation modes integrated (like VCV,PCV,PSV,SIMV+PS) - EEG-based assessment of anesthetic sedation - Spontaneous and manual respiratory MV monitoring - Audible and visual alarm with risk-priority indication and troubleshooting guide - Autoclavable and latex-free components - 12.1 external color TFT monitor - CE marked Cerebral State Monitor SIMV-VC+Pressure Support, CSM & EtCO2 Monitoring Dimension Driven mode Gas supply Input pressure O2 flush Power supply Batter backup Vaporizer Mount Agent type Patient type Tidal volume Ventilation mode Value Monitoring Graphic Monitoring 810x860x1360 mm (WxDxH) 110 kg Pneumatically driven, electronically controlled O2, N2O, Air 280~650 kpa 35~75 L/min 110/230VAC, 60/50HZ 60 minutes 2, Selectatec TM (Datex-Ohmeda s trademark) Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane Adult and pediatric 20~1500ml Manual, VCV, PCV, PLV, PSV, SIMV+VCV/PCV+PS Tidal volume, Minute Volume, Respiratory rate, I:E ratio Pmax, Pmean, Pplat FiO2%, EtCO2% (optional) CSI, SQI%,EMG% and BS% V-T, P-T, F-T curves. P-V, P-F, V-F loops Anesthetic depth and trend (including CSI, SQI%, EMG% and BS%) Alarm (Audible and visual alarm indication with diagnostic messages for trouble-shooting) Alarm silence 120 seconds High/low Vt, High/low MV, High/low Paw, High/low FiO2, High/low flow High/low cerebral state index (for anesthetic depth) Alarm content High/low EtCO2%, InCO2% and temperature (optional) Apnea alarm, Airway Malfunction, Power failure, Low battery and so on

Anaeston 3000P Anesthesia machine - High-precision fresh gas output down to 20ml - Automatic volume and compliance compensation - Manual, VCV,PCV,PLV ventilation - EEG-based assessment of anesthetic sedation - Spontaneous and manual respiratory MV monitoring - Autoclavable and latex-free components - Tool-free maintenance and cleaning - Built-in 8.4 color TFT monitor - CE marked Res. & Ins flow monitoring Medical CO2 absorbent, 980g / pack Dimension Driven mode Gas supply Input pressure O2 flush Power supply Batter backup Vaporizer Mount Agent type Patient type Tidal volume Ventilation mode Value Monitoring Graphic Monitoring 810x810x1360 mm (WxDxH) 96 kg Pneumatically driven, electronically controlled O2, N2O, Air 280~650 kpa 35~75 L/min 110/230VAC, 60/50HZ 60 minutes 1, Selectatec TM (Datex-Ohmeda s trademark) Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane Adult and pediatric 20~1500 ml Manual, VCV, PCV, PLV Tidal volume, Minute Volume, Respiratory rate, I:E ratio Pmax, Pmean, Pplat FiO2%, EtCO2% (optional) CSI, SQI%,EMG% and BS% (optional) V-T, P-T,F-T curves. P-V, P-F, V-F loops Anesthetic depth and trend (including CSI, SQI%,EMG% and BS%) (optional) Alarm (Audible and visual alarm indication with diagnostic messages for trouble-shooting) Alarm silence 120 seconds High/low Vt, High/low MV, High/low Paw, High/low FiO2, High/low flow High/low cerebral state index (for anesthetic depth) Alarm content High/low EtCO2%, InCO2% and temperature (optional) Apnea alarm, Airway Malfunction, Power failure, Low battery and so on

Anaeston 3000PS Anesthesia machine - Dual flow tube with precise output down to 20ml - Tidal volume compensation for low and minimal flow - Manual, VCV, PCV, PLV ventilation available - Autoclavable and latex-free components - Tool-free maintenance and cleaning - Built-in 5.7 monochrome TFT monitor - Reusable CO2 canister easy to refill and clean - CE marked Compact ventilator Medical CO2 absorbent, 4.5kg / pack Dimension Driven mode Gas supply Input pressure O2 flush Power supply Batter backup Vaporizer Mount Agent type Patient type Tidal volume Ventilation mode Value Monitoring Graphic Monitoring 810x810x1360 mm (WxDxH) 96 kg Pneumatically driven, electronically controlled O2, N2O 280~650 kpa 35~75 L/min 110/230VAC, 60/50HZ 60 minutes 1, Selectatec TM (Datex-Ohmeda s trademark) Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane Adult and pediatric 20~1500 ml Manual, VCV, PCV, PLV Tidal volume, Minute Volume, Respiratory rate, I:E ratio Pmax, Pmean, Pplat FiO2% P-T curve Alarm (Audible and visual alarm indication with diagnostic messages for trouble-shooting) Alarm silence 120 seconds High/low Vt, High/low MV, High/low Paw, High/low FiO2, High/low flow Alarm content Airway Malfunction, Power failure, Low battery and so on

