INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

Similar documents
I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

CP CP

T7984 A,B,C Electronic Modulating Control Thermostats

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

FAN POWERED VAV TERMINALS

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

T6984 A,D,E Electronic Floating Control Thermostats

LZP-2 ZONE CONTROL PANEL

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Two-Position Electric Duplex Room Thermostats

TK-1801, TK-1811 TK-1801, TKR-1811

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

SINGLE DUCT TERMINAL UNITS

FAN POWERED VAV TERMINALS

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

T-32-TS Touchscreen Thermostat. Installation Manual

Control Sequence Number

TK-1001, 1101, 1201, 1301, 1601

Verasys System Operation Overview Technical Bulletin

SmartZone TM System Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual

terminal unit accessories

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

FLT93 Installation, Operation and Troubleshooting Guide

Schneider Electric Erie T155 Series

Electric Coils. Blower Coils. Product Information

Construction Electrical

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Product Manual SZ1022/SZ1031/SZ1035/

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Application Data. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan-Powered Terminal Units for Variable Air Volume (VAV) Systems

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

T500 Series Non-Programmable Thermostats

BAC-4000 Series AppStat

T6984F,G Electronic Floating Control Thermostats

Cambridge Engineering, Inc. 24 S-Series Technical Manual

Digital Precise Air Control - DPAC

KMC Conquest Controller

! WARNING. Before using product, read and understand instructions.

Product Manual SZ1009

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Predator Controller Hardware Family

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Table of Contents. Protective Relays

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

TP970 Series CONVERTASTAT Kits

Public Safety DAS Annunciator Panel

15900 HVAC INSTRUMENTATION AND CONTROLS

Accuracy by Design Products for the HVAC Professional

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

CONTENTS. Installation Guide. VT7200 Series

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

I/O ZONE 560/583 USERS GUIDE

Application Data Part Numbers: 33ZCVVTZC-01, 33ZCBC-01, 33ZCVAVTRM, 33ZCFANTRM

B-40/B-41 Modulating Temperature Controller

Power and Energy Management Solutions

Indirect gas-fired air heater

ASHRAE JOURNAL ON REHEAT

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

Chilled Water DOAS Fan Powered Terminal Units

KMC Conquest Controller

Electric Duct Heaters. IDHB & IDHC Series

Installation and Maintenance Manual IM 1102

Installation Instructions

Digital Programmable

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

EC Series Wall Unit Humidifier

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

CAUTION. No-Load Performance, Controls in Normal Position

Installation Guide.

Model 1750A/ 1770A Dehumidifier Installation Instructions

Job Name Control Systems Description Date

Commercial Touchscreen Thermostat

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Field Start-Up Sheet Direct Fired Gas Equipment

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

1.0 Digital Controller

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Heatrix Electric Duct Heater HXOB Installation Instructions

AdaptAire. Digital Control System. User Manual

Sitron s CF Line of Flow Switch Monitors

VCM-X Controller Technical Guide

Product Data. Features/Benefits. AirManager Control. 33AM Comfort System

ETAF Series VDC Fan output LCD Fan Coil Thermostat

Safety and Installation Instructions Model 1700

Product Manual SZ1145

ELECTRONIC HUMIDISTAT: H270

! WARNING. Before using product, read and understand instructions.

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

Transcription:

