Installation plan Heat pump dryer PT 8203 SL WP

Similar documents
Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 04

Installation plan Commercial Washing Machine PW 413 PW 418

Operating instructions Commercial flatwork ironer PM 1210 PM 1214 PM 1217

Operating and installation instructions Salamander

Installation plan. Washer disinfector. en AU, NZ PG 8583 CD. M. Nr

Operating and installation instructions Cooker hood

Operating and installation instructions Deep fat fryer

Operating and installation instructions Cooker hood

Operating and installation instructions Induction wok

Operating and installation instructions Gas hobs

Installation Plan Washing Machine PW 811 PW 814 PW 818

Operating and installation instructions Built-in vacuum sealing drawer

Operating and installation instructions Gas hobs

Operating and installation instructions Cooker hood

Operating and installation instructions Food warming drawer

Operating and installation instructions Cooker hood

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Operating and installation instructions Food warming drawer

Tumble dryer PT 5136 PT en - GB. Installation plan

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Operating and installation instructions Rangehood

Operating and installation instructions Rangehood

Commissioning the machine, Programme chart, Settings PW 6065 Vario

Installation instructions Gas cooktops

Installation instructions Gas cooktops

Installation plan PG 8581 PG 8582 PG en - US

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

Warranty. Guarantee. M-Nr

Installation and Operating Manual Drying Cabinet

Operating and installation instructions

Installation plan: PG Mat. no Version 00 US

Professional dishwashers for outstanding performance and spotless results

Intercom Systems Video Intercoms

DIGIHEAT IN LINE HEATERS

en-gb Operating instructions Rotary ironer PM 1621 PM 1625 PM 1630 PM 1635 PM 1825 PM 1830 PM 1835

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Product overview Laundry machines. Washing, Drying, Ironing Thorough, gentle and efficient laundry care

Operating instructions Rotary iron HM

Installation instructions. Designer series wall canopy. and User guide NZ AU GB IE. HC90DXB1, HC90DMB1 models

The perfect ironing solution in one complete system

Installation Specifications Laundry Care System

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

SHORT WAVE INFRARED PANEL DRYER

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

INSTALLATION INSTRUCTIONS USER GUIDE

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installationsplan / Installation plan PW 6161 EL

Moisture inside the drum is due to final testing.

INSTALLATION INSTRUCTIONS USER GUIDE

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Operating and installation instructions Rangehood

INSTALLATION INSTRUCTIONS USER GUIDE

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

Classic Heater Pool Controller

Installation & Operators Manual. The Classeq Pass Through Range

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Drying Cabinet Installation and Operating Manual

Moisture inside the drum is due to final testing.

LITTLE GIANTS Miele's new PW 5064 mop washer

Operating and Installation Instructions Speed Oven

Installation and Wiring Instructions

Hold-open magnets DORMA

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

AV1210 AV1260

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

OPERATOR S MANUAL NORBAR JOINT SIMULATION RUNDOWN FIXTURES. Part Number Issue 2 Original Instructions (English)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Pure Glass. saturn.clipsal.com

Operating Instructions

Operating and installation instructions Rangehood

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

Original instructions AR

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Installation instructions. and User guide. Freestanding canopy NZ AU. HF60CSW2 & HF60CSX2 models

Rotary ironers for the perfect laundry finish

ER MANUAL FOR YOUR BAUMATIC

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Dräger Polytron 5720 IR Detection of carbon dioxide

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

Installation & Operating Instructions

Installation instructions. Built-in oven NZ AU. BI453 and BI603 models

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314

Whole Room Dryer WRD, WRD/110

INSTALLATION GUIDE NZ AU D

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

INSTALLATION INSTRUCTIONS

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Transcription:

Installation plan Heat pump dryer PT 8203 SL WP To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first time. en - GB, IE M.-Nr. 10 534 370

