Fire Outcomes by General Construction Type A Retrospective Analysis of British Columbia Reported Fires

Similar documents
What are the Concerns and How Can we Mitigate

Sprinkler Systems and Fire Outcomes in Multi-Level Residential Buildings

Residential Fire Injury and Death Rates in British Columbia

Smoke Alarm Response Time:

Assessing the Safety of Smart Meter Installations in British Columbia: Analysis of Residential Structure Fires in BC between July 2010 and June 2017

Assessing the Safety of Smart Meter Installations in British Columbia: Analysis of Residential Structure Fires in BC between July 2010 and June 2016

Canadian Wood Council Fire and Safety Risks Posed by Wood Frame Residential Construction Professor / Fire Chief Len Garis July 15, 2015

Sprinkler Systems and Residential Structure Fires - Revisited:

Smoke Alarms Work, But Not Forever

Fire Prevention Education Delivered by OnDuty Fire Fighters

Fire Sprinklers Working Group Final Report


Smoke Alarms Work, But Not Forever: Revisited. Successes and Ongoing Challenges from BC s Working Smoke Alarm Campaign

Structure Fires in Hotels and Motels

VICTORIA BC V8R 1C4. # of Occupants (At time of fire): 30 # of Injured: 0 # of Deaths: 0 Total Dollar Loss Estimate:

Study confirms cooking, smoking are top causes of house fires

A Review of a White Paper on Residential Fire Sprinklers

CITY CLERK. Parkland Acquisition Strategic Directions Report (All Wards)

Merging safely: addressing blind spots to fire hazards in the proposed framework for the legalization and regulation of Cannabis

3. Endorse the LRT vision in transforming Surrey into Connected-Complete-Livable communities, and more specifically, the official vision statement:

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage


University of Pretoria

research highlight Canadian Housing Fire Statistics Findings

Fire statistics in Canada, Selected Observations from the National Fire Information Database 2005 to 2014

THE TRUTH ABOUT SMART METER FIRES AND FAILURES IN BRITISH COLUMBIA

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw

SELECTIONS FROM HOME COOKING FIRE PATTERNS AND TRENDS CHARCOAL GRILLS

APPENDIX 4J SECURITY AND SURVEILLANCE SERVICES

Which burglary security devices work for whom and in what context? Briefing Note 1. September Background

Home Fires Involving Heating Equipment

OPERATIONAL GUIDELINE. Office of the Fire Commissioner O.G.# Revision #1 TITLE: ISSUING ORDERS Page 1 of 8

Development of an Environmental and Economic Assessment Tool (Enveco Tool) Francine Amon, Jonatan Gehandler, Selim Stahl

9 CITY OF VAUGHAN OFFICIAL PLAN AMENDMENT NO BOCA EAST INVESTMENTS LIMITED

Montgomery County Community College FSC 108 Fire Protection Systems 3-3-0

Secretary of State determination under article 36 of the Fire Safety Order

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

Road Safety Impact Assessment

BENEFITS of RESIDENTIAL FIRE SPRINKLERS:

2009 Community Excellence Award DOWNTOWN LANGLEY MASTER PLAN

U.S. STRUCTURE FIRES IN OFFICE PROPERTIES

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii

Establishing the Risk Basis of Building Size Limits

DATA LIMITATION.

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

Structure Fires in Residential Board and Care Facilities

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

Proposed Plan Change 55: District Wide Rules. Hearing Report

Virginia TrueAllele Validation Study: Casework Comparison. One person, one genotype. DNA data. Cybergenetics

Intention to Designate under Part IV, Section 29 of the Ontario Heritage Act 844 Don Mills Road and 1150 Eglinton Avenue East

Evaluation of Strobe Lights in Red Lens of Traffic Signals

Single Room Occupancy Hotel Safety & Stabilization Task Force

A Guide to the Open Burning Smoke Control Regulation

UNDERSTANDING ELECTRICAL SAFETY RISKS

22A Belvedere Avenue, Parry Sound Sprinkler System Consulting Review

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

High Rise Buildings with Combustible Exterior Wall Assemblies: Fire Risk Assessment Tool

