terminal unit accessories

Similar documents
terminal unit accessories

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Job Name Control Systems Description Date

Digital Precise Air Control - DPAC

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Verasys System Operation Overview Technical Bulletin

Ramp It Up VAV Ramps and Controller Possiblities

Selected Laboratory Energy Efficiency Measures

Your Home. Jacco & Assoc.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

York 25-Ton VAV Rooftop Unit

T7984 A,B,C Electronic Modulating Control Thermostats

MicroTech Self-Contained Air Conditioning System

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

T6984 A,D,E Electronic Floating Control Thermostats

Pioneer Gold Controller Technical Guide

Feature Summary. I. System

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Heatrix Electric Duct Heater HXOB Installation Instructions

Electric Duct Heaters. IDHB & IDHC Series

Song Deng, P.E. Assistant Director Energy Systems Laboratory Texas A&M University College Station, TX

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

Pioneer Gold Controller Technical Guide. Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal

MicroTech Rooftop/RMC

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

HVAC Controls Upgrades: Requirement Details ( )

iworx Air Side Application Wiring Guide

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Power and Energy Management Solutions

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

AIR TERMINALS & DUCT HEATERS.

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Wiring Diagrams Units Produced After April 20, 2009

Mechanical Compliance Certificate

1. Packaged Variable Air Volume (VAV) Rooftop Units (RTU) with Hot Water Reheat. 2. Geothermal Heat Pump VAV Rooftop Units with Hot Water Reheat

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

COMcheck Software Version Mechanical Compliance Certificate

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

T6984F,G Electronic Floating Control Thermostats

UNIFIED FACILITIES GUIDE SPECIFICATIONS

HVAC Controls Upgrades: Requirement Details ( )

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

HVAC Mandatory Provisions Part II, Page 1

Supply air temperature reset

DIGI-VAV APPLICATIONS

Product Data. Features/Benefits. AirManager Control. 33AM Comfort System

Continuous Commissioning SM Report. For. Wing 86, Chemistry Complex (Building # 376) Hui Chen Song Deng Homer L. Bruner, Jr., CEM.

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

CONTENTS. Installation Guide. VT7200 Series

COMcheck Software Version Review Mechanical Compliance Certificate

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

VCB-X Modular Service Tool Technical Guide. VCB-X Controller Code: SS1051 Version 2.0 Requires Service Tool Code: SS1041 Version 2.

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

DXM2 Digital Heat Pump Controller

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

features Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

COMcheck Software Version Mechanical Compliance Certificate

American University Design Standards

2009 IECC Commercial Mechanical Requirements

Dehumidifying with Dedicated Outdoor Air

Description of the functions, IQlogic

REPLACEMENT PARTS MANUAL

HVAC Design Overview of Variable Air Volume Systems

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Zoning System Design Manual

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

ASHRAE JOURNAL ON REHEAT

Submitted to. Texas A&M University at Commerce The Texas A&M University System. Submitted by. Guanghua Wei Craig Campbell David Claridge Dan Turner

Reference Guide for Microprocessor Controller

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

AHU Air Handling Unit Fundamentals. j.ilangumaran

1.0 Digital Controller

48 50 UH UA PACKAGED ROOFTOP

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

Computing Services Center

Memorial Student Center Complex (Bldg. 454)

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Design Options For HVAC Distribution System. Course Content

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Transcription:

CNTRL SEQUENCES SINGLE DUCT VAV (Variable Volume) Cooling the minimum to the maximum Models: PESV, PECV, PQCV VAV Cooling, Reheat thermostat modulates the hot water coil valve toward the closed position. n a further increase in room temperature, the room the minimum to maximum CAV (Constant Volume) Cooling The airflow remains constant regardless of A room thermostat is not used. CAV Cooling, Reheat The cold airflow remains constant regardless of As room temperature increases, the room thermostat modulates the hot water coil valve toward the closed position. CAV. CAV Flow VAV VAV Cooling, Electric Reheat thermostat de-energizes the electric heating one step at a time. n a further increase in room temperature, the room thermostat modulates the cold airflow from the minimum to the maximum CAV Cooling, Electric Reheat The cold airflow remains constant regardless of As room temperature increases, the room thermostat de-energizes the electric heating coil one step at a time. Step 3 CAV 0 1 2 3 4 5 6 7 8 910 1112131415 CNTRL SEQUENCES Control ption Code: WU VAV Cooling with Morning Warm-Up (MWU) A separate 15 to 25 psi pneumatic signal line to each terminal unit resets the controller setpoint through a signal selector relay for pressure independent hot airflow at the maximum Additional heat may be provided by a heating coil on the discharge of the unit. Models: PESV, PECV, PQCV When the warm-up signal is turned off, the unit resumes normal cooling operation. As the room temperature increases, the room the minimum to the maximum MWU 18