2 PT 8203 SL WP

Contents Installation and planning notes... 4 Installation requirements... 4 General operating conditions... 4 Installation... 4 Levelling the machine... 5 Securing the dryer against slippage... 6 Guide to the machine... 6 Electrical connection... 7 Air intake vent... 8 Air outlet vent... 8 Condensate drainage... 8 Accessories... 9 Communication module XKM for RS 232 interface... 9 Technical drawings - dimensions in mm... 10 Dimensions... 10 Installation... 11 Set up... 12 Technical data... 13 Electrical data... 13 Voltage variant 3N AC 400 V, 50 Hz... 13 Condensate drainage... 13 Transport data... 13 Installation data... 13 3

Installation and planning notes Installation requirements The dryer must only be set up by a Miele authorised and trained service technician or an authorised dealer. This dryer must be installed in accordance with all relevant regulations and standards. Local energy supplier regulations must also be observed. This dryer must only be operated in a room that has sufficient ventilation and which is frost-free. General operating conditions This dryer is intended only for use in a commercial environment and must only be operated indoors. Permissible ambient temperature: 2 C to 43 C The electrical components of this dryer comply with safety standards IEC/DIN EN 60335-1 and DIN EN 50570. Installation This dryer must only be transported with the transport safety device fitted. Transport the dryer to its installation site using a suitable pallet truck and then remove the transport safety device. Keep this device in a safe place for refitting should the dryer need to be moved in the future (e.g when moving to a new site). When transporting the dryer be aware of its total height. Be careful when transporting it on a pallet truck that it does not tip up. The dryer must be set up on a level and firm surface, with a minimum load bearing capacity of 2220 N. The floor load created by the dryer is concentrated and transferred to the installation footprint via the machine feet. 4 PT 8203 SL WP

Installation and planning notes To ensure easy access in the event of future servicing, please maintain a gap of at least 500 mm behind the dryer. After setting up the dryer please let it stand for approx. 30 minutes before using it for the first time. If the heat-pump unit was tilted by an angle of 30 before the dryer was set up, or if it was subjected to excessive movement, please let the dryer stand for 24 hours before using it. Otherwise the heat pump can suffer damage. Levelling the machine To ensure the dryer functions correctly and energy efficiently, it must stand securely and evenly on the floor with all four feet. Any unevenness in the floor can be compensated for by adjusting the feet. Loosen the counter nuts on the feet using a spanner. With the assistance of a spirit level align the dryer horizontally and vertically by adjusting the height of the feet. After aligning the dryer tighten the counter nuts by turning them in a clockwise direction with a spanner. This will prevent the feet from adjusting themselves. PT 8203 SL WP 5

Installation and planning notes Securing the dryer against slippage The dryer can be secured to the floor by fitting the clamps supplied over the feet. Fittings supplied are for installation on a concrete floor. For other types of flooring please purchase suitable fitting materials separately. Guide to the machine a Control panel with controls b Door c Fluff filter compartment cover d Air intake vent e Machine feet Qty 4, adjustable f Electrical connection with cable gland g Communication module slot for XKM RS 232 Optional accessory h Condensate drainage i Air outlet vent j Data plate 6 PT 8203 SL WP