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

AUTOMOTIVE ENGINE HEATERS*

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

Jurnal Fikrah Jilid 8, Special Issue 1, , 2017

The Corporation of the Town of Milton

SUBJECT: Waterfront Hotel Planning Study Update TO: Planning and Development Committee FROM: Department of City Building. Recommendation: Purpose:

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Miami Valley Regional Planning Commission Regional Land Use Planning

Management Practices: Fire Protection Impairments November 2015

Town of Cobourg Heritage Master Plan. Statutory Public Meeting

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Northern Branch Corridor SDEIS March 2017

BRIDGECLIMB SYDNEY REDUCING TONAL NOISE FROM SAFETY LATCHES

CIRRICULUM VITAE MICHAEL A. GINN

Wayside horn noise investigation

Abstract. Introduction

Services Department B September 10, 2007

DESIGN FOR ELDERLY EGRESS IN FIRE SITUATIONS

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

Branch Capital Projects Feasibility Study

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Report to: Development Services Committee Report Date: September 11, 2017

TOWN OF BIGGAR OPEN OUTDOOR FIRE BYLAW BYLAW NO A BYLAW TO REGULATE OPEN OUTDOOR FIRES

THE SMOKING-MATERIAL FIRE PROBLEM

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

WASHINGTON STATE PATROL

Planning and Growth Management Committee. Chief Planner and Executive Director, City Planning Division. Pg12013 (File No NNY 34 OZ)

ONTARIO MUNICIPAL BOARD

Strategic Environmental Assessment Screening Report. Dublin Port Masterplan Review 2017

Heating Fires in Residential Buildings

Case Study Presentation of the Downtown Brampton Flood Protection Class EA

Statue of Liberty: A Risk Analysis

Master Planning: Cuba, New York Phase II. Dr. John Anderson President Alfred State College. Alfred New York

Verisure impact on client burglary risk page 1 HOW MUCH DOES VERISURE REDUCE THE BURGLARY RISK FOR THEIR CLIENTS?

BYLAW NO (CONSOLIDATED)

REQUEST FOR PROPOSAL No Fire Extinguishers, Fire Suppression, Fire Alarms, Emergency Lighting & Sprinkler Systems Maintenance

Cotswolds AONB Landscape Strategy and Guidelines. June 2016

About This Report. Risk Id: 32 NC N Church St Charlotte NC Mecklenburg County Last Update: 3/1/2015 On-Site Survey: 3/1/2015

TERMS OF REFERENCE MALASPINA COMPLEX COASTAL PLAN

U.S. Firefighter Disorientation Study Prepared by William R. Mora, Captain San Antonio Fire Department San Antonio, Texas.

Transcription:

Fire Outcomes by General Construction Type A Retrospective Analysis of British Columbia Reported Fires Fire Chief Len Garis and Dr. Joseph Clare February 2014

Overview of this Research This report examines British Columbia (BC) building fires as a function of the general construction type. The fires that are examined were reported to the BC Office of the Fire Commissioner (OFC) between October 20 2008 and October 19 2013. The data included in this analysis was provided by 339 reporting agencies across the province, sampled from first nations band areas, non-municipal areas (with and without fire protection), and municipal areas. Comparisons were drawn between 11,875 fires that occurred in the five broad general construction type categories: (1) combustible construction open wood joist (also called combustible construction throughout this report, n = 2,241), (2) protected combustible construction wood protected by plastic/gyproc (also called protected combustible construction throughout this report, n = 7,808), (3) heavy timber construction (n = 226), (4) non-combustible construction (n = 507), and (5) protected noncombustible construction protected steel or concrete (also called protected non-combustible construction throughout this report, n = 1,093). Across all these fires there were a total of 772 injuries and 107 deaths reported to the OFC. The analysis revealed the following main findings with respect to fires that occurred in these various construction types: Almost two-thirds of the sample of fires examined here occurred in buildings made of protected combustible construction. Initial analysis revealed differences in the extent to which fires were contained to at least the room of origin with respect to the different construction types. However, when complete sprinkler protection was incorporated into this analysis, the patterns of fire spread across construction types were much more comparable; Variations in the methods by which the fires were controlled as a function of the general construction type can be interpreted with respect to difference in the presence of effective fire safety systems (e.g., functioning smoke alarms and complete sprinkler protection) and do not necessarily relate to construction type; Initial variations in the fire-related casualties (injuries and deaths) were observed when analysing all fires without acknowledging the significance of fire safety systems (e.g., complete sprinkler protection and activated smoke alarms). When these systems were included in the analysis, no fatalities were observed in the remaining fires, regardless of construction type. Regardless of the life safety systems, the rates of injuries were always highest for fires that occurred in protected combustible construction ; and Fire-related injuries were found to be more frequent for fires that activated a smoke alarm, which is consistent with by prior research by the authors. No policy or practice recommendations are made as a consequence of these findings, as this is a retrospective analysis and there are limitations with the data that prevent specific conclusions being drawn. The Scope of the Dataset The 11,875 fires in examined here were taken from a larger set of 34,708 fires that occurred in BC between October 20, 2008 and October 19, 2013 that were reported to the BC OFC. 1 Therefore, the sample of fires included here represents 34.2% of all residential fires reported during this time period. Overall, this sample included fires that resulted in 772 fire-related injuries and 107 deaths. The frequencies of fires, deaths, and injuries across these five general construction types are presented in Table 1. As explained above, 339 1 General construction type was based on GC codes GC1000 to GC5000, inclusive, BC Fire Reporting Manual. 1

