MICROPOINT to MICROPOINT II UPGRADE

Similar documents
PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

INTREPID Perimeter Intrusion Detection System

Product Specifications

INTREPID Buried Cable Perimeter Intrusion Detection System

INTREPID Buried Cable Perimeter Intrusion Detection System

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

INTEGRATED PERIMETER SECURITY SOLUTIONS

INTEGRATED PERIMETER SECURITY SOLUTIONS FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS ALARM MONITORING AND CONTROL SYSTEMS MICROWAVE SENSORS

Product Specification

Product Specifications

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Architectural and Engineering Specification for a Security Management System. StarNet 2

SUPREMATouch. Modular Fire & Gas Detection System

Four-Door Access Controller User s Manual

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Fiber Optic Cable Fence Disturbance Sensor

Scanlight Next generation dimmable addressable lighting control

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

Microphonic Cable Fence Disturbance Sensor (multiplex version)

APPLICATION DATA SHEET

Four-Door Access Controller User s Manual

Intelligent Single Loop Fire Alarm Control Panel

Introducing the innovative ipids Indoor Outdoor Detection System MANUFACTURING SECURITY SOLUTIONS

Design. Innovations in Integrated Control Systems

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Advanced FireAlarm Panel 1-4Loop

The EN54 Part 2 & 4 Fire System

21-light Remote Annunciator. Owner s Manual

SmartAlarm Annunciator

ZXSe Range Data Sheet

Security designed for your lifestyle

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Metasys Integrator Cleaver-Brooks Application

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

The IPPS was developed on IBM-PC platform under QNX real time operating system (RTOS) and uses QNX-Windows GUI.

WG Buried Cable Perimeter Detection System

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

Control System Structure

Frequently asked questions: Intelligent Transmitter Series

SiteSentinel itouch Console

MHC Series Sensors

20 Light Remote Annunciator

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Gallagher System Integrations

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

IS IP Video Door Phone. FEATURES

Buried ported coaxial cable outdoor intrusion detection system

CCU Family of Modules

Dew point set DS 400

Section PERIMETER SECURITY SYSTEMS

SIMATRIX NEO Modular Video Matrix

Am I safe working in this building?

DRAFT 20 October 2014

Intelligent Addressable Fire Alarm System

A Smart & Integrated Security solution

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Reliably Advanced Extinguishing Control

WG Buried Fibre Cable Long Perimeter Detection System

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

OpenDevice United Technologies Corporation. Lenel is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.

TOTAL PERIMETER SOLUTION

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

SC-F3G User Manual 1.0

JVA Electric Security Fence System. perimeter intruder detection system

ACTIVE INFRARED BARRIER

APPLICATION DATA SHEET

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Different types of Fire Alarm System

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

RLS-3060SH REDSCAN ULTIMATE

Remote / Network Control for Rack Cabinet Access - DL Series

SUPREMATouch Modular Fire & Gas Detection System

ID2000. intelligent fire alarm panel

Danfoss gas detection unit Type GD Heavy Duty

Model A1700 Series Annunciator

EC-BOS-602/616 AX Security

Air & Water Heat Pump R832

Siemens Building Technologies Landis & Staefa Division. for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55

Model A2100 Series Annunciator

For Complete Fire and Gas Solutions

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

LSM MANUAL PRINCIPLES OF LSM

Reliably Advanced Extinguishing Control

Datasheet Face Recognition [Genetec VMS]

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Altanium Temperature Controllers

FTS500 Series. Handheld OTDR Test Set.

Transcription:

MICROPOINT to MICROPOINT II UPGRADE Why is INTREPID II an intelligent upgrade choice for my customer?. II is highly scalable and can be easily configured to address a range of security requirements, site characteristics and system sizes. 2. The common communications protocol of our INTREPID Series II detection suite enables single-platform networking of II with other Series II systems (MicroTrack II, MicroWave 330), enabling integration flexibility when layering of technologies is required. 3. Common DC Power (0.5-60 VDC) is specified for all Series II devices, incl. II. 4. For simplified sensor configuration, user-friendly Universal Installation Service Tool II (UIST II) software manages set-up of all INTREPID Series II systems, including II. 5. Flexible controller options address all budgets and project needs, from local or remote relay control to centralized GUI-based solutions for TCP/IP management of large or multi-site applications. 6. Two developer-friendly SDK options simplify integration of II (and all INTREPID Series II devices) to third party IM, VMS or custom control applications. 7. Industry-leading 5-year Warranty protection on all II equipment. What elements remain the same between and II systems?. The sensor cable is identical for both systems. As long as cable from an original system has been well-maintained, it may be reused with II hardware. 2. Module locations are identical for both systems. Upgrade is as simple as a change of hardware. 3. Detection zones are assigned in system software for flexibility and cost savings. 4. Zone integration with CCTV presets offers precise visual assessment of alarms. 5. Sensitivity Leveling software-based calibration achieves uniform detection sensitivity. 6. Point Impact Discrimination provides reliable detection and nuisance alarm rejection. 7. Both systems offer precise location of alarms to within 3 m / 0 ft. 8. Integration with Southwest Microwave s legacy sensors and third party devices. How long can I continue to purchase original INTREPID equipment? Original systems have reached End of Life. Though we plan to support product repairs through 202, limited spare and replacement parts are available and many system components are already out of stock. CORPORATE HEADQUARTERS: SOUTHWEST MICROWAVE, INC. 9055 S. MCKEMY ST. TEMPE, ARIZONA 85284 USA TEL + 0 783 020 INFOSSD@SOUTHWESTMICROWAVE.COM EUROPEAN OFFICES: SOUTHWEST MICROWAVE LTD. #3, DEER PARK BUSINESS CTR WOOLLAS HILL, ECKINGTON, WORCESTERSHIRE WR0 3DN UK TEL +44 386 755 02/8

