SN2003, SN2023, SN2004, SN2024

Similar documents
SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

Express Lavatory System MG-Series

Express Lavatory System MG-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

Installation Instructions

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

LVQD3 Verge with WashBar Technology LVQ-Series

LVSD2 Verge Wash Basin LVS-Series

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

AV60 Advocate Lavatory System AV-Series

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Installation Instructions

AV60 Advocate Lavatory System AV-Series

Installation Instructions

Installation Instructions

Washfountain Application Guide

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

AV90 Advocate Lavatory System AV-Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Installation Instructions

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

LVSD2 Verge Wash Basin LVS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

HL45, HL80 Thermostatic High-Low Valves

LVQD3 Verge with WashBar Technology LVQ-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

LVQD1 Verge with WashBar Technology LVQ-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

LD-5010 OmniDeck with WashBar 5000 Series

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation Instructions

FAUCET PARTS - EXPLODED VIEW Model: K-59

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

TMV45 & TMV80 Standard Thermostatic Mixing Valves

Durability within reach

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation Instructions OBSOLETE

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

LA45 DISCONTINUED IMPORTANT!

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

cygnet stainless Product Catalog toll free

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

LA60 DISCONTINUED IMPORTANT!

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Wall Mounted Shower Systems

DESIGN AND CONSTRUCTION STANDARDS July 2011

School Solutions Ideabook

Bobrick - Washroom Accessories. Conversion Chart

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

FL-3H, FL-3L Frequency Lavatory System FL-Series

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

LA90 DISCONTINUED IMPORTANT!

Series Barrier-Free Water Coolers

Product Specification

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

A. Section Joint Sealants: Seal fixtures to walls and floors.

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Installation Instructions

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

DV The clean solution. Special Features: Standard Features: Options: HOT WATER SANITIZING DOOR-TYPE DISHWASHER

Transcription:

Reliable Push Button Activated Air Metering or Infrared Control Available in a 54" or 36" Bowl Size Wall-Mounted or Floor-Mounted Standard Height Model with Hand or Infrared Control Is ADA Compliant Factory Tested and Shipped Preassembled Vandal Resistant and Easy to Clean Specifi cations Size and Capacity Accommodates 3 users (36" models) or 4 users (54" models) at a time, using less water, energy and space than lavs equipped with conventional faucets. The sectional sprayhead module is controlled by a push button, which actuates an air valve (hand or foot control models), or an infrared sensor-actuated solenoid valve. Flow restrictor keeps flow rate constant at 0.5 GPM per station for all pressures. Operating range is 20-80 PSI. SN2004/IR SN2004/AST4/BS Construction Bowl and Pedestal All exposed materials are type 304 stainless steel polished to a #4 finish. Bowl, pedestal and access panels, frame, foot control housing; support tube; and sprayhead are heavy gauge stainless steel. Exposed fittings are chrome plated. Vandal Resistance Bowl and support tube are an integrally welded assembly, with the support tube welded to an extruded flange from bowl. Sprayhead nozzles and push buttons/infrared sensors are secured to unit from inside the sprayhead module. Air valves/solenoid valves are safely concealed inside the washfountain. Access panels are removable. All supply and waste connections are concealed within the pedestal. Code Compliance and Certifi cations UPC Approval Sentry TM Washfountains are Uniform Plumbing Code (UPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Barrier-Free (ADA Compliant) Standard Height Models Only Wall-mounted models (when mounted at standard height) and standard height floormounted models with hand or infrared control are designed to comply with all ADA guidelines on reaches, clearances and operation. Standard Equipment Valves and Fittings In addition to the bowl and pedestal, the following valves and fittings are standard: manual mixing valve, check stops and strainers. Check valves are 1/2" NPT female. Activation Controls Air Valve Hand Control (AST4) Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates one valve which, in turn, activates one station. Push button requires less than five pounds of pressure. C U P C Page 1 of 7 R SN2004/AST4-F/STD Models (Must select one) Model, Size, Stations Description Model, Size, Stations Description SN2003* 36" 3 Floor-Mounted SN2023* 36" 3 Wall-Mounted SN2004* 54" 4 Floor-Mounted SN2024* 54" 4 Wall-Mounted Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with supplies from above Controls (select one) AST4 Hand Control Metering Air Valve IR Infred Activation H O Centrally rising vent with supplies from below Off-line vent with supplies from above AST4-F Foot Control Hold-Open Air Valve ** Pedestal Height (Models SN2003 & SN2004 only) (select one) STD Standard Pedestal Height JUV Juvenile Pedestal Height Supply Fittings (select one) TMA Thermostatic Mixing Valve PBV Pressure Balance Mixing Valve TL Tempered Line Supply Soap Dispenser (select one) LSD Liquid Soap Dispenser NSD No Soap Dispenser Backsplash (select one) BS Backsplash NBS No Backsplash Optional Selections Paper Towel Dispensers CTD (2) C-Fold, Multi-Fold Dispenser Stainless Steel Shroud SH Stainless Steel Shroud (Conceals overhead plumbing) SFTD (2) Single-Fold Dispenser * These models in standard height with AST4 or IR controls are ADA compliant. ** Non-cancelable, not-returnable.

