Earth-Rite II PLUS Static Earthing System

Similar documents
Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

official distributor of Newson Gale Ltd.

Newson Gale. Cen-Stat Static Grounding clamps, cables and reels. Leading the way in hazardous area static control. IECEx

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION & SERVICE MANUAL

srra, of Conformity IECEx Gert f cate ?-ot,b

4) Intrinsic Safety Certification

OPTIBAR DP 7060 Supplementary Instructions

Operating Instructions

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Flameproof Manual Call Points

INSTRUCTION MANUAL (ATEX / IECEx)

OPTIBAR P 1010/2010 C Supplementary instructions

SET Installation and Operating Instructions. Level switch for one sensor

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

standards: standards:

Grounding & Bonding Applications

OPTIWAVE X500 Supplementary Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Electrical Installations Design, Selection, Erection and Inspection

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

VERSAFLOW VORTEX Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SET-2000 Oil/Sludge 12 VDC

Certificate of Compliance

Technical Data. Dimensions

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Technical Data. Dimensions

UL HAZARDOUS LOCATIONS SERVICES

Certificate of Compliance

Certification Supplement Manual

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

HYTEK ATEX APPROVED TANK ALARM

Manual Power relay SR853

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

LC3000 Level Controller Installation and Maintenance Instructions

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Guide for hazardous areas

14300 MAINS SEPARATOR ALARM MANUAL

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

E2S Datasheet v10a

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX)

Inductive slot sensor

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Universal Tank Alarm Type Installation, Operation & Maintenance

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Survey of electrical equipment installed in hazardous areas on tankers

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Certification Supplement Manual

IECEx Certificate of Conformity

Technical Data. Dimensions

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

RE-PR3-E-27 3-Phase Panel Mount 27kW

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

IECEx Certificate of Conformity

SET-2000 Hi Level/Oil

Fixed Gas Detection System/Meridian CERTIFICATION

OilSET-1000 (12 VDC)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

IECEx Certificate of Conformity

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Dräger Polytron 8310 IR Detection of flammable gases and vapour

DESCRIPTION. 42 mm. 125 mm

AND INSTALLATION MANUAL

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Approved by: Document no.: EGT

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

MAN0604_Issue 09_ Apex

Dräger Polytron 8310 Stationary gas detector (DSIR)

Explosion-proof Immersion Heater Type D-8660

Dräger Polytron 8200 Stationary gas detector (CatEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Technical Data. Dimensions

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Annubar Flowmeter Series

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Transcription:

READ MANUAL BEFORE COMMENCING WITH INSTALLATION EN Earth-Rite II PLUS Static Earthing System P1 PLUS - DC Supply Installation & Operating Instructions The safety of any system incorporating the equipment referred to in this manual is the responsibility of the installer of the system. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Any warranty is made void if the equipment is not installed, or used, in accordance with the manufacturers instructions. 1

Earth-Rite II P1 PLUS DC Static Earth Monitoring System Terminology used in this manual Single Mode The Earth-Rite II PLUS system operates using Single Mode technology which monitors the complete resistive loop from plant item to the designated site Static Earth Bar or Tape. PLUS System: The Earth-Rite II has been supplied as a Singlemode system (resistive monitoring), it is intended for use with any conductive material item such as a drum, mixing vessel, rail tanker etc. It is set to show permissive only when the system detects that the connection to the plant item, and to earth, is less than 10 Ohms nominal resistance. Until this condition is achieved, the system remains non-permissive. Installation The installation shall be carried out by suitably trained personnel in accordance with the relevant sections of IEC 60079 and EN 60079. All cables entering the monitoring unit must be connected through approved cable glands in accordance with EN 60079-14. The glands should be fitted in such a way as to maintain the ingress protection rating of the enclosure. The system should be connected as per the enclosed installation drawings. The Earth-Rite II Monitoring Unit should be powered from a supply voltage of 1 to 4V DC. The unit should be protected using a A fast blow fuse mounted in the distribution board / fuse box. The monitoring unit should be mounted, with the indicator window facing away from direct sunlight, at a convenient location, visible to the operator. Customer Supplied Cable Specification Recommended Specification Cable from ERII Control Unit to ERII Junction Box 1.0mm core Cable with blue sheath or identifier (IS Circuit). Cable from ERII Unit to Pump Starter 1.0mm core cable + Protective Earth Cable from Supply to the ERII Unit 1.0mm core cable + Protective Earth Cables from ERII Unit to Site Static Earth Bar or Tape 4mm single core cable with green sheath. Unused entries must be fitted with approved stopper plugs. NOTE: Cables must be secured close to the enclosure in order to prevent them being accidentally pulled out. Other Approvals Functional Safety The Earth-Rite II has been given a SIL (Safety Integrity Level) rating of. Electromagnetic Compatibility The Earth-Rite II has been tested and shown conformity to European Directive 004/108/EC, and FCC Part 15 Emissions. Conformity has been proven to BS EN 61000-6-3 and BS EN 61000-6-. After installation of wiring, secure the cover to the body making sure it is fully tight. Note: It is recommended that the transfer or mixing operation is interlocked with the contacts of the Earth-Rite II unit. This will ensure that the operation is stopped if the earth connection is inadvertently lost. Maintenance: Periodically check exterior of enclosure for damage or deterioration. IF YOU HAVE ANY QUERIES REGARDING THE ABOVE POINTS THEN PLEASE CONTACT NEWSON GALE, OR THEIR APPROVED DISTRIBUTOR, WITHOUT DELAY.

