THERMODYNAMIC STEAM TRAP

Similar documents
FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

STEAM TRAPS

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Liquid Drainers LIQUID DRAINERS

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

LIQUIDATOR UMT-TD Series Thermodynamic

THERMODYNAMIC STEAM TRAPS

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

BK 46. Installation Instructions Steam Trap BK 46

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

13-1. Temperature Regulator

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

CD-33/CD-33S Controlled Disc Steam Traps

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Installation and Maintenance Manual

INSTALLATION, OPERATION

THERMODYNAMIC STEAM TRAPS

Flange x Flange 20x32 to 200x300 Cast Iron. PN-16 Nodular iron. PN ºC Cast steel. PN-40 Stainless steel. PN-40 Metal

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

TECHNICAL DATA. Wet 26a. February 22, 2009

The right trap for the right application.

THERMOSTATIC STEAM TRAPS

FT14 Ball Float Steam Trap (Screwed)

MFP14 Automatic pumps. for condensate and other industrial fluids

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

Economical and simplified solutions that offer quality and optimum steam trap service.

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

SMK 22 SMK SMK SMK 22-82

MFP14 Automatic pumps for condensate and other industrial fluids

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Mikrotherm. Manual Radiator Valves With presetting

BK 45 BK 45-U BK 45-LT BK 46

569, 570, 571, 572 Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

569, 570, 571, 572 Series

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Inverted Bucket Steam Traps

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Inverted bucket steam traps Type OKZ PN6/PN16

Operating and installation instructions

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Our Know-How. Your Peace of Mind. Steam Solutions

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

ESCO. Committed. Group of Companies. to help conserve Steam Energy

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Yarway Narvik Steam Desuperheater Series 4300 TempLow

THE THERMOSTATIC STEAM TRAP

Radiator Trap Radiator Valve

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

STAINLESS STEEL TRAP VALVE STATION

568X, 587X, 588X Series

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

LIQUIDATOR 450 SERIES

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

CR20-07 A-F-A-E-HQQE 3x400/ HZ

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Audi-Larm Audible Alarm

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Disc Type Steam Trap TSD-42

Regulux. Radiator lockshield with drain-off facility. To be precise.

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Steam Traps and Steam Trap Testing

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

INSTALLATION, OPERATION

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Transcription:

THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses, vulcanizing autoclaves, pressure reduction equipment, etc. Specifications: Materials carefully selected for resistance to wear, extreme temperatures and corrosion. They can be fully recycled. Without joints. Simplicity of construction. One single moveable piece ensures minimum maintenance. Easy installation with possibility to be mounted in any position. Compact and robust. Reduced weight and size which facilitates storage. Internal design of the body is conceived to provide the capacities required in each case without over sizing. Characteristiques plate which enables identification of the working conditions and direction of flow. Discontinuous and intermittent discharge. Precision opening and closing, avoiding loss of steam. Silent, although allows acoustic verification of working. Remain unaffected by vibrations, water hammer, reheated steam, corrosive condensate, frosts, etc. Protective strainer for the closing surfaces with access cap for cleaning. (Mod. 043). Sealing surfaces treated and balanced, making them extremely tightness, even exceeding DIN-3230 requeriments. Page 3. All steam traps undergo throrough testing. Each component is numbered, registered and inspected. If previously requested, the steam trap will be accompanied by certificates corresponding to materials, batch, test and performance. IMPORTANT: Depending on demand: May be manufactured using other materials for specific working conditions (high temperatures, fluids, etc.). Other connections. Isolation covers to avoid losses through radiation caused mainly by bad weather. No. Piece Material 1 1 2 3 4 5 6 7 Body (Mod. 041) Body (Mod. 043) Cover Sealing disc Cap Strainer Plate Rivets Stainless steel (DIN-1.4021) (AISI-420) Stainless steel (DIN-1.4027) (ASTM A743CA40F) Stainless steel (DIN-1.4021) (AISI-420) Stainless steel (DIN-1.4301) (AISI-304) Aluminium Carbon steel (DIN-1.1141 Ck-15) R 1/2 to 1 (GAS, NPT or SW) Max. permissible pressure PMA. 63 bar Max. working pressure PMS. 42 bar Operating conditions Min. working pressure PmS. 0,25 bar Max. permissible temp. TMA. 400 C Permissible back pressure Until 80% inlet pressure Main catalogue - page 431