Installation and planning notes Electrical connection The electrical connection must be carried out by a qualified electrician who must ensure that all electrical work is carried out in accordance with applicable electrical regulations and standards (BS 7671 in the UK). This dryer must be connected to an electrical mains supply that complies with local and national regulations. Please also observe your insurance and energy supplier's regulations as well as any health and safety at work regulations. The required voltage, power consumption and specifications for external fusing are quoted on the data plate on the dryer. Ensure that the supply voltage complies with the voltage quoted on the data plate before connecting the dryer to the mains. Connection to a supply voltage other than the one quoted on the data plate can lead to functional faults and damage the dryer. If more than one voltage is quoted on the data plate, the dryer can be converted for connection to the voltages stated. Conversion to a different voltage must only be carried out by a Miele Service engineer or by an authorised Service Dealer. The wiring instructions given on the wiring diagram must be followed. This dryer can either be hard-wired or connected via a plug and socket that complies with IEC 60309-1. For hard-wired machines connection should be made via a suitable mains switch with all-pole isolation which, when in the off position, ensures a 3 mm gap between all open contacts. These include circuit breakers, fuses and relays (IEC/EN 60947). If the mains supply cannot be permanently disconnected, the isolator switch (including plug and socket) must be safeguarded against being switched on either unintentionally or without authorisation. Tip: We recommend connection to the power supply via a suitable IP 44 plug and socket which must be easily accessible for servicing and maintenance work after the machine has been installed. An electrical safety test must be carried out after installation and after any service work. If it is necessary to install a residual current device (RCD) in accordance with the local regulations, a residual current device type A can be used. Equipotential bonding with a good contact connection should be carried out in accordance with local and national installation regulations. Equipotential bonding with a leakage current of >10 ma should be carried out. Accessories required for equipotential bonding (washers and nuts) are not supplied with the machine. PT 8203 SL WP 7

Installation and planning notes Air intake vent Air intake for the condenser is via an air intake vent at the front of the dryer. Air is taken from the room in which the dryer is installed. A fluff filter is located in the air intake vent in the dryer. This must be regularly cleaned by hand. The air intake vent must be kept clear. It must not be covered. Air outlet vent Because the heat-pump dryer operates with a closed air circuit, separate exhaust ducting is not required. The warm air expelled from the machine as a result of cooling down the heat-exchanger warms the room air. It is essential to ensure the room has adequate ventilation, e.g. by providing ventilation openings that cannot be closed whilst the machine is in use. Insufficient ventilation in the room increases the time required for drying, which in turn will increase the amount of energy required for the drying process. The ventilation openings must, on no account, be closed or blocked by objects. Condensate drainage The heat-pump in this dryer operates on the principle of condensation. A separate floor drain must be provided in the installation room for condensate from the drying process. The condensate drainage point is located at the back of the heatpump dryer. The condensate must be drained via a downwards pointing DN 30 pipe to the floor drain. Ensure that condensate cannot backflow into the dryer. A non-return valve, available as an optional accessory, can be fitted if necessary. Any condensate that gets back into the machine can cause damage. 8 PT 8203 SL WP

Accessories Installation and planning notes Accessory or spare parts may only be connected or built-in to this machine if they are expressly approved for such use by Miele. If non-miele parts are used, guarantee, performance and product liability claims may be invalidated. Communication module XKM for RS 232 interface The serial interface RS-232 can be retrofitted to the dryer via an XKM RS 232 (optional accessory available from Miele). This communication module must only be used with Miele Professional machines that are fitted with an appropriate slot for the module. The data interface provided via communication module XKM RS232 complies with SELV (Safety Extra Low Voltage) in accordance with EN 60950. Appliances connected to this interface must also be SELV compliant. Communication module XKM RS 232 is supplied with a connection cable and a D-sub-connector. PT 8203 SL WP 9

Technical drawings - dimensions in mm Dimensions 1074 10 PT 8203 SL WP

Technical drawings - dimensions in mm Installation 618 90 1700 254 200 >100 50 500 200 1700 a Electrical connection b Condensate drainage PT 8203 SL WP 11

Technical drawings - dimensions in mm Set up 3 3 3 c Anchoring point (optional) 12 PT 8203 SL WP