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS CTE-51 Series Thermostats: The CTE-51 series thermostats are designed to be used with the CSP-52 controller actuator. CTE-51 s are provided with limited and unlimited outputs. The limited output(s) is (are) used to provided minimum and maximum limits to a CSP-52. The unlimited output(s) is (are) used to operate fan and heat sequences. Models are available for cooling, cooling with reheat, cooling / heating changeover and day/night or set-back applications. Temperature averaging and/or overrides may be accomplished. Consult Nailor control submittal for applicable thermostat model. Models: CTE-511 Single setpoint; Direct Acting Supply Voltage: 16 Vdc (14-2 Vdc) CTE-513 Dual setpoint; Direct & Reverse Acting Output Range: to 1Vdc CTE-514 Dual setpoint; Direct & Reverse Acting Connections: Wire clamp type: 14-22 AWG CTE-515 Dual setpoint; both Direct Acting Temperature Range: 55 O F - 85 O F (13 O C - 29 O C) Thermostat Action: Proportional Band: CTE-511 Direct Acting (DA) T1/T3 CTE-511/3/5 2 O F, (1.1 O C) w/limits output (T1/T2) CTE-513 Direct Acting (DA) T1/T3, Reverse Acting (RA) T2/T4 4 O F, (2.2 O C) w/o limits output (T3/T4) CTE-514 Direct Acting (DA) T1/T3, Reverse Acting (RA) T2 CTE-514 2 O F, (1.1 O C) w/limits output (T1) CTE-515 Direct Acting (DA) T1/T2/T3/T4 2 O F, (1.1 O C) w/limits output (T2/T3) Base Material: Black ABS, UL Flame Class 94HB Size 2 9/16" (65 mm) x 3 7/16" (87 mm) Table 1. Thermostat Specifications. Installation: Thermostats must be mounted horizontally,(or vertically by using an optional vertical scale plate), utilizing the HMO-53/531 backplates for mounting to a standard 2" x 4" electrical box, or the optional HMO-523 drywall bracket for mounting to hollow walls. Thermostats should be mounted on a wall in an area not affected by sunlight or drafts, to sense the average room temperature. Electrical box mounting: Install the HMO-53/531 backplate to the electrical box using the two 6-32 screws, supplied with backplate do not tighten. The backplate is provided with one slotted mounting hole for leveling. Level the backplate and tighten the two mounting screws. Pull thermostat wires through backplate and decorative trim plate. Connect thermostat wires to the thermostat according to the wiring diagram supplied with the unit. Position the trim between the back plate and the thermostat, secure the assembly with the two 6-32 x 2" self tapping screws supplied. Hollow wall mounting: Loosely mount the HMO-523 bracket to the thermostat using the two 6-32 x 2" screws. Pull all thermostat wiring through the opening on the bracket. Connect thermostat wires to the thermostat according to the wiring diagram supplied with the unit. Center and align the thermostat while tightening the mounting screws. Thermostat 511 513 514 Terminals Description Terminals 515 V1 X X X Velocity input for readout, connect to out on CSP-52 T3 X X X Upper setpoint output w/o limits ( -1 Vdc) R1 X X X T1 override, connect to "-" if unused. Voltage applied subtracts from T1 T1 X X X Upper setpoint output w/limits. Adjustable at pot.on front of thermostat + X X X 16 Vdc power supply input 12V X X X 12 Vdc power output A X X X Temperature averaging input - X X X Ground reference T2 X X Lower setpoint, output w/limits. * Adjustable at pot. on front of thermostat R2 X X T2 override connect to "-" if unused ** T4 X Lower setpoint output w/o limits ( -1 Vdc) V2 X Velocity input for readout * Except 514; T2 lower setpoint output is w/o limits. ** R2 is auxiliary limit trigger on model 514. Voltage above 1 Vdc @ R2 indexes T1 to the auxiliary flow limit. Install jumper R2-T2 for automatic indexing of aux. flow setting. Table 2. Thermostat Wiring Terminals and Description. Page 1 of 1