SINGLE DUCT Control ption Code: DM VAV Cooling, Dual Minimum Flows, with Reheat (Signal Line) When the signal line is zero psi, a decrease in room temperature modulates the cold airflow from the maximum to the minimum Control ption Code: DP VAV Cooling, Dual Minimum Flows, with Reheat (Dual Pressure Main) At the summer main pressure (usually 18 psi) a decrease in room temperature modulates the airflow from maximum down to the minimum When the signal line equals the alternate psi, a decrease in room temperature modulates the airflow from maximum to alternate minimum A further decrease in room temperature modulates the hot water valve or steps the electric coil for reheat. At the winter main pressure (usually 23 psi), a decrease in room temperature modulates the airflow from maximum down to alternate minimum A further decrease in room temperature modulates the hot water valve to open or steps the electric coil on for reheat. Alt. Total Alt. Control ption Code: FF VAV Cooling and VAV Heating, Equal Maximum Flows (Flip-Flop) A decrease in room temperature modulates the airflow from maximum to minimum setting (at room thermostat setpoint). A further decrease in room temperature modulates the airflow from minimum to maximum setting and modulates the hot water control valve to the open position. 0 1 2 3 4 5 6 7 8 9101112131415 Control ption Code: D VAV Cooling and VAV Heating, Dual Maximum Flows A decrease in room temperature modulates the airflow from maximum to minimum setting (at room thermostat setpoint). A further decrease in room temperature modulates the airflow from minimum to alternate maximum setting and modulates the hot water control valve to the open position. 0 1 2 3 4 5 6 7 8 9101112131415 CNTRL SEQUENCES 19

DUAL DUCT VAV, Mixing The hot and cold duct controllers are set independently for maximum airflow Both controls are set for zero minimum airflow. and cold controls can be set for equal maximum airflow. If heating loads are less Model: PEDV VAV with Mixing (Attenuator required) total flow sensors. The hot control is still set for zero minimum airflow. The unit minimum is set on the cold inlet control. Unequal inlets are available for the hot inlet. Models: PEDV, PMDV demanding or unequal inlets are required, the hot duct maximum can be adjusted for a lower Equal Flow Rates Unequal Flow Rates Maximum airflow can be independently adjusted for equal or unequal settings. Mixing begins when the cold airflow reaches minimum airflow. When the hot airflow is greater than the unit minimum, the cold damper is fully closed. ptional cold inlet and hot total flow sensors are available. VAV with Maximum Equal to Unit Minimum (Attenuator required) total flow sensors. The hot control is still set for zero minimum airflow. The unit minimum is set on the cold inlet control. Unequal inlets are available for the hot inlet. Maximum airflow for the hot inlet is set equal to unit minimum. Mixing begins when the cold airflow reaches minimum airflow. When the hot airflow is equal to the unit minimum, the cold damper is fully closed. ptional cold inlet and hot total flow sensors are available. 0 1 2 3 4 5 6 7 8 9101112131415 CNTRL SEQUENCES Models: PEDV, PMDV Constant Volume (Attenuator required) total flow sensors. The hot control is set for zero minimum airflow and maximum airflow is equal to total airflow. Models: PEDV, PMDC The cold control minimum and maximum are set equal to total flow. The room thermostat is connected to the hot control only. If the optional cold inlet and hot total sensors are selected, the mixing occurs between 8 and 13 psi thermostat pressure.

FAN PWERED Constant Volume Fan VAV Terminal with Water Heat The unit fan delivers a constant airflow to the space at all times. As the room temperature decreases, the primary air valve modulates the airflow from the maximum to the minimum Constant Volume Fan VAV Terminal with Electric Heat The unit fan delivers a constant airflow to the space at all times. As the room temperature decreases, the primary air valve modulates the airflow from the maximum to the minimum the room thermostat modulates the water coil valve to the open position. the electric heating coil is energized one step at a time. Total Step 3 Total Variable Volume Fan VAV Terminal with Water Heat As the room temperature decreases, the primary airflow modulates from maximum to minimum setting (at room thermostat setpoint). the room thermostat energizes the unit fan and the water coil valve modulates to the full open position. Models: PTQP, PFLP Variable Volume Fan VAV Terminal with Electric Heat As the room temperature decreases, the primary airflow modulates from the maximum to the minimum setting (at room thermostat setpoint). Models: PTQP, PFLP the room thermostat energizes the unit fan and the electric heating coil is energized one step at a time. Step 3 0 1 2 3 4 5 6 7 8 9101112131415 CNTRL SEQUENCES 21

FAN PWERED Control ption Code: AC Shutdown (NSD) PE Day operation, main air N. See the control sequence outlined on page 21. Control ption Code: AE Setback (NSB) PEs Day operation, main air N. See the control sequence outlined on page 21. Night operation, main air FF, primary air fan must be shut off. The unit fan remains off until the main air is restored. Units with electric heat must use reverse acting thermostats to prevent heat operation when fan is off. Night operation, main air FF, air fan must be shut off. The unit fan remains off until the night setback thermostat calls for heat. The unit fan energizes followed by the water or electric heat. Units with electric heat must use reverse acting thermostats to prevent heat operation when fan is off. Night peration Central System ff Fan Terminal Unit Fan ff Central System ff ptional Heating Coil NSB Setpoint Control ption Code: AD Shutdown (NSD) Switch Day operation, primary air handler N. See control sequence on page 21. Night operation, primary air to the unit is shut off. The unit fan remains off until the primary air is restored. Night peration Central System ff Fan Shut Down Models: PTFS, PTQP, PFLP 0 1 2 3 4 5 6 7 8 9101112131415 CNTRL SEQUENCES Control ption Code: AF Setback (NSB) Switch Day operation, primary air handler N. See the control sequence on page 21. Models: PTFS, PTQP, PFLP Night operation, primary air FF. The unit fan remains off until the night setback thermostat calls for heat. The unit fan energizes followed by the water or electric heat. Central System ff ptional Heating Coil NSB Setpoint 0 1 2 3 4 5 6 7 8 9101112131415 22