FENCE DETECTION SYSTEMS GENERAL FEATURES SERIES I SERIES II II Warranty Terms Yr (std), Yr + 2 Yr Ext. Warranty (on registration) 3 Yr (std), 3 Yr + 2 Yr Ext. Warranty (on registration) Communications Protocol Unique to Universal Alarm Location / Resolution 3 m / 0 ft 3 m / 0 ft Sensitivity Leveling calibration feature achieves uniform detection sensitivity across the protected fence line Point Impact Discrimination detects legitimate intrusion attempts but rejects environmental nuisance alarms Detection Length Per 209 m 220 m Network Architecture Communication Ports Remote Sensor Administration Direct Connection: RS-232 or RS-422 Network Interface Module RS-422 Adapter Card RS-232 Adapter Card Star, Loop, Fault Tolerant Loop 2 built-in RS-422 (Comm) RS-232 (Set-up) With CM II-N, GCM II-HD Controllers Power Conversion With Power Converter Card Built-in Installation / Service Software Voltage range Alarm Response Time Software-based integration to third-party security or video management systems (IM / VMS) Integration with CCTV for precise assessment of alarms System Size Parameters (Max Number of Devices on a Single Communications Bus) Dedicated service tool for each sensor Varies by device type Variable (< sec per system) Dedicated SDK: TPI - Cable SDK - MicroTrack, M, TPI 8 PMs / system M: 64 systems / PC TPI: Universal Installation / Service Tool (UIST II) Universal (0.5-60VDC) Predictable 25 ms / device (up to 8 devices) Common SDK: IPP II: HLI RPM II: HLI +, M, SDK, ASCII (GCM II-HD) RCM II: 8 devices CM II-N: 6 devices (4 remote) GCM II-HD: 32 devices M: 240 devices IPP II SDK: RPM II SDK: 6 CORPORATE HEADQUARTERS: SOUTHWEST MICROWAVE, INC. 9055 S. MCKEMY ST. TEMPE, ARIZONA 85284 USA TEL + 0 783 020 INFOSSD@SOUTHWESTMICROWAVE.COM 2 EUROPEAN OFFICES: SOUTHWEST MICROWAVE LTD. #3, DEER PARK BUSINESS CTR WOOLLAS HILL, ECKINGTON, WORCESTERSHIRE WR0 3DN UK TEL +44 386 755 02/8

SYSTEM CONTROLLERS Relay Module This control module offers smaller facilities with cost-effective local control of INTREPID, contact-closure auxiliary security devices and CCTV equipment or other security inputs. 8 on board relays. Basic Map Monitor / Advanced Map Monitor / Multi-Map Monitor Windows-based monitoring software for system. On-screen GUI with display of alarms to within 3 m. Basic alarm reports. Five language capability. Alarm Tagging. Single or multi-site use. Single or multiple PC use. 70 zones maximum. Requires user PC. Consult data sheet for minimum technical requirements. Relay Control Module II Offers smaller facilities with cost-effective local control of INTREPID Series II devices, contact-closure auxiliary security devices and CCTV equipment or other security inputs. Simple zone record setup via terminal emulator. 8 on board relays. Connects up to 8 devices. Control Module II-N Relay-based system control module designed to offer facilities with local or remote control of INTREPID Series II devices, contact closure auxiliary security devices and CCTV equipment or other inputs. Features zone assignment and management via Controller Setup Tool II (CST II) terminal emulator. Supports multiple languages and auto-discovery of all connected devices. Connects up to 6 local devices (or 4 remote). 256 zone records. Graphic Control Module II-HD Dedicated, Linux-based system controller, offering local GUI-based alarm monitoring and control of INTREPID Series II devices and contact-closure auxiliary security devices, CCTV equipment or other security inputs. Supports multiple languages, auto-discovery of all connected devices. 256 user accounts, connects up to 32 devices, 024 zone records. ASCII output for serial CCTV interface. Hardened or standard versions available. Perimeter Security Manager Advanced, Windows-based security monitoring and control system for large or multi-site facilities. Local or remote GUI-based alarm monitoring and control of INTREPID devices and contact-closure auxiliary security devices. High level interface to CCTV, incorporating live video and maps on a single display. Installable on user PC. Requires user PC. Consult data sheet for minimum technical requirements. Third Party Interface (TPI) Windows-based DLL available free of charge to developers for high-level integration of system into custom control applications. Software Development Kits (SDK) Available free of charge to developers for high-level integration of MicroPOint II and other INTREPID Series II devices into custom control applications. Platform-independent. II Two developerfriendly SDK options (IPP II / RPM II) CORPORATE HEADQUARTERS: SOUTHWEST MICROWAVE, INC. 9055 S. MCKEMY ST. TEMPE, ARIZONA 85284 USA TEL + 0 783 020 INFOSSD@SOUTHWESTMICROWAVE.COM 3 EUROPEAN OFFICES: SOUTHWEST MICROWAVE LTD. #3, DEER PARK BUSINESS CTR WOOLLAS HILL, ECKINGTON, WORCESTERSHIRE WR0 3DN UK TEL +44 386 755 02/8

