THE CONDENSATE STORY. Patrick Rogers Nalco Company Spokane, Washington

Similar documents
Strategies in Optimizing Condensate Return

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

BOILER SYSTEM CHEMICAL TREATMENT 101

3.1 Deaerator Systems

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

Volume 10 Summer Understanding Terminology Key to Treatment Program Success

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Water Treatment Improves Your Bottom Line DAVE PICOU WATER CARE SERVICES DIVISION JOHN SCHULTZ TEXTILE CARE DIVISON

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016

Boiler Basics. Design and operation

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

.03 ATMOSPHERIC DEAERATOR

WARE Boiler book on-line

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

Steam and air don't mix. Chemical dosing of feedwater

Kube Engineering. Industry Guide. Power Industry

CHAPTER 18 EVAPORATION AND FREEZING

The HRSG User s Group is going back to Florida!

Water Quality in Hydronic Systems April 16, 2015 with Guest Speaker Jim Poehling, P.E., LEED AP Q&A Documentation

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

Heating for Soft Fruit

Case Study and 700 HP Steam Boilers - Scale

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

10 HUGE Mistakes Facilities Make in Boiler Operation and How to Avoid Them

Silhouette. Feedwater Heater. Boiler Feedwater

Deaerators for Industrial Applications

Condensate Recovery and Return System SDR A

Information on selection of an economizer, and resulting payback due to changes in inlet water temperature.

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

IN THE PULP AND PAPER INDUSTRY

How to Trap: Process Air Heaters

How to Trap: Trap Selection and Safety Factors

Steam Trap Selection

How to Trap: Steam Tracer Lines

Water Purification 85

Feedwater Treatment Manual

Water Purification. Quality distilled... the most reliable method of purifying water 81

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

VAC-U-DRY VACUUM DEHYDRATOR

Unit D: ph of Soil. Lesson : Identifying the ph Changes in Soil

Condensate Monitoring OM0232

Pretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc.

Adca Training. Part 2

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili

CHAPTER 3 BASIC STEAM CYCLE

Other Things I Should Know?

How to Trap: Troubleshooting

OPERATING AND MAINTENANCE MANUAL

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

RESOURCES AT THE TASMAN PULP LTD'S MILL, KAWERAU, NEW

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

.005 ATMOSPHERIC DEAERATOR

The plating industry

Technical Illustration of Condensate Formation

Integrated Solutions for the. Primary Metals. Industry. Engineered Products for the Process Industries

Introduction to Heat Exchangers

A M E M B E R O F T H E K E N D A L L G R O U P

Application Data Sheet

Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel

DEAERATORS .005 ATMOSPHERIC DEAERATOR

Series 300 VTB. Installation Instructions

Prepared by Technical Team

UV-Ozone Technology and Applications

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

How to Trap: Rotating Dryers Requiring Syphon Drainage

How to Trap: Conversion Factors

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

The Ultimate in Direct Contact Water Heating. by Thermal Engineering of Arizona, Inc. An Inc. 500 Company

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

Annual Tune-Up Procedure

Element D Services Heating, Ventilating, and Air Conditioning

OPTIMIZING THE BALANCE-OF-PLANT FOR A CYCLING COMBINED CYCLE OTSG FACILITY Vito Raponi, EIT, CAPM*, Larry Guy, P.Eng.**

Plain Talk About Soil Chemistry. Plant nutrients must be dissolved in water. Dissolve-ability impacts availability.

9. Cooling Water System

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

CHX Heat Recovery THE Solution. Steam Plant Systems, Inc.

Chapter 11. Design of Other BOP

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

Trials of Vexo inhibitor in domestic central. heating systems

CEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.

Energy recovery from exhaust gases using Heat Pipe technology

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner

THERMAX Efficiency Monitor

Thermal Fluid Heaters

100 years of boiler technology leadership.

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Transcription:

THE CONDENSATE STORY Patrick Rogers Nalco Company Spokane, Washington Overview The value of condensate Condensate corrosion System survey Condensate treatment mechanical chemical Monitoring and control Condensate Receiver The Value of Condensate Heat: Reduced fuel usage - typically $6-13 per 1000 gal Water: Decreased makeup water demand Decreased pretreatment costs Reduced water discharge Boiler Reliability Improved feedwater quality Western Dry Kiln Association 9 May, 2005

Calculate the Value of Condensate Potential Savings = H x C FV x B x FC Where: Hf difference in hf between condensate stream and make-up (Btu/hr) condensate stream flow (lbs/hr) FV = heat value of fuel (Btu/fuel unit) boiler efficiency (%) FC cost of fuel ($/fuel unit) Use of Steam System Assessment Tool Western Dry Kiln Association 10 May, 2005

Unwit Steam System Assessment Tool Ko/a4/tr Mode/ Results Summary SSAT Default I Header Model.E.ARJOOP o mv!...3kuk On3lio "n2' Fmsrw,.. SC EProw$ C.e.lea ;VIM. WM:, 133 <..r Sis Mr 1 4'h =1,0 : S t.,.. 9?,! 5.s..1101E4ft Or./!T/Titf 4:(11:11, 211 1: -.2 1,..).1 cat V;1 E MCA 0. 2. :313Ar ntrif - P1 qtfa, A,, (Ve fmn.rxmor n,15-1v,4 +Val eakslarm n3. al Inler /Am wy xfro.../...5...,,,,,44pa r21:41:11 Elt Tattiti4RM*03M0 sarce,rt..u1:1 GUMMI) Arialis.11 VA, SVA.1.W ;OW. kw PIPAIPPIOLV ( 9LVO S(.01xlv has0 101 Si 1 htelkre, rx.ift..0. :.:PO L kirolitt t**04** aft r!i4' Results of Condensate Corrosion Frequent kiln coil replacement Steam/condensate line replacement Excess iron entering boiler efficiency loss deposits result in potential tube ruptures boiler cleaning due to iron deposits Unscheduled outages Primary Causes of Condensate Corrosion Condensate treatment is the battle against three dissolved gases: carbon dioxide (CO2) oxygen (02) ammonia (NH,) Western Dry Kiln Association 11 May, 2005