BACK VIEW 63/64" (25) 1 31/32" (5) SCALE PLATE ( F OR C) MAX/AUX METERS HEATING V MIN KMC Controls MIN 5 7 9 COOLING MAX V METERS COVER MTG. SCREWS (2) RETAINING PINS (2) METER Figure 1. Thermostat Detail 2 9/16" (65) 3 1/4" (83) WIRE CLAMP TERMINAL HEATING SLIDER COOLING SLIDER (WHERE APPLICABLE) Maintenance: No routine maintenance is required. Each component s design and material selection assures dependable long-term reliability and performance. Careful installation will also enhance long term reliability and performance. CSP-52 DAMPER CONTROLLER/ACTUATOR All Nailor standard right hand (and optional left hand) terminal units have a 1/2" (13), diameter drive shaft and a clockwise to close damper rotation (Dual Duct Left Hand Deck CCW to close). Full damper shaft rotation is 45 or 9 degrees depending on model. The CSP-52 should be mounted on the damper drive shaft so the actuator will stall at either end of the stroke to ensure tight shut-offs and full rotation. Ensure the two jumpers are set for the correct damper rotation. The CSP-52 has a tri-color LED that indicates the current action of the damper: RED Closing, GREEN Opening, WHITE Satisfied. The CSP-52 provides pressure independent VAV control for terminal unit primary valves. Primary air volume is monitored by the use of a multi-point flow sensor located in the inlet duct. Differential pressure is measured by an onboard platinum transducer. The changes in the inlet static pressure will vary the position of the inlet damper. Flow limit adjustments are made using a digital DC voltmeter at the thermostat. The CSP-52 is factory calibrated with VNOM adjustment centered for the enclosed voltage - airflow charts. Do not adjust. Dampers are always shipped in the full open position. FIELD ADAPTABLE AUXILIARY SWITCH NON-ROTATION SLOT 1 1/2" (38) 9 45 51" (13) DIA. ADJUSTABLE END STOPS DAMPER SHAFT DRIVE HUB 5/16-18 SET SCREWS (2) P PORTS 3/16" (5) DIA. (2) GEAR DISENGAGE MENT BUTTON H L 6 7/64" (155) 6 15/32" (164) 5 1/16" (129) RED DAMPER SHAFT ROTATION JUMPERS ACESS DOOR 4" (12) GREEN 5/8" (16) DIA. WIRE ACCESS SHUTTER BUSINESS NON-ROTATION TAB 3 1/8" (79) Figure 2. CSP-52 Controller / Actuator POWER REQUIREMENTS: Controller / actuator / thermostat is 7VA plus any output loads for fan relays, heating contactors and control valves (assume 1 VA each). Always switch control voltage off prior to disconnecting any wires from the controller. Page 2 of 1

ANALOG CONTROL CALIBRATION CHARTS VOLTAGE VS. AIRFLOW When field adjustment or field calibration of the CTE-51 series thermostats is necessary, desired limit control can be calculated using the tables in Figure 3 and the following formulas, or the charts presented in Figures 4 through 8. Formulas: CFM = K (VDC - Offset) VDC = (CFM/K) + Offset Follow the individual calibration procedure for the thermostat model(s) as required. Inlet size K factor Offset 4 in. Round 33 +.44 5 in. Round 55 +.2 6 in. Round 75 +.8 7 in. Round 115 -.19 8 in. Round 143 +.32 9 in. Round 175 +.1 1 in. Round 233 +.9 12 in. Round 357 -.4 14 in. Round 5 -.7 16 in. Round 625 -.25 Inlet size K factor Offset 12 in. Oval 333 -.22 14 in. Oval 417 -.47 16 in. Oval 588 +.5 18 in. Oval 759 -.27 Inlet size K factor Offset 14 x 1 417 -.14 24 x 16 125 -.7 Figure 3. Diamond Flow Sensor K Factors. 7. 6. 5. 4 5 6 VOLTS, DC 4. 3. 2. 1. 1 2 3 4 5 6 AIRFLOW,CFM Figure 4. Inlet Sizes 4, 5, 6 Round Page 3 of 1

8. 7. 6. 5. 7 8 9 1 VOLTS, DC 4. 3. 2. 1. 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 AIRFLOW,CFM Figure 5. Inlet Sizes 7, 8, 9, 1 Round 7. 6. 12 14x1 5. 14 16 VOLTS, DC 4. 3. 2. 1. 5 1 15 2 25 3 35 4 AIRFLOW,CFM Figure 6. Inlet Sizes 12, 14, 16 Round. 14 x 1 Rectangular Page 4 of 1

7. 6. 12 14 5. VOLTS, DC 4. 3. 16 2. 1. 5 1 15 2 25 3 35 4 AIRFLOW,CFM Figure 7. Inlet Sizes 12, 14, 16 Oval (Single Duct Only) 7. 6. VOLTS, DC 5. 4. 3. 18 24x16 2. 1. 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 AIRFLOW,CFM Figure 8. Inlet Size 18 Oval. 24 x 16 Rectangular Page 5 of 1