THERMODYNAMIC STEAM TRAP Model 041 043 R1 1/2 3/4 1 1/2 3/4 1 Whitworth gas tight cylindrical female thread ISO 228/1 1978 (DIN-259) Connections NPT thread ANSI-B2.1 Code 2108- Socket welding ends SW ANSI-B16.11 H 40,0 43,5 51,5 40,5 43,5 51,5 H1 55,0 58,5 70,5 55,5 58,5 70,5 h 16,0 19,0 22,5 64,0 67,5 70,0 h1 - - - 75,0 78,5 81,0 L 70,0 80,0 90,0 78,0 90,0 95,0 Weight (kg) 0,67 0,82 1,33 0,93 1,12 1,59 (1) Previous consult with our technical department. GAS 041.9022 041.9342 041.9102 043.9022 043.9342 043.9102 NPT 041.90221 041.93421 041.91021 043.90221 043.93421 043.91021 SW (1) 041.90222 041.93422 041.91022 043.90222 043.93422 043.91022 Model 041 Model 043 Prùtokový diagram kg/h 2000 Flow diagram 1000 800 600 500 400 300 1" 3/4" 1" 3/4" Model 041 Model 043 200 1/2" 1/2" 100 80 60 10,25 10,3 10,4 10,6 10,8 11,0 12 13 Flow Prùtok 14 16 18 10 20 30 42 Pressure Tlaková differential diference p p bar Main catalogue - page 432

A B C Condensate and air. Low pressure steam. High pressure steam. THERMODYNAMIC STEAM TRAP Operation: The operation of a thermodynamic steam trap is based on the Bernouilli principle: In a fluid in motion, the sum of the static and dynamic pressures remains constant at all points, such that an increase in one results in a decrease in the other. C C A A A B B The input pressure acts on the sealing disc which allows the immediate discharge of the condensate and air at the temperature of the steam. RECOMMENDED The condensate should reach the steam trap by gravity. Subsequently the steam enters the steam trap. The high speed produced by the expansion of the steam creates a zone of low pressure in the inverse side of the sealing disc. The flow is deviated to the reverse of the sealing disc and creates a zone of high pressure by recompression. The sealing disc begins to descend. When the high pressure acts on the whole surface of the sealing disc it exerts a force greater than the input pressure. The steam trap closes. The subsequent presence of condensate on the input causes the cycle to be repeated. Installation: Verify that the fluid circulates in the direction indicated by the arrow on the characteristics plate. Avoid excessive losses of load on the input, and counterpressures on the output by generously sizing the piping. The conductors should have at least the same internal diameter as the steam trap. In model 041, it is essential to locate an additional strainer before the steam trap. If a sight glass is installed after the steam trap leave about 50 cm between them. Each consumption point should have its own steam trap. A common steam trap will give rise to problems. The discharge of the steam trap to a consensate tank requires: 1. A tank with a larger diameter than the steam trap or the sum of the nominal cross sections of the steam trap connected to it. 2. The steam trap that operate at different pressures must discharge to different tanks. 3. The input of condensate to the tank must be done through its upper side. NOT RECOMMENDED Avoid welds Increased wear of the sealing disc is produced. Avoid condensate begin left in the lower part of the pipe. Increased wear of the sealing disc is produced along with the return of the dirt accumulated in the strainer. They would affect the hardness and finish of the closure zone. Main catalogue - page 433

THERMODYNAMIC STEAM TRAP Start-up: 1- On start up avoid air reaching the steam trap at high speed as it could block it. 2- The steam trap will remain open if the compression exceeds 80% of the input pressure. Assembly and disassembly: 1- Unscrew cover (2). 2- Take out the sealing disc (3). 3- Unscrew the cap (4). 4- Extract the strainer (5). 5- Locate the sealing disc (3), with the slots facing the seating in the body (1). 6- Put on the cover (2) after greasing the screw threads A and B with molybdenum bisulphate or other lubricant which is resistant to high temperatures. Tighten up to the recommended torque. 7- Clean the strainer thoroughly (5) and insert into the body (1). 8- Screw on the cap (4) greasing the screw threads as in point 6. Torques for room temperature 20 O C No. piece Piece R Nm 2 Cover 1/2 and 3/4 100 2 Cover 1 150 4 Cap 1/2 to 1 100 Maintenance: Before carrying out any maintenance work: Depressurize the steam trap and the input pipe. The strainer (5) should be cleaned regularly. The sealing disc (3) and the body seat (1) can be rectified and lapped as long as the quantity of material removed, with respect to the original thickness, does not exceed 0.25 mm. The sealing disc (3) is rectified and lapped on both sides. The slotted side must be facing the body in order that, through the turbulence generated, a delay in the closure of the steam trap is achieved meaning that the discharge of the condensate is at a temperature close to that of the steam. Main catalogue - page 434