reporting locations across the province submitted reports for fires that were included in this data set. Examination of the sample of fires retained for subsequent analysis in this report reveals that almost twothirds (65.8%) occurred in constructions made of protected combustible construction, which accounted for 75 percent of the total injuries and 62 percent of the fatalities. In contrast, fires in combustible construction accounted for 14 percent of injuries and 30 percent of deaths. TABLE 1: FREQUENCIES OF FIRES, DEATHS, AND INJURIES BY GENERAL CONSTRUCTION TYPE Full sample of reported fires Retained for subsequent analysis General construction type # fires % fires # injured # death # fires % fires # injured # death Combustible construction - 2,241 6.5% 112 32 2,241 18.9% 112 32 open wood joist Protected combustible 7,808 22.5% 579 66 7,808 65.8% 579 66 construction - wood protected by plaster/gyproc Heavy timber construction 226 0.7% 10 2 226 1.9% 10 2 Non-combustible 507 1.5% 22 1 507 4.3% 22 1 construction - exposed steel Protected non-combustible 1,093 3.1% 49 6 1,093 9.2% 49 6 construction - protected steel or concrete Cannot be determined 1,248 3.6% 52 17 General construction - 1,317 3.8% 74 23 unclassified Not applicable (e.g., vehicle, 20,268 58.4% 135 51 outdoor, person) Grand Total 34,708 100.0% 1033 198 11,875 100.0% 772 107 The Extent of Fire Spread as a Function of General Construction Type The extent of fire spread from the point of origin was examined as a function of the building general construction type. The initial analysis of the fire spread looked at all fires in each building, regardless of the presence of complete sprinkler protection in each structure, with the results displayed in Figure 1. This figure demonstrates large variations between construction types with respect to the frequency at which fires were confined to at least the room of origin: combustible construction (51%), protected combustible construction (71%), heavy timber construction (47%), non-combustible construction (76%), and protected non-combustible construction (92%). 2