Troubleshooting at the time of Installation Earth-Rite II PLUS - Single Mode System Before contacting Newson Gale please check the following points:- Symptom: Red and/or Green LEDs are NOT showing Check that the system is installed in accordance with the supplied manual. Check that there is power to the monitoring unit, and that it is the correct voltage. Caution - Ensure all Health & Safety precautions are taken during the above procedures. Symptom: System is NOT switching to permissive state when clamp is fitted to conductive plant items (RED LED continues to show). Check that the system is installed in accordance with the supplied manual. Check That the Earthing Clamp is in good condition: that the contacts are level with each other, sharp and not loose. Caution - Ensure all Health & Safety precautions are taken during the above procedures. If the system still does not switch to permissive state when clamp is fitted to the plant item please contact Newson Gale and confirm the following:- Serial number Company which ordered the system Date of order Any other information 3

Earth-Rite II PLUS P1 DC Cable Connections - Terrestrial Version Earth-Rite II P1 PLUS Crimp Connector +v 0v PL1 sw G1 G C1 C PL PL3 PL4 Upper (Monitoring) PCB 1 Lower (PSU) PCB Crimp Connector PL3 PL1 nc c no no c nc PL 0V 0V +VE Ferrite Bead Protective Earth (PE) Conductor 1 Customer Interlock Circuits - + 10-30Vdc Supply Non-Intrinsically Safe Wiring SITE STATIC EARTH BAR / TAPE Verified Static Earth Point (Resistance to Earth must be <10 ohm) Zone 1,, Zone 0, 0, 1, 1,, Junction Box Quick Connect Earthing Clamp Verification of the Static Earth Point The system monitors the static dissipation path, from the object to which the Static Earth Monitoring Clamp is connected, as far as the Static Earth Bar or Tape. The Static Earth Bar/Tape, and Static Earth Point, should be close to the working area. It is the responsibility of the end user to provide the Static Earth Point and ensure that it is suitable for dissipating electrostatic charges. Reference to ATEX 014/34/EU, ATEX 137, EN 60079-14, IEC TS 60079-3-1, CLC/TR: 60079-3-1, or other applicable international standard, will give guidance on the installation of a suitable Static Earth Point. 4

for Ferrite Bead Fitting Instructions Earth-Rite II P1 & P DC Systems Lower (PSU) PCB PL3 PL1 nc c no no c nc PL DC 0 DC 0 DC + Ferrite Bead Earth-Rite II Enclosure 10-30Vdc Supply Cable or Conduit 5

EARTH-RITE II SYSTEM Component Identification Earth-Rite II PLUS MONITORING PCB VAC - FORM INSULATING COVER DC POWER SUPPLY Internal Component Assembly Avoiding Electrostatic Discharge (ESD) damage to the ERII monitoring PCB /Card Always take precautions to ensure that you are not electrostatically charged whilst handling the monitoring PCB / Card. Always handle the PCB / Card by the edges, or terminal block, and avoid touching the components. When not fitted inside the ERII enclosure, always keep the PCB / Card in the static dissipative bag provided. Always observe precautions against damage to the PCB s from electrostatic discharge. 1. Remove the lid of the enclosure and remove the blue approval label. This can be achieved by unscrewing the lefthand screws 4 revolutions anti-clockwise and removing the right-hand screw completely.. Disconnect the three wires of the ribbon cable from the terminal block. Remove the monitoring PCB by unscrewing the three hexagonal metal pillars. Place the PCB in the anti-static bag provided and keep it safe. 3. Remove the vac-form insulating cover. 4. Install the various cables into the enclosure using suitable glands and/or conduit. Make the connections to the Power Supply PCB. 5. Replace the vac-form insulating cover. 6. Replace the monitoring PCB and secure using the three hexagonal metal pillars. Reconnect the ribbon cable and make the external I.S. wiring connections into the Terminal block. 7. Replace the blue approval label and secure using the screws provided. Replace the lid of the enclosure securely. 6

