TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

Similar documents
DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

standard response large orifice dry

standard response/ quick response extended coverage

standard response dry horizontal sidewall sprinklers

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

Standard response. elo sprinklers

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

TECHNICAL DATA OBSOLETE

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

TECHNICAL DATA. Page 1 of 6

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

December 14, 2015 Page 1 of 7 TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

Microfast quick response Fusible element hsw sprinkler

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response fusible link sidewall sprinkler VK112 (K5.6)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

standard response Fusible Link Upright sprinkler VK204 (K8.0)

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

microfast quick response Pendent sprinkler VK302 (K5.6)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard/quick response extended coverage light and ordinary hazard elo sprinklers

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

standard response elo upright and pendent sprinklers (storage-density/area)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

micromatic standard response Upright sprinkler VK100 (K5.6)

standard response elo upright sprinkler

micromatic Standard response Horizontal Sidewall sprinkler

microfast quick response extended coverage hsw sprinkler vk606

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

microfast and microfasthp quick conventional sprinklers

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

micromatic standard response stainless steel sprinklers

TECHNICAL DATA vk470 (K3.0)

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

Transcription:

September 6, 2012 Sprinkler 103a 1. DESCRIPTION Viking are suitable for use in areas subject to freezing. They may be installed either upright or pendent, and are suitable for use on dry systems, preaction systems, or wet systems. They are ideal for use in unheated spaces above ceilings of heated rooms equipped with wet pipe sprinkler systems. Viking Standard Response Dry Vertical Sidewall Sprinklers are available in various finishes and temperature ratings to meet design requirements. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. 3. technical data Specifications: Available since 1994. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1 NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all standard lengths. * Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: UNS-C31400 or UNS-C31600 Brass Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Ordering Information: (Also refer to the current Viking price list.) (Not Listed or Approved) Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Order Standard Response Dry Vertical Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ( A or B dimension) to sprinkler base part number. Order in a specific length noted as the A or B dimension (see Figures 4 through 6). For Adjustable Recessed or Adjustable Standard Dry Vertical Sidewall Sprinklers, the A dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. for Plain Barrel Dry Vertical Sidewall Sprinklers, the B dimension is the distance from the face of the fitting (tee) to the top of the deflector. These are available in lengths from 3 to 45-1/2 (76.2 mm to 1,156 mm) for the adjustable standard style, 4-1/2 to 47 (114.3 mm to 1,194 mm) for the plain barrel style, and 3-1/4 to 47-1/2 (82.5 mm to 1,207 mm) for the adjustable recessed style. Finish Suffix: Brass = A, Chrome-Enloy = F, and White Polyester = M-/W Temperature Suffix: 155 F (68 C) = B, 175 F (79 C) = D, 200 F (93 C) = E, 286 F (141 C) = G For example, sprinkler VK157 with 1 NPT Threads, a Chrome finish and a 155 F (68 C) temperature rating, and A length of 10 = Part No. 09123UFB10. Form No. F_011194 Replaces page 103a-f, dated March 19, 2010. (Revised Pip Cap materials.)

Sprinkler 103b September 6, 2012 Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed : Part No. 07565W/B** (available since 1991) **A ½ ratchet is required (not available from Viking). Dry Sprinkler Protective Cover: Part No. 15610 Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a semi-circular spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability The Viking Standard Response Dry Vertical Sidewall Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 07297W/B

September 6, 2012 Sprinkler 103c Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Bulb Color Ordinary 155 F (68 C) 100 F (38 C) Red Intermediate 175 F (79 C) 150 F (65 C) Yellow Intermediate 200 F (93 C) 150 F (65 C) Green High 286 F (141 C) 225 F (107 C) Blue Sprinkler Finishes: Brass, Chrome-Enloy (patents pending), and White Polyester 1 The sprinkler temperature rating is stamped on the deflector. Footnotes 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry VSW Sprinklers

Sprinkler 103d September 6, 2012 Sprinkler Base Part SIN Style Number 1 Approval Chart Standard Response Dry Vertical Sidewall Sprinklers Maximum 175 PSI (12 bar) WWP Thread Size Nominal K-Factor 2 Order Length Increment Listings and Approvals 4 NPT BSP U.S. metric 3 Inches mm culus FM NYC VdS LPCB 09123U VK157 Adjustable 1 -- 5.6 -- 1/2 12.7 -- -- -- -- -- -- -- 08961U VK157 Standard -- 25 mm -- 80.6 1/2 12.7 -- -- -- -- -- -- -- 09124U VK161 Adjustable 1 -- 5.6 -- 1/4 6.35 -- -- -- -- -- -- -- 08962U VK161 Recessed -- 25 mm -- 80.6 1/4 6.35 -- -- -- -- -- -- -- 09125U VK153 Plain 1 -- 5.6 -- 1/2 12.7 -- -- -- -- -- -- -- 08963U VK153 Barrel -- 25 mm -- 80.6 1/2 12.7 -- -- -- -- -- -- -- Available Temperature Ratings A - 155 F (68 C), 175 F (79 C), 200 F (93 C), and 286 F (141 C) for the Adjustable Standard and Plain Barrel Styles B - 155 F (68 C), 175 F (79 C), and 200 F (93 C) for the Adjustable Recessed Style Available Finishes and A and B Dimensions 1 - Chrome-Enloy or White with A dimensions 3 to 45-1/2 (76.2 mm to 1 156 mm) for the Adjustable Standard Style 2 - Chrome-Enloy or White with A dimensions 3-1/4 to 47-1/2 (82.5 mm to 1,207 mm) for the Adjustable Recessed Style 3 - Chrome-Enloy or Brass with B dimensions 4-1/2 to 47 (114 mm to 1,194 mm) for the Plain Barrel Style Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ( A and B Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 4 Viking are NOT listed or approved. NOTE: When using CPVC fittings with Viking dry, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

September 6, 2012 Sprinkler 103e Figure 3: Adjustable Standard Dry VSW Sprinkler Figure 4: Adjustable Recessed Dry VSW Sprinkler

Sprinkler 103f September 6, 2012 Figure 5: Plain Barrel Dry VSW Sprinkler Form No. F_011194 Replaces page 103a-f, dated March 19, 2010. (Revised Pip Cap materials.)