Southwest Microwave, Inc. Telephone + (0) 783-020 to II Upgrade Alarm Annunciation Matrix SCALE NTS DRAWN TG DATE 2/7/207 Alarm Annunciation Chart METHOD Controller INTREPID Controller INTREPID II Outputs Zones Outputs Zones RELAY 70* RCM II CM II-N 32 256 GUI Basic Monitor Multi-Map Monitor Advanced Monitor M CCTV Driver 70* GCM II-HD M ASCII for CCTV CCTV Driver 024 THIRD PARTY TPI 70* RPM II SDK ** IPP II SDK 28** * 70 Zones (50 Display Segments, 20 Auxiliary Sensors) ** RPM II provides internal 28 Zone Records for backup alarm annunciation via local form-c dry relay outputs.

Telephone + (0) 783-020 Southwest Microwave, Inc. 4 3 to II Upgrade SCALE NTS Alarm Annunciation Via Form-C Dry Relay Contacts Conceptual System Design DRAWN TG DATE PM II- LU II- 3 4 PM- LU- LU-4 LU-2 PM II-2 //207 ROM II CM II-N LU II-3 LU II-2 PM-2 PM II-4 PM-4 TU II &2 PM II-3 LU-3 PM-3 VDC PM- NIM 2VDC RS5-4 -3-2 - form-c outputs for alarm annunciation. 3 form-c outputs for alarm annunciation. Existing 2-wire RS5 communication replaced with 4-wire ROM II available in 8 & 6 outputs. ROM II6 CM II-N PM II- VDC 2VDC * = Zone break locations from the existing system will be replicated on the MicroNet II system. 2VDC Power & Alarm/ Built-In Remote System/ Sensor Diagnostics & Maintenance TCP/IP II System Communication & Power Wiring Typical Block Diagram 2VDC Power & Alarm/ 3 System Communication & Power Wiring Typical Block Diagram Existing 4-Processor System - Typical Upgraded 4-Processor II System - Typical

Telephone + (0) 783-020 Southwest Microwave, Inc. 4 3 to II Upgrade SCALE NTS Alarm Annunciation Via Local Graphical User Interface Conceptual System Design DRAWN TG DATE PM II- LU II- 3 4 PM- LU- Map Monitor LU-4 LU-2 PM II-2 GCM II-HD ROM II LU II-3 LU II-2 PM-2 PM II-4 PM-4 TU II &2 PM II-3 LU-3 PM-3 VDC 422A PM- NIM -2 - RS5 Data Converter 2VDC system triggering. 3 //207 PM II- VDC system triggering. 3 Reuse existing 4-wire communication line. ROM II6 ROM II-8 2VDC * = Zone break locations from the existing system will be replicated on the MicroNet II system. GCM II-HD 2VDC Power & Alarm/ Built-In Remote System/ Sensor Diagnostics & Maintenance TCP/IP II System Communication & Power Wiring Typical Block Diagram 2VDC Power & Alarm/ Map Monitor GUI RS232 System Communication & Power Wiring Typical Block Diagram Existing 4-Processor System - Typical Upgraded 4-Processor II System - Typical

Telephone + (0) 783-020 Southwest Microwave, Inc. 4 3 to II Upgrade SCALE NTS Alarm Annunciation Via Third Party High Level Interface Conceptual System Design DRAWN TG DATE PM II- LU II- 3 4 PM- LU- IM/VMS LU-4 LU-2 PM II-2 //207 ROM II RPM II LU II-3 LU II-2 PM-2 PM II-4 PM-4 TU II &2 PM II-3 LU-3 PM-3 VDC 422A PM- NIM -2 - RS5 Data Converter 2VDC system triggering. 3 Third Party IM/VMS system/failsafe alarm triggering. Reuse existing 4-wire communication line. ROM II available in 8 & 6 outputs. ROM II6 RPM II PM II- VDC 2VDC * = Zone break locations from the existing system will be replicated on the MicroNet II system. 2VDC Power & Alarm/ Built-In Remote System/Sensor Diagnostics & Maintenance 3 TCP/IP II System Communication & Power Wiring Typical Block Diagram 2VDC Power & Alarm/ Third Party IM/VMS RS232 System Communication & Power Wiring Typical Block Diagram Existing 4-Processor System - Typical Upgraded 4-Processor II System - Typical