Intrinsically Safe PCB Connections Monitoring PCB INTERNAL CONNECTIONS TO LOWER (PSU) PCB +v 0v PL1 sw PL Upper (Monitoring) PCB SITE STATIC EARTH BAR / TAPE CLAMP VIA JUNCTION BOX G1 G C1 C PL3 PL4 Power Supply PCB INTERNAL CONNECTIONS TO UPPER (MONITORING) PCB +v 0v sw PL4 Lower (Power Supply) PCB - DC 1 PL PL3 PL1 nc c no no c nc 0V 0V +VE 7

Operation Important Note: The Clamp should be fitted prior to fitting hoses, or any other operation as per the recommendations of IEC TS 60079-3-1, CLC/TR: 60079-3-1, NFPA 77 and API RP 003. ERII Junction Box A. In the normal "rest" state, with the Earthing Clamp stowed on the insulated pin, the Condition LED will be showing. Red Negative Earth Clamp B. Attach the Earthing Clamp onto the conductive plant item at a suitable point and ensure that the pointed contacts are positively located. If the connection to the plant item and Earth is good, the Green Positive Earth Condition LEDs will flash and the interlock contacts will close. Drum The product transfer / mixing operation can now take place. C. If the connection between the plant item and Earth is broken during the transfer / mixing operation, the Red Negative Earth Condition LED will show and the interlock contacts will open. X ERII Junction Box Clamp D. On completion the Earthing Clamp should be removed from the plant item and stowed on the insulated pin on the front of the junction box. The Earth Condition LED will show. Red Negative 8

Earth-Rite ERII Dimensions Monitoring Unit FRONT VIEW WITH LID IN PLACE B E SIDE VIEW WITH LID IN PLACE C A F FIXING HOLE DIAMETER D Junction Box FRONT VIEW WITH LID IN PLACE B SIDE VIEW WITH LID IN PLACE C A FIXING HOLES ARE ACCESSIBLE WHEN THE LID IS REMOVED F STOWAGE PIN E FIXING HOLE DIAMETER D PRODUCT DESCRIPTION Junction Box with Stowage Pin MAIN DIMENSIONS A mm B mm C mm 75 80 57 FIXING DIMENSIONS D mm E mm F mm Earth-Rite II P1 Monitoring Unit 160 160 94 1 X 7 140 140 4.5 68 45 9

Earth-Rite II - DC Technical Specification Monitoring Unit Power supply Power rating Ambient temperature range Ingress protection Weight Construction Certification Monitoring circuit Operational series ground resistance Output Relay contact rating Cable entries Junction box/stowage point Enclosure Terminals Stowage device Cable entries Clamp Cable Connection Earthing clamp Clamp design Body Spiral Cable Cover Conductors Length 1/4V dc (Supply voltage range: 10V to 30V dc) 10 watt o o -40 C to +55 C IP66 4.5 kgs (nett) Static Dissipative Glass-Reinforced Polyester Ex na nc [ia] IIC T4 Gc(Ga) Ex tb IIIC T70C Db Intrinsically safe </= 10 Ohm off voltage free change-over switch contacts, 50Vac, 5A, 500VA max resistive 30Vdc, A, 60W max resistive 7 x M0 ( x plugged) GRP with carbon loading x.5mm conductor capacity Insulated pin 1 x M0 Quick Connect pole with tungsten carbide contacts Stainless steel Blue Cen-Stat Hytrel sheath (Static dissipative, chemical & abrasion resistant) x 1.00mm copper 10 metres extended, 1 metre unextended (other options available) NB: In line with our policy of continual product development, we reserve the right to alter specifications at any time. 10