Air Valve Foot Control (AST4-F) Each push button pneumatically actuates a hold-open air single temperature valve with slow closing upon release of foot pressure. Push button requires less than five pounds of pressure. Infrared Control (IR) Each of the stream formers is controlled by a separate solenoid valve. Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from one spray nozzle. Shut-off is automatic after hands are removed from the detection area. The infrared sensor module uses two zone-focused infrared transmitting beams, having a detection area adapted to, but not exceeding, the bowl perimeter. The Rough-In Dimensions for Bowl and Pedestal Wall Anchors detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transform as standard equipment: Solenoid 24V, 50/60 Hz, 3/ NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Transformer Class II UL/CSA listed, 110/24 VAC plug-in transformer. Plugs into a standard GFCI protected electrical outlet. Location of transformer per local electrical code. 36: 13-3/ (340) 54: 22-3/ (568) 36: 13-3/ (340) 54: 22-3/ (568) 32-1/2"* (826) 4" (102) 1-3/4" (44) 4" (102) 24-3/4"* (629) 110 Volt Electrical Box for Units with IR Activation (Recommended Location; See Local Electrical Codes Before Roughing in) 8-3/ JUV STD Floor Mounted Only 8-3/ JUV STD Floor Mounted Only Floor Mounted Only 4-3/4" (121) 14-3/4"* (375) 14-1/2"* (368) Rough-In Notes Anchor locations for 3/ diameter bolts, both supplied by installer. Wall mounted 54" and 36" models with Infrared or hand control are ADA compliant when mounted at standard height dimensions. Page 2 of 7 11-12-2008

Dimensions - Sentry TM 54" Floor Mounted Infrared Control with Hand Control 2* 2* 16-3/ 25-1/4" (641) 16-3/ 25-1/4" (641) Foot Control 8-11/16"* (221) 2-1/4" (57) 25-1/4" (641) 4-1/ (105) Standard height 54" models with Infrared or hand control are ADA compliant when mounted at standard height dimensions. Page 3 of 7

Dimensions - Sentry TM 36" Floor Mounted Infrared Control with Hand Control Foot Control 3-1/16"* (81) 2-1/4" (57) 17" (432) 3-15/16" (100) Standard height 36" models with Infrared or hand control are ADA compliant when mounted at standard height dimensions. Page 4 of 7 11-12-2008

Dimensions - Sentry TM 54" and 36" Wall Mounted 54" Infrared Control with 54" Hand Control 2* 2* 16-3/ 35-1/4" (895) 16-3/ 35-1/4" (895) 36" Infrared Control with 36" Hand Control 2* 2* Wall mounted 54" and 36" models with Infrared or hand control are ADA compliant when mounted at standard height dimensions. Page 5 of 7

Rough-In Dimensions for Drain and Supplies Type A Off-line vent with supplies from below 2-3/4" (70) 1/2" NPT Supplies 5" (127) 5" (127) Through Floor: Stub Up 3" (76) (Optional) Centerline of Washfountain 4-1/2" (114) 1/2" NPT Supplies Through Floor: Stub Up 2-1/2" (64) (Optional) : Stub out to Suit Trap Type B Centrally rising vent with supplies from above 2-3/4" (70) Through Floor: Stub Up 3" (76) (Optional) 36: 7-9/16" (192) 54: 8-1/16" (205) 36: 54: 9-1/4" (235) 1/2" Nom. Copper Tube Supplies from Above Must Be Located on These Centers to Pass Through Washfountain Shroud and Sprayhead 1/2" NPT Supplies Centerline of Washfountain 1/2" NPT Supplies from Above Vent from Above 1/2" NPT Supplies Supplies and Drain Through Floor (Optional) ** : Stub out to Suit Trap Drain Through Floor (Optional) ** Std: 12" (305) Juv: ** Floor Mounted Units Only Type A Drain Supplies below Off-drain vent P-Trap furnished by others Type B Drain Supplies above Centrally-rising vent P-Trap furnished Rough-In Notes 1. Maximum flow rate required to washfountain is 1.5 GPM for Models SN2003 and SN2023 or 2.0 GPM for Model SN2004 and SN2024. Size supply lines accordingly. 2. Unit with A" drain and paper towel dispensers and/or a shroud, should use H" drain Rough-Ins. Page 6 of 7 11-12-2008

Rough-In Dimensions for Drain and Supplies Type H Drain Centrally rising vent with supplies from below Through Floor: Stub up 3" (76) (Optional) 1/2" NPT Supplies 5" (127) 36: 54: 9-1/4" (235) 2-3/4" (70) 1-1/2" NPT Vent from Above 4-1/2" (114) 4-1/2" (114) Centerline of Washfountain 1/2" NPT Supplies Through Floor: Stub up 2-1/2" (64) (Optional) Vent from Above Type O Drain Off-line vent with supplies from above Through Floor: Stub up 3" (76) (Optional) 2-3/4" (70) 1/2" Nom. Copper Tube Supplies from Above Must Be Located on These Centers to Pass Through Washfountain Shroud and Sprayhead 5" (127) 36: 7-9/16" (192) 54: 8-1/16" (205) Centerline of Washfountain 1/2" NPT Supplies from Above Through Wall: Stub out to Suit Trap 1/2" NPT Supplies Supplies and Drain Through Floor (Optional) ** Through Wall: Stub out to Suit Trap Drain Through Floor (Optional) ** Std: 12" (305) Juv: ** Floor Mounted Units Only Type H Drain Supplies below Centrally-rising vent P-Trap furnished Type O Drain Supplies above Off-drain vent P-Trap furnished by others Rough-In Notes 1. Maximum flow rate required to washfountain is 1.5 GPM for Models SN2003 and SN2023 or 2.0 GPM for Model SN2004 and SN2024. Size supply lines accordingly. 2. Unit with "O" drain and paper towel dispensers and/or a shroud, should use "B" drain Rough-Ins. Page 7 of 7