BIMETALLIC STEAM TRAP Model 143 threaded Model 144 flanged BP MP AP BP MP AP For the extraction of steam condensates. Applicable in: steam piping, heat exchangers,... the chemical and petrochemical industries,... etc. Specifications: Materials carefully selected for resistance to wear, extreme temperatures and corrosion. Simplicity of construction. A single moveable piece together with a bimetallic strip, highly resistant to corrosion to ensure minimum maintenance. Easy installation, can be mounted in any position, although we recommend horizontal mounting. Compact and robust. Reduced weight and size which facilitates storage. Internal design of the body is conceived to provide the capacities required in each case without over sizing. Great discharge capacity. The purger also acts as a deaerator and check valve. Precision opening and closing, avoiding loss of steam. Silent. Inseparable bimetallic strip, made from a single piece, with sides of different expansion mean a high degree of sensitivity of operation. Are unaffected by vibrations, water hammer, reheated steam, corrosive condensate, frosts, etc. Large surface area filter to protect closure areas. Sealing surfaces treated and balanced, making them extremely tightness, even exceeding DIN-3230 requeriments. Page 3. All steam traps undergo throrough testing. All components are numbered, registered and checked. If requested in advance, material, casting, test and efficiency certificates will be enclosed with the steam trap. IMPORTANT: Depending demand: Other connections: Thread NPT ANSI-B2.1. BW or SW ANSI-B 16.11. ASA ANSI-150, 300 or 600 Lbs. flanges. Model BP and MP with external on-line adjustment mechanism. No. Piece Material Carbon steel 1 2 3 4 5 6 7 8 9 10 11 12 13 Body Cover Seating Plug Bimetall Joint Joint Filter Screw Nut Nut Washer Stud Carbon steel (DIN-1.0460 C22.8) (1) Carbon steel (DIN-1.0460 C22.8) (1) Stainless steel (DIN-1.4112) (AISI-440 B) RGR Graphite Copper Stainless steel (DIN-1.4301) (AISI-304) Carbon steel (DIN-1.1191 Ck-45) Carbon steel (DIN-1.1141 Ck-15) Carbon steel (DIN-1.1191 Ck-45) Type BP MP AP Low pressure Medium press. High pressure R 1/2 and 3/4 1/2 and 3/4 1/2 to 1 DN 15 to 25 15 to 25 15 and 25 PN 40 40 100 Max. pressure (bar) 17 23 80 Max. temperature ( O C) 400 400 450 (1) Type AP in Carbon steel (DIN-1.5415 15Mo3). BP MP AP Main catalogue - page 435

BIMETALLIC STEAM TRAP BP MP AP Type Low pressure BP Medium pressure MP High pressure AP R 1/2 3/4 - - - 1/2 3/4 - - - 1/2 3/4 1 - - Connection Whitworth gas-tight cylindrical female thread ISO 228/1 1978 (DIN-259) DN - - 15 20 25 - - 15 20 25 - - - 15 25 Connection Flange PN-40 DIN-2544/2545 Flange PN-100 DIN-2547/2548 H 56 56 56 56 56 115 115 115 115 115 120 120 120 120 120 H1 91 91 91 91 91 165 165 165 165 165 210 210 210 210 210 h 24,0 24,0 - - - 26,0 26,0 - - - 25,0 25,0 25,0 - - L1 - - 150 150 160 - - 150 150 160 - - - 230 230 L2 90 90 - - - 110 110 - - - 160 160 160 - - D - - 95 105 115 - - 95 105 115 - - - 105 140 K - - 65 75 85 - - 65 75 85 - - - 75 100 I - - 14 14 14 - - 14 14 14 - - - 14 18 b - - 16 18 18 - - 16 18 18 - - - 20 24 No. DRILLS - - 4 4 4 - - 4 4 4 - - - 4 4 Weight (kg) 1,60 1,50 3,00 3,50 4,00 2,60 2,50 4,00 4,50 5,00 6,00 6,00 6,00 9,00 11,00 Code 2108- Flow diagram: Flow (standard adjustment) 3000 2000 1000 143.8024 kg/h 500 300 200 143.8344 144.8024 Cold water MP 144.8344 Cold water BP 144.8104 143.80241 143.83441 100 0 2 4 6 8 10 12 14 16 18 20 22 24 Pressure differential p t=10 K BP t=10 K MP 144.80241 Flow (standard adjustment) 8000 5000 3000 2000 1000 kg/h 700 500 300 144.83441 Operation: The operating principle of the bimetallic steam trap is based on the combination in a column of double sided bimetallic discs made up of one single bimetallic strip, where each face has a different coefficient of expansion. The bimetallic strips are piled up in pairs, with the sides having the same coefficient of expansion (side without the marking) placed against each other. In the presence of cold water the bimetallic strips remain flat. As the temperature increases the discs change shape, becoming convex, and displacing the plug against the seating. The maximum convexity, which coincides with a fully tight shut off is obtained just at the point when the condensate turns to steam. It is important to remember that the distance between the plug and the seating when cold is that which determines the flow when in service. 144.81041 143.0024 143.0344 Cold water AP t=10 K AP 143.0104 144.0024 200 20 30 40 50 60 80 Pressure differential p 144.0104 Main catalogue - page 436