CALIBRATION PROCEDURE FOR AIR VOLUME ADJUSTMENTS MADE AT THERMOSTAT Thermostats are factory calibrated when minimum and maximum airflow limits are provided. Field calibrations are as follows: Minimum and maximum setpoints (air volume limits), are set at the thermostat. Check the CSP-52 controller to ensure that the minimum and maximum potentiometers are dialed completely out ( CCW, CW), so that the thermostat signal is not restricted. A Required Tools: 1. Small flat blade screwdriver 1/8" / 3 mm 3. Hex Wrench 1/16" / 2mm for the cover screws 2. Digital voltmeter w/dc range to hundredths 4. A test lead (HSO-51) is recommended for meter readings B Remove Thermostat Cover: Thermostat cover is removed by turning the two set screws CW, (which are located on the short sides of the thermostat). Remove cover and setpoint slider stops if installed. SCALE PLATE ( F OR C) MAX/AUX MIN MIN MAX COVER MTG. SCREWS (2) METER TAP HEATING COOLING V METERS KMC Controls 5 7 9 V METERS RETAINING PINS (2) METER VELOCITY VELOCITY MIN. & MAX. HEATING SLIDER (WHERE APPLICABLE) 3 1/4" (83) COOLING SLIDER Figure 9. Thermostat scaleplate detail. CTE 511 SINGLE SETPOINT THERMOSTAT (DA T1 with limits, T3 without limits) 1. Ambient temperature at the thermostat must be between 55 O F 85 O F (13 O C 29 O C). 2. Adjust the setpoint slider all the way to the right for minimum cooling. Connect voltmeter to the cooling (right side) voltmeter taps. The center and right tap provide the VDC readings (min/max airflow). The center and left tap provide the actual air volume (live velocity) reading when thermostat V1, is connected to the controller OUT terminal. 3. Read the VDC across the taps. Adjust the MIN potentiometer to the VDC equal to the desired air volume as shown on the chart. NOTE: The minimum setpoint must be set first. Adjustment of the minimum potentiometer directly affects the maximum setpoint. 4. Adjust the setpoint slider all the way to the left for maximum cooling. 5. Read the VDC across the taps. Adjust the MAX potentiometer to the VDC equal to the desired air volume as shown on the chart. NOTE: The maximum setpoint must be set last. Adjustment of the minimum potentiometer directly affects the maximum setpoint. 6. Return the setpoint slider to the desired setpoint. Install the optional setpoint stops if required and replace thermostat cover. CTE - 513 DUAL SETPOINT THERMOSTAT (Heat / Cool Changeover) (DA T1/T3. RA T2/T4. T1, T2 with limits, T3, T4 without limits) Cooling side of thermostat 1. Follow steps 1 through 5 for the CTE-511 thermostat. Note: Be sure to adjust the cooling setpoint slider all the way to the left for maximum cooling. (The heating setpoint sider will have to be adjustable all the way to the left also). Heating side of thermostat 1. Ambient temperature at the thermostat must be between 55 O F - 85 O F (13 O C - 29 O C). 2. Adjust the heating setpoint slider all the way to the left for minimum heating. Connect voltmeter to the heating (left side) voltmeter taps. The center and right tap provides the VDC readings (min/max airflow). 3. Read the VDC across the taps. Adjust the MIN potentiometer to the VDC equal to the desired air volume as shown on the chart. NOTE: The minimum setpoint must be set first. Adjustment of the minimum potentiometer directly affects the maximum setpoint. 4. Adjust the heating slider all the way to the right for maximum heating. 5. Read the VDC across the taps. Adjust the MAX potentiometer to the VDC equal to the desired air volume as shown on the provided chart. NOTE: The minimum setpoint must be set first. Adjustment of the minimum potentiometer directly affects the maximum setpoint. 6. Return both setpoint sliders to the desired setpoints. Install the optional setpoint stops if required and replace thermostat cover. Page 6 of 1