Anaeston 3000C Anesthesia machine - Quick power-on self test - Highly maneuverable trolley with central brakes - Manual, VCV, PLV ventilation available - One-step switch from manual to mechanical ventilation - Spontaneous and manual respiratory MV monitoring - Tool-free maintenance and cleaning - Built-in 3 LCD and LED screen monitors - CE marked Operation interface Cylinder mount with Pin-index regulator Dimension Driven mode Gas supply Input pressure O2 flush Power supply Batter backup Vaporizer Mount Agent type Patient type Tidal volume Ventilation mode Value Monitoring Graphic Monitoring 810x634x1360 mm (WxDxH) 70 kg Pneumatically driven, electronically controlled O2,N2O 280~650 kpa 35~75 L/min 110/230VAC, 60/50HZ 60 minutes 1, Selectatec TM (Datex-Ohmeda s trademark) Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane Adult and pediatric 45~1500 ml Manual, Spont., VCV, PLV Tidal volume, Minute Volume, Respiratory rate, I:E ratio Pmax, Pmean, Pplat FiO2% P-T curve Alarm (Audible and visual alarm indication with diagnostic messages for trouble-shooting) Alarm silence 120 seconds High/low Vt, High/low MV, High/low Paw, High/low FiO2, High/low flow Alarm content Apnea alarm, Airway Malfunction, Power failure, Low battery and so on

Cerebral State Monitor (CSM) - A new standard for consciousness monitoring during anesthesia - Tailored anesthesia with $ 5~10 investment per surgery What is CSM? A new small handheld electroencephalogram (EEG) monitor for assessment of anesthetic sedative properties. Why CSM? Due to individual variation and stimulation during surgery, patients need different amount of anesthetic agent to sleep. Incorrect usage of drug or bad surgical condition determination, from time to time, will result in anesthesia awareness, over-sedation, or longer recovery time and higher surgery cost. However, it s very complex, then very hard to give simultaneous interpretation to sleep level with direct logical modelling, especially when muscle is paralysed. CSM uses fuzzy logic system to deal with uncertainty of EEG wave changes in engineering by attaching degrees of certainty to the answer to a logical question, and interpret quantitatively with scale 0~100, which will help achieve successful delivery of effective, safe and economical anesthesia: With CSM, anesthesiologist will benefit from With CSM, patient will benefit from - Quantitative assessment of consciousness - Lower risk of anesthesia awareness or over-sedation - Optimal surgical condition determining - Shorter recovery time - Optimal drug usage - Lower surgery cost How dose CSM work? Step 1 CSM electrode positioning Electrode Color White Green Black Position* Middle forehead Left forehead Left Mastoid Electrode Type Positive Reference Negative *Electrodes can also be placed on the right side of the head Anesthetic Concentration CSI 100 60 40 0 EEG waves Induction Incision with? inadequate analgesia Emergence Step 2 EEG measurement of brain activity (Alpha ratio, Beta ratio, Beta ratio-alpha ratio, Burst Suppression %) Step 3 EEG signal processing with Fuzzy logic system Step 4 Signal output and Quantitative interpretation CSI value 90-100 80-90 60-80 40-60 10-40 0-10 Clinical State Awake Drowsy Light anesthesia Surgical anesthesia Deep anesthesia (mostly accompanied by Burst Suppression Close to coma (when CSI is below 3, the EEG is practically iso-electric.

How to use CSM? - Stand-alone operation - To patient monitor (via wireless integration) - To anesthesia machine (via wireless integration) - Hand-held size - Multi-parameter EEG waveform displayed - Event labeling - Latex-free components - CSM Link Software for case documentation - Cerebral State Index (CSI) of 0-100 displayed on all screens - Rechargeable battery for 18-hour nonstop usage - Stand-alone operation or wireless integration to other equipments EEG sensitivity Noise CMR Input impedance Sample rate CSI and update EMG BS% Digital output Wireless range Display size Alarms Artefact rejection Sensor impedance range Battery Supply current Battery lifetime: Alkaline/ Rechargeable Dimensions Classification Sensors Cable length Mounting options Memory Monitor language Environment: Operation Environment: Transport and storage ±400μV < 2μVp-p, < 0.4μV RMS, 1 250 Hz >140dB >50MΩ 2000 samples/sec. (14 bits equivalent) 0-100. Filter 6-42 Hz, 1 sec. update 0-100 logarithmic. Filter 75-85 Hz, 1 sec. update 0-100%. Filter 2-42 Hz, 1 sec. update Wireless to RS232 link (ISM 2.4 GHz) Up to 10 meters 32x17 mm High / Low with user selectable limit Automatic 0-10kΩ / measurement current 0.01μA 9V Alkaline or rechargeable* NiMH (6AM6/IEC:6LR61/ ANSI:1604A ) 25mA (typical) 32h (stand alone) 18h (transmitting wireless) 12h (stand alone) 8h (transmitting wireless) 130 g with battery 114x60x31 mm (L W D) Internal power supply/ Class II, type BF, continuous use Danmeter Neuro Sensors 195 cm/77 with 35 cm/14 split Velcro strip (42mm x 25mm) Data recording 18 hours English, Spanish, French, Greek, Italian, Dutch, Norwegian, Portuguese, Finnish, Swedish, Danish, German Temperature 10 40 C/50 104 F Rel. humidity 30 75% Air pressure 700 1060 hpa Temperature 10 40 C^/50 104 F Rel. humidity 30 95% Air pressure 700 1060 hpa All specifications and figures are ANESTHESIA MACHINE