FIGURE 1. THE EXTENT OF FIRE SPREAD BY GENERAL CONSTRUCTION TYPE, IGNORING THE INFLUENCE OF SPRINKLER PROTECTION (N = 11,875) These patterns displayed in Figure 1 only give partial perspective into the variation in fire spread with respect to the different general construction types. As can be seen from Table 2, there is a large degree of variation for the presence of fire safety systems (particularly functioning smoke alarms and complete sprinkler protection) across the buildings that are the focus of this analysis. The sprinkler protection varies from 5 percent of the combustible construction sample to 51 percent for the protected non-combustible construction buildings that experienced fires. The same pattern was observed for smoke alarm activation, ranging from 19 percent for combustible construction buildings up to 48 percent for protected non-combustible construction. Consequently, it was important to re-examine the patterns for fire spread by construction type to examine the significance of complete sprinkler protection (with the outcome displayed in Figure 2, below). In contrast to the initial analysis and focusing on those buildings that had complete sprinkler protection, Figure 2 demonstrates much less variation between construction types with respect to the frequency at which fires were confined to at least the room of origin: combustible construction (91%), protected combustible construction (88%), heavy timber construction (80%), non-combustible construction (85%), and protected non-combustible construction (94%). TABLE 2: FREQUENCIES OF FIRES, SPRINKLER PROTECTION (%), SMOKE ALARM ACTIVATION (%), DEATH RATE AND INJURY RATE BY GENERAL CONSTRUCTION TYPE % sprinkler % smoke alarm Death Injury General construction type # fires protected activated rate rate Combustible construction - open wood joist 2,241 5.0% 18.8% 14.3 50.0 Protected combustible construction - wood protected by 7,808 10.1% 33.9% 8.5 74.2 plaster/gyproc Heavy timber construction 226 21.7% 19.5% 8.8 44.2 Non-combustible construction - exposed steel 507 48.1% 22.1% 2.0 43.4 Protected non-combustible construction - protected steel or 1,093 51.1% 48.3% 5.5 44.8 concrete Total 11,875 14.8% 31.6% 9.0 65.0 3

FIGURE 2. THE EXTENT OF FIRE SPREAD BY GENERAL CONSTRUCTION TYPE, FOR THOSE FIRES IN BUILDINGS WITH COMPLETE SPRINKLER PROTECTION ONLY (N = 1,754) The Method of Fire Control as a Function of General Construction Type The various frequencies of the methods of fire control used are displayed in Figure 3, as a function of the building general construction type. There are clear differences between the construction groups with respect to the method of fire control. It is anticipated a range of factors are responsible for these patterns, however, and given the findings demonstrated in Figure 2, above, it is reasonable to assume these results reflect variations in building safety systems rather than being a function of the construction type involved. FIGURE 3. THE METHOD OF FIRE CONTROL BY GENERAL CONSTRUCTION TYPE 4

Fire-Related Casualties as a Function of General Construction Type The overall patterns for fire-related casualties (injuries and deaths) are displayed in Table 3, separated out by the general construction type of the buildings. This initial analysis indicates a greater injury and death rate for the three timber construction types, relative to the steel and/or concrete construction types. However, to continue to explore the significance of the fire safety systems in each construction type, some additional analysis was undertaken. First, the patterns for fire-related casualties were examined with respect to complete sprinkler protection (Table 4), next these patterns were explored with respect to the presence of an activated smoke alarm (Table 5), and finally the patterns were looked at with respect to fires in buildings with both complete sprinkler protection and an activated smoke alarm (Table 6). As can be seen from this combination of tables, the death rate reduces when in the presence of a working smoke alarm, and drops to 0 for all construction types in the presence of complete sprinkler protection. The pattern for injuries shows a reduction for sprinkler protected fires (relative to the full-sample) but an increase for the smoke alarm activated fires. This pattern is consistent with previous work by these authors [e.g., 1, 2]. Overall, injuries were most common in protected combustible constructions regardless of the combination of fire safety systems in place. TABLE 3. FIRE-RELATED CASUALTIES BY GENERAL CONSTRUCTION TYPE ALL FIRES (N = 11,875) General construction type # fires % fires # injured Injury rate # death Death rate Combustible construction - open wood joist 2,241 18.9% 112 50.0 32 14.3 Protected combustible construction - wood protected 7,808 65.8% 579 74.2 66 8.5 by plaster/gyproc Heavy timber construction 226 1.9% 10 44.2 2 8.8 Non-combustible construction - exposed steel 507 4.3% 22 43.4 1 2.0 Protected non-combustible construction - protected 1,093 9.2% 49 44.8 6 5.5 steel or concrete Grand Total 11,875 100.0% 772 65.0 107 9.0 TABLE 4. FIRE-RELATED CASUALTIES BY GENERAL CONSTRUCTION TYPE SPRINKLER PROTECTED FIRES (N = 1,754) General construction type # fires % fires # injured Injury rate # death Death rate Combustible construction - open wood joist 112 6.4% 0 0.0 0 0.0 Protected combustible construction - wood 790 45.0% 38 48.1 0 0.0 protected by plaster/gyproc Heavy timber construction 49 2.8% 1 20.4 0 0.0 Non-combustible construction - exposed steel 244 13.9% 4 16.4 0 0.0 Protected non-combustible construction - protected 559 31.9% 17 30.4 0 0.0 steel or concrete Grand Total 1,754 100.0% 60 34.2 0 0.0 5