CTE 514 DUAL SETPOINT THERMOSTAT (DA T1/T3. RA T2. T1 with limits, T2, T3 without limits) Cooling side of the thermostat 1. Follow steps 1 through 5 for the CTE-511 single setpoint thermostat. Note: Be sure to adjust the cooling setpoint slider all the way to the left for maximum cooling. (the heating setpoint slider will have to be adjustable all the way to the left also). Adjustment of the Auxiliary Setpoint - Higher reheat minimum (if required). 2. Read the VDC across the meter taps on the heating (left) side of the thermostat. With the left hand slider in the full heat position, completely to the right, adust the MAX/AUX potentiometer to the VDC equal to the desired air volume as shown on the chart. If a higher Aux Min is not required, dial fully CCW. 3. Return both setpoint sliders to the desired setpoints. Install the optional setpoint stops if required and replace thermostat cover. CTE 515 DAY / NIGHT THERMOSTAT (Night Temperature Set Back) (DA T1/T2/T3/T4. T1/T2 with limits, T3/T4 without limits) Day side of thermostat 1. Follow steps 1 through 5 for the CTE-511 thermostat. Note: Be sure to adjust the day setpoint slider all the way to the left for maximum cooling. The night setpoint slider will have to be adjusted all the way to the left also. 2. Return both setpoint sliders to the desired setpoints. Install the optional setpoint stops if required and replace thermostat cover. Night side of thermostat 1. Follow steps 1 through 5 for the CTE-51 thermostat. Note: Be sure to adjust the night setpoint slider all the way to the right for minimum cooling. The day setpoint slider will have to be adjusted all the way to the right also. 2. Return both setpoint sliders to their desired setpoints. Install the optional setpoint stops if required and replace thermostat cover. 1 T3 1 T4 T3 VDC Output 5 T1 VDC Output 5 T2 T1-2 O F S.P. +2 O F -2 O F Rev. Act. S.P. +2 O F -2 O F Dir. Act. S.P. +2 O F (Heating) (Cooling) CTE-511 Thermostat CTE-513 Thermostat 1 T2 T3 1 T4 T3 VDC Output 5 aux. T1 VDC Output 5 T2 T1-2 O F Rev. Act S.P. Dir. Act. S.P. +2 O F (Heating) (Cooling) -2 O F Dir. Act. S.P. +2 O F -2 O F Dir. Act. S.P. +2 O F (Night) (Day) CTE-514 Thermostat CTE-515 Thermostat Figure 1. Thermostat action schematics. Page 7 of 1

GENERAL INFORMATION FOR ALL TERMINAL UNITS Checkout Procedure The CSP-52 actuator will take up to 2.5 minutes for a 45 degree stroke damper and up to 5. minutes for a 9 degree stroke damper to cycle from its minimum to its maximum setting and vice versa. It is important therefore when verifying minimum and maximum flow limits, by moving the slider(s) right or left as previously described, to wait sufficient time to ensure the actuator has moved to its correct position and that the live velocity read-out (if used) has settled. Live Supply Volume Readout A voltage output corresponding to actual primary air volume may be monitored at the room thermostat to assist in balancing and troubleshooting. The output signal is the same as the airflow volume vs. DC voltage calibration curve. The test lead (HSO-51) is connected to the innermost meter taps on the thermostat scaleplate (see Figure 9). Supply Air Temperature Sensing A duct mounted temperature sensor (thermistor) is used to measure primary air temperature in control sequences involving automatic changeover (ACO) or morning warm-up (MWU). The probe is attached to the inlet collar and wired to the low voltage controls enclosure. To ensure proper operation for auto changeover, a minimum flow setting should be used for both heating and cooling modes. This allows airflow to constantly pass over the duct temperature sensor. Proportional Reheat Control Hot water valves and SCR controllers with a -1 Vdc control signal (1mA max,) are wired (+) to terminal T2 on the thermostat and (-) to the grounded side of the low voltage control circuit. T2 is an output with limits and it must therefore be ensured that the thermostat limits are dialed out ( pot. fully CW and pot fully CCW) for unrestricted operation. FAN POWERED TERMINAL UNITS Night Shut Down Units ordered with optional Night Shut Down (NSD) sequences employ an airflow switch to sense when primary air has been shut down. When the airflow switch opens the fan and optional heat are shut down. Upon the primary air starting, the airflow switch will close and return the unit to normal operation. Night Temperature Setback Units ordered with optional Night Temperature Setback (NTSB) sequences employ an airflow switch to sense when the primary air (central air handler) has been shut down. When the airflow switch opens, a lower night time temperature setpoint is initiated. The unit fan and optional supplementary heat will cycle intermittently to maintain night setpoint temperature. Upon start up of the central air handler, the unit will return to daytime operation. Amount of setback is either fixed or adjustable dependent on control sequence. Refer to control submittal. Night Cycle On series units with optional night cycle sequences, an airflow switch de-energizes unit fan upon loss of primary (central system) air. Upon a call for heat, the thermostat will override the airflow switch and cycle the unit fan followed by any supplementary heat intermittently to maintain day setpoint temperature. On parallel units, basic control sequences cycle the fan and supplementary heat intermittently as standard in response to thermostat demand. This will therefore still occur at night when the central air has been shutdown. Checkout Procedure (Day / Occupied Mode) Series Fan Powered Terminal Units: The fan should be energized regardless of slider(s) position. Dependent on control sequence ordered, thermostat may have one or two sliders. Consult control sequence submittal / wiring diagram and thermostat calibration procedure. Parallel Fan Powered Terminal Units: Fan will only cycle upon a call for heat. Move single slider (or both if a separate heating or night slider is present) full right to energize fan. Dependent on control sequence ordered, thermostat may have one or two sliders. Consult control sequence submittal / wiring diagram and thermostat calibration procedure. Checkout Procedure (Night / Unoccupied Mode) Move thermostat slider(s) full right to energize fan and supplementary heat. Page 8 of 1