Technical data Electrical data Voltage variant 3N AC 400 V, 50 Hz Voltage 3N AC 400 V Frequency 50 Hz Fuse rating 3 x 16 A Total connected load 2,6 kw Current draw 3 x 8,5 A Connection cable, min. cross-section 5 x 2,5 mm² Cable gland M25 x 1,5 Condensate drainage External diameter Length (from the rear panel) 32 mm 50 mm Transport data Packaging width Packaging height Packaging depth Volume Weight (gross) 800 mm 1810 mm 1180 mm 1651,8 l 213 kg Installation data Overall machine width Overall machine height Overall machine depth Casing width (without add-on components) Casing height (without add-on components) Casing depth (without add-on components) Machine weight (net) Max. floor load in operation Minimum width of loading aperture (internal width) Recommended distance between front of machine and the wall Average heat dissipation rate to installation site Emission sound pressure level in accordance with EN ISO 11204 Noise power level in accordance with EN ISO 9614-2 711 mm 1800 mm 1075 mm 708 mm 1800 mm 999 mm 202 kg 2220 N 725 mm 1500 mm 650 W 57 db (A) 71 db (A) PT 8203 SL WP 13

United Kingdom Miele Co. Ltd. Fairacres, Marcham Road Abingdon, Oxon, OX14 1TW Professional Sales, Tel: 0845 365 6608 E-mail: professional@miele.co.uk Internet: www.miele-professional.co.uk Australia Miele Australia Pty. Ltd. ACN 005 635 398 ABN 96 005 635 398 1 Gilbert Park Drive, Knoxfield, VIC 3180 Tel: 1300 731 411 Internet: www.miele-professional.com.au E-mail: info@miele-professional.com.au China Miele (Shanghai) Trading Ltd. 1-3 Floor, No. 82 Shi Men Yi Road Jing' an District, 200040 Shanghai, PRC Tel: +86 21 6157 3500, Fax: +86 21 6157 3511 E-mail: info@miele.cn, Internet: www.miele.cn Miele (Hong Kong) Limited 41/F - 4101, Manhattan Place 23 Wang Tai Road Kowloon Bay, Hong Kong Tel: (852) 2610 1025, Fax: (852) 3579 1404 Email: customerservices@miele.com.hk Website: www.miele.hk India Miele India Pvt. Ltd. Ground Floor, Copia Corporate Suites Plot No. 9, Jasola New Delhi - 110025 Tel: 011-46 900 000, Fax: 011-46 900 001 E-mail: customercare@miele.in, Internet: www.miele.in Ireland Miele Ireland Ltd. 2024 Bianconi Avenue Citywest Business Campus, Dublin 24 Tel: (01) 461 07 10, Fax: (01) 461 07 97 E-Mail: info@miele.ie, Internet: www.miele.ie Manufacturer: Miele & Cie. KG Carl-Miele-Straße 29, 33332 Gütersloh, Germany Malaysia Miele Sdn Bhd Suite 12-2, Level 12 Menara Sapura Kencana Petroleum Solaris Dutamas No. 1, Jalan Dutamas 1 50480 Kuala Lumpur, Malaysia Phone: +603-6209-0288 Fax: +603-6205-3768 New Zealand Miele New Zealand Limited IRD 98 463 631 Level 2, 10 College Hill Freemans Bay, Auckland 1011, NZ Tel: 0800 464 353 Internet: www.miele-professional.com.au E-mail: info@miele-professional.com.au Singapore Miele Pte. Ltd. 163 Penang Road # 04-03 Winsland House II Singapore 238463 Tel: +65 6735 1191, Fax: +65 6735 1161 E-Mail: info@miele.com.sg Internet: www.miele.sg South Africa Miele (Pty) Ltd 63 Peter Place, Bryanston 2194 P.O. Box 69434, Bryanston 2021 Tel: (011) 875 9000, Fax: (011) 875 9035 E-mail: info@miele.co.za Internet: www.miele.co.za United Arab Emirates Miele Appliances Ltd. Gold & Diamond Park Office No. 217-6, Sheikh Zayed Road P.O. Box 11 47 82 - Dubai Tel: +971 4 3044 999, Fax: +971 4 3418 852 800-MIELE (64353) E-Mail: info@miele.ae, Internet: www.miele.ae Alteration rights reserved / Publication date: 2016 M.-Nr. 10 534 370 / 00 PT 8203 SL WP