Carbon Dioxide Comes from Alkalinity in Make-Up Water Breakdown of feedwater alkalinity 2 HCO3 - al - 2 + H20+ CO2 Bicarbonate Carbonate Water C arbon Di oxide -2 H20 20H- + CO2 Carbonate Water Hydroxide Carbon Dioxide Air in leakage Pumps, receivers, etc. Carbon Dioxide Dissolves in the condensate forming carbonic acid coao + H2cto --> No Reaction C 2 2CA1) H2C 30) (catholic acid) Then, H2CO3m <--> + HCO3- ph Value of CO2 in Pure Water at Various Concentrations I II f.: =t..; '-(9117 ' PM, to......,...' W%,,) Illifila -., 4 ',yew. 1,174 t Western Dry Kiln Association 12 May, 2005

Carbonic Acid Corrosion Results in a thinning and grooving of the metal surface. Usually on the pipe where the condensate lays. Oxygen Sources Air in-leakage: pumps, traps, vacuum systems, vented receivers, week-end shutdowns Inefficient deaeration operation Raw water intrusion: pump seals, heat exchanger leaks Oxygen Corrosion 0 2 attack results in pitting type corrosion. Rapid localized metal loss. Combined corrosion rate of carbon dioxide and oxygen is 10-40% faster than the sum of either alone. Western Dry Kiln Association 13 May, 2005

System Survey A complete system survey is the key to any effective corrosion prevention strategy. The survey defines system needs and limitations allow for proper MOC solution Mechanical Operational Chemical Key Considerations Make-up water quality CO 2 generation Percent condensate return amine recycled, determines makeup quantity Potential for system contamination System configuration and complexity (steam uses) amine selection Mechanical Reduction of Corrosion Potential Prevent stagnation/coil water logging Reduce air in leakage Assure proper deaeration Reduce feedwater alkalinity Mechanical: Steam Trap Maintenance Annual maintenance checks Four-six years, 50 percent of traps will likely be failing open or closed Efficiency/corrosion Problems do not surface until too late w/o a formal trap program Mechanical: Condensate Delivery Potential Issues Above ground condensate recovery tanks rely on steam pressure through coils to elevate to the height of tank Condensate pumps not utilized rely solely on steam pressure to push condensate to boiler house Both can result in stagnant condensate elevated corrosion rates decreased coil efficiency Operational/Mechanical Common Air In-Leakage Sites Vacuum systems Vented receivers Condensate pumps, traps, and valves Intermittently operating systems Operational: Feedwater Alkalinity Reduction Lime softening Reverse osmosis Western Dry Kiln Association 14 May, 2005

Dealkalization Demineralization Increased condensate return Chemical: Condensate Treatment Neutralizing amines Filming amines Condensate Treatment Requirements Effective corrosion protection Distribution throughout system Which chemistry do we primarily use to combat carbonic acid? Why Amines are so Popular Direct neutralization of CO2 Direct elevation of ph Easy to feed/control Compatible with other system treatments Treatment recycles Blends available: able to distribute through entire systems Neutralizing Amines Limitations/Considerations Not effective against oxygen Perhaps not best choice in high alkalinity waters Not all locations will have same ph: a blend of amines is typically required good distribution volatility ratio Filming Amines Long chain amines that absorb onto the metal surface Function at the lower ph range of 6.5 to 9.0 Metallic wall Protective filming amine layer Western Dry Kiln Association 15 May, 2005

Protect against acids, 02, and ammonia Dosage dependent on surface area and not contaminant concentration Cost effective in high CO 2 systems Filming Amines Limitations/Considerations Film formation takes time ph control still necessary Should be fed after turbines and condensate polishers Will clean up old deposits Overfeed may cause sticky deposits and "gunk" ball formation Nalco ACT Quality Control: Condensate Monitoring ph Conductivity Corrosion rates Corrosion byproducts Secondary Testing and Troubleshooting Dissolved oxygen Hardness Silica Ammonia Alkalinity Product residual Corrosion and Corrosion Byproducts Grab samples filtration millipore testing wet chemistry colorimeter testing * total iron insoluble iron (particulate) * soluble iron (indicative of recently corrosion activity Corrosion coupons Corrosion sensor Nalco Corrosion Sensor Monitors corrosivity of condensate real time indication Provides direct MPY readings up to 300'F Collects and displays all data Western Dry Kiln Association 16 May, 2005

Sampling Requirements Cooled to less than 90 F* (ph) Sample flow throttled at outlet only* Stainless steel sample lines Continuous flow Adequate velocity Sampling Sample tap locations 45 degrees off bottom of horizontal pipe Representative of system Prior to condensate receivers* Sampling Horizontal Lines Sarnp e tap 1)2 in. diem. SS-- gate valve 1/4 inss sample line Key Take-Aways Condensate is a precious commodity Never underscore its value Take every opportunity to return as much condensate as possible, look for lost condensate, it is out there. Every system is unique Complete proper survey Always mechanical before chemical Alkalinity removal prior to boiler Check each trap once per year Proper flow for condensate return Proper condensate monitoring in place Western Dry Kiln Association 17 May, 2005