REE 52 Relay Module Fan with 2 Stage Reheat The REE-52 is used in all parallel flow terminal units, and specific series flow terminal units with the night cycle or setback options. The relay cycles the fan and activates up to 2 stages of heat in response to a direct acting -1 Vdc thermostat output. The fan start point is adjustable from 3-8 Vdc which equates to -.8 to +1.2 O F,(-.4 to +.7 O C), around setpoint. The factory setting is 4 Vdc (-.4F below cooling setpoint / primary airflow setting). To field adjust, read the Vdc across terminals "X" and "-". Adjust the potentiometer to Vdc desired setpoint. The two stages of heat are sequenced to energize after the fan is activated when the desired room temperature continues to decrease. X T USE TERMINAL "X" FOR MEASURING FAN TRIP VOLTAGE ONLY I N C R REE-52 CAUTION KMC INC CONTROLS ~ -- 24 VAC LOAD FAN 1 2 FAN #1 #2 24 VAC ~ 24 VAC -- CSP-51 CONTROLLER-ACUATOR 24VAC CONTACTORS 1VA MAX PER STAGE T3 CTE-51 SERIES THERMOSTAT DIRECT ACTING + - DC VOLT METER S 2 T A 1 G E FAN S FAN START POINT ADJUSTABLE 3-8 VOLTS 1 3 8 VOLTS THERMOSTAT SIGNAL (T3) (1 VDC SWITCHING DIFFERENTIAL) Figure 11. Ree-52 Relay Module. Fan with 2 stage reheat. TROUBLESHOOTING PROCEDURE Note: Turn off power before making any wiring changes to the unit. 1. Verify 24 Vac at CSP-52 controller / actuator terminals "~" (phase) and "-"(ground). Tolerance +2 / -15% (2.4-28.8 Vac). When using a common transformer for more than one CSP-52, polarity should be observed. 2. Check correct field wiring from thermostat to terminal block in unit low voltage enclosure. Refer to Nailor control wiring diagram inside controls enclosure. Ensure all wiring connections are tight and secure. 3. Check tubing from unit inlet flow sensor to the controller / actuator is correct and no leaks. "Hi" side of sensor to "H" on controller / actuator and "Lo" side of sensor to "L" on controller / actuator. 4. Verify 16 Vdc at CSP-52 terminals "16 VDC" and "-". Tolerance is 15 to 17 Vdc power supply to thermostat. If not correct, disconnect thermostat and recheck. If still incorrect, replace CSP-52 controller / actuator. 5. Check requested minimum and maximum flow settings on terminals "IN" and "-". Refer to Vdc vs. Airflow setting charts at back of this document. If reading is not what is desired, refer to thermostat calibration procedure. 6. Check actual airflow (live velocity readout) voltage on terminal "OUT" and "-" ( 1 Vdc). Use calibration charts provided. 7. Check for damper movement and correct rotation. a) Review "requested flow" and actual flow" above to determine if unit should be satisfied (within 5 fpm +/-.2 Vdc) or driving damper open or closed. b) If damper is not moving, verify damper is not stuck at end of travel and has free movement. Use manual release clutch on CSP-52. Check CW / CCW rotation jumpers for proper operation. Ensure damper actuator connection is correct and damper can travel fully open to fully closed within limits of the actuator stroke. Check actuator coupling to damper shaft setscrews are tight. c) Change "requested flow" to make unit drive opposite direction (verifying correct damper movement). This can be accomplished by moving thermostat setpoint sliders or: i) To manually open damper, remove wire from terminal "IN" and jumper terminal "IN" to 16Vdc". This will tell unit to control at full airflow and the green LED should turn on, driving damper fully open. ii) To manually close damper, remove wire from terminal "IN" and jumper terminal "IN" to "-" terminal. This will tell unit to control at zero airflow and the red LED should be on, driving damper fully closed. Warning: Never jumper terminal "16 Vdc" to "-", as this will cause short and possibly damage the power supply. Page 9 of 1