TABLE 5. FIRE-RELATED CASUALTIES BY GENERAL CONSTRUCTION TYPE SMOKE ALARM ACTIVATED FIRES (N = 3,755) General construction type # fires % fires # injured Injury rate # death Death rate Combustible construction - open wood joist 421 11.2% 23 54.6 5 11.9 Protected combustible construction - wood 2,650 70.6% 247 93.2 12 4.5 protected by plaster/gyproc Heavy timber construction 44 1.2% 0 0.0 0 0.0 Non-combustible construction - exposed steel 112 3.0% 8 71.4 0 0.0 Protected non-combustible construction - protected 528 14.1% 33 62.5 2 3.8 steel or concrete Grand Total 3,755 100.0% 311 82.8 19 5.1 TABLE 6. FIRE-RELATED CASUALTIES BY GENERAL CONSTRUCTION TYPE SMOKE ALARM ACTIVATED AND SPRINLKER PROTECTED FIRES (N = 865) General construction type # fires % fires # injured Injury rate # death Death rate Combustible construction - open wood joist 54 6.2% 0 0.0 0 0.0 Protected combustible construction - wood 413 47.7% 26 63.0 0 0.0 protected by plaster/gyproc Heavy timber construction 15 1.7% 0 0.0 0 0.0 Non-combustible construction - exposed steel 75 8.7% 1 13.3 0 0.0 Protected non-combustible construction - protected 308 35.6% 16 51.9 0 0.0 steel or concrete Grand Total 865 100.0% 43 49.7 0 0.0 General Summary of Findings and Conclusion Overall, therefore, this analysis demonstrated that there appears to be little difference with respect to fire spread, death, and injury rates as a function of building general construction type, provided these buildings have functioning smoke alarms and complete sprinkler protection. Initially apparent vulnerabilities that appeared between construction types reduced when sprinklers were present and there was a functioning smoke alarm. Regardless of the construction material, for those buildings with these fire safety systems, these results demonstrated there were no fire deaths and remarkably similar fire spread, with most fires in all buildings contained to at least the room of origin. With these findings in mind, and in parallel with other research findings from the authors, it should be considered that more emphasis is placed on ensuring all buildings have operating, current, and optimal fire safety systems. In all cases, maintenance and safety system upgrades should be focused on ensuring optimal outcomes for life safety and reducing fire-related casualties. References 1. Garis, L. and J. Clare, Smoke alarms work, but not forever: posing the challenge of adopting multifaceted, sustained, interagency responses to ensuring the presence of a functioning smoke alarm, 2012, Centre for Public Safety and Criminal Justice Research, School of Criminology and Criminal Justice, University of the Fraser Valley. 2. Garis, L. and J. Clare, Fires that commence on balconies of multi-residential buildings: the importance of an external fire area of origin for residential fire outcomes, 2013, Centre for Public Safety and Criminal Justice Research, School of Criminology and Criminal Justice, University of the Fraser Valley. 6

Author Biographical Information Len Garis is the Fire Chief for the City of Surrey, B.C. and is an Adjunct Professor in the School of Criminology and Criminal Justice at the University of the Fraser Valley, Affiliated Research Faculty at John Jay College of Criminal Justice, New York and a faculty member of the Institute of Canadian Urban Research Studies, Simon Fraser University. Contact him at LWGaris@surrey.ca. Dr Joseph Clare was the Strategic Planning Analyst for the Surrey Fire Service (BC) between 2010 and 2013, and is also an adjunct professor in the Crime Research Centre, University of Western Australia, and a faculty member of the Institute of Canadian Urban Research Studies (ICURS), Simon Fraser University. Contact him at joe.clare@uwa.edu.au. Acknowledgements Special thanks to the BC Office of the Fire Commissioner for the provision of the BC data discussed in this report. This work would not have been possible without the contributions of this organization. Additional thanks goes to the Building Standards Branch for BC, who identified this as a relevant research area. 7