11

User instructions in compliance with IEC 60079-0:007 clause 30 The following instructions apply to the Earth-Rite II Earth Monitoring Unit, Ex na nc [ia], covered by certificate numbers IECEx SIR 09.0097 and Sira 09ATEX47. Instructions for safe selection, installation, use, maintenance and repair The equipment may be used in zones, 1 and with flammable gases and dusts. The equipment may be used in the presence of flammable gases and vapours with apparatus groups IIC or IIB or IIA and with temperature classes T1 or T or T3 or T4. The equipment may be used in the presence of flammable dusts, powders and flyings, conductive or non-conductive, the only limitation being the maximum external surface o temperature of 70 C. The equipment is certified for use in ambient temperatures in o o the range of 40 C to +55 C and should not be used outside this range. Certification Label Detail 0518 Ex na nc [ia] IIC T4 Gc(Ga) Ex tb IIIC T70C Db IECEx SIR 09.0097 Ta = -40 C to +55 C (Um = 50V) Newson Gale www.newson-gale.com Earth-Rite ER II Static Earthing System II 3(1)G II D Sira 09ATEX47 IP66 SEE SUPPLEMENTARY LABEL FOR PRODUCT CODE, SUPPLY VOLTAGE, SERIAL NUMBER AND YEAR OF MANUFACTURE HAZARDOUS LIVE PARTS DO NOT OPEN THE ENCLOSURE WHILE ENERGISED Nottingham, NG4 JX UK The equipment is to be installed by suitably trained personnel in accordance with the applicable code of practice (typically IEC/EN 60079-14) No user adjustment is required. Earth-Rite ER II Product Code = CCC Serial Number: YY/xxxxx Supply Voltage. VVV NOTE: CCC = PLUSP1ED YY = Year of Manufacture XXXXX = Specific Serial Number vvvvv = 1-4Vdc Regular periodic inspection of the equipment should be performed by suitably trained personnel in accordance with the applicable code of practice (typically IEC/EN 60079-17) to ensure it is maintained in a satisfactory condition. The equipment is not intended to be repaired by the user. Repair of the equipment is to be carried out by the manufacturer, or their approved agents, in accordance with the applicable code of practice. The equipment contains no user-replaceable parts. Verification of the Static Earthing Point The system monitors the static dissipation path, from the object to which the Static Earth Monitoring Clamp is connected, as far as the Site Static Earth Bar or Tape. The Static Earth Bar/Tape, and Static Earth Point, should be close to the working area. It is the responsibility of the end user to provide the Static Earth Point and ensure that it is suitable for dissipating electrostatic charges. Reference to ATEX 014/34/EU, ATEX 137, EN 60079-14, IEC TS 60079-3-1, CLC/TR: 60079-3-1, or other equivalent international standard, will give guidance on the installation of a suitable Static Earth Point. The above does not apply to any system used to monitor a bond connection only. IF YOU HAVE ANY QUERIES REGARDING THE ABOVE POINTS THEN PLEASE CONTACT NEWSON GALE WITHOUT DELAY. 1

Earth-Rite II Important The cables must enter the enclosure through the entries as shown to ensure certification is maintained. Always use correctly specified and certified cable glands or conduit fittings. Please refer to the main manual for conduit installations. You will invalidate the certification if you do not install as per the instructions 1. CABLE ENTRY FOR CLAMP CIRCUIT CABLE (FROM MONITORING PCB TERMINALS C1 AND C).. NOT APPLICABLE TO THE ERII PLUS SYSTEM.. 3. CABLE ENTRY FOR GROUND CABLE (FROM MONITORING PCB TERMINAL G1). 4. CABLE ENTRY FOR GROUND CABLE (FROM MONITORING PCB TERMINAL G). 5. CABLE ENTRIES FOR NON-INTRINSICALLY SAFE CABLES (FROM POWER SUPPLY PCB TERMINAL BLOCKS PL1, PL, PL3 AND PROTECTIVE EARTH TERMINAL). ERII 1 Junction Box 3 4 5 Grounding Clamp Site Static Earth Bar / Tape 13

14

15

United Kingdom Newson Gale Ltd Omega House Private Road 8 Colwick, Nottingham NG4 JX, UK +44 (0)115 940 7500 groundit@newson-gale.co.uk Deutschland Newson Gale GmbH Ruhrallee 185 45136 Essen Deutschland +49 (0)01 89 45 45 erdung@newson-gale.de United States IEP Technologies, LLC 417-1 South Street Marlborough, MA 0175 USA +1 73 961 7610 groundit@newson-gale.com South East Asia Newson Gale S.E.A. Pte Ltd 136 Joo Seng Road, #03-01 Singapore 368360 +65 6704 9461 ngsea@newson-gale.com NG UK ATEX P1 PLUS DC ISM 131117 R4