COMPONENTS, ACCESSORIES, REPLACEMENT PARTS DESCRIPTION VENDOR PART NO. NAILOR PART NO. KMC Controller / Actuator CSP-52 V34 (Kreuter) Controller / Actuator CSP-466 V35 Controller / Actuator CSP-4616 V36 In-line filter for CSP-4XXX HFO-34 V37 KMC (Kreuter) Room Thermostat and accessories: CTE-51 Series - ( -1 Vdc): DA clg. (base only) CTE-511 V33 DA clg. / RA htg. (base only) CTE-513 V331 DA clg./ra reheat (base only) CTE-514 V332 DA / DA (Day / Night) (base only) CTE-515 V333 Accessories for CTE-51 Series: Thermostat Cover - light almond HPO-1511 V16 - White HPO-1512 V161 Backplate mounting kit (for mounting to a 2 x 4 handy box) - light alomd HMO-524 V162 - White HMO-526 V163 Mounting Strap kit (for mounting on holllow wall) HMO-523 V164 Horizontal Scale Plate - O F HPO-6-1 V169 - O C HPO-6-11 V17 Miscellaneous: KMC Electric reheat relay module, 3 stage REE-51 V35 KMC Wet heat time prop. relay module DA/NC valve REE-516 V353 RA/NO valve REE-5123 V354 KMC Fan/elec. heat relay module, 2 stage REE-52 V355 KMC Fan/wet heat time prop. relay module DA/NC valve REE-517 V356 RA/NO valve REE-524 V357 KMC Constant volume relay module REE-14 V358 KMC Heat / Cool changeover module REE-15 V359 KMC Duct temp. changeover sensor (for use with REE-15) STE-12 V36 Airflow Switch FS-BO-182 V361 DPDT Relay 24V. 91-233Q323 V362 Transformers (foot mount): 12 to 24 V. 4 VA - VH1-669 12 to 24 V. 5 VA - VH1-692 28/24 to 24 V. 4 VA - VH1-67 28/24 to 24 V. 5 VA - VH1-685 277 to 24 V. 4 VA - VH1-675 277 to 24 V. 5 VA - VH1-674 277 to 24 V. 75 VA - VH1-677 48 to 24 V. 5 VA - VH1-686 28/24/48 to 24 V. 4 VA - VH1-671 12/28/24/48 to 24 V. 75 VA - VH1-689 24 to 24 V. 4 VA - VH1-673 Houston, Texas Tel: 281-59-1172 Fax: 281-59-386 Las Vegas, Nevada Tel: 72-648-54 Fax: 72-638-4 Toronto, Canada Tel: 416-744-33 Fax: 416-744-336 Calgary, Canada Tel: 43-279-8619 Fax: 43-279-535 Page 1 of 1 C o m p l e t e A i r C o n t r o l a n d D i s t r i b u t i o n S o l u t i o n s. w w w. n a i l o r. c o m